| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/dense soil as directed by site in-charge. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. Hard/dense soil , as directed by site in-charge. |
| 3 | M&L Sand filling under floors or in foundations including watering and consolidation, as directed by site in-charge. |
| 4 | Demolition of Cement Concrete unreinforced of any description and in any position, as directed by site in-charge. |
| 5 | M&L of Providing, Cement concrete in foundations, filling and mass concrete Type C2 , 1:3:6 (40 mm graded aggregate) in foundations,filling and mass concrete for pole foundation as directed by site-in-charge |
| 6 | M&L of Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges .Type -B0,1:2:4 (12.5mm graded aggregate), as directed by site in-charge. |
| 7 | Supply and applying of first coat of white washing over undecorated surface for the complete copping of the pole as directed by site-in-charge. |
| 8 | Supply and applying of Subsequent coat of white washing for the complete copping of the pole as directed by site-in-charge. |
| 9 | Supply and painting of Priming with Aluminium Red oxide surfaces of any description, over 10cm in width or girth, not otherwise described as directed by site-in-charge. |
| 10 | Supply and painting of Aluminium paint (each coat) surfaces of any description, over 10cm in width or girth, not otherwise described as directed by site-in-charge. |
| 11 | Supplying and laying un-reinforced precast concrete cable cover, but,Type 2, flat, size 300mm x 180mm x 40mm , as directed by site in-charge. |
| 12 | Materials & Labours for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core cross-sectional area 50 sq. mm cable laying through pipe & trench termination with proper lugs and glands as to be done as directed by site in charge. Make: Havells/V-Guard/Gloster/KEI/L&T |
| 13 | Materials & Labours for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 4 core cross-sectional area 16 sq.mm cable laying through pipe & trench terminationat with proper lugs and glands of each street light pole to be done, as directed by site in charge. Make of wires : Havells/V-guard/Gloster/KEI/ L&T |
| 14 | S&F of Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required 2x1.5 sq. mm + 1x1.5 sq. mm earth wire in Steel conduit with accessories. Make of wires: Havells/v-guard/ Gloster/L&T/KEI, as directed by site incharge. |
| 15 | Fixing only, LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, as directed by site incharge. |
| 16 | Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, as directed by site incharge. |
| 17 | M & L of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long), as directed by site-in-charge. |
| 18 | Supply & Laying of steel water tubing medium grade ISI marked, galvanized with all fittings laid in trenches bore of tube 100mm for cable protection as directed by site-in-charge. |
| 19 | Supply & Laying of steel water tubing medium grade ISI marked, galvanized with all fittings bore of tube 32 mm for street light fitting also proper for making forged bends on piping as required shaped, as directed by site-in-charge. |
| 20 | Supply & Laying of steel tube medium grade ISI marked, galvanized with all fittings laid in trenches for street light each fittings, bore of tube 40 mm, also proper for making forged bends on piping as required shaped, as directed by site-in-charge. |
| 21 | Supply & fixing of Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel'), as directed by site-in-charge. |
| 22 | Supply & Fixing of cast irin moulded marked as \\"LT CABLE\\"route indicator with M.S.iron \\"L\\" angle of size 25mm*25mm*5mm and support stand Height is 60 CM. |
| 23 | Supply and fixing of weather proof FRP Junction box minimum size of 300 X 200 MM X 100 mm with mounted in DIN rail, bolt & nut type 3 phase 63 Amps terminals connector with neutral, for street light pole to be fixed at a height of 1.2 m with proper termination for connection of 16 Sq mm street light cable as directed by site in charge. Please Enable Macros to View BoQ information |