| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and cleaning and levelling the site etc.,complete - Narrow Foundations - First Depth - Upto 2m |
| 2 | For Plinth beam |
| 3 | For Footings |
| 4 | Supplying and filling in foundation and basement with Crusher Stone dust in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. |
| 5 | Plain Cement Concrete 1:5:10 (one part of cement, five part of Crushed Stone Sand (M- Sand) and ten part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 6 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation |
| 7 | For Plinth beam |
| 8 | For Column |
| 9 | For Plain Surface |
| 10 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - |
| 11 | Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors as per standard specification. |
| 12 | Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9\\" X 43/8\\"X 2 3/4\\" including finishing, curing, etc., complete complying with standard specification - 100CFT |
| 13 | Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications |
| 14 | Supplying and filling the basement with Good Earth filling in layers of not more than 15cm thick well rammed watered and compacted - etc., complete complying with standard specification. |
| 15 | Fabricating supplying and fixing of pre painted galvanium colour sheets with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 16 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 17 | Fabrication and Supply of Iron Sheet Door of size 1.20 m X 2.10 m using 1 ¼ x 1 ¼ x ¼ Iron Angle for Door Frame and using 1x1x ¼ iron angle Door shutter frame for vertical, horizontal members and strengthened by stiffeners using 16Gauge G.I sheet including welded with 6nos of hold fasts, 2nos of Tower bolts, 1 No. of All drop, 2 Handles & 3 inches with One coat of best quality Red oxide primer including cost and conveyance of all material and all labour charges and all other incidental charges etc. completed as per standard specification. |
| 18 | UPVC Ventilator Specification: Supplying and fixing UPVC(Un-Plasticized Polyvinyl Chloride) Louvered Ventilatorsof from the profile the size of outer frame 60mm x 58mmand shutter profile size of 60 x 78mm both profiles arereinforced with GI/1mm 125GSM and 100% corrosionfree, the profile are multi chambered sections with wallthick of 2mm. The EPDM rubber (black colour) coveredwith all over the edges of frame and shutter. The cornersand joints should be welded and cleaned. Radiationspin headed glass 4mm thick should be provided in thelouvers. The window should be fixed to the wall with100% packing with screws and silicon packing all roundthe frames. The ventilator should be got approved fromthe Executive Engineer before use on work |
| 19 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with 'P' trap or 'S' trap confirming to IS:2556 - Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 20 | Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelain low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting |
| 21 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 22 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over one coat of red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 23 | Suppling and fixing in position 15mm diameter brass / C.P screw down tap / pillar tap / swan neck tap (heavy duty) of approved make conforming to I.S.specifications and quality including cost of shellac, thread etc.complying with standard specifications and including cutting and threading wherever necessary |
| 24 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement |
| 25 | Dadooing walls with Glazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed etc., complete as per standard specification |
| 26 | Supplying and fixing best approved quality Brass C.P anodised Towel rail 600mm. long and 20mm Diameter with brackets of same material including cost of Teak-Wood plugs and C.P.Screws etc., complete complying with standard specifications |
| 27 | Supply and fixing of PVC. Nahini / Floor Trap with stainless Steel Gratings - 100 mm x 75 mm including all charges etc, complete as per standard specification. |
| 28 | Supplying laying and jointing P.V.C pipes (6Kg/SqCm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessary scaffolding charges. |
| 29 | 20mm Dia PVC Pipe |
| 30 | 25mm HDPE Hose Pipe |
| 31 | Supplying and fixing in position best approved of BIS quality PVC Soil waste pipes having a pressure of 6 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 32 | Supply and delivery of 2000 lit capacity and fixing of HDPE tank as per IS 12701/1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,complete as per standard specification. |
| 33 | Wiring with 2 x 1.5 sqmm (22 / 0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For electronic regulator). SD 23 |
| 34 | Supplying and laying of PVC insulated, PVC sheathed, armoured, LTUG cable of size 3.5 core 16 sqmm Al.cable clamped on walls etc, complete as per standard specification |
| 35 | Supply and run of 2 of 4sqmm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG Cu wireand making good of the concealed portion with suitable colour (SD57) |
| 36 | SupplyandfixingofTNEBmeterboardsuitablefor32Asinglephaseserviceconnectionwith32Afuseunit(500V)32Aneutrallinkandearthlink(1\\"x1/8\\"copperflat)onTWplankofsize375mmx300mmx19mmwithsupportingTWreepersof1\\"thickaneithersidewithpaintingwithsuitableboltandnutsforfixingtheTWplankonwallwithearthconnectionandinterconnectionwith7/20PVCinsulatedcopperwirefromEBmetertofuseunitwith1No40Amp30MA Double Pole RCD / RCCB (Higher End) with suitable necessary connection |
| 37 | Conducting physical survey for identification of suitable location for borewell including the loading, unloading and transporting charges for machineries etc., complete as per standard spedifications. |
| 38 | Drilling of 150mm dia Vertical bore in hard rock area using DTH RIG including labour charges for inserting casing pipe assembly in the drilled hole including the transporting charges for the rig and supporting vehicles etc complete |
| 39 | Supply of 150mm dia PVC casing pipe with including cost and conveyance of pipes to work site and all handling charges etc complete TWAd SOR P.14D |
| 40 | Supply of 200mm dia PVC casing pipe with including cost and conveyance of pipes to work site and all handling charges etc complete TWAd SOR P.14D |
| 41 | Supply and delivery of 63mm dia HDPE pipes PE 100 AS PER IS/4984/2016 (Pre -Comp[ouded Resin) PN 8 including cost and conveyance of materilas to work site etc completed as per satndard Specification.(TWAD SOR 2025-26 Page No 16 Uniquue code No WD -M0205) |
| 42 | supply and delivery of clear water vertical wet type submercible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 star rated capable of discharging noted LPM against head of water column due to all causes.The pump shall be with stainless steel shaft and dynamically balanced bronze or cast SS impeller ,brass screws and CI FG 200 Grade pump bowl /diffuser with ISI mark.The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirred cage induction motor as per IS 9283/1995 as amended there after ,suitable for operation in AC three phase 415V+/- 10% ,50 H2 +/- 5% without panel board (TWAD SOR 2025-26 Page No 119 Clause 3.1 Unique code WD -M1632)(75 pmx175m 5HP) |
| 43 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/-5%) and 415V (+/-10%) including 3 pole magnetic contactor with under voltage release - 3 Nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Stan- dard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately).(TWAD SOR 2025-26Page No 120 clause 11.20 Unique code WD -M1915)7.50HP |
| 44 | Supplying and fixing of PVC insulated and sheathed 3 core 4sq.mm Flat type Copper cable cofirming to IS 694/ 1990 and including cost and conveyance of all materials to site and labour charges etc, complete as per standard specification.(TWAD SOR 2025-65 page No140 Clause 12.1 ,Unique code WD-M1975) |
| 45 | Labour charges for the erection of submersible pump set in bore well/open well including fixing and jointing submersible cable with proper clamps up to the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges up to the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventer, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pump set and trail run for 10 days. (TWAD SOR 2025-26 Page No 225-226 ,ll Rates of works (E -Miscellaneous Worksitems Unique code 17 c WD -W0872)above 5.00HP to 10.00HP |
| 46 | Supply and delivery of PVC & GI Pipe and specials and other jointing materials and including cost and conveyance to work site and handling labour charges etc complete |
| 47 | 50mm Dia Flange Set (Unique code WD-M0597 TWAD SOR 2025-26 Page No 36) |
| 48 | 50mm dia GI Hex Nipple (Unique code WD-M0599 TWAD SOR 2025-26 Page No 36) |
| 49 | 50mm dia GI Elbow (Unique code WD-M0594 TWAD SOR 2025-26 Page No 36) |
| 50 | 50mm dia GM Gate Valve(Unique code WD-M0618 TWAD SOR 2025-26 Page No 37) |
| 51 | 50mm Dia GM Non Return Valve(Unique code WD-M0619 TWAD SOR 2025-26 Page No 37) |
| 52 | 50mm dia MS Clamp set (Unique code WD-M0617 TWAD SOR 2025-26 Page No 36) |
| 53 | Nylon Rope (PWD SOR 2025-26 Page No 169 Unique Code No M-1072) |
| 54 | End Cap for Bore well 160mm Dia (PWD 2025-26 Page No 168 Unique code No M-1053) |
| 55 | 50mm Dia Pipe(Medium)as per IS 1239/Part I/2004 PWD SOR 2025-26 Page No 30 Unique code No WD-M0489 |
| 56 | 63mm dia PVC Male Threaded adop[ter (Twad Sor 25-26 Page No 11 Unique code No WD-M0114) Please Enable Macros to View BoQ information |