| 1 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed. |
| 2 | M&L for Brick work with sub class 'B' old size bricks, straight or curved on plan exc 6 m mean radius, using old size brick, built in cement mortar 1:4 complete all as specified and directed. |
| 3 | M&L for Brick work with sub class 'B' old size bricks, straight or curved on plan exc 6 m mean radius, using old size brick, built in cement mortar 1:6 complete all as specified and directed. |
| 4 | M&L for half brick work with sub class ‘B’ bricks, using old size bricks, straight or curved on plan to any radius, built in CM 1:4, complete all as specified and directed. |
| 5 | Taking down cement plaster of any description on bricks, PCC block or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed. |
| 6 | M&L for rendering 10mm thick in cement mortor 1:6 on brick work or concrete surfaces or other than fair faces of brick work, finished even and smooth without using extra cement, complete all as specified and directed. |
| 7 | M&L for 15mm thick rendering on fair faces of brick work / concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement and mixed with water proofing compound, complete all as specified and directed.Note :- WPC shall be measured and paid separately under respective item of this BOQ. |
| 8 | Supply only integeral water proofing compound, complete all as specified and directed. |
| 9 | M&L for two coats of cement based paint over newly plastered surface of wall including one coat of chalk whiteningprimer including preparing the surface, complete all as specified and directed. |
| 10 | M&L for preparation of new plastered surfaces of wall and applying 1 to 1.2mm thick Altek/Birla white putty to obtain smooth and even finish with using sand paper and applying two coats of distemper oil emulsion over one coat of alkali resistant cement based priming paint, complete all as specified and directed. |
| 11 | M&L for providing 50mm thick cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) as in plinth protection, finished even and smooth with using extra cement, complete all as specified and directed. |
| 12 | M&L for two coats of synthetic enamel paint on steel surface over one coat of priming with red oxide zinc chrome primer of any description, over 10cm in width or girth not otherwise described including preparation of surface, complete all as specified and directed. |
| 13 | M&L for preparation of old steel or iron surfaces of any description, exceeding 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc primer, complete all as specified and directed. |
| 14 | M&L for hardcore of broken stone or boulders of gauge not exc 63mm, deposited, spread and leveled in layers not exc. 15cm thick, watered and well rammed to a true surface, complete all as specified and directed. |
| 15 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in floors, complete all as specified and directed. |
| 16 | M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base of floors, complete all as specified and directed. |
| 17 | M&L for machine pressed cement concrete interlocking paver block, glossy finish, any shape, ISI marked, any shape and size, conforming to IS:15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment, complete all as specified and directed. |
| 18 | M&L for sand cushioning bed under floor or paver blocks including spreading, levelling, watering if required, complete all as specified and directed. |
| 19 | Dismantling of asbestos cement (corrugated, semicorrugated etc.) sheets as in roof coverings, complete all as specified and directed. |
| 20 | S&F prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with galvanised 8mm dia 'J' hook or self tapping screws, complete all as specified and directed. |
| 21 | S&F prepainted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa (AZ-150) as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 22 | M&L for rolled mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc & similar work, conforming to Fe-290 Gde E-165, complete all as specified and directed. |
| 23 | Dismantling of floor hearth or wall tiling incl cement mortar bedding (but not backing) removing, rubbish off the premises, complete all as specified and directed. |
| 24 | M&L for glazed ceramic coloured tiles of size 450x350x7mm thick and above nearest size (as approved) as on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 10mm thick plaster in CM 1:3, complete all as specified and directed. |
| 25 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 26 | M&L for non skid coloured ceramic tiles 7 to 8mm thick (square/ rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in skirtings, dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, fixed over and including 15mm thick plaster in CM 1:4, complete all as specified and directed. |
| 27 | M&L for galvanised steel wire cloth size 0.56mm nominal dia of wire and average width of aperture 1.18mm, fixed with tinned tacks or galvanised wire staples, complete all as specified and directed. |
| 28 | S&F 3mm thick glass sheet, ordinary quality and glazing with oil putty in squares not exc 0.50 Sqm in each pane, complete all as specified and directed. |
| 29 | S&F 3mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 Sqm in each pane, complete all as specified and directed. |
| 30 | S&F bib tap, standard of PTMT of any colour, screwed for 15mm bore iron pipe (min. weight 15mm- 90gms), complete all as specified and directed. |
| 31 | S&F 10 ltrs capacity PVC valveless syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, complete all as specified and directed. |
| 32 | S&F in replacement of ball brass valve of 20mm dia, high pressure with polythene float and fly nut, complete all as specified and directed. |
| 33 | S&F 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) of tripple layered, white in colour (inside & outside), hoisted and fixed in position including inlet, outlet and overflow connection nipple of suitable size, complete all as specified and directed. |
| 34 | S&F 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) of tripple layered, white in colour (inside & outside), hoisted and fixed in position including inlet, outlet and overflow connection nipple of suitable size including dismantling and removing of existing old tank of any capacity, complete all as specified and directed. |
| 35 | Taking up or down steel tubing and connection including cleaning for re-fixing or removal to store of size of pipe 15mm bore, complete all as specified and directed. |
| 36 | Taking up or down steel tubing and connection including cleaning for re-fixing or removal to store of size of pipe 20mm bore, complete all as specified and directed. |
| 37 | M&L for 15mm bore steel water tubing medium grade galvanised with all fitting and fixtures, complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 38 | M&L for 20mm bore steel water tubing medium grade galvanised with all fitting and fixtures, complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 39 | S&F 300mm long mild steel sliding door bolts, plate type, stove enamelled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple platem, complete all as specified and directed. |
| 40 | S&F MS helical door spring of 300mm size including roller and roller plate, fixed to wooden or steel frames with welding/ fitted with screws etc, complete all as specified and directed. |
| 41 | Excavation in trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth in foundation or for shafts, wells, cesspits, manhole, pier holes etc, not exc 10 Sqm on plan and not exc 1.5 mtr in depth and getting out in any type of soil, complete all as specified and directed. |
| 42 | Returning, filling in, spreading, leveling, watering and well ramming in layers not exc 25cm in any type of soil, complete all as specified and directed. |
| 43 | Removing excavated material (soil) to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr from the starting point, complete all as specified and directed. |
| 44 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling in and mass concrete, complete all as specified and directed. |
| 45 | M&L for RCC M-25 (Design Mix) (using 20mm graded crushed stone aggregates) as in foundation including rafts, footing, foudations beams, plinth beams, bases for coloumns etc. basement slabs under-reamed piles and mass concrete, complete all as specified and directed. |
| 46 | M&L for RCC M-25 (Design Mix) (using 20mm graded crushed stone aggregates) as in beams, cantilever, bressummers, linle over 1.5 mtr span etc, complete all as specified and directed. |
| 47 | M&L for RCC M-25 (Design Mix) (using 20mm graded crushed stone aggregates) as in columns, piers, posts and struts etc, complete all as specified and directed. |
| 48 | Use and waste of formwork of flat rough finished concrete surfaces of foundation, footing bases of coulmn, raft & raft beam and similar work, complete all as specified and directed. |
| 49 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams etc, flat rough finished concrete surfaces, complete all as specified and directed. |
| 50 | Use and waste of formwork to rough finished concrete sides of pillars, columns, square or rectangular, complete all as specified and directed. |
| 51 | M&L for mild steel TMT bars 6 to 8mm dia as in stirups, cut to length bent to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia, complete all as specified and directed. |
| 52 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90 mm dia, complete all as specified and directed. |
| 53 | Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed. |
| 54 | M&L for 100mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in sub base, complete all as specified and directed. |
| 55 | Demolition of cement concrete (un-reinforced) as in roofs of old brick tiles of existing water proofing treatment or any type treatment of any thickness, complete all as specified and directed. |
| 56 | M&L for roughing surface of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc for local depressions RCC surface and brushing neat cement slurry with 3.0 Kg of cement per Sqm, complete all as specified and directed. |
| 57 | M&L for apply bituminous primer confiriming to IS -3384 @ 0.40 Kg/ Sqm on prepared surface on sunny day. After the primed surface has dried and apply a coat of hot blown 85/25 penetration grade blown bitumen, confirming to IS -702 @ 1.20 Kg/Sqm on the surfaces. Provide APP (Atactiic Polypropylene) modified polymeric five layered membrane with central core of 100 micron high molecular high density firm. Minimum weight of membrance will be 3 kg/Sqm. APP membrance will be laid across the slope from lowest line sloping roof towards ridge with minimum end lap of 150mm & side lap of 75mm bonded with hot blown bitumen. Over the APP membrance apply semi hot blown 85/25 penetration grade bitumen @ 1.20 Kg/Sqm and blinded with fine sand in dry condition @ 0.50 Kg/Sqm dusted over the bitumen coat with aluminium paint, complete all as specified and directed.Note :- The laying of the membrane shall be got done by authorized applicator of the membrane manufacturer. |
| 58 | M&L for 15mm thick cement plaster in CM 1:3 on roof surface, finished even and smooth using extra cement including mixing of water proofing compound for accessable roof/ Non Assessable roof, complete all as specified and directed.Note :- WPC shall be measured and paid separately under respective item of this BOQ. |
| 59 | S&F in replacement of stop vlave, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe of 15mm bore, complete all as specified and directed. |
| 60 | M&L for factory made glossy finish coloured chequred cement concrete tile size 30cm x 30cm x 25cm thick each, machine pressed, set & jointed in neat cement slurry as in floors, joint fill up with white grey cement & pigments, fixed over and including 15mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 61 | M&L for preparation of new plaster surfaces of wall and smoothening the surface with sand paper/ machanised sanding etc. and applying two coats of oil bond distemper over one coat of primer and applying 1mm thick wall care putty, complete all as specified and directed. |
| 62 | Dismantling of timber scanting of any size and shape, in framed work, 40 Sqcm and over in section, in any position, complete all as specified and directed. |
| 63 | M&L for rolled mild steel tubular trusses, posts, purlines including special shaped, notched forming holes, without any attachment including drilling, fitting, riveting and or welding or connecting with bolts and nuts (including rivet or nut and bolts) providing and fitting angle cleats, gussete plates etc, also for wedging, plumbing and fixing complete washers etc, complete using ERW or induction butt welded tubes conforming to IS 1161 - 1979 grade St-240, complete all as specified and directed. |
| 64 | Demolition of cement concrete (un-reinforced) in any description and in any position not other wise provided for and removing the debris to a distance not exc 500 mtr form site, complete all as specified and directed. |
| 65 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed. |
| 66 | M&L for colour chequered cement concrete tiles of size 30cm x 30cm x 25cm thick each, set, jointed and pointed in neat cement slurry as in floors, complete all as specified and directed. S&F in repair rigid non - metalic PVC casing caping of 25/12mm inclusive of all elbow, tees,etc complete all as per the direction of Engr-in-Charge. Please Enable Macros to View BoQ information |