| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GARRISON ENGINEER (AF) BANGALORE NAME OF WORK :REPAIR/MAINT OF WATER SUPPLY DISTRIBUTION NETWORK SYSTEM PIPE LINE WITH FITTINGS AT POCKET I AND REPAIR/MAINT OF VARIOUS CAPACITIES OF PUMP SETS, EARTHING AND CONNECTED WORKS AT CHAF BANGALORE CA NO: GE(AF)/B/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | COMMON ITEMS APPLICABLE FOR 'JOB A' & 'JOB B' |
| 3 | Supply fabrication and fixing MS joints like Flanged, bends, Tee, Tapers, collars, elbow, tail piece (any type) caps, plugs for 80 mm to 300 mm bore pipe, angle iron/MS plate including nuts,bolts,washers, welding,drilling holes for bolts in any shape or size as indicated or directed for making staging of the tank and painting with one coat of red oxide zinc chrome primer as under coat and one finishing coat of aluminium paint .complete all as specified and directed.Sl no 69 of Job B + Sl no 36 of job A |
| 4 | ITEMS APPLICABLE FOR 'JOB A' |
| 5 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. and taking out/laying of pipe lines of soft/loose soil complete all as specified and directed. |
| 6 | Returning, filling in, including spreading, leveling, watering and well ramming in layers, each layer not exceeding 25cm thick after pipes have been laid and tested complete all as specified and directed. |
| 7 | Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete complete all as specified and directed. |
| 8 | Taking up or down old unseviceable GI pipe of size 40/50 mm dia including all fittings complete all as specified and directed. |
| 9 | All as per ser item 7.00 here-in-before but of 25 mm dia |
| 10 | All as per ser item 7.00 here-in-before but of 20 mm dia |
| 11 | S&F GI pipes of size 100 mm dia, medium grade, galvanized with all fittings such as bends, tees, nipples, union and sockets, clamps etc laid in trenches, under floor/walls etc complete all as specified and directed. |
| 12 | All as per ser item 10.00 here-in-before but of 80 mm dia |
| 13 | All as per ser item 10.00 here-in-before but of 50 mm dia |
| 14 | All as per ser item 10.00 here-in-before but of 40 mm dia |
| 15 | All as per ser item 10.00 here-in-before but of 25 mm dia |
| 16 | All as per ser item 10.00 here-in-before but of 20 mm dia |
| 17 | All as per ser item 10.00 here-in-before but of 15 mm dia |
| 18 | Refixing GI/CI pipe obtained from Item No 7.00 here-in-before and connections in new or old position (walls, trenches, ceiling and floors etc) of size 50 mm dia complete including main branch connections complete all as specified and directed. |
| 19 | All as per ser item Item No 17.00 here-in-before but of 40 mm dia obtained from item No. 07 |
| 20 | All as per ser item 17.00 here-in-before but of 25 mm dia obtained from item No. 8 |
| 21 | All as per ser item 17.00 here-in-before but of 20 mm dia obtained from item No. 9 |
| 22 | S&F in replacement cast iron sluice valve suitable of size 200 mm (PN 1.6) ISI Marked with iron wheel head both end flanged, non rising type and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,complete all as specified and directed.. |
| 23 | All as per ser item 21 here-in-before but of size 150 mm dia |
| 24 | All as per ser item 21 here-in-before but of size 100 mm dia |
| 25 | All as per ser item 21 here-in-before but of size 80 mm dia |
| 26 | S&F in replacement of CI non return valve suitable for 150 mm bore pipe heavy duty both end flanged of pressure rating PN 1.6 and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,complete all as specified and directed. |
| 27 | All as per ser item 25.00 here-in-before but of size 100 mm dia. |
| 28 | All as per ser item 25.00 here-in-before but of size 80 mm dia. |
| 29 | All as per ser item 25.00 here-in-before but of size 50 mm dia. |
| 30 | S&F Foot Valve of size 50 mm dia complete all as specified and directed. |
| 31 | S&F Foot Valve of size 40 mm dia complete all as specified and directed. |
| 32 | Repair to existing old sluice valve of size 200 mm dia for check nut, spindle, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of sluice valve & spindle including fixing & testing complete all as specified and directed . |
| 33 | All as per ser item 31.00 here-in-before but of 150 mm dia |
| 34 | All as per ser item 31.00 here-in-before but of 100 mm dia |
| 35 | All as per ser item 31 here-in-before but of 80 mm dia |
| 36 | M&L for repair to leaking run lead joints in CI/DI spigot and socket end pipe line of 100 to 150 mm bore by providing new lead ,using good quality spun yarn, including necessary excavation, returning filling in trenches in any type of soil,bailing out water, and at any depth complete all as specified and directed.Note:- (i) Contractor shall be fully responsible for necessory excavation for jointing work required. T&P equipment, mechanical excavation work and man power at site requirement with making good disturbed surfaces of road/wall/floor etc and matching with existing surface shall be included in quoted rate.(ii) Required extra fittings/pipe shall be measured and paid separately. |
| 37 | M&L for repair to leaking GI pipe line of size 50 mm to 80 mm bore by providing necessary fitting such as socket, Tee, Elbow,etc including necessary excavation, returning filling in trenches in any type of soil,bailing out water, and any depth complete all as specified and directed.Note:- (i) Contractor shall be fully responsible for necessory excavation for jointing work required. T&P equipment, mechanical excavation work and man power at site requirement with making good disturbed surfaces of road/wall/floor etc and matching with existing surface shall be included in quoted rate.(ii) Required extra fittings/pipe shall be measured and paid separately. |
| 38 | All as per ser item 36.00 here-in-before but of size 20 mm to 40 mm bore pipe. |
| 39 | S&F cast iron fittings for spigot and socket ends for pressure pipe for water mains such as bends, tapers, tee pieces single branch, cross collar, caps and plugs suitable for upto 150 mm bore, all specifications as per IS-1538 (Pt-1 to 23)-1976 and all as specified and directed. |
| 40 | S&F Gun-metal, globe or gate valves, 50 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked),complete all as specified & directed. |
| 41 | All as per ser item No 39.00 here-in-before but upto 40 mm bore. |
| 42 | All as per ser item No 39.00 here-in-before but upto 25 mm bore. |
| 43 | All as per ser item No 39.00 here-in-before but upto 20 mm bore. |
| 44 | All as per ser item No 39.00 here-in-before but upto 15 mm bore. |
| 45 | S&F GI fittings given below medium grade ISI marked complete all as required at site and as directed:- |
| 46 | Elbow 15mm |
| 47 | Elbow 20mm |
| 48 | Elbow 25mm |
| 49 | Elbow 40mm |
| 50 | Elbow 50mm |
| 51 | Elbow 80mm |
| 52 | Socket 15mm |
| 53 | Socket 20mm |
| 54 | Socket 25mm |
| 55 | Socket 40mm |
| 56 | Socket 50mm |
| 57 | Socket 80mm |
| 58 | Union 15mm |
| 59 | Union 20mm |
| 60 | Union 25mm |
| 61 | Union 40mm |
| 62 | Union 50mm |
| 63 | Union 80mm |
| 64 | Elbow reducer 20 x 15mm |
| 65 | Elbow reducer 25 x 20mm |
| 66 | Elbow reducer 40 x 25mm |
| 67 | Socket reducer 25x20mm |
| 68 | Socket reducer 40x25mm |
| 69 | Socket reducer 40x20mm |
| 70 | Socket reducer 50x25mm |
| 71 | Nipple 15 x50mm |
| 72 | Nipple 15 x100mm |
| 73 | Nipple 20 x50mm |
| 74 | Nipple 20 x100mm |
| 75 | Nipple 25 x 50mm |
| 76 | Nipple 25 x 100mm |
| 77 | Nipple 40 x 50mm |
| 78 | Nipple 40 x 100mm |
| 79 | Nipple 50 x 50mm |
| 80 | Nipple 50 x 100mm |
| 81 | Tee 15mm |
| 82 | Tee 20mm |
| 83 | Tee 25mm |
| 84 | Tee 20x15mm |
| 85 | Tee 25x20mm |
| 86 | Tee 40x15mm |
| 87 | Tee 40x20mm |
| 88 | Tee 40x25mm |
| 89 | Tee 50x25mm |
| 90 | Dead plug 15mm |
| 91 | Dead plug 20mm |
| 92 | Dead plug 25mm |
| 93 | Dead plug 40mm |
| 94 | Dead plug 50mm |
| 95 | Lead wool |
| 96 | S&f in replacement CPVC pipes of 20mm dia,having thermal stability for hot & cold water supply,including all CPVC plain and brass threaded fittings, This includes joint of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed. |
| 97 | S&F in replacement CPVC pipes of 25 mm dia,having thermal stability for hot & cold water supply,including all CPVC plain and brass threaded fittings, This includes joint of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed. |
| 98 | S&F in replacement CPVC pipes of 50mm dia,having thermal stability for hot & cold water supply,including all CPVC plain and brass threaded fittings, This includes joint of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed. |
| 99 | S&F in replacement CPVC pipes of 40mm dia,having thermal stability for hot & cold water supply,including all CPVC plain and brass threaded fittings, This includes joint of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed. |
| 100 | S&F in replacement CPVC ball valve size 50 mm dia complete all as specified and directed. |
| 101 | S&F in replacement CPVC ball valve size 40 mm dia complete all as specified and directed. |
| 102 | S&F in replacement CPVC ball valve size 25 mm dia complete all as specified and directed. |
| 103 | S&F in replacement CPVC ball valve size 20 mm dia complete all as specified and directed. |
| 104 | S&F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe an of 20 mm dia fixed for the following sizes including taking out existing unserviceable complete all as specified and as directed.(Minimum weight 15 mm -142 gms/20 mm - 20 gms/25 mm - 455 gms/40 mm - 690 gms) |
| 105 | S&F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe an of 25 mm dia fixed for the following sizes including taking out existing unserviceable complete all as specified and as directed.(Minimum weight 15 mm -142 gms/20 mm - 20 gms/25 mm - 455 gms/40 mm - 690 gms) |
| 106 | S&F in repairs Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe an of 40 mm dia fixed for the following sizes including taking out existing unserviceable complete all as specified and as directed.(Minimum weight 15 mm -142 gms/20 mm - 20 gms/25 mm - 455 gms/40 mm - 690 gms) |
| 107 | Supply and Laying of Ductile iron pipes, Flanged type, Class K-9, with centrifugally cast Flanged (spun) with factory applied cement mortar lining inside the pipes and outside with zinc coating with suitable push on joint confirming to IS 8329/2000 and connected items complete all as specified & directed at site of following sizes :- |
| 108 | 150 mm bore |
| 109 | 100 mm bore |
| 110 | Supply and Laying of Ductile iron pipes, Class K-9, with spigot and socketed ends, centrifugally cast, flanged (spun) with factory applied cement mortar lining inside the pipes and outside with zinc coating with suitable push on joint confirming to IS 8329/2000 and connected items such as suitable size of nut, bolts, rubber washer etc complete all as specified & directed of following sizes :- |
| 111 | 150 mm bore |
| 112 | 100 mm bore |
| 113 | S&F DI fittings socketed / flanged / any type, heavy duty, such as bends, tapers, tees, collars, tail pieces, reducers, etc laid and jointed with suitable push on joints including taking down old unserviceable cast iron fittings etc complete all as specified and directed. |
| 114 | Supply of Chlorine and PH Test Kit for estimation of resudual chlorine in water comprises of plastic box, two tube, droper and colour filter for colour estimation complete complete all as specified and directed. |
| 115 | Supply only traditional calcium hypochlorite based Granular disinfectant for water treatment packed in 45 KG plastic Drum complete all as specified and directed. (Make : ALTOCH GP/Decliback/Aquafit) |
| 116 | ITEMS APPLICABLE FOR 'JOB B' |
| 117 | Dismantling and taking out the existing unserviceable mono block centrifugal pump set by disconnecting the cable connection suction and delivery pipe lines of the pump set, separate the motor from pump, transporting to civil workshop, removing the burnt out winding from slots, cleaning the stator and rotor slots with CTC and emery paper and rewinding , varnishing and heating the motor with as per existing size of new super enamelled copper winding wire and insulating by using class ‘B’ insulation keeping for drying, bring back to site, reassemble the motor and pump, fixing in position, connecting electric connections testing and commissioning for its satisfactory performance complete all as specified and as directed upto 5 HP capacity :- |
| 118 | All as per item No. 62 above but for Capacity of 7.5 HP three phase pump set. |
| 119 | All as per item No. 62 above but for Capacity of 10 HP three phase motor pump set. |
| 120 | All as per item No. 62 above but for Capacity of 12.5 HP three phase pump set. |
| 121 | All as per item No. 62 above but for Capacity of 20 HP three phase pump set. |
| 122 | All as per item No. 62 above but for Capacity of 20 HP to 30 HP three phase pump set. |
| 123 | Dismantling and taking out the existing mono block centrifugal type pump set for servicing after disconnecting/dismantling electric/suction and delivery pipe lines transporting the pump to a reputed workshop remetalling to shaft, replacement of ball bearing of approved make, replacement of water seal gland and complete servicing / check up and greasing, oiling, Painting etc, reassembling the pump and motor, transporting the same to its original location, fixing in position, connecting up electrical and pipe line connection, testing and commissioning for satisfactory smooth operation including taking down old unserviceable ball bearing/small parts complete upto 5 HP three phase pump set complete all as specified and as directed.Note : Spare parts to be replaced shall be measured and paid separately under relevant items of BOQ given below: |
| 124 | All as per item No. 68 above but for Capacity of 7.5 HP to 10HP three phase pump |
| 125 | All as per item No. 68 above but for Capacity of 12.5 HP to 20HP three phase pump |
| 126 | Supply only angular contact bearing |
| 127 | Supply only Lock nut S.S |
| 128 | Supply only Impeller CI |
| 129 | Supply only Line shaft SS |
| 130 | Supply only Bowl Assembly |
| 131 | Supply only Retainer Bearing |
| 132 | S&F in replacement Direct-on-line (DOL) starter in sheet steel enclosure for single phase 1 to 2 HP complete all as specified & directed.(Make : Lauritz Knudsen (Formerly L&T) type MF-1 single phase or Techno-commercially equivalent in Crompton Greaves/Siemens /GE) |
| 133 | S&F in replacement Direct-on-line (DOL) starter in sheet steel enclosure for three phase 7.5 to 10 HP complete all as specified & directed.(Make : Lauritz Knudsen (Formerly L&T) type MN-16 DOL or equivalent Crompton Greaves/Siemens /GE) |
| 134 | S&F in replacement of Direct on line panel starter with complete voltmeter/ameter inlcuding indicator suitable for mono block pumpset upto maximun 10 HP capacity Type MN 32 FASD suitable for Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph Relay Max range 20 - 33 Amps capacity complete all as specified & directed.(Make : Lauritz Knudsen (Formerly L&T) / Crompton Greaves/GE/ Seimens) |
| 135 | Taking out submersible pump sets of any capacity from borewell with connected pipe lines erected in bore well with the help of vehicles and all T&P required after disconnecting existing water and electric supply connections and shifting the pump set to local workshop for necessary repairs and refixing lowering after repair/rewinding of submersible motor and connecting the same complete all as specified and directed. Note: The cost of servicing , spares & rewinding shall be measured and paid separately under relevant items given below: |
| 136 | S&F for Rewinding the submersible motor of capacity 5 HP with super enamelled wire of existing gauge and weight in the coil terms with other materials for 3 phase 415 volts, 50Hz after cutting replacing of warn-out bolts and nuts including changing of bearings complete all as specified & directed. |
| 137 | All as per item No.81 above but for motor Capacity of 7.5 HP - 10 HP |
| 138 | M&L of Servicing of submersible pump sets 5 to 7.5 HP multistage self priming including painting with one coat of synthetic enamel paint and replacing of the required spares parts complete all as specified & directed. Note: The cost spares shall be measured and paid separately under relevant items given below: |
| 139 | Supply only Bearing of pump |
| 140 | Supply only Suction strainer |
| 141 | Supply only Suction Bush |
| 142 | Supply only Stage Casing Bush |
| 143 | Supply only SS Shaft |
| 144 | Supply only SS Sleeves |
| 145 | Supply only GM Impeller |
| 146 | Supply only NRV |
| 147 | Supply only SS Nut and Bolt with washer |
| 148 | S&F PVC insulated sheathed cable with multi stranded submersible copper conductor of size 3 core 10 sqmm for pump set including removing the old unservsible cable complete all as specified and directed. |
| 149 | S&F PVC insulated sheathed cable with multi stranded submersible copper conductor of size 3 core 6 sqmm for pump set including removing the old unservsible cable complete all as specified and directed. |
| 150 | S&F PVC insulated sheathed cable with multi stranded submersible copper conductor of size 3 core 4 sqmm for pump set including removing the old unservsible cable complete all as specified and directed. |
| 151 | M&L for overhauling & refurbishing of induction motors /booster motor /by carring out the following works including reassembling the same and testing complete upto 7.5 HP capacity and different capacities as under :- (a) Disconnection of power supply after proper electrical shut down, taking out the motor from foundation by and dismantling the coupling and transporting to workshop from site. (b) Dismantling the motor assembly, cleaning of winding for all traces of dust & grease and cleaning the inner surfaces by petrol, pre heating of stator in the heating chamber at 100 degree celcius for 4 hours and applying of bectol red finishing varnish over the winding complete all as specified and directed. Notes : Rates shall be inclusive for transportation expense also. |
| 152 | Supply, installation testing and commissioning of submersible pump with motor of 3 phase 415 Volts of cap 7.5 HP as per existing stage but up to 12 stage a complete all as specified and directed. (Make Kirloskar /Crompton) |
| 153 | S&F in replacement of ON load changeover 160 Amps, 4 pole, in sheet steel enclosure including complete connection of cables with necessary modification if required complete all as specified and directed. |
| 154 | S&F in replacement of MCCB 250 Amps MCCB , 3 pole, 36 KA rupturing capacity in the existing panel with necessary modification if reqd complete all as specified and directed. |
| 155 | All as per ser item 99 here-in-before but capacity of 250 Amps MCCB , 4pole, 36 KA rupturing capacity |
| 156 | All as per ser item 99 here-in-before but capacity of 200 Amps MCCB , 4pole, 36 KA rupturing capacity |
| 157 | All as per ser item 99 here-in-before but capacity of 200 Amps MCCB ,3 pole, 36 KA rupturing capacity |
| 158 | All as per ser item 99 here-in-before but capacity of 160 Amps MCCB ,3 pole, 36 KA rupturing capacity |
| 159 | All as per ser item 99 here-in-before but capacity of 125 Amps MCCB ,3 pole, 16 KA rupturing capacity |
| 160 | All as per ser item 99 here-in-before but capacity of 100 Amps MCCB ,3 pole, 16 KA rupturing capacity |
| 161 | S&F in replacement of water seal gland of exisitng monoblock pump set upto 30 HP capacity complete all as specified and directed. |
| 162 | M&L for Desilting/ cleaning of borewell including taking out and lowering of new/repaired submersible pump set of any size (5 HP to 12HP), 3 phase 400/415 Volts in 200/250 mm size tube well up to existing depth of bore complete all as specified and directed comprising following nature of work :-Dip connection existing pipe connection any size and removing electric connection. Erection of tripod/chain pulley block at site . Unscrewing the submersible pump and removing the same at site for relowering. Transporting the troly mounted DTH machine at site for flushing the bore well/further boring if required.Flushing the bore hole through compressor operating 120PSI after lowering the rig in length 1.5 mtr x 80 Nos continuously till clear water obtained not less than 6 hrs |
| 163 | M&L for construction of valve chamber in repairs of size 60x60x60cm of brick masonry valve pit of internal size 60x60x60cm with 230mm thick brick wall built in cement mortar 1:6, plain cement concrete foundation 1:4:8 type D2, plastering on brick surfaces 15mm thick in cement mortar 1:4 covered with MS plain sheet 3 mm thick duly fixed to MS frame size 40x40x6mm and duly embedded in plain cement concrete coping 5 cm thick plain cement concrete 1:2:4 type B1 with opening and locking arrangements including painting with two coat of synthetic enamel paint over one coat of primer complete all as specified and as directed. |
| 164 | M&L for construction of valve chamber in repairs of size 90x90x90cm of brick masonry valve pit of internal size 90x90x90cm with 230mm thick brick wall built in cement mortar 1:6, plain cement concrete foundation 1:4:8 type D2, plastering on brick surfaces 15mm thick in cement mortar 1:4 covered with MS plain sheet 3 mm thick duly fixed to MS frame size 40x40x6mm and duly embedded in plain cement concrete coping 5 cm thick plain cement concrete 1:2:4 type B1 with opening and locking arrangements including painting with two coat of synthetic enamel paint over one coat of primer complete all as specified and as directed. |
| 165 | S&F in replacement graphite gland packing, suitable for sluice valves or pump sets, fixed in position including taking down unserviceable gland packing complete all as specified and as directed. |
| 166 | S&F in repair spindle for sluice valve 200mm with GM check nut (as per sample) suitable complete all as specified and as directed. |
| 167 | S&F in repair spindle for sluice valve 150mm with GM check nut (as per sample) suitable complete all as specified and as directed. |
| 168 | S&F in repair spindle for sluice valve 100mm with GM check nut (as per sample) suitable complete all as specified and as directed. |
| 169 | S&F in repair spindle for sluice valve 80mm with GM check nut (as per sample) suitable complete all as specified and as directed. |
| 170 | S&F in replacement run lead joints for CI spigot and socket pipes and fittings for the size of 150mm bore complete all as specified and as directed. |
| 171 | S&F in replacement run lead joints for CI spigot and socket pipes and fittings for the size of 100mm bore complete all as specified and as directed. |
| 172 | S&F in replacement run lead joints for CI spigot and socket pipes and fittings for the size of 80mm bore complete all as specified and as directed. |
| 173 | S&F in repair single phase preventer ES-00 type for 3 phase motor upto 30 HP capacity-01 No complete all as specified and as directed. |
| 174 | S&F in repair digital ammeter with necessary CTs range 0-100 Amps square type complete all as specified and as directed. |
| 175 | S&F in repair digital voltmeter range 0-500 volts square type complete all as specified and as directed. |
| 176 | M&L for spray painting with synthetic enamel paint on old painted surfaces including necessary preparation of surfaces of centrifugal pump sets coupled to 30 HP motor and accessories at old pump house including marking the locations complete all as specified and as directed. |
| 177 | M&L for spray painting with synthetic enamel paint on old painted surfaces including necessary preparation of surfaces of centrifugal pump sets coupled to 25 HP motor and accessories at old pump house including marking the locations complete all as specified and as directed. |
| 178 | M&L for spray painting with synthetic enamel paint on old painted surfaces including necessary preparation of surfaces of centrifugal pump sets coupled to 12.5 HP motor and accessories at old pump house including marking the locations for complete all as specified and as directed. |
| 179 | M&L for spray painting with synthetic enamel paint on old painted surfaces including necessary preparation of surfaces of centrifugal pump sets coupled to 7.5 HP motor and accessories at old pump house including marking the locations complete all as specified and as directed. |
| 180 | M&L for spray painting with synthetic enamel paint on old painted surfaces including necessary preparation of surfaces of centrifugal pump sets coupled to 5/3 HP motor and accessories at old pump house including marking the locations for complete all as specified and as directed. |
| 181 | M&L for spray painting with synthetic enamel paint on old painted surfaces including necessary preparation of surfaces of centrifugal pump sets coupled to 2/1 HP motor and accessories at old pump house including marking the locations for complete all as specified and as directed. |
| 182 | M&L for spray painting with synthetic enamel paint on old painted surfaces including necessary preparation of surfaces of electric panel of the pump set equipments and accessories at old pump house including marking the locations complete all as specified and directed. |
| 183 | M&L for spray painting with synthetic enamel paint on old painted surfaces of suction/ delivery pipe lines of any size at pump houses including necessary preparation of surfaces complete all as specified and directed. |
| 184 | S&F in replacement Timer 3RP15761NP308K for pump sets complete all as specified and directed. (Make:Siemens or techno commercially equivalent of Lauritz Knudsen(formerly L&T)/ Legrand/ Schneider) |
| 185 | S&F in repair three phase VAFPF (Voltage, Amp, Frequency and Power factor meter) in pump house electric panels with accuracy class 0.5 operating voltage 420 Volts complete all as specified and as directed. |
| 186 | M&L for one coat of cement base paint on external surfaces of walls to semi under ground tanks complete including preparation of surface washing, rubbing down and stopping of old painted surfaces complete all as specified and directed. |
| 187 | M&L for one coat of cement base paint on external surfaces of walls to RCC over head reservoir portion above 15m complete including preparation of surface washing, rubbing down and stopping of old painted surfaces complete all as specified and directed. |
| 188 | Servicing of mechanical chlronome/dosing plants of any type (Gravity feed) of capacity 100 ltrs per hour installed at PUMP HOUSE locations complete all as specified and as directed.Notes: (a) The rates shall be deemed to include the cost of all spares such as washers of different size, socket head bolt, spacer, spring, spring plate, piston, dowl pin, gear plate, ball bearing, cam spacer, adjust, ment shaft, dial holder, adjusting knob, housing, Anti siphon valve, discharge valve assembly, suction valve assembly, foot valve assembly and other parts as necessary and required for the smooth and satisfactory working of the plant.(b) Each plant shall be serviced once in a month and each service done shall be measured as one Job. |
| 189 | S&F in replacement of power contactor MNX A1 of 16 Amp 415V AC rating, 03 pole,with 2NO+2NC Aux Contacts, Coil 230V,50HZ and including taking down of unserviceable contactor and making all electric connection, complete all as specified and directed. |
| 190 | S&F in replacement of power contactor MNX A1 of 20 Amp 415V AC rating, 03 pole,with 2NO+2NC Aux Contacts, Coil 230V,50HZ and including taking down of unserviceable contactor and making all electric connection, complete all as specified and directed. |
| 191 | S&F in replacement of power contactor MNX A1 of 32 Amp 415V AC rating, 03 pole,with 2NO+2NC Aux Contacts, Coil 230V,50HZ and including taking down of unserviceable contactor and making all electric connection, complete all as specified and directed. |
| 192 | S&F in replacement of over load relay of capacity 12-16 Amps as per existing make, range, direct / separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as specified and directed. |
| 193 | S&F in replacement of over load relay of capacity 6-10 Amps as per existing make, range, direct / separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as specified and directed. |
| 194 | S&F in replacement of over load relay of capacity 20-32 Amps as per existing make, range, direct / separate mounting on contactors, as required, with and incl taking down of unserviceable relay and making all electric connection, complete all as specified and directed. |
| 195 | S&F in replacement of phase failure relay 3 Ph 415V 6-32A as existing type with high voltage, low voltage and neutral fail protection, complete all as specified and directed. (Make Siemens/Schneider/ Lauritz Knudsen (Formerly L&T)) |
| 196 | S&F in replacement Motor protection circuit breaker 11A-16A 3RV1926-1B 415V Complete all as specified and directed. (Make Siemens/Schneider/Lauritz Knudsen (Formerly L&T) |
| 197 | S&F in replacement Motor protection circuit breaker 4.3A - 6.3A 3RV1786-2D 415V Complete all as specified and directed. |
| 198 | S&F in replacement selector switch 6A 3 pole 3 way complete all as specified and directed. (Make Siemens/Schneider/Lauritz Knudsen (Formerly L&T) |
| 199 | S&F in replacement push button, projecting head (push function) type, for controling the motors starters of cooling tower/water pumps etc complete all as specified and directed. |
| 200 | S&F in replacement of LED type indicator lamp of red/yellow/blue colour for phase indication, complete all as specified and directed. |
| 201 | M&L Plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in coping including use and waste of form work complete all as specified and directed. |
| 202 | S&F in replacement HDPE pipes of 25 mm dia,having pressure rating of pipe 6 kgf/cm2 lowering into the borewell including all T&P and vehicle required for taking down of old unsv pipe and fixing new pipe with all necessary fittings required and testing complete of joints including taking down old pipe complete as specified and directed. |
| 203 | S&F in replacement HDPE pipes of 40 mm dia,having pressure rating of pipe 6 kgf/cm2 lowering into the borewell including all T&P and vehicle required for taking down of old unsv pipe and fixing new pipe with all necessary fittings required and testing complete of joints including taking down old pipe complete as specified and directed. |
| 204 | S&F in replacement HDPE pipes of 50 mm dia,having pressure rating of pipe 6 kgf/cm2 lowering into the borewell including all T&P and vehicle required for taking down of old unsv pipe and fixing new pipe with all necessary fittings required and testing complete of joints including taking down old pipe complete as specified and directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |