| 1 | Excavating in trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth and getting out in Soft/ Loose Soil, complete all as specified and as directed. |
| 2 | Returning, Filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 3 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point, complete all as specified and as directed. |
| 4 | Horizontal Boring for passing GI protection pipe up to 100 mm bore (dia), under road / foot path, not exc. 10.00 metre in a single length, complete all as specified and as directed. |
| 5 | M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thick -ness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.(NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid for). |
| 6 | Taking down/out unserviceable or serviceable LT UG Cables of nominal Cross Sectional Area 35sqmm 3.5 core and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed. |
| 7 | All as per Item No. 6 above, but Nominal Cross-Sectional Area 25 Sqmm 4 Core. |
| 8 | All as per Item No. 6 above, but Nominal Cross-Sectional Area 16 Sqmm 4 Core. |
| 9 | All as per Item No. 6 above, but Nominal Cross-Sectional Area 10 Sqmm 2 Core.(NOTE for Item No.6 to 9 : Earth Work shall be Measured and Paid for separately under relevant Items). |
| 10 | Re-Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 35 sqmm 3.5 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. |
| 11 | All as per Item No. 10 above, but Nominal Cross-Sectional Area 25 Sqmm 4 Core. |
| 12 | All as per Item No. 10 above, but Nominal Cross-Sectional Area 16 Sqmm 4 Core. |
| 13 | All as per Item No. 10 above, but Nominal Cross-Sectional Area 10 Sqmm 2 Core.NOTE : FOR ITEM NO. 10 to 12 : { PVC/XLPE insulated PVC Bedded (Heavy duty), Galvanised Steel Strip or Wire Armoured, Electric Power Cable shall be issued under SCHEDULE ‘B’ as ‘FREE-FOR-LAYING/ FIXING’}. |
| 14 | Supply Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 10 sqmm 2 core and Testing, including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. |
| 15 | Supply Laying or Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross-Sectional Area 35 Sqmm 3½ core Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. |
| 16 | All as per Item No. 14 above, but Nominal Cross-Sectional Area 25 Sqmm 4 Core. |
| 17 | All as per Item No. 14 above, but Nominal Cross-Sectional Area 16 Sqmm 4 Core. |
| 18 | S&F Sub-Class B brick, well burnt, laid breadth-wise along the axis of Cable laid in Trenches over Sand Cushion laid for UG Cable Protection, complete all as specified and as directed. |
| 19 | Re-laying only old Bricks in Trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 1 here-in-before), complete all as directed. |
| 20 | M&L for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:2:4) by using 20 graded stone aggregate for the fixing the pipe, complete all as directed by the Engr-in-Charge at site. |
| 21 | Taking down/out unserviceable GI / HDPE/Polyethylene flexible pipes of any descriptions, laid in trenches and/or fixing with Walls/Poles complete all as specified and as directed. |
| 22 | S&F Galvanised Iron Pipe 50mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 23 | S&F Galvanised Iron Pipe 40mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 24 | S&F Galvanised Iron Pipe 32mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 25 | M&L Straight Through (Heat shrink) Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor, Nominal Cross-Sectional area exc. 25 Sqmm but not exc. 50 Sqmm, 3.5/4 Core and Testing complete all as specified and as directed. |
| 26 | M&L for street light bracket (suitable for fluorescent/ sodium vapour/mercury vapour fittings upto 1.5 RM make out of GI pipe of light grade up to 40 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape and designed including taking down old corroded one all as directed and specified by Engineer-in-charge. |
| 27 | M&L for street light bracket (suitable for fluorescent/ sodium vapour/mercury vapour fittings upto 1.5 RM make out of GI pipe of light grade up to 25 mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape and designed including taking down old corroded one all as directed and specified by Engineer-in-charge. |
| 28 | Supplying and laying PVC insulated and FR PVC sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 electric control cable with copper conductor, 1100 volts grade, cross sectional area 1.50 sqmm 3 core including taking down U/S cable, complete all as specified and directed. |
| 29 | S&F Cable Junction Box 155X210X92mm in size, made out of thermoplastic sheet having IP 66/69 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat aluminium strip clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed.Make : Cat No. DK 1616 G of HENSEL or equivalent model in SPELSBERG/RITTAL/SINTEX. |
| 30 | S&F Cable Junction Box 130X180X77mm in size, made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 - 2 nos) fixed on poles with flat aluminium strip clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed.Make : Cat No. DK 1010 G of HENSEL or equivalent model in SPELSBERG/RITTAL. |
| 31 | S & F in replacement decorative LED post top 40 watt fittings IP-65 protection including with all accessories complete along with GI Pipe of 40mm dia (light grade) of 0.5m length shall be fixed on the post top lantern including all necessary PCC works , after taking down old unserviceable light fittings all as specified and directed by Engr-in-charge. Make :- Crompton (Cat No.- LPTO-40-CDL) or equiv make in PS. |
| 32 | S & F in replacement garden light fitting with inverted pyramid Tripod type LED bollard with soft 360 degres light 10 Watts. Foundation for the fittings shall be os sizes 250 X 250 X 450 mm with PCC-1 (1:2:4) type B-1 (using 20 mm graded stone aggregate), after taking down old unserviceable light fittings all as specified and directed. Make- Crompton (Cat No.- LBLSN-10-CDL) or equiv make in PS. |
| 33 | Supply and Fixing in replacement street light LED luminaries with low wattages with pressure die cast housing with heat resistant toughened glass and high power LEDs with secondary optics with IP- 66 protection of cap 30 Watts, after taking old unserviceable light fittings all specified and directed by Engr-in-Charge. Make :- Crompton (Cat No.- LSTS-30-CDL-M) or equiv make in PS. |
| 34 | Supply and Fixing in replacement street light LED luminaries with low wattages with pressure die cast housing with heat resistant toughened glass and high power LEDs with secondary optics with IP- 66 protection of cap 45 Watts, after taking old unserviceable light fittings all specified and directed by Engr-in-Charge. Make :- Crompton (Cat No.-CRP-409-45-57-SL-GL-NSG ) or equiv make in PS. |
| 35 | Supply and Fixing in replacement street light LED luminaries with low wattages with pressure die cast housing with heat resistant toughened glass and high power LEDs with secondary optics with IP- 66 protection of cap 60 Watts including 10 KV SPD, after taking old unserviceable light fittings all specified and directed by Engr-in-Charge. Make :- Crompton (Cat No.- CRP-409-60-57-SL-GL-NSG) or equiv make in PS. |
| 36 | Supply and Fixing in replacement street light LED luminaries with low wattages with pressure die cast housing with heat resistant toughened glass and high power LEDs with secondary optics with IP- 66 protection of cap 70/72 Watts including 10 KV SPD, after taking old unserviceable light fittings all specified and directed by Engr-in-Charge. Make :- Crompton (Cat No.- CRP-409-70-57-SL-GL-NSG) or equiv make in PS. |
| 37 | S & F as in repair for 120 Watt LED ( CCT 5700 - 6500 K ), cradle / surface mounted Flood light made of aluminium die cast housing with power coating, having excellent thermal management along with IP 66 protection with clamp as per site requirment complete all as specified and directed by Engr-in-charge. with efficiency of 110 lm/W and lumen output of >= 11000 lumen. |
| 38 | S & F as in repair for 150 Watt LED ( CCT 5700 - 6500 K ), cradle / surface mounted Flood light made of aluminium die cast housing with power coating, having excellent thermal management along with IP 66 protection with clamp as per site requirment complete all as specified and directed by Engr-in-charge. with efficiency of 110 lm/W and lumen output of >= 11000 lumen. Please Enable Macros to View BoQ information |
| 39 | S & F as in repair for 150 Watt LED ( CCT 5700 - 6500 K ), cradle / surface mounted Flood light made of aluminium die cast housing with power coating, having excellent thermal management along with IP 66 protection with clamp as per site requirment complete all as specified and directed by Engr-in-charge. with efficiency of 110 lm/W and lumen output of >= 11000 lumen. Please Enable Macros to View BoQ information |