| 1 | Excavating in trenches in Soft Disintegrated Rocks, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out |
| 2 | Ditto as in Item Above but depth Exceeding 1.50 Mtr |
| 3 | Cement concrete of Type D2 1:4:8 (40mm Graded Aggregate) in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge |
| 4 | Reinforced cement concrete (design mix) of M-25 Grade (20 mm Graded Aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and as direected by Engineer in Charge |
| 5 | Reinforced cement concrete (design mix) of M-25 Grade (20 mm Graded Aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and as direected by Engineer in Charge |
| 6 | Reinforced cement concrete (design mix) of M-25 Grade (20 mm Graded Aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as direected by Engineer in Charge |
| 7 | Reinforced cement concrete (design mix) of M-25 Grade (20 mm Graded Aggregate) as in Chullah hoods; stairways (except spiral staircases) including steps (square or spandril), string pieces, carriages, etc., complete, any section straight or winding, but excluding landings complete all as specified and as directed by Engineer in Charge |
| 8 | Material and Labour to Fair Finished Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed by Engineer-in-Charge |
| 9 | Material and Labour to Fair Finished Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) → complete all as specified and as directed by Engineer-in-Charge |
| 10 | Material and Labour to Fair Finished Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed by Engineer-in-Charge |
| 11 | Material and Labour to Fair Finished Formwork to edges of concrete, flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed by Engineer-inCharge |
| 12 | Material and Labour to Fair Finished Formwork to Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing) complete all as specified and as directed by Engineer-in-Charge |
| 13 | S & F for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as directed. |
| 14 | Ditto As above but in Stirrups |
| 15 | Material and Labour for Hardcore of Broken Stones and Boulders, gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed By Engineer-in-Charge |
| 16 | Material and Labour for Cement concrete type C- 2, 1:3:6 (40mm graded aggregate), 100 mm Concrete complete all as specified and as directed By Engineer-in-Charge |
| 17 | Returning, filling in soft disintegrated rocks including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge |
| 18 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed |
| 19 | M&L for PCC 1:3:6 type C2 (using 40 size graded stone agg) as in bed concrete to drain for laid to slope as required complete all as specified and as directed by Engineer-in-Charge |
| 20 | M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in Coping including use of form work and finishing complete all as specified and as directed by Engineer-in-Charge |
| 21 | M&L PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in surface channels and drains all as specified and direcetd. |
| 22 | Extra for forming fair finished drain or channel 30 cms inner girth in cement using extra cement including forms, moulds mitred stopped ends etc all as specified and directed by Engineer-in-Charge |
| 23 | Demolition of Brickwork or Stone Boulder Masonary, Bulit in Cement Mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed by Engnr-in-Charge |
| 24 | M & L for brickwork with Fly ash Bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge |
| 25 | M&L 15 mm (5mm in CM 1:4 with WPC +10mm in CM 1:6 ) thick in two layers rendering in cm 1:4 on fair aces of bricks walls surface finished even and smooth without using extra cement including water proofing compound all as specified and directed. (Water proofing compound measured and paid seperately) |
| 26 | Material and Labour for Preparation of New Surfaces Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm over external Surface Putty one coat complete all as specified and as directed by Engineer-in-Charge |
| 27 | Supply only Integral waterproofing compound complete all as specified and directed. |
| 28 | M&L Granite of 20 mm thick (of any type and colour) (Z Black Granite, Sample Will be Selected by GE) work (table rubbed/grinding/ moulding and polished) in steps, over walls, jambs, pillars, window cills, cooking platforms, wash basin counter and like over and including 20 mm screed bed in CM 1:3 all as specified and directed. |
| 29 | Providing edge moulding to 18-20mm thick Granite Stone of any Type stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete. |
| 30 | Supply and Fix 16 to 18 mm thick, Dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size equal to or exceeding 0.25 Sqm but not exceeding 0.5 sqm area fixed with and including one number SS clamps (grade 202) of flat-30mm X 2mm, 150mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment complete all as specified and as directed by Engineer-in-Charge |
| 31 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed by Engineer In Charge. |
| 32 | Supply and Fix 12 mm thick Toughned Glass of any Type ( i.e. Plain or Frosted as required by the user including Embossing on the Glass of any design and Pattern as desired by the user ) as in Hinged Doors, Partitions, Railings, Automatic Doors and Similar work including cutting to Shape Drilling Holes required including necessary stainless steel fittings like Patch fittings Glass Clamps Etc suitable for Proper Jointing of 12 mm thick Toughened Glass with Railings (Accessories will be fancy Type and may be selcted by the user and rates quoted by the contractor will be inclusive of these items and only Toughened Glass will be measured for the Payment Purpose) and other connecting items necessary for proper functioning of door/Partitions/Railings complete all as specified and as directed by Engineer-in-Charge. |
| 33 | M & L for wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, modular plate, suitable GI box-1.5 mm and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required at site complete all as specified and directed by EIC. |
| 34 | S & F switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 35 | S & F LED Bollard light 10 watt, with aluminium die cast housing and polymer diffuser, deliver , Glare-free, impact-resistant, and corrosion-proof, IP65 rated Inverted Pyramid Tripod type LED Bollard with 360° uniform illumination, class-1, operating voltage 140V to 270V AC, 50 Hz, PF>0.9, surge protection 4kV, wired with inbuilt driver, 2 year replacement warranty complete all as specified and directed by EIC. |
| 36 | S&F new genration LED post top lanterns, IP-65 elegantly designed spun alumnium and high grade aluminium heat sink for efficient thermal management, sturdiness and excellent corrosion resistance. MS base provided to support the housing, environmental friendly long life high power LED light 25 watt complete all as directed by EIC . |
| 37 | S & F 6 W aluminum embedded staircase outdoor LED foot light waterproof lamp (white/warm white), ISI marked, outdoor type complete all as specified and directed by EIC. |
| 38 | S & F weather proof 3 core 4 sqmm flexible copper cable ISI marked alongwith 25 mm PVC conduits, junction box, tee, bends, elbow and connected accessories complete all as specified and directed by EIC. |
| 39 | S &F diffused light 12-18 Watt 4 rays up-down LED outdoor wall lights waterproof IP65 (warm white) with metallic body wall highlighter, fancy exterior wall mounted light complete all as specified and directed by EIC. |
| 40 | S&F in repair of SPN DB 6 way with 200 Amp rated bus bar, IP 43, ISI marked acrylic double door complete all as directed by EIC. Note: - Contractor must provides IP43 certificate. |
| 41 | S & F 6 A to 32 A rating, 240 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete connections with suitable thimble/lugs, testing and commissioning etc. as required at site complete all as specified and directed by EIC. |
| 42 | Single pole and neutral |
| 43 | Single pole Please Enable Macros to View BoQ information |