Tender For Repair To Boundary Wall Fencing Hard Standing Plastering And Other Connected Work At Snco Mess 820.71 Rmu, 14 P&S, Begam Bazaar, Hq Ce (Af) Bamrauli, Hq Cwe (Af) Bamrauli At Af Stn Bamrauli Under Ge (Af) Bamrauli
Tender Overview
Project Description
Tender for Repair To Boundary Wall Fencing Hard Standing Plastering And Other Connected Work At Snco Mess 820.71 Rmu, 14 P&S, Begam Bazaar, Hq Ce (Af) Bamrauli, Hq Cwe (Af) Bamrauli At Af Stn Bamrauli Under Ge (Af) Bamrauli
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Jul-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 08-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of floor, hearth or wall tiling includinguding cement mortar bedding but not backing and rubbish off the premises, complete all as specified and directed. |
| 2 | M&L for non-skid Heavy duty endura tile 300x300x10-12mm thick coloured joint free in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6, complete all as specified and directed. |
| 3 | M&L for Chequered cement concrete tiles 300x300x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in cement mortar (1:6) including jointing with neat cement slurry mixing pigment to match the colour etc, complete all as specified and directed. |
| 4 | Demolition of PCC in ground floor & pavings n.exc 15 cm thickness below or above GL, complete all as specified and directed. |
| 5 | M&L 75 mm thick type D-2 1:4:8 (using 20mm graded crushed stone aggregates) as in sub base, complete all as specified and directed. |
| 6 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 7 | M&L for 100mm thick (1:4:8) type D-2 using 40mm graded crueshed store aggregate as in sub base of floor, complete all as speified and directed. |
| 8 | M&L for Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 9 | Demolition of cement concrete (reinforced) as in manhole cover, complete all as specified and as directed by Engineer-in-charge. |
| 10 | M&L for PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in foundation of manhole, complete all as specified and directed. |
| 11 | M&L for RCC type B1 1:2:4 (using 20mm grded crused stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 12 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 13 | Demolition of brickwork or stone boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles and M& L Brick work with subclass \\"B\\" bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 of using class designation 100 of bricks in lieu of 75, complete all as specified and directed. |
| 14 | M&L for Brick work with sub class 'B' brick straight or urved on plan 6m mean radius built in CM 1:6, but except bricks, complete all as specified and directed by Engineer-in-Charge.Note : Old retrived Bricks shall be used demolished under respective items. |
| 15 | Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster inluding M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work, surfaces finished even and fair without using extra cement and M&L for two coat of oil bound distemper on newly plastered surface on wall over a coat of primer all as specified incl preparation of surface, complete all as specified and directed. |
| 16 | M & L for complete removal of existing surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over surfacen of wall and application of paint through mechanical means, complete all as specified and directed. |
| 17 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. |
| 18 | S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensil strength of 550 Mpa as in roof covering to wall fixed with self tapping screws, complete all as specified and directed. |
| 19 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensil strength of 550 Mpa as in roof covering to wall fixed with self tapping screws, complete all as specified and directed. |
| 20 | Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/ slabs/blankets, any thickness, includinguding cover fillets and M&L for 6 mm thick plywood, grade BWR, type BB, fixed with nails, fixed in repairs, complete all as specified and directed. |
| 21 | Dismantling of wall and ceiling boards (fibre, pulp, insulation. etc) or insulation boards/ slabs/blankets, any thickness, includinguding cover fillets and Providing & fixing false ceiling at all height with GRG (Glass Fibre reinforced Gypsum) false ceiling tile of size 595x595mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99%,NRCO.50 to 0.75 as per IS 8225:1987, non combustible as per BS 476(Part4)-1970 and light reflectance of 85% (minimium) to be laid in true horizontal level suspended on interlocking metal T-grid of hot dripped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per Sqm including both sides) comprising of main T-runner of size 15x32mm of length 1200mm and sectinally intermediate cross T of size 15x32mm of length 600mm to form grid module of size 600mmx600mm, suspended from ceiling using galvanised mild steel items (galvanised @80 grams per Sqm) i.e. 50mm long,8mm outer diameter M-6 dash fastners 6mm dia fully threaded hanger rod upto 1000mm length and L- shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing, complete as per direction of the Engineer in Charge. |
| 22 | S&F in repair for hollow PVC wall panelling consisting of 10mm thick any colour or pattern single side prelaminated PVC sheet inclusive of solvent cement and fixing at site on PVC frame, complete all as specified and directed. |
| 23 | Demolition of reinforced cement concrete any description, complete all as specified and directed. |
| 24 | M & L for Pre-cast cement concrete type B-1 (1:2:4) (using 20mm graded crushed store aggregate) as in manhole cover slabs set in cement mortar 1:6 including necessary form work, complete all as specified and directed. |
| 25 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, complete all as specified and directed. |
| 26 | All as per item No. 25 here-in-before but, post embedded in concrete, complete all as specified and directed. |
| 27 | Dismantling fencing wire mesh, any type, complete all as specified and directed. |
| 28 | Excavation in post holes n.exc 0.5 Cum and getting out in hard/dense soil, complete all as specified and directed. |
| 29 | S&F for Angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 (R), complete all as specified and directed. |
| 30 | S&F for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 (R), complete all as specified and directed. |
| 31 | Supply only chain link fencing mesh size of 100 x 100 mm of 4mm dia galvanised wire, complete all as specified and directed. |
| 32 | Fixing only chain link fencing incl line wire any mesh size and type of standrds rails, straining bolts incl provn of binding wire, complete all as specified and directed. |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 34 | Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 35 | All as per item No. 34 here-in-before but, but 6mm to 8mm dia, complete all as specified and directed. |
| 36 | All as per item No. 34 here-in-before but, 5mm dia and over upto & incl 8 mm dia as in stirrups, complete all as specified and directed. |
| 37 | S&F in repair of Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and directed. |
| 38 | S&F in repair of Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, complete all as specified and directed. |
| 39 | M & L for PCC 1:2:4, type B 2 using 40 mm graded stone aggregate in foundation and mass concrete/ filling, complete all as specifed and directed. |
| 40 | S&F for mild steel framed work such as grills grating etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars, barrel iron doors ladders framed balusters walk ways railing frame work of water tanks, hole fast and similar work confirming to Fe -290 Gde-E-165, complete all as specified and directed. |
| 41 | M&L for RCC M-25 as in (design mix)Columns, pillars, piers, posts and struts using 20mm graded crushed store aggregate, complete all as specified and directed. |
| 42 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed. |
| 43 | M&L for 2 coats of synthetic enamel paint over one coat of red oxide primer incl preparation of surfaces over 10cm width or girth, complete all as specified and directed. |
| 44 | S&F in repair concertina coil 600-800mm dia (in stretched position) hot dip galvanized steel ire coated with CLR anti corrosive paint, making diamond shape with the help of dovetail clips (18 SWG) fixed over and including razorwire, medium barb, hot dip galvanized steeel wire razor wire with angle iron. The concentina coil to be fixed with razor wire, at points wherever coil touches bottom of razor wire with the help of hog rings 914 SWG) including all fittings like fasteners clips, steel lug rings etc, complete all as specified and directed. Note :Stretch length of each coil shall be 6 mtr. |
| 45 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed. |
| 46 | M&L for PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concrete, complete all as specified and directed. |
| 47 | M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, complete all as specified and directed. |
| 48 | M&L for Forming 12mm thick Expansion joints of 150mm thick filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing com pound, Grade ‘A', complete all as specified and directed. |
| 49 | M&L for 20mm thick screed bed or bedding layer in CM 1:6, complete all as specified and directed. |
| 50 | S&F for 35mm thick precast PCC louvers and jallies in 1:2:4 type B-0 (using 12.5 graded crushed stone aggregate) incl suitable reinforcement all moulding etc set in CM 1:4, complete all as specified and directed. |
| 51 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender