| 1 | CIVIL WORKSExcavation of foundation in hard soil including dressing and levelling the bed and depositing the soil within 50m. initial lead and 1.5m.initial lift including rough dressing and breaking clods to maximum 5cm. to 7cm. and laying in layers not exceeding 0.3m. in depth and as per the direction of the Department. |
| 2 | Supplying, filling in foundation and plinth with sand well watered and rammed in 22.5 cm. (9”) thick layers including watering and ramming with cost, conveyance, royalties and taxes of sand with labour and T&P required for the work etc. complete. |
| 3 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size clean hard black crusher broken granite stone metal of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15 cm. (6\\") thick to the required level ramming, watering, curing etc. complete including cost, conveyance, royalties and taxes of all materials with all labour and T&P required for the work etc. complete in all respect. |
| 4 | Fly ash brick masonry in cement mortar (1:6) in foundation & plinth using fly ash bricks of 23cm x 11cm x 8cm size having a crushing strength of not less than 75 kg./cm2 dimensional tolerance + 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least of six hours before use including cost, conveyance, royalties and taxes of all materials with all labour and T & P required for the work complete in all respect in all floors. |
| 5 | Fly ash brick masonry in cement mortar (1:4) in foundation & plinth using fly ash bricks of 23cm x 11cm x 8cm size having a crushing strength of not less than 75 kg./cm2 dimensional tolerance + 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least of six hours before use including cost, conveyance, royalties and taxes of all materials with all labour and T & P required for the work complete in all respect in all floors. |
| 6 | R.C.C. work of M25 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour and T & P required for the work etc. complete in all respect. |
| 7 | Base & Footing |
| 8 | Plinth Beam |
| 9 | Column/Beam |
| 10 | Lintel Band |
| 11 | Chajja |
| 12 | Roof Slab |
| 13 | Straightening bent up or coiled M.S. rod or HYSD steel (Fe-500), cutting, bending, cranking, hooking, welding or jointing (if required), the M.S. rods or HYSD steel and binding, tying the grills, hoisting, lowering and placing in proper position as required for R.C.C. works including cost, conveyance and taxes of M.S. rod or HYSD steel and binding wires of 18 to 20 gauge and labour with all T&P required for the work etc. complete in all floors. |
| 14 | Fly ash brick masonry in cement mortar (1:6) in super structure using fly ash bricks of 23cm x 11cm x 8cm size having a crushing strength of not less than 75 kg./cm2 dimensional tolerance + 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least of six hours before use including cost, conveyance, royalties and taxes of all materials with all labour and T & P required for the work complete in all respect in all floors. |
| 15 | 12 mm. (½”) thick cement plaster (1:4) over brick work including cement punning including watering and curing with cost, conveyance, royalties and taxes of all materials with all labour and T & P required for the work etc. complete in all respect. |
| 16 | 12 mm. (½”) thick cement plaster (1:6) finished smooth to outside smooth surface of brick walls after raking out the joint including watering and curing with cost, conveyance, royalties and taxes of all materials with all labour and T & P required for the work etc. complete in all respect. |
| 17 | Fly ash brick masonry in cement mortar (1:4) in super structure using fly ash bricks of 23cm x 11cm x 8cm size having a crushing strength of not less than 75 kg./cm2 dimensional tolerance + 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least of six hours before use including cost, conveyance, royalties and taxes of all materials with all labour and T & P required for the work complete in all respect in all floors. |
| 18 | Supplying, fitting and fixing vitrified tiles in floors of size 600mm x 600mm of approved make confirming to IS:13755 laid on 20mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour, T&P etc required for the work all complete as per direction of Engineer-in-charge. |
| 19 | Supplying, fitting and fixing glazed wall tiles for walls of approved dimension as directed by Engineer-in-charge in dados skirting and risers of steps on 12 mm. thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects. |
| 20 | 16 mm. (5/8”) thick cement plaster (1:6) finished smooth to inside rough surface of 9”/10” thick brick walls after raking out the joints including watering and curing with cost, conveyance, royalties and taxes of all materials with all labour, T&P required for the work etc. complete. |
| 21 | 2.5 cm (1\\") av. thick grading concrete (1:2:2) using 6 mm size black hard crusher broken granite chips over roof slab after chipping and chiseling laid to proper slope finished smooth to receive tarfelt treatment watering and curing including cost, conveyance, royalties and taxes of all materials with all labour and T&P etc. required for the work complete in all respect in all floors. |
| 22 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slury treatment with cost, conveyance, royalties and taxes of all materials with all labour and T & P required for the work etc. complete in all respect. |
| 23 | Supplying, fitting and fixing in position well dressed and well seasoned sal wood work framed and fixed (wrought and put up) small beams, purlines, burgahs, truss, rafter and post of door and window including cost of iron work cutting grooves or holes and mending size where necessary with cost and conveyance, royalties and taxes of all materials and labour with T&P required for the work etc. complete in all respect in all floors. |
| 24 | Providing and fixing shubhwood WOOD POLYMER COMPOSITE (Profile and colour as decided by client / Architect) deck flooring. This material is produced exclusively by Shubhwood, allowing Shubhwood to maintain the high quality of these products. The panels are of 145mm in width and 10 ft in length and of the thickness of 23mm. The profile should be installed on steel structure. The Wood Polymer Composite should confirm to the following standards:-1. Meets Class - A flame spread requirements. 2. Radiant Heat Test - Ignition Resistance of Exterior - Conclusion that Shubhwood met the conditions for allowable use as specified in section 1406 of the International Building Code.3. Wind Load Testing - Wood Polymer Composite has been tested to exceed the minimum wind load requirements per ASTM D3679 standard test method for resistance to negative wind load pressure.4. WPC Profile are resistance to moisture, rot and distortion. |
| 25 | Providing fitting, fixing of Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 3 mm thick Aluminium Composite Pannel sheet fixed on door frame by means of tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc. complete. |
| 26 | Supplying, fitting and fixing M.S. iron grill of approved design as directed by Engineer-in-charge and placing in proper position including cost, conveyance, taxes with all labour and T&P required for the work etc. complete in all respect. |
| 27 | Finishing wall surface with acrylic wall putty (water based) of approved make and finished smooth and even surface receive painting including cost of scaffolding staging charges with cost of all materials, taxes with labour etc. complete as per direction of Engineer-in-charge. |
| 28 | Providing two coats weather coat paints over a coat of primer of approved make and shade in all floors and height including cost, conveyance, taxes of all materials, cost of labour, T&P etc. as required for the work complete in all respect as per direction of Engineer-in-charge. |
| 29 | Wall Painting two coats with plastic emulsion paint of approved quality over a coat of wall primer to interior wall surface including cost of paint, primer, conveyance and taxes of all materials and labour with T&P required for the work etc. complete in all respect. |
| 30 | Painting two coats with any approved synthetic enamel paint of approved quality shade and make over a coat of primer to new wood work / iron work including cost of the primer and paint, sand papering polishing the surface with cost, conveyance and taxes of all materials and labour with T & P required for the work etc. complete in all respect. |
| 31 | P.C.C. work of M25 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour and T & P required for the work etc. complete in all respect. |
| 32 | P.H. WORKSSupplying all materials, labour, T&P and fitting,fixing of following Sanitary & P.H. Fixtures as per specification including cost of all materials,conveyance,contractor profit & labour cess etc all complete as per the direction of Engineer-in-charge. (Make-Parryware/ Hindware/ Plaza/ Zigna/ Jaquar) |
| 33 | Porcelain E.W.C. with P-trap |
| 34 | 10 litr pvc low level cistern with fittings |
| 35 | 15mmx600mm PVC connection pipe |
| 36 | 15mm dia C.P.angular stop cock with walll flange (Make-Jaquare,FLP-5053PM) |
| 37 | 2 way Bib cock with Wall flange(Make-jaquare, FLP-5041PM) |
| 38 | Hand Shower (Health Faucet)(ABS Body)with 8mm dia, 1 Meter Long Spirochrome flex tube & Wall Hock (Make-Jaquar) |
| 39 | Long Body Bib Cock with wall Flange ( Code-FLP-5037PM) Make-Jaquar |
| 40 | Shower Arm 400x25x25mm Square Shape for Wall Mounted Shower with Flange ( Make-Jaquare,SHA-455L400) |
| 41 | 15mm dia C.P concealed stop cock, ALI-85083K,Exposed Part Kit of Concealed StopCock & Flush Cock with Fitting Sleeve,Operating Lever & Adjustable Wall,Flange with Seal (compatible with ALD-083, ALD-089 or ALD-081) |
| 42 | Glass Shelf 600mm Long,Code-CPA-1171(Make-Jaquar |
| 43 | Stainless Steel can-Chr-1111Sm Towel Rail 600mm,Standard size,(Make-Jaquar) |
| 44 | Porcelain Squatting Urinal (600x355mm)(Sl No.260) |
| 45 | Supplying, fitting and fixing of 40mm PVC Fulsh Bend |
| 46 | W.H.B-KUS-WHT-35801PM,Wall Hung Basin With Fixing Accessories,Size: 600x435x185 mm(Make-Jaquar) |
| 47 | Pillar cock -Chrome, Code-FLP-CHR-5011PM(Make-Jaquar) |
| 48 | C.P. waste (32mm - Small) for Basin |
| 49 | 32mmx 1150mm long PVC waste pipe for Basin |
| 50 | Towel Ring Round ( Code-ACN-1121BN) Make-Jaquar |
| 51 | Providing and fixing to wall or ceiling and floor pvc pipes class conforming to ASTM-D-1785/ 89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor including cost of all materials,conveyance to worksite,contractor profit & labour cess etc all complete and direction of Engineer-in-charge. |
| 52 | 15mm PVC sch-80 pipes |
| 53 | 25mm PVC sch-80 pipes |
| 54 | Supplying & fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge. |
| 55 | 2000 litre capacity 3 - Layer White Rotational Moulded Cylinderical Vertical water storage tanks (ISI marked) |
| 56 | Construction of Sintex Base & Staging |
| 57 | Supplying all materials, labour, T&P for Cutting grooves in Pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification including cost of materials,royalty, conveyance, contractor profit & labour cess etc all complete as per direction of Engineer-in-charge. |
| 58 | Cutting hole in R.C.C floors and roofs upto 19 cm thick for passing G.I / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof |
| 59 | Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per specification.250mm thick wall |
| 60 | Supplying & fixing of Brass or Gun Metal Full Way Valve conforming to IS:781-1995 of the following nominal sizes with wheel as per specification complete as per direction of Engineer-in-charge. |
| 61 | 15mm diaBrass or Gun Metal Full Way Valve |
| 62 | 25mm diaBrass or Gun Metal Full Way Valve |
| 63 | Supplying all material, labour,T&P and laying in trenches unplasticated PVC pipes conforming to IS:4985-2000 and specials of the following outside diameter for all classes including jointing with supply of approved solvent cement bu non-heat application method including testing, contractor profit & labour cess etc as per specification complete (Earth work in trenches to be measured and paid for separately) as per direction of Engineer-In-charge(Derived rate base on UPVC pipe P-2.3(AR PH-2013) |
| 64 | 110mm dia rigid UPVC pipe Class-II (0.40 mpa) |
| 65 | 160mm dia rigid UPVC pipe Class-II (0.40 mpa) |
| 66 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes110mm OD P.V.C. SWR S/S Pipe (ISI type-B) |
| 67 | Supplying all materials, labour, T&P and making connection of drain or sewer line with existing Manhole including breaking into and making good the walls, floor with cement concrete (1:2:4), cement plastered on both sides with cement mortar (1:3) finished with a floating coat of neat cement and making necessary channels with cement concrete (1:2:4) for the drain all complete as per specification. |
| 68 | Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion |
| 69 | 110mm dia P.V.C. SWR S/J with door |
| 70 | 1610mm dia P.V.C. SWR S/J with door |
| 71 | 110mm dia P.V.C. SWR door bend 87.5' |
| 72 | 160mm dia P.V.C. SWR door bend 87.5' |
| 73 | 110mm dia P.V.C. SWR plain bend 87.5' |
| 74 | 160mm dia P.V.C. SWR plain bend 87.5' |
| 75 | 110mm dia P.V.C. SWR pipe clip |
| 76 | 110mm dia P.V.C. SWR vent cowl |
| 77 | 110mm dia P.V.C. SWR coupler |
| 78 | 160mm dia P.V.C. SWR coupler |
| 79 | 110 x 110 x 110mm dia PVC SWR Tee |
| 80 | 160 x 160 x 160mm dia PVC SWR Tee |
| 81 | Supplying all materials, labour, T&P and making connection of drain or sewer line with existing Manhole including breaking into and making good the walls, floor with cement concrete (1:2:4), cement plastered on both sides with cement mortar (1:3) finished with a floating coat of neat cement and making necessary channels with cement concrete (1:2:4) for the drain all complete as per specification. |
| 82 | ELECTRICAL WORKSWIRINGWiring for light point/ fan point/ exhaust fan/wall fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box including supplying the same and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 83 | Group A |
| 84 | Group B |
| 85 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 86 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire for 5/6 A Sockets. |
| 87 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire for 15A PP & Switch Boards |
| 88 | 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire for Meter Board to 16A socket/switch |
| 89 | 3c x 6 SQMM Service Wire |
| 90 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 91 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 92 | Supplying and fixing following way, horizontal type Single pole and neutral, sheet steel, MCB distribution board, 230 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 93 | 12 Way SPN DB |
| 94 | Supplying and fixing 5 amps to 63 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 95 | Single pole (10A SP MCB) |
| 96 | Double Pole (32 A DP MCB) Incomer |
| 97 | Supplying and laying 6 SWG G.I. wires ISI marked at 0.5 meter below grond level for conductor earth electrode including soldering etc. as required |
| 98 | FITTING & FIXINGSupplying & Installation of 250 mm exhaust fan as per EIC of approved make including with all,., materials & labour. .(Make: Crompton or Equivalent)) |
| 99 | LED Down lighter (COB Type) (System lumen efficacy ≥ 105 < 120 lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/square/ Rectangular) COB Type of following body material and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI>80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K/5700°K/6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 Im/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 100 | 8 Watt |
| 101 | 18-22 Watt |
| 102 | 9 Watt Mirror light |
| 103 | 36 Watt Please Enable Macros to View BoQ information |