| 1 | Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area. |
| 2 | 33 KV VCB 800 Amp. 750 MVA |
| 3 | 33 KV Control Pannel single circuit Transformer |
| 4 | 33KV Current Transformer 200/100/1 |
| 5 | 11 KV Incoming VCB 600/300/5A, 350 MVA |
| 6 | 11 KV Out going VCB 200/100/5A, 350 MVA |
| 7 | 11 KV 3x300mm2 XLPE Cable |
| 8 | 11 KV 3x300mm2 Outdoor Termination Kit |
| 9 | 11 KV 3x300mm2 Indoor Termination Kit |
| 10 | 11 KV 3x185mm2 XLPE Cable |
| 11 | 11 KV 3x185mm2 Outdoor Termination Kit |
| 12 | 11 KV 3x185mm2 Indoor Termination Kit |
| 13 | 11 KV 3x185mm2 Straight though |
| 14 | 33 KV Lightening Arrester |
| 15 | 33 KV Bus Isolator |
| 16 | 33 KV Line Isolator |
| 17 | ACSR Panther Conductor for Bus Bar |
| 18 | ST pole 11 mtr long |
| 19 | Supply of Battery charger 24 Volt |
| 20 | Supply of Battery set 24 Volt |
| 21 | MS Round of 32 mm dia for laying of main earthmat in switch yard & for panel earthing bridge [email protected] Kg./M |
| 22 | MS Round of 32mm dia for making MS earth electrode 32x3000mm. [email protected] Kg./M |
| 23 | Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all the material except MS Round Bar 32 MM) |
| 24 | Cutting ,fabrication and driving of earth electrode of size 32x3000 mm |
| 25 | Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor ) |
| 26 | Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms. |
| 27 | Outdoor switch yard & aproch road Lighting (4 NO. LED Street Lights and required wires clamps & other materlas provided by contractor expact ST Pole ) |
| 28 | Hoisting of 33 KV 3x300 Sqmm XLPE cable on Cable stand/ structure including its jumpering complete with holding clamps, PG clamps, Nut & bolts (All material will be provided by contractor) |
| 29 | High Pressure Testing of 33/11 KV cable. Testing equipment will be arranged by contractor. |
| 30 | Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel). |
| 31 | Painting of all structures equipment . |
| 32 | Construction of Power T/F plinth suitable for 33/11KV 5 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6 M as 12 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8 using M.S bar of 12 mm dia for reinforcement the work includes laying of 2 nos rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department) |
| 33 | Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4Nos foundation volts for erection of 33KV VCB. |
| 34 | Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt) |
| 35 | Lightning Arrestor/ CT structure/ PT structure : - Fabrication of lightning arrestor/CT structure/ PT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect. |
| 36 | Erection of structures, grouting, plinthing and painting of ALL structures equipment. |
| 37 | Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment . |
| 38 | 33 KV VCB |
| 39 | CT 200/100/1-A |
| 40 | 33 KV lightning Arrestors |
| 41 | Bus/Line Isolator |
| 42 | Fabrication & Erection of Neutral Stand structure with foundation |
| 43 | Safe dragging of 33KV 5 MVA T/F and its accessories like radiator, conservator tank, exposure event from unloading place upto T/F plinth its placement on plinth and with proper alignment approximate 25 Mtr distance with the help of crane sleepers and man power etc. |
| 44 | Erection and commissioning of 5 MVA T/F mounting of radiator conservator tank exposure vent etc. Filling of T/F oil in radiator conservator tank with complete work as per RESPO Norms. |
| 45 | Jumpering complete T/F bay with ACSR panther Cond. and required clamp with nut &Bolts from 33KV existing bus bar & 33KV cable to T/F (with copper L piece if required) complete work. (1 no. T/F bay) |
| 46 | Supply and fixing of PG clamp Panther to Panther |
| 47 | Laying of double circuit 11KV 3x300 sq mm XLPE cable in cable trench with proper ferrurling. Cable trench should filled by fine sand. |
| 48 | Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand/panel with proper taping with the help of empire tape. PVC tape and connectors. |
| 49 | Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench. |
| 50 | Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms |
| 51 | Supply & Laying of copper control cable of following sizes its proper dressing, ferruling and connection with the system. |
| 52 | 2x2.5 sq mm |
| 53 | 4x2.5 sq mm |
| 54 | Boring type Earthing of Substation equipment and 5 MVA T/F body and neutral (delta type) by way of boring and lowering of G.I pipe 1.5\\" dia up to water level and minimum 20 M deep from the ground level connection in between GI pipe and T/F with GI strip of size 50x6 mm. |
| 55 | Supply of Rabber mat 2x1.5 Mtr. |
| 56 | Supply and installation of fire extinguisher Co2 type 4.5 Kg at suitable place as per RESPO Norms |
| 57 | Supply and installation of bucket with bucket stand as per norms (3nos bucket for sand & 3 nos bucket for water in one set.) |
| 58 | Complete work of fixing of inertlocking tils in swithchyard area. (All the materials shall be provided by contracter) |
| 59 | Provideing gravels (20 mm stone ballast) in swithcyard upto 15 cm hight form the graund level. |
| 60 | Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement, erection, and grouting commissioning and testing of the same as per RESPO Norms |
| 61 | Feeder control panel/T/F control pannel |
| 62 | 11 KV Incoming VCB 600/300/5A, 350 MVA |
| 63 | 11 KV Out going VCB 200/100/5A, 350 MVA |
| 64 | Erection of 24 V batteries set with charger including stand (stand shall be provided by contractor) & initial charging complete set. |
| 65 | Digging of pit in Kachcha/Pakka land in depth upto 1/6 length of pole, Dragging of STP from nearby place/dump, Erection of single pole along with stone pad in bottom with proper alignment on 11/9 Mtr long ST pole and refilling with ramming of earth |
| 66 | Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement, sand and brick ballast as per RESPO norms. |
| 67 | Construction of pole plinth 300 mm x 450 mm above ground level in 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms. |
| 68 | Painting of new erected ST pole with two coat of Red oxide paint, PO red paint at top of pole 2 mtr and balance by two coats of best quality aluminium paint ISI of Berger/Nerolac/Asian paints as per norms. |
| 69 | Eerection of single pole 09 mtr. Long with fixing of required clamps for street light in switchyard as per RESPO norms. . (All material will be provided by contractor except ST pole). |
| 70 | Fabrication & erection of 11 KV cable Exposure type double pole with the provission of bus bar with fixing of necessary clamps and other accessories like danger board, number plate, barbed wire, 9 no. pin insulators with pins, 2 No. MS-CHANNEL & 2no. MS angle for supporting the hoisting on Pole.Its jumpering by single core PVC aluminium cable withproper size of lug (All material Provided by Contractor except ST pole, steel part, Pin & Pininsulator and PVC aluminium cable ).as per RESPO norms. |
| 71 | Earthing of poles with MS- Earthing rod 20x2500 mm, earth wire with nut and bolts as per norms (All material will be provided by contractor except MS-Earthing rods). |
| 72 | Laying of 11 KV XLPE cable 3x185 sq mm S/C by digging of trench 800 mm deep & 450 mm wide its boxing with bricks & sand, laying of cable filling of sand up to top cover of the trench properly levelling & ramming & covering with stone slab after laying of cable. (All material shall be provided by contractor except 11 KV cable) |
| 73 | Hoisting of 11KV, 3x185 sq mm XLPE on D/P with G.I. pipe 4\\" dia , clamp nut and bolt and other required material (All materials shall be provided by contractor except 11 KV cable) |
| 74 | Digging of pit of size 3x2x1 mtr. for making straight through joint 11 KV work involved filling of soil levelling and ramming of the same. |
| 75 | Safe Dragging, loading, carriage and unloading of balanced materials with proper stacking from site to JE dump store/Lesa store after completion of work. |
| 76 | Provided NOC from Electrical Safety department for Energization of 5 MVA Transformer. (The amount willl be reimbursed as per actual expenditure/ receipt issued by concerned department upto maximim limit of Rs. 50000.00) |
| 77 | Other Misc. Work if required. |
| 78 | All taxess as applicable shall be paid time to time extra Please Enable Macros to View BoQ information |