| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. DSR 15.56 |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : DSR 15.12 |
| 3 | Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. DSR 15.4 |
| 4 | 12mm thick cement plaster Mixe 1:4 cement Coarse sand mix mortar in plinth ( inner side) DSR 13.4.1 |
| 5 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate. DSR 11.3.1 (Work on roof) |
| 6 | Supply of Murga Jali. Cha-1 S.No. 15 SOR 2022-23 |
| 7 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. DSR 10.25.2 |
| 8 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately)35 mm thick shutters DSR 9.5.1.1 |
| 9 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately)30 mm thick shutters DSR 9.5.1.2 |
| 10 | E/W in excavation by mechanical means (Hydraulic Excavatory)/manual means in foundation trenches or drain (Not exceeding 1.5m in width or 10 sqm on plan). I/c dressing of sides and ramming of bottoms, for all lift, i/c getting out the excavated soil and disposal of surpluse excavated soil as directed, within a lead of 50 m. DSR 2.8 |
| 11 | Providing and laying in cement concrete 1:4:8 (1 cement: 4 coarse (Zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 4.1.8 |
| 12 | Brick work with common bruint clay F.P.S. (Non Modular) Brick of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 Cement ; 6 coarse sand) DAR NO. 6.1.2) |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 5.2.2 |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 |
| 15 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete Name of Work:- PROPOSED ESTIMATE FOR CONSTRUCTION OF B.R.C. BUILDING AT BARABANKI ABSTRACT OF COST (Based on CPWD D.S.R.-2023 & Market Rates) (plinth area of the building at ground floor only shall be measured as per I.S.6313 (Partll 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer'sstandard dilution) DSR 2.35.3.1 |
| 16 | Brick work with common bruint clay F.P.S. (Non Modular) Brick of class designation 7.5 in supper structure above plinth up to floor v level in all shapes and sizes cement mortar 1:6 (1 Cement ; 6 coarse sand) DAR NO. 6.4.2 |
| 17 | Providing and laying in position specified grade of reainforced cement concrete excluding the cost of centering and shuttering and finishing rainforment in 1:2:4 (1 cement:2 coarse Sand Zone-III) derived from natural sources :4 graded stone aggregate 20 mm nominal size derived from naturela sources in Plinth Beam. DSR 5.1.3 |
| 18 | Centering and shuttering i/c strutting, propping etc and removal of form for Lintels, beams, plinth beams, girders, bressumers and centilevers.. DSR No. 5.9.5 |
| 19 | Reinforced cement concrete work in arches, archribs, domes, valuts, shells, folded plate and roofs having slope more that 150 up to floor 5 livel, excluding the cost of centering, shuttering, finishing and reinforcement with 1;1.5:3 (1 Cement,: 1.5 coarse sand (Zone-III) derived from natural sources: 3 graded stone agrgregate 20 mm nomial size derived from natural soruces. DAR 5.5 |
| 20 | Centering and shuttering i/c strutting, propping etc and removal of form for Slab.. DSR No. 5.9.3 |
| 21 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. DSR 10.25.2 |
| 22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding DSR 9.48.1 |
| 23 | Steel reinforcement for RCC work i/c straightening, cutting, bending, placing in postion and binding all complete upto plinth level and above plinth levet Thermo-Mechanically treated bars of grade Fe-5000D or more. DSR No. 5.22.6 |
| 24 | 12 mm thick Cement plaster in 1:3 cement coarse sand finished with a floating coat of neat cement. DSR 13.9.1 |
| 25 | 12mm thick cement plaster Mixe 1:6 cement fine sand mix mortar in plinth ( inner side) DSR 13.1.2 |
| 26 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate. DSR 11.3.1 |
| 27 | Supply & glass strip in joints for terrazo/cement concrete floors 40 mm wide and 4 mm thick. DSR 11.13.1 |
| 28 | Excavating, supplying, stacking and filling of local earth (i/c royalty) by mechanical transport upto a lead of 5km also i/c remming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinths, sides of foundation etc. complete for all lift. DAR No. 2.25(a) |
| 29 | Providing & applying white cement based putty of aveage thickness 1mm of approved brand and manufacturer ove the plastered wall surface to prepare the surface even and smooth complete SI No DSR 13.80 |
| 30 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. DSR 13.48A.1 |
| 31 | Distempering with 1st quality acrylic distemper (Ready Mixed) VOC content less tha 50 gm/ltr. Of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (Two or more coats) over and including water thinnable priming coat with cemnt primer having VOC content less than 500 gram/Ltr. DSR 13.41.1 |
| 32 | Painting with synthetic Enamel paint of approved brand and manufacture of required colour to give and even shade, Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 |
| 33 | Provision for Tiolet fittings complet work (Only for Estimation Purpose) |
| 34 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 35 | Point wiring in PVC conduit, with piano type switch :-Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR 1.10.3 (Ele 2022) |
| 36 | Power plug wiring in PVC conduit (2 x 4 Sq.Mm.):Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. DSR 1.12 |
| 37 | Circuit/ Sub main wiring in PVC conduit:-Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 1.5 sq. mm+ 1 X 1.5 sq. mm earth wire. DSR 1.14.1 |
| 38 | Circuit/ Sub main wiring in PVC conduit:-Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 2.5 sq. mm+ 1 X 2.5 sq. mm earth wire. DSR 1.14.2 |
| 39 | S/F power plug point piano type accessories:-Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. DSR 1.30 |
| 40 | S/F modular type electronic fan regulator:-Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. As required. DSR 1.25 |
| 41 | S/F modular type blanking plate :-Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. DSR 1.26 |
| 42 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: DSR 1.21 20 mm DSR 1.21.1 |
| 43 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required: DSR 1.21 25 mm DSR 1.21.2 |
| 44 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts 'C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole DSR 21.2.10 |
| 45 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required. DSR 2.11 |
| 46 | S/F DP MCB IsolatorSupplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. DSR 2.12 40 Amp DSR 2.12.1 |
| 47 | S/F DP MCB IsolatorSupplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. DSR 2.12 63 Amp DSR 2.12.2 |
| 48 | Supplying and fixing following way, SP&N, sheet steel, MCB distribution board, 240 Von surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) 6 way, Double door DSR 2.3.1 |
| 49 | FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 50 | Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. DSR 1.45 |
| 51 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep. DSR 1.50.1 |
| 52 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0. Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. DSR 19.1 |
| 53 | Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. UPSOR Ch.14, 1413, CAT-AAA |
| 54 | Provision for sign board |
| 55 | Provision of photography |