| 1 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re-plastering or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in-charge. |
| 2 | Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:- Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sqm and below. |
| 5 | Dismantling G.I sheet roofing including ridges, hips, valleys, gutters wind ties etc. including dismembering and stacking of serviceable materials and unserviceable materials separately with all lifts and upto a lead of 50 m etc.complete as per direction of the Engineer- in-charge. |
| 6 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead |
| 7 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 8 | Demolishing brick work including stacking of serviceable materials and disposal of unserviceablematerials with all lifts and upto a lead of 50m etc. complete as per direction of the Engineer- in-charge:- |
| 9 | Dismantiling steel work in built up section in channels,angles,tees,bolts,nuts,cutting rivets,welding including dismembering nad stacking of secviceable materials and unserviceable materials separately with all lifts and upto a lead of 50m etc. complete as per direction of the engineer- in- charge. |
| 10 | Dismantling W.C. Pan of all sizes including disposal ofdismantled materials including malba all complete as per directions of Engineer-in-Charge. |
| 11 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m- All kinds of soil |
| 13 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 14 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering ---All work upto plinth level: 1:4:8 (1 Cement: 4 fine sand: 8 graded stone aggregate 40 mm nominal size) |
| 15 | 1:5:10 (1 Cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) |
| 16 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level: 1:1/2:3 (1 Cement 1/2 fine sand: 3 graded stone aggregate 20 mm nominal size) |
| 17 | First class brick work in foundation and plinth including cost of all materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 18 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 19 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 20 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. hermo-Mechanically Treated bars of grade Fe-500D or more |
| 21 | Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns. |
| 22 | Columns, piers, abutments, pillaras, posts and struts. |
| 23 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : Local Teak Wood |
| 24 | Providing and fixing M.s grills of required pattern in frames of windows etc. with M.s flats, square or round bars etc. all complete. Fixed to steel windows by welding |
| 25 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : (i)Local Teak Wood |
| 26 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 27 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smoothouter integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 28 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frameinsert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover mouldingshall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 29 | Providing 40 × 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30 × 10 × 15 cm 1:3:6 mix (1 cement : 3 fine sand : 6 graded stone aggregate 20mm nominal size) |
| 30 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x 16 mm |
| 31 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 300 x 10mm |
| 32 | 150 X 10mm |
| 33 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm |
| 34 | 100mm |
| 35 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :-For fixed portion of approved quality. Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 36 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):-Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodiccoating of grade AC 15) |
| 37 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :-With float glass panes of 5.5 mm thickness ( weight not less than 13.75 kg / sqm ) |
| 38 | Providing and fixing stainless steel ( SS 304 grade ) adjustable friction window stay of approved quality with necessary stainless steel screws etc. to the side hung windows etc. complete as per direction of Engineer-incharge:- |
| 39 | Providing and fixing aluminium tubular handle bar of 32 mm outer dia, 3.0 mm thick and 2100 mm long withStainless Steel screws etc. of approved quality complete as per direction of Engineer-in-charge:-Anodised aluminium of grade AC 15 ). |
| 40 | Providing and laying 1st class quality vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 - 2017, of approved make, in all colours and shades, laid over 20mm thick cement mortar 1:4 (1 cement : 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. all complete asper direction of the Engineer-in-charge..Glazed Vitrified Tiles (Glossy / Mat Finish/ Anti-Skid) Size of tile 600 mm x 600 mm |
| 41 | Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 fine sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade etc. all complete as per direction of Engineer-in-charge. 8mm thick Rajnagar marble tiles (polished) |
| 42 | Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 43 | Providing and fixing false ceiling at all height includingproviding and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, Including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge with: |
| 44 | 15 mm cement plaster on the rough side of single or half brick wall of mix: Cement mortar 1:6 ( 1 Cement : 6 fine sand ) |
| 45 | 12 mm cement plaster mix: Cement mortar 1:6 (1 cement : 6 fine sand) |
| 46 | Neat cement punning |
| 47 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 48 | Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade.[payment shall be made after submission of Test certificate issued by the Manufacturer] |
| 49 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 50 | Applying priming coat [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 51 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer].Two or more coats on new work |
| 52 | Providing and fixing in position wall panelling at all heights with 6 mm thick BWP ply board lapping with 4 mm thick Teak Veneer of approved quality in outer face, decorative teak wood bead (50 x 40 ) at top and skirting (150 x 25), comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally ply board are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm all complete as per manufacturer's specification as per direction of Engineer-in-Charge all complete. |
| 53 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Vitreous china Orrisa pattern W.C. pan of size580x440 mm with integral type foot rests. |
| 54 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 55 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:Flat back wash basin of size 550x400mm. |
| 56 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Semi rigid pipe 32 mm dia |
| 57 | Providing and fixing soil, waste and vent pipes:100 mm dia.Sand cast iron S&S pipe as per IS: 1729. |
| 58 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete |
| 59 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability forhot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm nominal outer dia .Pipes. |
| 60 | 20 mm nominal outer dia .Pipes. |
| 61 | 40 mm nominal outer dia .Pipes. |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia .Pipes. |
| 63 | 40 mm nominal outer dia .Pipes. |
| 64 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 65 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore |
| 66 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 67 | Providing and fixing Precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning etc. all complete as per direction of Engineer-in-charge. In dark shade using ordinary cement Please Enable Macros to View BoQ information |