| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group AQty. For NESD-IQty. For NESD-II |
| 2 | Group BQty. For NESD-IQty. For NESD-II |
| 3 | Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Qty. For NESD-IQty. For NESD-II |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wireQty. For NESD-IQty. For NESD-II |
| 5 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wireQty. For NESD-IQty. For NESD-II |
| 6 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire Qty. For NESD-IQty. For NESD-II |
| 7 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wireQty. For NESD-IQty. For NESD-II |
| 8 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group AQty. For NESD-IQty. For NESD-II |
| 9 | Group BQty. For NESD-IQty. For NESD-II |
| 10 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mmQty. For NESD-IQty. For NESD-II |
| 11 | 3 x 4 sq. mmQty. For NESD-IQty. For NESD-II |
| 12 | 6 x 4 sq. mmQty. For NESD-IQty. For NESD-II |
| 13 | 3 x 6 sq. mmQty. For NESD-IQty. For NESD-II |
| 14 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mmQty. For NESD-IQty. For NESD-II |
| 15 | 25 mmQty. For NESD-IQty. For NESD-II |
| 16 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.100 mm X 100 mm X 60 mm deepQty. For NESD-IQty. For NESD-II |
| 17 | 180 mm X 100 mm X 60 mm deepQty. For NESD-IQty. For NESD-II |
| 18 | 200 mm X 125 mm X 60 mm deepQty. For NESD-IQty. For NESD-II |
| 19 | 200 mm X 300 mm X 60 mm deepQty. For NESD-IQty. For NESD-II |
| 20 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 A switchQty. For NESD-IQty. For NESD-II |
| 21 | 15/16 A switchQty. For NESD-IQty. For NESD-II |
| 22 | 3 pin 5/6 A socket outletQty. For NESD-IQty. For NESD-II |
| 23 | 6 pin 15/16 A socket outletQty. For NESD-IQty. For NESD-II |
| 24 | Bell pushQty. For NESD-IQty. For NESD-II |
| 25 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switchQty. For NESD-IQty. For NESD-II |
| 26 | 15/16 A switchQty. For NESD-IQty. For NESD-II |
| 27 | 3 pin 5/6 A socket outletQty. For NESD-IQty. For NESD-II |
| 28 | 6 pin 15/16 A socket outletQty. For NESD-IQty. For NESD-II |
| 29 | Bell pushQty. For NESD-IQty. For NESD-II |
| 30 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Qty. For NESD-IQty. For NESD-II |
| 31 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. Qty. For NESD-IQty. For NESD-II |
| 32 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mmX75 mm)Qty. For NESD-IQty. For NESD-II |
| 33 | 3 Module (100 mmX75 mm)Qty. For NESD-IQty. For NESD-II |
| 34 | 4 Module (125mmX75mm) Qty. For NESD-IQty. For NESD-II |
| 35 | 6 Module (200 mmX75 mm)Qty. For NESD-IQty. For NESD-II |
| 36 | 8 Module (125 mmX125 mm)Qty. For NESD-IQty. For NESD-II |
| 37 | 12 Module (200mmX150mm) Qty. For NESD-IQty. For NESD-II |
| 38 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.Qty. For NESD-IQty. For NESD-II |
| 39 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. Qty. For NESD-IQty. For NESD-II |
| 40 | Supplying and fixing PVC batten/ angle holder including connections etc. as required.Qty. For NESD-IQty. For NESD-II |
| 41 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double doorQty. For NESD-IQty. For NESD-II |
| 42 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).4 way (4 + 12), Double door Qty. For NESD-IQty. For NESD-II |
| 43 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single poleQty. For NESD-IQty. For NESD-II |
| 44 | Triple pole and neutralQty. For NESD-IQty. For NESD-II |
| 45 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A Qty. For NESD-IQty. For NESD-II |
| 46 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A Qty. For NESD-IQty. For NESD-II |
| 47 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 14 way, Double door SPN MCBDBQty. For NESD-IQty. For NESD-II |
| 48 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K 46 DELHI SCHEDULE OF RATE (E&M) 2025(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)24 -26watt Qty. For NESD-IQty. For NESD-II |
| 49 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminium alloy) blades, 30 cm long down rod, 2 nos.canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)Qty. For NESD-IQty. For NESD-II |
| 50 | Supplying and fixing T cover on the existing junction box/ wooden block including connections etc. as required.Qty. For NESD-IQty. For NESD-II |
| 51 | Supplying and Installation of heavy duty exhaust fan of 300 mm sweep 900 rpm with louvers/shutters in the existing opening i/c making the hole suitable the size of the above fan making good the damage, connection testing commisioning with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc as reqd.Qty. For NESD-IQty. For NESD-II |
| 52 | Supplying Installation, testing and commissioning of wall mouted bracket fan sweep 400 mm PVC body with air delivery 80 m3/min and 1300 rpm, including making connection with 3x1.5 sqmm copper conductor PVC insulated etc. complete as required.Qty. For NESD-IQty. For NESD-II |
| 53 | Supplying and fixing following rating, double pole, 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amp DP MCB Qty. For NESD-IQty. For NESD-II |
| 54 | Supplying and fixing two module piano stepped type electronic fan regulator on the existing phenolic laminated sheet of switch box including connections etc. as required. Qty. For NESD-IQty. For NESD-II |
| 55 | Supplying, Installation, testing and commissioning of pre-wired LED decorative wall mounted brushed nickel finish fixture with acrylic diffuser with B22 SS PPCP,suitable for 9-10 W LED lamp, having minimum 100 lumens per watt. CCT 5000K to 6000K, power factor >0.90, CRI > 70% , with 9-10 W LED Lamp, complete with all accessories for mounting directly on wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 9-10 watts LED decorative wall mounted brushed nickel FittingQty. For NESD-IQty. For NESD-II |
| 56 | Supplying, Installation, testing and commissioning of 9-12 watts, LED Mirror Light fitting of length 2 feet with diffuser complete with all accessories etc. directly on wall including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.Qty. For NESD-IQty. For NESD-II |
| 57 | Supplying and fixing ding dong call bell suitable for single phase, 230 volts, complete as requiredQty. For NESD-IQty. For NESD-II |
| 58 | Supplying and fixing roof ceiling fan round sheet cover on the existing junction box/ wooden block including connections etc. as required.Qty. For NESD-IQty. For NESD-II |
| 59 | Supplying and Installation of 250 mm dia PVC ventilation / fresh air fan alongwith louvers including making the hole to suitable the size of the above fan i/c making good the damage, connections, testing, commissioning etc as reqd.Qty. For NESD-IQty. For NESD-II |
| 60 | Supplying and drawing of 25 sq.mm FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.Qty. For NESD-IQty. For NESD-II |
| 61 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10%, P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim12 -15 wattQty. For NESD-IQty. For NESD-II |
| 62 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt Qty. For NESD-IQty. For NESD-II |
| 63 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).72 wattQty. For NESD-IQty. For NESD-II |
| 64 | 90 wattQty. For NESD-IQty. For NESD-II |
| 65 | 120 wattQty. For NESD-IQty. For NESD-II |
| 66 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).70 wattQty. For NESD-IQty. For NESD-II |
| 67 | 150 wattQty. For NESD-I 30Qty. For NESD-II 10 |
| 68 | 200 wattQty. For NESD-IQty. For NESD-II |
| 69 | 250 wattQty. For NESD-IQty. For NESD-II |
| 70 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A, 16 KA,TPMCCBQty. For NESD-IQty. For NESD-II |
| 71 | 125 A, 16 KA,TPMCCBQty. For NESD-IQty. For NESD-II |
| 72 | 150 A, 16 KA,TPMCCB Qty. For NESD-IQty. For NESD-II |
| 73 | 200 A, 25 KA,TPMCCB Qty. For NESD-IQty. For NESD-II |
| 74 | 250 A, 25 KA,TPMCCB Qty. For NESD-IQty. For NESD-II |
| 75 | 400 A, 35 KA,TPMCCBQty. For NESD-IQty. For NESD-II |
| 76 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.Qty. For NESD-IQty. For NESD-II |
| 77 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.Qty. For NESD-IQty. For NESD-II |
| 78 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.Qty. For NESD-IQty. For NESD-II |
| 79 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.Qty. For NESD-IQty. For NESD-II |
| 80 | Supplying and fixing of 3 Pole MNX-250 Power contractor having AC3 and AC1 rating 250 A and 300 A wtih 2 No+2 NC auxiliary contact suitable for 415V, 50Hz in existing cubicle panel board making connections etc. complete as required. Qty. For NESD-IQty. For NESD-II |
| 81 | Supplying and fixing of 3 Pole MNX-140 Power contractor having AC3 and AC1 rating 140 A and 160 A wtih 2 No+2 NC auxiliary contact suitable for 415V, 50Hz in existing cubicle panel board making connections etc. complete as required. Qty. For NESD-IQty. For NESD-II |
| 82 | Supplying and fixing of 3 Pole MNX-95 Power contractor having AC3 and AC1 rating 95 A and 160 A wtih 2 No+2 NC auxiliary contact suitable for 415V, 50Hz in existing cubicle panel board making connections etc. complete as required. Qty. For NESD-IQty. For NESD-II |
| 83 | Supplying and fixing of following size Power contactor and timer suitable for 415V, 50Hz in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Power contractor M.L.-4 3 pole, 100A Qty. For NESD-IQty. For NESD-II |
| 84 | Power contractor MCX-23, 4 pole, 130A Qty. For NESD-IQty. For NESD-II |
| 85 | Astro mini Timer SwitchQty. For NESD-IQty. For NESD-II |
| 86 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)Qty. For NESD-IQty. For NESD-II |
| 87 | 4 X 16 sq. mm (28mm)Qty. For NESD-IQty. For NESD-II |
| 88 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)Qty. For NESD-IQty. For NESD-II |
| 89 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) Qty. For NESD-IQty. For NESD-II |
| 90 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.Qty. For NESD-IQty. For NESD-II |
| 91 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm Qty. For NESD-IQty. For NESD-II |
| 92 | Above 35 sq. mm and upto 95 sq. mm Qty. For NESD-IQty. For NESD-II |
| 93 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) Qty. For NESD-IQty. For NESD-II |
| 94 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV/LED street light fitting on wall /pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. Qty. For NESD-IQty. For NESD-II |
| 95 | Supplying, Installation, testing and commissioning of prewired 35-40 Watt LED post top lantern fitting having die cast aluminium body with minimum 100 lumens per watt suitable for cool day-light white having CCT 5700K with IP 65 complete with all accessories etc. directly on existing pole , including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as requiredQty. For NESD-IQty. For NESD-II |
| 96 | Supplying and drawing following sizes of PVC sheathed & XLPE insulated copper conductor multicore unarmoured cable of 1100 Volts conforming to IS 7098 (Part 1) 1988 with upto Date Amendments in the existing poles and bracket from cable termination connector to the fitting i/c providing suitable lugs connections etc. as reqd.3 core 1.5 sq.mm Qty. For NESD-IQty. For NESD-II |
| 97 | Providing and fixing of following pole connector with accessories in the existing poles:-a) Supply & fixing 6 mm thick laminated mounted sheet inside the window mounted .b) Supply and fixing 63 amps. terminal block suitable for 25 sq. mm conductor on DIN channel i/c pdg. and fixing DIN channel of suitable length - 2 Nos. on the existing laminated sheet. c) Supply & fixing of 6 amp. SP MCB 'C' characteristics Curve - 1 No, etc. Qty. For NESD-IQty. For NESD-II |
| 98 | Provision for pole / wall mounted box (300x200x105) mm size made out of (SMC) sheet moulding compound dust & weather proof with front openable hinged type cover with locking arrangement i/c providing & fixing of following accessories on existing pole / wall with suitable arrangement as required.a) 32 Amp 5 Way connector with bakelite base.b) 6 Amp SP MCB 'C' Curve (10 KA) - 1 No.c) Earth Studs - 2 Sets.d) 40 x 5 mm clamp with 2 Nos. 3/8\\" Nut & Bolts - 1 Set as required.e) Push & Clip handle to close/open - 1 No. Qty. For NESD-IQty. For NESD-II |
| 99 | Rewinding and reparing of 15 HP submersible monoblock pump motor with superior quality of copper conductor winding wire after cutting the old burnt wire, varnishing, baking, i/c refixing, realignment, G.M. bearing bust-04 Nos, Water seal / cable seal -04 Nos, Thrust plate- 02 Nos, Thrust bearing-01 Nos, C.I. Impeller-01 Nos, Rotar sleave turning / grinding- 01 No etc. i/c dismantling and less credit of dismentle material and making connection, testing etc. i/c overhauling of pumpset etc. complete as reqd. .Qty. For NESD-IQty. For NESD-II |
| 100 | Repairing of existing 75 HP, 3 phase, 415V, Electrical Pump set with electric motor i/c replacement of Ball bearing 6309 SKF, CI shaft sleeves, SS gland stud with nut 12x85, Oild seal, Deflector (rubber), Set gasket, Set gland packing, Wear Ring (Nakxing), Shaft sleeves check nut, CI bearing Hoging DE /ND, SS pump shaft compact, including dismantling, assembling, commissioning and testing the same on load after making electric connections at site i/c site visit by Engineer and to and fro from site to workshop & back to site etc. complete with less credit of dismantle material etc as required.Qty. For NESD-IQty. For NESD-II |
| 101 | Repairing of existing 55 KW 3 phase 415 volts AC induction motor after dismantling from its base frame with the help of chain pully block of tripod stand complete with disconnection of existing electrical connection and varnishing and replacing the sleaves baking of motor and replacement of 2 Nos ball bearing size 6314 C 3 and including assembling, commissioning and testing the same on load after making electric connections at site i/c site visit by Engineer and to and fro from site to workshop & back to site etc. complete with less credit of dismantle material etc as required.Qty. For NESD-IQty. For NESD-II |
| 102 | Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required.3 Core 10 Sq mm Flat CableQty. For NESD-IQty. For NESD-II |
| 103 | 3x6 Sqmm.Qty. For NESD-IQty. For NESD-II |
| 104 | Lifting of existing submersible bore well / open well 3 HP to 15 HP capacity Pump set from the bore well with the help of chain pulley block & tripod stand i/c cartage charge at site from the work shop.Qty. For NESD-IQty. For NESD-II |
| 105 | Lowering of 3 HP to 15 HP capacity bore well/open well pumpset in the bore well with the help of chain pulley block and tripod stand i/c cartage charge pump set from work shop to site.Qty. For NESD-IQty. For NESD-II |
| 106 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :50 mm diaQty. For NESD-IQty. For NESD-II |
| 107 | 65 mm diaQty. For NESD-IQty. For NESD-II |
| 108 | 80 mm diaQty. For NESD-IQty. For NESD-II |
| 109 | 150mm dia.Qty. For NESD-IQty. For NESD-II |
| 110 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 50 mm diaQty. For NESD-IQty. For NESD-II |
| 111 | 65 mm diaQty. For NESD-IQty. For NESD-II |
| 112 | 80 mm diaQty. For NESD-IQty. For NESD-II |
| 113 | 150mm dia.Qty. For NESD-IQty. For NESD-II |
| 114 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :150 mm diaQty. For NESD-IQty. For NESD-II |
| 115 | 200 mm diaQty. For NESD-IQty. For NESD-II |
| 116 | Supplying & lowering of 15 HP/11kw Open well submersible pump set capable of delivering 19.5-4 LPS at a head of 8-40 mtrs for operation on 415 volts, 3 phase, 50 Hz, AC supply, in the existing open well with the help of chain pulley and tripod stand i/c providing of GI nipple, flanges, GI nut and bolt, gasket and providing & fixing of cable jointing kit etc as reqd .Qty. For NESD-IQty. For NESD-II |
| 117 | SITC of 15 HP/11 kw fully automatic star delta Submersible Pump Starter having relay range 11-18A suitable for 415V 50Hz, 3 phase motor complete with sheet enclouser, ammeter, voltmeter, start stop push button, on off LED indication lamp, auto mannual slector switch and all other accessories including connections & testing etc complete as required.Qty. For NESD-IQty. For NESD-II |
| 118 | S/I/T/C of non-clog submersible sewage motor pump set not more than 7.5 Kw/10 HP for handling muddy water containing sand & silt etc up to 10% of solid content alongwith capable to discharged/handle the solid material/gravels upto 25 mm to be used for liquid containing coarse solid sanctioned sewage . The pump shall have approximate discharge cross section of 65 mm of 1500-270 LPM at a head range of 4-22 mtrs. The pump shall be suitable for operation on three phase 415V AC supply having nominal speed of 2900 +/- 1% RPM with semi open CI impeller, CI casing and body, SS shaft, delivery size 65 mm dia. TC/TC Mech. Seal, Dry type motor, The pump set shall be supplied with 10 mtrs cable etc. as required.Qty. For NESD-IQty. For NESD-II |
| 119 | SITC of 10 HP / 7.5 kw fully automatic star delta Submersible Pump Starter having relay range 9-14A suitable for 415V 50Hz, 3 phase motor complete with sheet enclouser, ammeter, voltmeter, start stop push button, on off LED indication lamp, auto mannual slector switch and all other accessories including connections & testing etc complete as required.Qty. For NESD-IQty. For NESD-II |
| 120 | SITC of vertical type 3 phase 5HP/3.5KW sewage submersible pump of 2900 RPM , outlet size 65 mm having discharge capacity 625-260 LPM at a head range of 16-22 mtr alongwith capable to discharged/handle the solid material/gravels upto 30 mm to be used for liquid containing coarse solid sanctioned sewage.The pump shall be suitable for operation on three phase 415V AC supply having nominal speed of 2900 +/- 1% RPM with semi open CI impeller, CI casing and body, SS shaft, delivery size 50 mm dia. TC/TC Mech. Seal, Dry type motor, The pump set shall be supplied with 10 mtrs cable etc. as required.Qty. For NESD-IQty. For NESD-II |
| 121 | SITC of 5 HP DOL Starter (with wideband coil) having relay range 6-10 A suitable for 180-415V 50Hz, 3 phase motor complete with sheet enclosure, start stop push button, on off LED indication lamp and all other accessories including connections & testing etc complete as required.Qty. For NESD-IQty. For NESD-II |
| 122 | SITC of vertical type single phase 1.0 HP/0.75kw portable sewage submersible pump of single stage, having discharge capacity 312 LPM at a head range of 5 mtr suitable for operation in DOL system i/c lowering the new pump in the sump etc complete as reqd. Qty. For NESD-IQty. For NESD-II |
| 123 | SITC of 3 HP DOL Starter (with wideband coil) having relay range 4-6.5 A suitable for 180-415V 50Hz, 3 phase motor complete with sheet enclosure, start stop push button, on off LED indication lamp and all other accessories including connections & testing etc complete as required.Qty. For NESD-IQty. For NESD-II |
| 124 | Supply, installation, testing & commissioing of 5 HP three phase 50Hz submersible motor having suitable size of head 56-37, flow rate 10-24 M3/h, 50 mm delivery, RPM 2850, in the existing borewell with the help of chain pully block and tripod stand with connections of electrical starter and delivery line etc. complete as reqd. Qty. For NESD-IQty. For NESD-II |
| 125 | SITC of DOL Starter (with wideband coil) having relay range 9-14 A suitable for 180-415V 50Hz, 3 phase motor complete with sheet enclosure, start stop push button, on off LED indication lamp and all other accessories including connections & testing etc complete as required.Qty. For NESD-IQty. For NESD-II |
| 126 | SITC of 20 HP / 15 kw fully automatic star delta heavy duty Submersible Pump Starter having relay range 28-42A suitable for 415V 50Hz, 3 phase motor complete with sheet enclouser, ammeter, voltmeter, start stop push button, on off LED indication lamp, auto mannual slector switch and all other accessories including connections & testing etc complete as required.Qty. For NESD-IQty. For NESD-II |
| 127 | Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :50 mm diaQty. For NESD-IQty. For NESD-II |
| 128 | 65 mm diaQty. For NESD-IQty. For NESD-II |
| 129 | Supplying & Laying of one number XLPE insulated and PVC sheathed aluminium conductor, armoured underground power cable of 1.1 KV grade of following size on wall / surface as required.4x16 sq.mm Qty. For NESD-IQty. For NESD-II |
| 130 | Day to Day maintenance/Routine servicing of 50 LPH capacity RO system for one year by deputing one no. quilified technician & one no helper ( 10 AM to 6 PM ) for four visits per months or as when required at Gulabi bagh, Sindhora khurd and Sindhora kalan i/c replacement of below mentioned parts as per item no 68 (Labour considered in this item only) etc. complete as required. If contractor not attend the complaint in same day, a recovery of amounting to Rs. 2,000/- each complaint per day will be deducted from bill)50 LPH (5 Nos)Qty. For NESD-IQty. For NESD-II |
| 131 | Comprehensive maintenance of above mentioned RO system i/c supplying and replacement of all parts like sediment filter, cabon filter, micron Cartridge filter, membrane, flow switch, AC/DC adaptor, Booster pump, SV, FR, Piping and fitting accessories i/c testing etc complte as reqd. TDS of output water should be in range of (72-150). Labour for this item is considered in item No 67.50 LPH (5 Nos)Qty. For NESD-IQty. For NESD-II |
| 132 | Supply of following materials:- S.P. 5/6 A, one way modular switch, ISI marked Qty. For NESD-IQty. For NESD-II |
| 133 | S.P. 15/16 A, one way modular switch, ISI marked Qty. For NESD-IQty. For NESD-II |
| 134 | 3 pin 5/6 A modular socket outlet, ISI markedQty. For NESD-IQty. For NESD-II |
| 135 | 6 pin 15/16 A modular socket outlet, ISI markedQty. For NESD-IQty. For NESD-II |
| 136 | Stepped type Modular Fan regulator (2 module)Qty. For NESD-IQty. For NESD-II |
| 137 | S.P. 5/6 A, one way switch, piano type ISI marked Qty. For NESD-IQty. For NESD-II |
| 138 | S.P. 15/16 A, one way switch, piano type ISI marked Qty. For NESD-IQty. For NESD-II |
| 139 | 3 pin 5/6 A socket outlet, piano type ISI marked Qty. For NESD-IQty. For NESD-II |
| 140 | 6 pin 15/16 & 5/6 A socket outlet, piano type ISI marked Qty. For NESD-IQty. For NESD-II |
| 141 | Modular base & cover plate for 1 or 2 ModuleQty. For NESD-IQty. For NESD-II |
| 142 | Modular base & cover plate for 3 ModuleQty. For NESD-IQty. For NESD-II |
| 143 | Modular base & cover plate for 4 ModuleQty. For NESD-IQty. For NESD-II |
| 144 | Modular base & cover plate for 6 ModuleQty. For NESD-IQty. For NESD-II |
| 145 | Modular base & cover plate for 8 ModuleQty. For NESD-IQty. For NESD-II |
| 146 | Modular base & cover plate for 12 ModuleQty. For NESD-IQty. For NESD-II |
| 147 | 24-26 watt LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)Qty. For NESD-IQty. For NESD-II |
| 148 | 12-15 Watt LED Down lighter (SMD Type) (System lumen efficacy ≥120 <135 lm/Watt), Powder coated die cast /Extruded aluminium Body including trim with Aluminium ReflectorQty. For NESD-IQty. For NESD-II |
| 149 | 40 A, rating, 2 pole RCCB, 30mAQty. For NESD-IQty. For NESD-II |
| 150 | 63 A, rating, 2 pole RCCB, 30mAQty. For NESD-IQty. For NESD-II |
| 151 | Decorative wall bracket fitting fixture made up of polycarbonate with 9 watt LED LampQty. For NESD-IQty. For NESD-II |
| 152 | 63 Amp DP MCBQty. For NESD-IQty. For NESD-II |
| 153 | 40 Amp DP MCBQty. For NESD-IQty. For NESD-II |
| 154 | Ding dong bellQty. For NESD-IQty. For NESD-II |
| 155 | Fish BellQty. For NESD-IQty. For NESD-II |
| 156 | 2.5 MFD capacitorQty. For NESD-IQty. For NESD-II |
| 157 | Fan Regulator 2 Module socket size Piano TypeQty. For NESD-IQty. For NESD-II |
| 158 | Less credit for dismantle material received from the work.Copper Wire assortedQty. For NESD-IQty. For NESD-II |
| 159 | 5/15 switch,socket, bellpush, regulatorQty. For NESD-IQty. For NESD-II |
| 160 | Holder assortedQty. For NESD-IQty. For NESD-II |
| 161 | DB AssortedQty. For NESD-IQty. For NESD-II |
| 162 | SP, SPN MCB AssortedQty. For NESD-IQty. For NESD-II |
| 163 | Ceiling fanQty. For NESD-IQty. For NESD-II |
| 164 | Exhaust FanQty. For NESD-IQty. For NESD-II |
| 165 | 63 Amp DP MCBQty. For NESD-IQty. For NESD-II |
| 166 | Batten / wall bracket / Mirror light AssortedQty. For NESD-IQty. For NESD-II |
| 167 | Assorted Down lighterQty. For NESD-IQty. For NESD-II |
| 168 | Assorted street lightQty. For NESD-IQty. For NESD-II |
| 169 | Assorted Flood lightQty. For NESD-IQty. For NESD-II |
| 170 | Assorted GI boxQty. For NESD-IQty. For NESD-II |
| 171 | MCCB AssortedQty. For NESD-IQty. For NESD-II |
| 172 | Assorted Power contractor Qty. For NESD-IQty. For NESD-II |
| 173 | Analog Timer SwitchQty. For NESD-IQty. For NESD-II |
| 174 | Assorted Post top light fittingQty. For NESD-IQty. For NESD-II |
| 175 | Assorted wall fanQty. For NESD-IQty. For NESD-II |
| 176 | Assorted BellQty. For NESD-IQty. For NESD-II |
| 177 | Assorted pump starterQty. For NESD-I - 2Qty. For NESD-II - 7 |
| 178 | 10 HP Sewage submerbile pumpQty. For NESD-IQty. For NESD-II |
| 179 | 5 HP submerbile pumpQty. For NESD-IQty. For NESD-II |
| 180 | 2 HP sewage submerbile pumpQty. For NESD-IQty. For NESD-II |
| 181 | 2x2 panel lightQty. For NESD-IQty. For NESD-II |
| 182 | Assorted sulice valveQty. For NESD-IQty. For NESD-II |
| 183 | Assorted butterfly valveQty. For NESD-IQty. For NESD-II |
| 184 | Assorted NRV valveQty. For NESD-IQty. For NESD-II |
| 185 | B Class medium duty GI pipeQty. For NESD-IQty. For NESD-II Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail