| 1 | M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 including Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stonework and precast concrete articles complete all as specified and directed. |
| 2 | M&L for rendering 10mm thick on stone/brick masonry surfaces or other than fair faces in cement mortar 1:6 finished even and smooth (without using extra cement) including Taking down of cement plaster of any description including racking out of joints hacking for keys and scrubbing down with water etc complete all as specified and directed. |
| 3 | M&L for rendering 15mm thick in cement mortar 1:4 on brick walls finishing even and fair including necessary scaffolding work etc complete with water proofing compound complete all as specified and directed. |
| 4 | M&L for rendering 15mm thick on stone/brick masonry surfaces or other than fair faces in cement mortar 1:4 finished even and smooth (without using extra cement) including Taking down of cement plaster of any description including racking out of joints hacking for keys and scrubbing down with water etc complete all as specified and directed. |
| 5 | M&L for preparation of new plastered surfaces of wall and applying two coat of cement base paint on wall surface over a coat of alkali resistance primer complete all as specified and directed. |
| 6 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of alkali resistant primer including chalk whiting complete all as specified and directed. |
| 7 | M&L for providing, cement concrete 1:2:4 type B-1 as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided in, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 8 | M&L for precast reinforced cement concrete type B1 1:2:4 cover slabs (for man holes/Drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 including demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 9 | M&L extra for forming fair finished drain or channel up to 30 cm inner girth in cement concrete, using extra cement including forms/moulds/mitred stopped ends etc complete all as specified and as directed by Engineer-in-charge. |
| 10 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed, |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 12 | S&F for Mild steel works in roof trusses (framed) trussed, Purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, Angle, Channel or flat section) including distance pieces, cleats, welding and bracing etc, Fe-410W (Gde-E-250) quality-B complete all as specified and directed. |
| 13 | S&F mild steel frame work for such as grills, grating etc, with ends of bars shouldered &/or riveted or forged into spikes, framed guard bars, barred iron door ladder, frame balusters, walk ways, railing, frame work or water tanks & similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 14 | S&F mild steel work for such as hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 |
| 15 | S&F Pre-painted galvalume aluminium Zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPa as in roof covering/cladding to wall, fixed with self tapping screw including necessary scaffolding, upto four storey building including dismantling of old unserviceable steel sheet complete all as specified and directed Note : Cost of scaffolding work for fixing of roof sheet to be included in the unit rate quoted by the tenderer. |
| 16 | S & F of Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including necessary scaffolding, upto four storey building including dismantling old unserviceable steel sheet complete all as specified and directed Note : Cost of scaffolding work for fixing of roof sheet to be included in the unit rate quoted by tenderer. |
| 17 | S&F in repair 20mm thick 2nd class softwood boarding, planed one side, with butt joints and fixed with nails in facia eaves boarding in ceiling complete all as specified and directed. |
| 18 | S&F in repair 2nd class softwood weather boarding clean sawn, plain 20mm thick or feather edged 15mm to 20mm thick and fixed with 30mm laps complete all as specified and directed. |
| 19 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 20 | Treatement for sunken portion is as follows :-Stage-1:- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs of STP Ltd/SIKA in the proportion / quantity all as per manufacture instructions. Stage-2:- Providing 10mm thick plaster in cement mortar 1:3 mixed with integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd/SIKA in the proportion/ quantity all as per Manufacture instructions. |
| 21 | Stage 3:- Apply Dr Fixit Prime seal primer or Equivalent of STP Ltd/SIKA (and allow to dry for 8 hours) all as pr Manufacturer's instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions. Stage 5:- Rendering 10mm thick in cement mortar 1:3 mixed with integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd/SIKA all as per Manufacturer's instructions. |
| 22 | Stage 6:- All CI joints shall filled with mixture of cement fine sand plaster seal of STP Ltd/SIKA or Dr Fixit Pidicrete URP all as per Manufacturer's instructions. Stage 7:- Making holes in wall and fixing 600mmm long 20mm dia medium grade GI spout for draining the surplus water if any. Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion.Note:- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's /Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item (c) Rate quoted by contractor shall be deemed to be included for all the horizontal and vertical treated surfaces of sunken portions of WC & Bath. |
| 23 | M&L for cement concrete type D-2 1:4:8 using 40 mm graded aggregate as in filling and mass concrete complete all as specified and directed. |
| 24 | M&L 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in floor complete all as specified and directed. |
| 25 | M&L Non-skid Coloured Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile on 15mm thick screed bed in CM 1:4 including dismantling of floor hearth or wall tiling including cement mortar bedding complete all as specified and as directed. |
| 26 | M&L for coloured heavy duty Non skid tiles 10 mm thick parking /exterior tiles polished, area of each tiles not exceeding 0.36 sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:4 for laying floor finishes including dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed. |
| 27 | M&L for coloured glazed ceramic tiles as in skirting/ dado (350x250 or 450x350) x 7mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match colour of the tile over backing coat/screed bed 10mm thick in CM1:4 on fair faces of brick/stonewall surface for laying dado/skirting including dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed. |
| 28 | M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile on 15mm thick screed bed in CM 1:4 including dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and as directed. |
| 29 | M&L Non-skid Ceramic tiles coloured 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile on 15mm thick screed bed in CM 1:4 including dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and as directed. |
| 30 | S&F in repairs Vitreous China squatting pan (Orissa pattern) size 580 x 450 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor, fixed in repair, complete all as specified and directed. |
| 31 | Taking down chowkhat with shutter without taking off shutter from the frame exc 1.5 Sqm and not exc 4 Sqm each. |
| 32 | Taking down of shutter exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed. |
| 33 | Taking down of shutter nexc 1 sq. m each complete all as specified and directed. |
| 34 | S&F 35mm thick made of 2nd class soft wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed. |
| 35 | M&L for factory made 30mm Glazed and skeleton shutters, for windows open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beadss, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 36 | S&F in repair door closer hydraulically regulated Aluminium (extruded section) body , designation No. 3, universal type, suitable for door shutters and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 37 | S&F for Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing etc complete all as specified and directed. |
| 38 | S&F for Factory made solid PVC Moulded door shutter, 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS etc complete all as specified and as directed. |
| 39 | S&F stainless steel butt hinges, 100mm, medium weight complete all as specified and directed. |
| 40 | S&F extruded aluminium alloy with galvanised mild steel hinge pin Butt hinges 75mm long type C-21 complete all as specified and directed. |
| 41 | Supply and fix extruded aluminium alloy handles, fabricated type of size 150mm in any position complete all as specified and directed. |
| 42 | S&F extruded aluminium alloy handles 125mm size fabricated type anodized ISI marked complete all as specified and directed. |
| 43 | S&F aluminium, anodised, barrel tower bolts of extruded section of size 150mm complete all as specified and directed. |
| 44 | S&F Aluminium anodised, barrel tower bolts of extruded section and fixed 100mm long complete all as specified and directed. |
| 45 | S&F in repairs 500 ltrs rotational Moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed. |
| 46 | S&F in repairs 1000 ltrs rotational Moulded polythelyne water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed. |
| 47 | S&F in repair ball valves, high pressure, with polythene float and fly nut complete, 20mm bore complete all as specified and directed. |
| 48 | S&F in repair 20mm bore gun metal globe or gate valve with iron wheel head, screwed both ends complete all as specified and directed. |
| 49 | S&F steel tubes medium grade 'galvanised' with and including all fitting and fixed bore of 20 mm dia including taking up or down steel tubing and connections complete to walls and ceiling or laid in floors of 20 mm bore complete all as specified and directed. |
| 50 | S&F steel tubes medium grade 'galvanised' with and including all fitting and fixed bore of 15mm dia including Taking up or down steel tubing and connections including cleaning for refixing or removal to store complete to walls and ceiling or laid in floors of 15mm bore complete all as specified and directed. |
| 51 | Demolition of concrete in ground floors (un-reinforced) and paving n.exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 52 | M&L for 75 mm thick cement concrete type C-1 1:3:6 (20mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 53 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including over 15mm thick screed bed in CM 1:4 etc complete all as specified and directed. |
| 54 | M&L for 60mm thick Machine Pressed precast paver block M-35 grade laid over sand cushioning after consolidation set and levelled the paver block on proper level with inter locking and size conforming to IS 15658-2006 with grey cement and pigment (LAQUER FINISH) and including dismantling of paver blocks etc complete all as specified and directed. (Note: Sand cushion will be measured and paid separately) |
| 55 | M&L for machine cut Kota stone slab flooring 20 to 25mm thick as in floor, cooking platform, treads etc .laid over 20 mm screed bed or bedding layer in CM 1:6 set and jointed in neat cement slurry and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing by machine including demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed. |
| 56 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 57 | M&L for PVC valve less syphonic action type flushing cistern 10ltr capacity, low level white with inlet ball valve float and handle including brackets including 32mm dia PVC. flush pipe for low level cistern including all joints, complete all as specified and directed. |
| 58 | S&F in repair 15mm size PVC connection with PTMT nuts 600mm long complete all as specified and directed. |
| 59 | S&F in repairs CP pillar taps 15mm bore cast copper alloy chromium plated fancy type complete all as specified and directed. |
| 60 | S&F in repairs 15mm dia Brass CP wall/basin mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 61 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 62 | S&F in repairs CP stop valves/angle cock 15mm bore fancy type chromium plated with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed. |
| 63 | S&F in repairs two way angular stop cock chromium plated 15mm dia complete all as specified and as directed. |
| 64 | S&F in repairs stop valves PVC (PTMT) type coloured 15mm bore screwed both ends for iron pipes or for unions and fixed complete all as specified and directed. |
| 65 | S&F in repairs chromium plated long nose bib tap 15mm bore fancy type chromium plated with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 66 | S&F in repairs bib tap PVC (PTMT) type coloured 15mm bore screwed for iron pipe or for unions and fixed complete all as specified and directed. |
| 67 | S&F in repair PVC (PTMT) angle cock of any screwed for iron pipe and fixed (min wt 15mm-90gms) complete all as specified and directed. |
| 68 | S&F CI floor trap 75mm dia outlet with CP grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and directed. |
| 69 | S&F CI floor trap 100 mm dia outlet with CP grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and directed. |
| 70 | S&F 75 mm bore PVC SWR pipe single socketed (ISI Marked) any length with rubber ring joints complete fittings etc fixed to wall with MS clamps 8mm dia with two nuts wall nails etc complete all as specified and directed. |
| 71 | S&F 110 mm bore PVC SWR pipe single socketed (ISI Marked) any length with rubber ring joints complete fittings etc fixed to wall with MS clamps 8mm dia with two nuts wall nails etc complete all as specified and directed. |
| 72 | S&F 75mm bore PVC (SWR) bends any radius diminishing pieces or tapers with access doors etc, complete all as specified and directed. |
| 73 | S&F 110mm bore PVC (SWR) bends any radius diminishing pieces or tapers with access doors etc, complete all as specified and directed. |
| 74 | Cleaning of PVC water tank capacity n. exc 500 litres.at any height (on accessible/ inaccessible roofs) by removing all scale, dirt, mud, any foreign material and removing accumulated silt, other dirty substance, algae, fungus and other bacterial material from sides/bottom of tank cleaning shall be done by draining / pumping out water/sludges from bottom removing edge and other growth from wall/ floor/ roof by high pressure cleaning method with jet set and again cleaning tank with fresh water etc complete all as specified and directed. |
| 75 | All as per srl item no 72 above but PVC water tank capacity exc 501 litres but n.exc 1000 litres. |
| 76 | All as per srl item no 72 above but PVC water tank capacity exc 1001 litres but n.exc 2000 litres. |
| 77 | M&L for preparation of old wooden surfaces of any description, not other wise described over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 78 | M&L for preparation of newly un treated surfaces and applying two coat of synthetic enamel paint over a coat of pink primer on wooden surfaces of any description not other wise described over 10 cm width or grith etc complete all as specified and directed. |
| 79 | M&L for preparation of old steel surfaces of any description, not other wise described over 10cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 80 | S&F in repairs wash hand basin vitreous China white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper nut including brackets, 32mm waste fittings and waste pipe of 32mm bore, brass chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed. |
| 81 | S&F in repair brass Chromium plated towel rail 20mm dia 'D' type 600mm long between flanges, Cat No BA-01 of with and including Chromium plated brass screws etc complete all as specified and directed. |
| 82 | S&F in repair Health Faucet with 1.5mtr tube & hook Cat No BEA-40 of Prayag Polymers Pvt Ltd complete all as specified and directed. |
| 83 | S&F for 20mm dia fancy type chromium plated curtain rods with fixing fancy brackets, screws etc complete all as specified and directed. |
| 84 | S&F in repair plywood grade BWR type BB, 9mm thick fixed with nails to timber frame work in wall/ ceiling complete all as specified and directed. |
| 85 | S&F in repair plywood grade BWR type BB, 6mm thick fixed with nails to timber frame work in wall/ ceiling complete all as specified and directed. |
| 86 | S&F in repair Veneered decorative plywood, 9mm thick grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with nails to timber frame work as in ceiling/wall complete all as specified and directed. |
| 87 | S&F in repair Veneered decorative plywood, 6mm thick grade 1 (with BWR resin) with decorative face veneers on one faces; fixed with nails to timber frame work as in ceiling/wall complete all as specified and directed. |
| 88 | M&L for 10 to 12 mm thick 2nd class softwood wall panelling of good quality wood planed one side and edges tonged and grooved or rebated other side and dovetailed joints, chamfered both sides fixed to frame work with secret nailed as in wall/ceiling panelling 15mm including cornice and beading as required and applying two coats of polishing over one coat of sealer after preparation of the surface, complete all as specified and as directed including dismantling of wall and ceiling boards or insulation boards/slabs/blankets complete all as specified and directed. Note: Framework shall be measured and paid separately. |
| 89 | M & L second class soft wood in scantling clean swan below or above ground level upto four storey building, including dismantling timber scantling 40 Sqcm and over in section in any position complete all as specified and directed. |
| 90 | M & L Plain fillets 2nd class soft wood of exc. 3 & n exc. 6 Sqcm, square rectangular or triangular in section, clean swan, secured with nails complete all as specified and directed. |
| 91 | S&F lagging to 20mm dia pipes used in water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 including chicken mesh wire netting 25 gauge, 20mm mesh complete all as specified and directed. |
| 92 | M&L for M&L for cleaning/removal of blockage and removing deposited sludge/liquid materials, foreign materials from manholes, pipe lines through vacuum pressure Jet machine complete all as specified and directed. |
| 93 | Taking out/pumping out sewage water from septic tank/soakage well from vehicle with attached water tank of 3000 ltr capacity with mechanical pump and sucking and removing and dumping of the same place at the place marked for the purpose by the authority controlling the area complete all as specified and directed. Note:- Distance for removal from original point to disposal point is marked by the AGE/GE. |
| 94 | Dewatering/pumping/bailing out contaminated with waste material sludge from septic tank along with inlet outlet chamber of any capacity/depth and disposing same out of cantonment area in a closed container including taking off manhole covers and putting back the same after cleaning/removing the liquid waste material of septic tanks and cutting holes through slab/ wall where required for inserting pipe and making good the same with cement mortar to match with existing surfaces to make hygienically fit, writing the date of cleaning of septic tank with black and white paint of size 150 x 200mm and finally spraying unslaked lime (bleaching powder), dry, around and over the septic tank complete all as specified and directed. Note:- 1. Qty of liquid sludge shall be measured for payment under this item. 2. Arrangement of land for the disposal of waste is complete responsibility of contractor. |
| 95 | M&L for cleaning of sewage lines of 100mm /150mm bore including manholes by means of cleaning rods through manholes to manholes, including dewatering (if any) taking out sludge collected in manholes, depositing the same in the pit at a minimum distance of 50 m from nearby living ACCN and covering the sludge in pit with earth and finally spraying unslaked lime, dry , around the manholes and cover the pit, out of Garrison in a closed container if living area/Cook house/Office complex not less than 50m from where work is progressed complete all as specified and directed. Note:- Cost of earth work in the pit is deemed to be included in the unit rate quoted by tenderer. |
| 96 | M&L for 20 users on site LLDPE septic tank designed to carry sewage and sullage water, with Vent shaft, connection etc., with up flow filter including media complete all as specified and directed. |
| 97 | M&L for 10 users on site LLDPE septic tank designed to carry sewage and sullage water including Vent shaft, connection etc., with up flow filter including Media complete all as specified and directed. |
| 98 | Excavation in trenches n.exc 1.5 m wide & n.exc 1.5 deep for foundation for shafts, wells, cesspits, manholes etc not exc 10 sqm on plan and getting cut in soft/loose soil complete all as specified and directed. |
| 99 | All as per item No 96 here-in-before but exceeding 1.5 mtr but n.exc 3.0 m depth. |
| 100 | Removal of excavated material to a distance not exceeding 50m and deposited where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 101 | S & F in repair Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails including securing or tying with and provision of galvanised MS wire staples or steel pins etc complete all as specified and directed. |
| 102 | S&F in repair for concertina coil fencing with punch tape concertina coil 600 mm dia having 10 round/ RM upto 4 mtr height of wall with angle iron 'Y' shape complete all as specified and directed. Note:- Angle iron shall be measured and paid separately. Please Enable Macros to View BoQ information |