| 1 | PART A (CIVIL WORKS):- Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge in All kinds of soil : |
| 3 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres - 80 % All kinds of soil |
| 4 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres - 20 % Ordinary rock : |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size (Complete Job) |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level.1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 8 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 9 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) - complete job |
| 10 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) - complete job |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) - complete job |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls: Under 20 cm wide |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts. |
| 17 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. - complete job |
| 18 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : cement mortar 1:6 (1 cement : 6 coarse sand ) |
| 19 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 20 | Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 21 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 22 | 12mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 23 | 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 24 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 25 | 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 27 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level (Complete Job) |
| 29 | Providing and laying 60mm thick factory made cement concreteinterlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. (Complete Job) |
| 30 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete (Complete Job) Size of tile 600x600 mm |
| 31 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brickhoney comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 32 | Providing/fixing kharkana-complete job excluding mesh. |
| 33 | Providing/fixing Truss Pulley including all necessary screws/tools/fitting etc. - complete job. |
| 34 | Providing and fixing Stainless Steel Wire Rope Cable of 5 mm Dia Galvanised including clamps etc for binding.-Complete job |
| 35 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 36 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in charge. Made of G.I. wire of dia 4 mm |
| 37 | Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 38 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. L.S. |
| 39 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.(Complete job) |
| 40 | Providing and fixing standard 25mm high-security toughened glass of size 2.50m x 2.50m of approved brand and manufacture including providing and fixing top and bottom pivot and fixing arrangement and making necessary holes etc as per direction of Engineer in charge including all fittings, carriage and labour - Complete job) |
| 41 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. L.S. |
| 42 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 43 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 75 mm |
| 44 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 110 mm |
| 45 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° - 75 mm |
| 46 | Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° - 110 mm |
| 47 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm |
| 48 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. 250x10 mm |
| 49 | Providing and fixing ISI marked 85 mm x 42 mm oxidized M.S. pull bolt lock conforming to IS: 7534 with necessary screws, bolts, nut and washers etc. complete. |
| 50 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete : 125 mm |
| 51 | Providing and fixing ISI marked M.S. sliding gate wheels with all necessary screws, fitting etc. complete job |
| 52 | Providing and fixing welded mesh 25 mm x 25 mm (square mesh) complete job |
| 53 | Providing and fixing M.S. Mosquito mesh complete as per the direction of Engineer-in-charge. Stainless Steel Mosquito Net For Window - complete job |
| 54 | Providing and fixing M.S tubular frames for doors, windows, ventilators and cupboard with rectangular /L-type sections, made of 1.60 mm thick M.S Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of C.C. 1:3:6 (1cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size) . |
| 55 | Providing and fixing 25 mm white thermacol layer in which toughened glass is placed - complete job . |
| 56 | Provision for design, investigation and carrying out various field tests such as Safe Bearing Capacity ( up to depth of 10 m) and other tests as required at site. The contractor shall submit design/drawing of the building, paddock(ISMC 150 - its depth of foundation), truss etc. as required by the Engineer - in - charge duly vetted from the Competent Authority (DIQC/Govt. Institution) - complete job. L.S. |
| 57 | Carriage of materials from source to site of work by M.T. - Sand av. |
| 58 | Carriage of materials from source to site of work by M.T. - Bajri av. |
| 59 | Carriage of materials from source to site of work by M.T. - Brick |
| 60 | Carriage of materials from source to site of work by M.T. - Earth - 50% in 500 m |
| 61 | Carriage of materials from source to site of work by M.T. - Earth - 30%% in 1.0 Km |
| 62 | PART B (ELECTRICAL WORKS):- Wiring for Light point/Exhaust Fan/ Wall Fan/Ceiling fan Point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed (underground) including PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm (excluding the cost of earth wire). FR PVC insulated multistrand copper conductor single core cable etc as required |
| 63 | Wiring for 6/16 amp switch socket outlet power point with 3x4mm sq (P+N+E) FR PVC insulated 1100 volt grade multistrand copper conductor wire concealed/recessed manner through fresh 25mm dia PVC conduit including cost of cutting/making good chases in brick work rough plastering & including the cost of supplying & fixing mounted 4no.16amp modular 5/6 pin combined socket outlet along with 16 amp modular control switch both mounted on GI box etc in each switch box and to be completed as per specification and as required including bend, socket etc. |
| 64 | Circuit wire to be laid through in Fresh PVC conduit for sub mains using following sizes of multistrand PVC insulated copper wire including the cost of PVC conduits complete job. a) 2x2.5 sq. mm + 1x1.0 sq. mm earth wire |
| 65 | Circuit wire to be laid through in Fresh PVC conduit for sub mains using following sizes of multistrand PVC insulated copper wire including the cost of PVC conduits complete job. b) 2x6.0 sq. mm + 1x1.0 sq. mm earth wire |
| 66 | Circuit wire to be laid through in Fresh PVC conduit for sub mains using following sizes of multistrand PVC insulated copper wire including the cost of PVC conduits complete job. c) 2x10 sq. mm + 1x1.0sq. mm earth wire |
| 67 | Providing and fixing of LED of standard quality and make with desired wattage including deep concealed box of standard quality complete. |
| 68 | Supplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) 2x24 way, Double door |
| 69 | Supplying and fixing following rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) MCB double pole 10 to32 A |
| 70 | Supplying and fixing following rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. b) MCB 4Pole 63 A |
| 71 | Providing, laying testing and commissioning of double run 35 mmsq 3 ½ core XLPE Al. cable Armored cable in existing duct/Rack. |
| 72 | Supplying and making end termination for following size of cables 3.5 /single core PVC insulated and PVC sheathed / XLPE aluminium conductor cable/ single core copper wire of 1.1 KV grade as required. (dowels make) |
| 73 | Providing/installation, testing and commissioning of Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 74 | Providing and laying of 25mm x 3mm Copper earthing strip including galvanized nut and bolts as per site requirement. Please Enable Macros to View BoQ information |