| 1 | Material and labour for painting of steel tubular pole with 2 coats of synthetic enamel paint upto 1.5m above ground level (in white and black strips of 30cm each) and 2 coats of aluminum paint above 1.5 mtr height including cross arms, bracing ,clamps GI pipe fittings etc as per site after preparation of surface including writing pole Nos, feeder Type with black paint complete all as specified and directed. |
| 2 | Supply and fixing street light junction box insulated and made out of environment friendly, recyclable, UV resistant, halogen & silicon free,polycarbonate with glass fiber reinforced of size in mm should be not less then 205 X 255 X 112. The box shall be rated for Degree of Ingress Protection IP 66/67 including busbar,MCB and all fixing material as required all as specified and directed.Make: cat. Part no KF2525 of Hensel or equivalent in Siemens/GE Power/Rittal. |
| 3 | Supply and laying fixing 2.5 sqmm (nominal area) Aluminium conductor, twin core, PVC insulated unsheathed cable, drawn in steel/PCC pole for connection to street light fitting and making incl PVC Pipe of suitable size connections, complete all as specified and directed. |
| 4 | S&F the following unsv parts of automatic mains failure (AMF) panel 12 v DC and 440 V AC supply operated system, all as specified and directed by engr-in-charge |
| 5 | (a) Alternator voltage monitor relay 3 phase 415 V |
| 6 | (b) Solid state electroniccard |
| 7 | (c) Battery charging rectifier 4 plate, 12 volts DC Cart No. 4.H878.07.000 |
| 8 | (d) Self Start electronic cantrol panel for DG Set any capacity Make : Kirloskar |
| 9 | (e) S & F contactors 4 pole MCX type frame for AMF panel of suitable for existing size / Amps complete all as spesified and directed.Make : L&T |
| 10 | Supply and fixing of battery 12 Volts, 150 AH suitable for DG Set complete all as specified and directed. |
| 11 | Repair and Replacement of High Mast Light with Components including Head Frame & Pulley Assembly, Winch Bracket, Lantern Carriage Ring for Luminaries and C.G Box Mtg. Arms, Resting Bracket Guide Ring, compensating Disc, Lightening Arrestor, LED AOL, Wire Rope, Safety Wire Rope, D Suckle Clamps, nuts and Bolts, internal Cable, foundation Accessories., winch assembly with two drums with SWL 750KG and internal power tool of 0.25-2 HP with control panel. as specified and directed by engineer-in-charge |
| 12 | Repair of LED Flood Lights alongwith proper LED Driver and other Necessary Parts complete all as specified and directed |
| 13 | Supply and fixing driver for LED flood Light 100 Watt capacity all as specified and directed by engr-in-charge. |
| 14 | Supply and fixing driver for LED flood Light 150/250 Watt capacity all as specified and directed by engr-in-charge. |
| 15 | Supply and fixing driver for LED street Light 60 Watt capacity all as specified and directed by engr-in-charge. |
| 16 | Supply and fixing driver for LED street Light 70 Watt capacity all as specified and directed by engr-in-charge. |
| 17 | CAPACITY 30 KVA TO 45 KVA(a) Servicing of DG Set 30 KVA to 45 KVA of any make including changing of engine oil sump gasket with nuts bolts and check the all nuts bolts complete of engine and alternator alongwith replacement of defective parts, complete all as specified and directed. (Note: All parts make kirloskar)(i) 30 KVA - 04Nos (SMC & 41, Khasa Domestic area,DSC Sewage PH., PH No.2 ) (ii) 35 KVA - 03 Nos (PH No 1, Domestic area) PH No 3 (Tech Area) & PH No 4 (Muradpur area)(iii) 45 KVA - 02 Nos (Immols & Airmen Mess) |
| 18 | (b) S&F in replacement lube oil filter element complete all as specified and directed engineer –in-charge |
| 19 | (c) S&F in replacement fuel filter element complete all as specified and directed engineer –in-charge |
| 20 | (d) S&F In replacement exhaust pipe, canopy glass alongwith Complete servicing & make ready of Entire Generator Pumping Set wherver required complete all as specified and directed engineer-In-Charge |
| 21 | (e) General servicing of DG set by opening of tappet cover/top cover tappet clearance setting with injector timing adjustment reffixing of tappet/top cover including replacement of tappet cover packing set, shellac/bostic tube all as directed. |
| 22 | (f) S&F in replacement element air cleaner complete all as specified and directed engineer –in-charge |
| 23 | (g) Tightining of all electrical connection AVR connection , alternator connection and Panel connections |
| 24 | (h) Tightining of all the hoses , replacement of leakage Fuel connection any size and length. |
| 25 | (j) Testing of Engine on load for 30 Minutes. |
| 26 | Note:- The Service of Engine must be done by authorized service person of the Kirloskar Oil Engines Ltd. All Service Documents must be uploaded on the authorized website of Kirloskar Oil Engines Ltd. and must be readily available for download. |
| 27 | CAPACITY 75 TO 125 KVA(a) Servicing of DG Set 75 KVA to 125 KVA of any make including changing of engine oil sump gasket with nuts bolts and check the all nuts bolts complete of engine and alternator alongwith replacement of defective parts, complete all as specified and directed.(Note: All parts make kirloskar)(i) 75 KVA - 01 Nos (AF Net)(ii) 82.5 KVA - 01 Nos (Muradpur for security light) (iii) 125 KVA - 02 Nos (PH No 2 & Exchange) |
| 28 | (b) S&F in replacement lube oil filter element complete all as specified and directed engineer –in-charge |
| 29 | (c) S&F in replacement fuel filter element complete all as specified and directed engineer –in-charge |
| 30 | (d) S&F In replacement exhaust pipe, canopy glass alongwith Complete servicing & make ready of Entire Generator Pumping Set wherver required complete all as specified and directed engineer-In-Charge |
| 31 | (e) General servicing of DG set by opening of tappet cover/top cover tappet clearance setting with injector timing adjustment reffixing of tappet/top cover including replacement of tappet cover packing set, shellac/bostic tube all as directed. |
| 32 | (f) S&F in replacement element air cleaner complete all as specified and directed engineer –in-charge |
| 33 | (g) Tightining of all electrical connection AVR connection , alternator connection and Panel connections |
| 34 | (h) Tightining of all the hoses , replacement of leakage Fuel connection any size and length. |
| 35 | (j) Testing of Engine on load for 30 Minutes. |
| 36 | Note:- The Service of Engine must be done by authorized service person of the Kirloskar Oil Engines Ltd. All Service Documents must be uploaded on the authorized website of Kirloskar Oil Engines Ltd. and must be readily available for download. |
| 37 | CAPACITY 200 TO 250 KVA(a) Servicing of DG Set 200 KVA to 250 KVA of any make including changing of engine oil sump gasket with nuts bolts and check the all nuts bolts complete of engine and alternator alongwith replacement of defective parts, complete all as specified and directed. (Note: All parts make kirloskar)(i) 200 KVA - 01 Nos (Muradpur area)(ii) 250 KVA - 01 Nos (Radar power house Tech area) (iii) 250 KVA - 01 Nos (Rohni Radar Tech area) |
| 38 | (b) S&F in replacement lube oil filter element complete all as specified and directed engineer –in-charge |
| 39 | (c) S&F in replacement fuel filter element complete all as specified and directed engineer –in-charge |
| 40 | (d) S&F In replacement exhaust pipe, canopy glass alongwith Complete servicing & make ready of Entire Generator Pumping Set wherver required complete all as specified and directed engineer-In-Charge |
| 41 | (e) General servicing of DG set by opening of tappet cover/top cover tappet clearance setting with injector timing adjustment reffixing of tappet/top cover including replacement of tappet cover packing set, shellac/bostic tube all as directed. |
| 42 | (f) S&F in replacement element air cleaner complete all as specified and directed engineer –in-charge |
| 43 | (g) Tightining of all electrical connection AVR connection , alternator connection and Panel connections |
| 44 | (h) Tightining of all the hoses , replacement of leakage Fuel connection any size and length. |
| 45 | (j) Testing of Engine on load for 30 Minutes. |
| 46 | Note:- The Service of Engine must be done by authorized service person of the Kirloskar Oil Engines Ltd. All Service Documents must be uploaded on the authorized website of Kirloskar Oil Engines Ltd. and must be readily available for download. |
| 47 | CAPACITY 30 KVA TO 45 KVA |
| 48 | (a)Supply & Fixing in replacement of AUtomatic Voltage Regulator (AVR) alongwith all Necessary Connections to Genset complete all as specified and directed |
| 49 | (b)Supply & Fixing in replacement of Feed Pump Assembly complete all as specified and directed |
| 50 | CAPACITY 75 KVA TO 125 KVA |
| 51 | (a)Supply & Fixing in replacement of AUtomatic Voltage Regulator (AVR) alongwith all Necessary Connections to Genset complete all as specified and directed |
| 52 | (b)Supply & Fixing in replacement of Feed Pump Assembly complete all as specified and directed |
| 53 | CAPACITY 200 KVA TO 250 KVA |
| 54 | (a)Supply & Fixing in replacement of AUtomatic Voltage Regulator (AVR) alongwith all Necessary Connections to Genset complete all as specified and directed |
| 55 | (b)Supply & Fixing in replacement of Feed Pump Assembly complete all as specified and directed |
| 56 | M&L for repairing cleaning/ servicing of radiator assembly of DG set including decaling of tubes with solution and chemicals and compressed air blast including soldering/gas welding of leaking tubes including cutting welding of rusted ms tubes with new tubes transportation to workshop, and back and re fixing after testing complete and making it leak proof complete all as specified and directed. |
| 57 | S&F fan belt set of DG set of existing size complete all as specified and directed engineer –in-charge |
| 58 | S&F in replacement head gasket of DG set complete. |
| 59 | M&L for rewinding of DG set self start assembly of any capacity with super enamelled copper winding wire of existing gauge including replacement of unserviceable spare parts of existing make and re-assembling connecting and testing on load all as directed by the Engr-in-charge. |
| 60 | Supply and filling of multigrade Diesel engine oil 20w/40 suitable for DG Set complete all as specified and directed. |
| 61 | Supply only coolant suitable for DG Set against respective items, complete all as specified and directed. |
| 62 | Demolition of cement concrete ( unreinforced) of any description and in any position not otherwise specially provided for including removal of debries out of defence land complete all as specified and directed |
| 63 | Material and labour for 100 mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in sub base of floors, complete all as specified and directed. |
| 64 | Material and labour for 50 mm thick plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in floors, finished the surface even and fair, complete all as specified and directed. |
| 65 | Supply and fixing in replacement of VMR (Voltage moniring Relay) suitable for existing DG Set complete all as specified and directed. |
| 66 | Supply and topping up of distilled water in lead acid battery of DG set of any capacity complete as specified and directed by Engr-in-charge |
| 67 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete |
| 68 | M& L in replacement of UNSV battery charger auto type of capacity 12 V, 6 Amps for charging lead acid batteries as specified and directed by Engr-in-charge |
| 69 | Supply and fix timer switches 415 V three Phase of 6 KW digital 24 Hrs type with contactor fitted inside steel enclosure complete with all connecting accessories all as specified and directed by Engineer in charge.Make: Havells or equivalent. |
| 70 | M&L for repairing cleaning/ servicing of fuel tank of DG set of any capacity including soldering/gas welding of leaking tanks including cutting welding of rusted ms tubes with new tubes and other parts transportation to workshop, and back and re fixing after testing complete and making it leak proof complete all as specified and directed. |
| 71 | Taking out alternator of 30 KVA to 200 KVA DG sets of any make, rewinding with super enamelled copper wire of suitable gauge, varnishing, changing insulating material, assembling, testing and connecting to DG set complete all as specified and directed by Engr-in-Charge Note:- Rates quoted by contractor deemed to be included the rates for tranportation of alternator from site to workshop and returning the alternator to site from workshop alogwith fixing the same on the generator in working Conditions. The repair of alternator should be as per the manufacturing Norms. |
| 72 | Material & Labour for painting to DG Set of 30 KVA to 250 KVA by gun spray for existing colour all as specified and directed |
| 73 | Supply and fixing in repair Three phase Voltmeter Digital type class 0.5 incl of suitable for existing make complete all as spceified and directed by Engr-in-charge. |
| 74 | Supply and fixing in repair Three phase Ammeter Digital type class 0.5 of suitable for existing complete all as spceified and directed by Engr-in-charge. |
| 75 | M&L for Cleaning Solar Power Plant, Diesel Generator and their surroundings after ensuring the equipment/machinery/plant remain fully Functional complete as specified and directed. |
| 76 | Note: The Total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit. Please Enable Macros to View BoQ information |