| 1 | Demolition stone rubble masonery manually/ by mechnical means i/c stacking of serviceable materials and disposal of unserviceable maretials with in 50mtr lead as per direction of Engineer in charge i/c Mud mortar including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 2 | Demolition cement conc.manual/ mechnical means above G.L up to floor two level i/c stacking serviceable materials and disposal of un serviceable materials up to 20 mtr lead including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 3 | Desmentling wood work in frame in frames trusses purlins and rafter up to 10 mtr. 5 mtr serviceable materials and disposal of unserviceable maretials with in 50mtr lead as per direction of Engineer in charge of sectional area below 40Sqm centimter. |
| 4 | Dismentling roofing i/c ridges hips valley and gutter etc. i/c stacking of serviceable materials and disposal of unserviceable maretials with in 50mtr lead as per direction of Engineer in charge in GS sheet |
| 5 | Excavation work by machnical means( Hydraulic exczvztor/ manual means in foundation, trenches etc. in earth work in all kind of soil lifts upto 1.50 mtrs. Stacking the excavated soil not more than 3 mtrs. Clear from the edge of excavation and then returning the stacked soil in 15cm layers when required into plinths sides of foundation etc. consolidating each deposited layer by ramming, watering and then disposing of all surplus excavated earth as directed upto 5KM leads including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 6 | Providing & laying cement concrete 1:4:8 (1cement: 4sand: 8graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in walls including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 7 | Random rubble/ploygonal rubble (uncoursed/ brought to courses) with hard stones of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 (1cement: 6sand: 12graded stone aggregate 20mm nominal size) at plinth level in cement mortar 1:6 (1cement: 6sand). in retaining walls including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 8 | Providing from work with steel plates 3.15mm thick weled with angle iron in frame 30x30x5mm so as to give a fair finish including levelling centering, shuttering strutting and propping etc. With wooden battens and ballies, hight of propping and cenring below supporting floor two ceiling and removal of the same for instu- reinforced concrete and plain concrete work in:- a) Foundation, footing bases of colums etc. and mass concrete. |
| 9 | b) Columns, pilasrs, post and struts, square, rectangular or polygonal in plain. up to floor two level |
| 10 | c) Beams, cantilevers, girders & lintels, sides & soffits or beams, beam haunchings, cantilvers bressumers and lintels not exceeding 1mtrs in depth. |
| 11 | c) flat surface such as soffit of suspended floor roof landing up to floor two level |
| 12 | e) vartical surface such as wall any thickness for septic tank wall |
| 13 | Providing & laying cement concrete work 1:1.5:3 (1cement: 1.5sand: 3graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in all hight including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. (a) Foundation footing bases of columns etc. and mass concrete. Qtrs/bull shed |
| 14 | b) Columns, pilasrs, posts and struts, square, rectangular or polygonal in plain. up to floor two level |
| 15 | c) Suspending floors roofs landing & shelves and their supports, balconies, beams, girders, bressumers and their cases (except spiral cantilever upto floor two level. |
| 16 | Providing tor steel reinforcement for RCC work including bending, binding and placing in postion complete upto floor two level including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 17 | Providing and laying cement concrete 1:3:6(1cement:3sand:6graded stone agregate 20mm nominal size ) and curring complete excluding cost of form work in foundation and plinth including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 18 | Prooviding wood work in frames of doors, windows, clearestory windows and other framed and fixed in postion. 1st. Class hard wood/sal wood including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 19 | Prooviding 40 X 3mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia bolts, nuts and wooden splug and immeging in cement concrete block 10x10x15 cms. 1:3:6 (1cement: 3sand: 6graded stone aggregate 20mm nominal size) including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 20 | Providing & fixing panelled glazed or panelled and glazed shutters for doors windows and clearstory windows including black enamelled iron butt hinges with necessary screws. 35mm thick Ist. Class Deodar Wood. |
| 21 | Providing and fixing wire guage shuter using galvanised m.S> wire guage of I.S. guage designation 85G with wire of dia 0.56mm for door windows and clearstory windows with necessary screws 30 mm thick second class deodar wood |
| 22 | Providing & fixing aluminium sliding door bolt anodized transparent or dyed to required colour and shade with bolts and nuts screws etc. complete (i) 300mm x 16mm. |
| 23 | Providing and fixing aluminium tower bolts (barrel type ) anodized transparent or dyed to required shade & colour.(a)200 x 10mm |
| 24 | (b) 150x10mm |
| 25 | Prooviding and fixing aluminium finshed brass handles with nuts and secrews etc complete. (a) 125mm. |
| 26 | Providing and fixing oxidized MS hooks and eyes 250mm |
| 27 | P/F 100mm bright finished brass floor door stopper with rubber cushion screws etc to suit shutter thickness complete |
| 28 | P/F bright finished door closer 150mm |
| 29 | Brick work using common clay burnt building bricks in superstructure avobe ground level in cement mortar 1:6 (1cement: 6 sand) 1st class bricks upto all hight. |
| 30 | Providing and fixing precoated galvenised iron profile sheet ( size ,shape and pitch of carrugation as approved by 0.50 mm (+0.05%) total coated thickness 0.60mm thick prepainted steel sheet in roofing with hot dipped metallic zink coated 120 gram per Sqm as per IS: 277in 240 mpa steel grade 5-7 microns epoxy primer on both side of sheet sheet With top coat of regular modified polyster(RNP)organic coating of 20 microns over 5microne primer coating to Back coat of polyster of 5 microns over 5 microne primer coating i/c fixing with prepainted iron J or L hooks,bolts And nuts 6mm dia meters with prepainted limpet and rubber washer complete with all assesories as required including carriage of materials by all modes of transportation, as per PWD specifications and as directed by the Engineer-in-Charge, including all incidentals. |
| 31 | Providing and fixing precoated galvenised steel sheet roofing accessaries 12.51.1 Ridges plain (500-600mm) and as per direction of Engineer in charge |
| 32 | Steel work welded in built up sections, trusses and framed work, i/c cutting, hosting, fixing in position and appling a priming coat of red lead paint and as per direction of Engineer in charge :- (a) In trusses and trussed purlins in building. |
| 33 | b) gretting frames guard bar ladder railing brackets and similar work |
| 34 | Providing and fixing M.S. B.P sheet 1.66mm to 2mm thick in eaves board/facia/soffits/ceiling i/c cutting fixing & welding to steel roof members & appling a coat of red lead primer complete as per the instruction of Engineer incharge.( base mambers of steel work shall be measured & paid sepertely. |
| 35 | Providing and fixing M.S. grills of required patterns in woodan frames of windows etc. With M.S. flats, square or round bars with round headed bolts and nuts or by screws. Plain grill. and as per direction of Engineer in charge |
| 36 | 15mm cement plaster in singale coat on the rough side of brick/concrete/stone walls for interior plastring upto floor two level including arrrises, internal rounded angles, chamfers and/or rounded angle not exceeding 80mm in girth and finished evehn and smooth in cement mortar 1:6(1cement :6sand) and as per direction of Engineer in charge |
| 37 | 15mm cement plaster in singale coat on the fair side of brick/concrete/stone walls for interior plastring upto floor two level including arrrises, internal rounded angles, chamfers and/or rounded angle not exceeding 80mm in girth and finished evehn and smooth in cement mortar 1:6(1cement :6sand) and as per direction of Engineer in charge |
| 38 | Providing and fixing in position collapsible shutter with vertical channel 200x10x2mm and braced with flat iron daigonal 20x5mm size with top and bottom rail of T iron 40x40x6mm with 38mm dia steel pulley complete with bolts and nuts and locking arrangement stopper handle including applying primer coat of red lead paint and as per direction of Engineer in charge |
| 39 | Providing and fixing 10mm thick antiskid water proof stain and impact resistant heavy duty vitrified tiles Nitco or equivalent 600x600mmx10mm manufactured of approved shade and colour in flooring, trade of steps and landing laid over12mm thick cement mortor 1:3 ( 1 cement:3 sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete and as per direction of Engineer in charge |
| 40 | P/L ceremic glazed floor tile 300x300 mm thickness to be specified by the manufacture) of 1st quality conferming to IS : 15622 of approved make in colour such as white Ivory, gray fume red brown,laid on 20mm tick cement mortar 1:3(1cement: 3sand) and jointed with cement slurry. Kajaria/Oriented Make. |
| 41 | Providing plinth protection under layer of 75mm thick bed of dry brick/stone aggregate 40mm nominal size well ramed and consolidated and ground with fine sand including prepration of ground finished with 50mm thick cement concrete 1:3:6 (1cement:3sand :6graded stone aggregate 20mm nominal size.) and fixing oxidized M.S hooks and eyes 150mm long and as per direction of Engineer in charge |
| 42 | Appling birla white putty of approved brand and manufacture on wall surface. surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final metter finish to the surface complete and as per direction of Engineer in charge |
| 43 | Appling priming coat over new wood and wood based surface after and including prepairing the surface by thoroughly cleaning oil, dirt and other foreign matters sand papered knotting. Ready mixed pain brushing wood primer pink as per direction of Engineer in charge |
| 44 | Painting two coat (excluding priming coat) on new wood and wood based surfaces with readymixd paint brushing to give an even shade including cleaning of all dirt, dust and other foresign matter sand pepering and stopping with ready mixed paint and as per direction of Engineer in charge |
| 45 | Appling priming coat over new steel and other matel surfaces after and including prepairing the surface by thoroughly cleaning oil grease, dirt and other foreign matters sand papered knotting Ready mixed pain brushing red oxide/zink oxide chrome and as per direction of Engineer in charge |
| 46 | Painting two coat (excluding priming coat) on new steel and other metal surface under coat with ready mixed paint brushing to give an even shade including cleaning of all dirt, dust and other foresign matter with ready mixed paint other than white and as per direction of Engineer in charge |
| 47 | Distempering (two coats) with oil boud washable disremper of approved brand and manufacture and of required shade on decorated wall surfaces to give an even shade over and including a priming coat with distemper primer of approved brand and menufacture after thoroughly brushing the surface free from mortar dropping and other forign matter and also including preparing the surface even and sand papered smooth priming coat with distemper primer as per direction of Engineer in charge |
| 48 | Finishing wall with water proofing cement paint Apex of Asian brand and manufacture and of required shade on decorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials as per direction of Engineer in charge |
| 49 | P/F on wall face unplasticied Rigid PVC rain water pipe conferming to IS: 13592 Type-A i/c jointing with seal ring conferming to IS:5382 leaving 10mm gap for thermal expension, (i) single socketed pipes 110mm as per direction of Engineer in charge |
| 50 | P/F on wall face unplasticied Rigid PVC moulded fittings accesseries for rain water pipe conferming to IS: 13592 Type-A i/c jointing with seal ring conferming to IS:5382 leaving 10mm gap for thermal expension, (i) plain bend 110mm as per direction of Engineer in charge |
| 51 | P/F m.s. holder bat clamps of approved design to CI AND SCI pipes 100mm dia as per direction of Engineer in charge |
| 52 | Neat cement slurry on pilaster surface complete as per direction of Engineer-in-Charge. |
| 53 | P/F white vitrous china pedestal Type water closet squatting pan ( European type WC pan ) with seat and lid, 10litrs low level white PVC flushing cistern, i/c flush pipe with manually controlled device ( handle lever) conferming to IS:7231 with all fittings and fixture complete ( earth work , bed conc. Foot rest and trap to be measured and paid for separetaely W.C pan with ISI marked white solid pilastic seat and lid.as per direction of Engineer in charge |
| 54 | P/F PVC P'S' trap for water closet ( aquatting pan) ISI marked i/c jointing the trap with the pan and PVC pipe with approved adhesive etc. complete. |
| 55 | P/F vitrous china wash basin with single holes for piller tap with C.I or M.S brackets painted white i/c cutting holes and making good the same but excluding fittings 630x450mm as per direction of Engineer in charge |
| 56 | Providing and fixing PVC connection 45cm length 15mm dia. as per direction of Engineer in charge |
| 57 | Providing & fixing 600 x 450mm bevelled edge mirror of superior glass mounted on 6mm thick AC sheets or plywood sheet and fixed to wooden plugs with CP brass screws and washers of standard quality. |
| 58 | P/F chromium plated brass soap dish with brackets fixed to wooden cleats with C.P Brass screw. as per direction of Engineer in charge |
| 59 | Providing and fixing towel rail complete with C.P. brass bracket fixed to wooden plugs with C.P. brass 750mm x 20mm. as per direction of Engineer in charge |
| 60 | Providing & fixing CP brass bib tap with capastan head 15mm dia. (Jaguar/Excel Make). as per direction of Engineer in charge |
| 61 | Providing & fixing CP stop cocks 15mm dia (Jagour/excel Make). as per direction of Engineer in charge |
| 62 | Providing & fixing C.P. pillar tap with capaston head. 15mm dia. as per direction of Engineer in charge |
| 63 | Providing & fixng PVC waste pipe for wash basin or sink 32mm dia. as per direction of Engineer in charge |
| 64 | P/F 100mm sand cast iron grating for gully floor or nahani trap as per direction of Engineer in charge |
| 65 | P/F GI pipes complete with Gi fittings and clamps i/c making good the wall etc, concealed pipe i/c painting with anti corrosive bitumen making good wall 15mm dia nominal bore as per direction of Engineer in charge |
| 66 | Providing & fixing pvc floor trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete i/c cost of cutting & making good the walls and floors as per direction of Engineer in charge . 100mm nominal dia. |
| 67 | P/F 8mm dia CP/SS jet with flexible tube up to 1.00 mtr long for European WC sheet as per direction of Engineer in charge |
| 68 | P/F soil waste and ventilating pipees :- 100mm dia PVC pipe |
| 69 | P/F PVC accesseries :- a) P/F SCI plain bend 100mm |
| 70 | b) P/F double equal branch 100x100x100mm |
| 71 | c) P/F single equal plain junction 100x100x100mm |
| 72 | d) P/F coller 100mm |
| 73 | P/F PVC water storage tripal core tank 1000 lltr capacity complete in all respect as per direction of Engineer in charge |
| 74 | Constructing Man holes with RCC top slab 1:2:4 ( 1cement @ sand :4 graded stone agg 20mm nominal size foundation conc 1:4:8 in side plastring 1:3 in side size 800x800 500mmdeep 200mm thick brick wall in cement mortar 1:3 ( 1cement :3sand ) as per direction of Engineer in charge |
| 75 | P/F half round PVC pipe for gutter complete in all respect 150mm as per direction of Engineer in charge |
| 76 | Cement conc. Flooring 1:2:4 ( 1 cement: 2 sand :4 graded stone agg. 20 mm nominal size laid in one layer finished in neat coat of cement slurry 40mm thick as per direction of Engineer in charge Please Enable Macros to View BoQ information |