| 1 | DSR ITEM No.2.4Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required. |
| 2 | 4 way (4 + 12), Double door |
| 3 | DSR Item No. 2.10Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 4 | Single pole |
| 5 | Triple pole and neutral |
| 6 | DSR Item No.5.2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 7 | DSR item no.5.12Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 8 | DSR item no.2.2Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 9 | 100 A,30KA,FPMCCB |
| 10 | DSR Item No 15.16Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. Direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. Complete as required. |
| 11 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 12 | Supply and Laying of following XLPE insulated and PVC sheathed, armored, aluminum conductor cable of 1.1KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in DWC/GI/Hume/ pipe as required at site. The job include the cost of making connections with suitable size of Al. Lugs/ thimbles, testing, commissioning etc. as required to the entire satisfaction of Engineer In Charge. The cable should of be Polycab / Havells / Finolex / RR Kabel/ KEI/ RPG/ Universal/ Grandlay make only. |
| 13 | Size 10 Sq.mm 4 core PVC Al. Arm. Cond. Cable |
| 14 | Size 25 Sq.mm 3.5 core PVC Al. Arm. Cond. Cable |
| 15 | DSR item no.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size andCCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). |
| 16 | 250 watt |
| 17 | Supply and erection of sheet metal cubical pedestal of suitable dimensions made from 50 mm X 50 mm X 6 mm thick M.S angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides and front side hinged complete with locking arrangement with 4 Nos. switchgear supporting members each of M.S. flat 50 mm X 6 mm thick of suitable length duly welded. The cubical pedestal shall have 4 Nos. legs of 50 mm X 50 mm X 6 mm each 60 cm long M.S. angle iron each long including painting, bonding to the existing earth etc. the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15cm high form ground level and 45 mm thick. The cubical pedestal shall be 15 cm from the top of cement concrete platform. |
| 18 | Cubical size 900 mm x 600 mm x 350 mm |
| 19 | Cutting, dismantling of existing concrete floor of size 1.5’ wide 6’ deep. The malba should be shifted to appropriate place. The job includes the cost of providing concrete work with cement sand, bajri, mixture ratio 1:3:6 of size 1.5” wide 6” deep and finishing the same in original shape as required at site to complete the job to the entire satisfaction of EIC. Please Enable Macros to View BoQ information |