| Sl. No. | Item Description |
| 1 | Schedule A-SITE DEVELOPMENT & ROAD / RAIL WORKS |
| 2 | Schedule-C-CAST-IN-SITU & PRECAST WORKS |
| 3 | Schedule D-Steel Works |
| 4 | Schedule E-AT GRADE PORTION (CONCRETE & STEEL WORKS) |
| 5 | Schedule F-PRE ENGINEERED BUILDING (PEB) STEEL |
| 6 | Schedule G-ARCHITECTURAL WORKS |
| 7 | Schedule H-PUBLIC HEALTH ENGINEERING (CIVIL) |
| 8 | Schedule I-EFLUENT AND SEWAGE TREATMENT PLANT(ETP & STP) Works |
| 9 | Schedule J-ELECTRICAL WORKS |
| 10 | Schedule K- FIRE DETECTION AND ALARM SYSTEM |
| 11 | Schedule L-HVAC WORKS |
| 12 | Schedule M-FIRE FIGHTING SYSTEM |
| 13 | Schedule N-PLUMBING PUMPS AND WATER TREATMENT PLANT |
| 14 | Schedule O-COMPRESSED AIR SYSTEM |
| 15 | Schedule P-Local Area Network (LAN) |
| 16 | Schedule Q-ACCESS CONTROL SYSTEM |
| 17 | Schedule R-CIVIL WORKS |
| 18 | Schedule S- BILL OF QUANTITIES FOR M&P WORKS |
| 19 | Schedule T-MISCELLANEOUS WORKS |
| 20 | Schedule U-ELEVATED TEST TRACK 400M |
| 21 | Schedule V-ITEMS UNDER SCHEDULE OF RATE PUBLISHED BY GOVERNMENT DEPARTMENTS |
| 22 | Total SOLADEVANHALLI DEPOT- SCHEDULE A***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. SI.No. Description of Item Unit Qty Rate (***Refer Note) Amount INR SCHEDULE A : SITE DEVELOPMENT & ROAD / RAIL WORKS |
| 23 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding150 mm in thickness complete as per specifications. By Mechanical Means, In area of light jungle. MORTHSpecification No. 201. |
| 24 | Removal of unserviceable soil (debris) including excavation loading and disposal including all leads and lifts. |
| 25 | Cutting of trees girth including cutting of trunks, branches and removal of stumps, roots stacking of serviceable materials with all lifts and leads and earth filling in the depressions /pit, complete as per specifications. MORTH Specification No. 201 |
| 26 | 300mm to 600mm |
| 27 | 600mm to 900mm |
| 28 | 900mm to 1800mm |
| 29 | 1800mm to 2700mm |
| 30 | Earth work excavation in Ordinary/hard soil for road work / railway work, minor drains, cable trench etc. Either mechanically or manually as per drawing and technical specification, Including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, back filling the excavation earth to the extent required and utilizing/transporting the remaining earth including all leads and lifts including cost of labour, materials and HOM etc., complete. |
| 31 | Construction of embankment with approved material Gravel/Murrum with all lifts & leads, transporting to site, spreading, grading to required slope and compacted in layers not exceeding 200mm to meet requirement of Table No. 300-2 complete as per specifications (including cost of earth, watering charges & compaction by vibratory roller to 95% of proctor's density and minimum CBR value 5%) MORTH Specification No. 305. |
| 32 | Construction of embankment with approved material deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300- 2 complete as per specifications. Which includes, watering charges & compaction by vibratory roller. |
| 33 | Mechanical manufacturing of blanketing material by using only hard and durable stone crushed in mechanical crusher to different gradations, wet mixing of the same in designed proportion in Pug mill or wet mix plant to have uniform gradation including all incidental transportation, laying over finished formation in uniform layer(s) with motor grader, compaction with suitable vibratory roller to specified density and finishing to correct profile, complete as per RDSO Specification No. RDSO/2020/GE: IRS-0004 with latest correction slips. Note: This item shall be used only when entire constituent of blanketing material is mechanically manufactured by crushing of hard and durable stone into desired gradation of designed proportion. |
| 34 | Providing and laying of Filter media. with granular materials / stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MORTH Specifications to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provide over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition as per drawing and Technical Specifications including the· cost of materials, labour, HOM, watering, transportation, lead, lift, loading, unloading, etc., complete as per specifications. |
| 35 | Construction of sub-grade and earthen shoulders with approved I material Gravel/Murrum with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table No. 300-2 complete as per specifications (including cost of earth, watering charges & compaction by vibratory roller to 97% of proctors density and minimum CSR value 10%) MORTH Specification No: 305 |
| 36 | Granular Sub base with close graded materials by Plant Mix Method (Table:- 400-1, MORTH specification): Construction of granular sub base by supplying, laying, spreading & compacting of close graded material, mixing in a wet mix plant of 75 ton capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8- 10 tonnes to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, with all lead & lifts etc., complete to achieve minimum CBR value of 30% (Compacted thickness) - Grading-5. MORTH specification: 401. |
| 37 | Providing, laying, spreading and compacting crushed stone aggregates of granite/basalt to wet mix macadam specifications including pre mixing the water at OMC In mechanical mix plant carriage of mixed materials by tipper to site, laying in uniform layers with paver in sub- base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density, with all lead & lifts etc. complete as specifications. MORTH specification: 406. |
| 38 | Providing and laying dense graded bituminous macadam using I Crushed aggregates of specified grading, premixed with VG30 grade bituminous binder and transporting the hot mix to the work site, laying to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete in all respects with all lead & lifts etc, complete as per specifications,. Clause 505 of MORTH(Using 120 TPH capacity Asphalt Batch Mix Plant with sensor paver, Gr-1, with 4% VG-30 bitumen). |
| 39 | Providing and laying bituminous concrete using crushed aggregates of specified grading, premixed with bituminous binder and. filler, transporting the hot mix to work site, laying with paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete in all respects complete for all respects with all lead & lifts etc. complete as per specifications. Clause 507 of MORTH. (Using 40/60 TPH capacity H.M.P. with sensor paver, Gr-1 with 5.2% VG-30 Bitumen). |
| 40 | Providing and applying primer coat with S.S. bitumen emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.60 kg/Sqm using mechanical means with all lead &lifts etc. complete as per specifications. MORTH Specification No. 502. |
| 41 | Supplying and applying tack coat on prepared surface using Rapid setting bituminous emulsion (RS1) complying with.) IS:8887 of approved quality and make including cleaning of road surface by mechanical broom and dusting by air compressor and spraying by bitumen distributer including cost of all materials, labour, hire ,charges of machinery, loading, unloading, stacking, etc. complete with all leads and lifts granular base such as WMM surface treated with primer (dry and hungry)@ min 2.5 kg/10 Sqm and on black topped surface@ min 2.0 kg/10 Sqm as directed. MORTH Specification No. 503. |
| 42 | Providing and filling in foundation with granite / trap broken metal 100 mm and down size with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all leads and lifts complete as per specifications. |
| 43 | Providing and laying of Brick bats (Brick Soling) of size 25mm to 100mm below flooring of the building including hand packing, ramming, watering, including cost of all materials and labour with all leads and lifts complete as per specificati_ons or as directed by Engineer. |
| 44 | Road marking with hot applied thermoplastic compound with. reflectorizing glass beads on bituminous surface: Painting the road surface using approved quality thermo plastic material (homogeneously composed of aggregates, pigment, resins and glass reflectorizing beads, conforming to clause-803.4.2.2 MORTH specifications) applied hot either by screeding or extension process at the rate of 5Kg/Sqm of painted surface using suitable machine capable of controlled preparation and laying with surface applicator of glass beads @ 250gms/Sqm allowing cooling to ambient pavement temperature, that shall produce an adherent pavement marking of minimum specified thickness of 2.5mm including barricading for traffic diversion as per IRC:35, cleaning the surface of dirt, dust and other foreign matter, demarcation at site, barricading for traffic diversion,traffic control including cost of all materials, labour, loading, unloading, lead, lift, transporting etc., complete.MORTH specification: 803. A sealing primer may be applied in advance on cement concrete pavement to ensure proper bonding. Any laitance and/or curing compound to be removed where paint is required to be applied on concrete surface. |
| 45 | Painting lines, dashes, arrows etc.,on Roads in two coats on New Work:-Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control complete as per specifications. i) Over 10 cm in width. MORTH Specification No. 803 |
| 46 | Road markers/ Road stud: Supply and lnstalltion of Moulded Shank Raised Pavement Markers made of polycarbonate and ABS(Acrylonitrile Butadiene Styrene) moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 kg tested in accordance to Specifications of Category A of MORTH Circular No RW/ NH/33023/10-97 - DO 111 Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 mm and height not less than 30 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation and complete as directed by theengineer. |
| 47 | Retro-Reflectorised Traffic Signs: Providing and fixing of retro - reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of high intensity grade sheeting vide Clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. |
| 48 | 600 MM Circle -TYPE XI |
| 49 | 600 MM Equilateral triangle - TYPE XI |
| 50 | 900 MM Octagon Stop Board - TYPE XI |
| 51 | Direction and Place Identification Signs upto 0.9 sqm Size Board: Providing and erecting direction and place identification retro- reflectorised sign as per IRC:67 made of high intensity grade sheeting vide Clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per aooroved drawing. |
| 52 | Direction and Place Identification Signs with size morethan 0.9sqm Size Board: Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide Clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm , 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing. |
| 53 | Over head Signs (Truss and Vertical Support): Manufacturing, Supply and installation of retro- reflective Over-Head Gantry signboards made out of cube corner micro prismatic grade sheeting confirming to Type XI standards of IRC:67:2012 fixed over 4mm thick Aluminium Composite Panel sheet, excluding the cost of Type XI retro- reflective sheeting and 4mm Thick ACP sheet with suitable back support frame over a designed support system of aluminum alloy or galvanised steel trestles and trusses of section type as per structural design requirements and approved plans complete as per specifications. Vertical and Lateral Clearance of the Gantry shall be as per IRC 67 2012 and as per Clause 800.2.2 and 800.2.3 and installed as per clause 800.2.7. |
| 54 | Over Head Sign Board : Supply and installation of retro- reflective Over-Head Gantry sign boards made out of cube corner micro prismatic grade sheeting confirming to Type XI standards of IRC:67:2012 specification & fixed over 4mm thick Aluminium Composite Panel sheet having minimum 0.30 mm thick aluminum skin on both sides excluding the cost of back support frame, vertical support and horizontal support and foundation as directed by the Engineer. |
| 55 | Provsion of Traffic Blinkers including Civil works |
| 56 | Providing, fixing, Rubber Rumble strips with width and depth of 250mmx25mm, Heavy duty model with unit weight as per IRC / MORTH standards, including cost of all material, fixtures, labour etc. complete, conforming to the Technical Specifications and as directed by the Engineer. |
| 57 | Traffic cones: Supplying of red fluorescent with white reflective sleeve traffic cones made of low density polyethylene (LOPE) material with a square base of 390x390x35mm and a height of 770mm, 4Kg in weight, placed at 1.5m interval all as per BS-873 including cost of all material, labour, loading, unloading, lead, lift, transportinq, etc., complete. |
| 58 | Back filling with Granular material behind abutment, wing wall, return wall and foundation trenches as per drawing in layers not exceeding 20cms in depth, compacting deposited material by plate compactor/power rammer after duly watering to achieve the desired degree of compaction, including cost of materials, labour, hire charge of machineries, transportation, with all lead and lifts, loading, unloading etc. complete. MORTH specification: 710. 1.4 of IRC: 78 & 2200. |
| 59 | Supplying and Fixing precast solid concrete kerb stones made out of M15/20(CC-1:2:4) and Finished with CM:1:3 Plastering and finishing,Cutting with all lead and lifts etc.complete size of 450x200x400 mm. Total of Schedule \\"A\\" 0.0 SOLADEVANHALLI DEPOT- SCHEDULE C***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. SI.No. Description of Item Unit Qty Rate (***Refer Note) Amount INR SCHEDULE C :CAST-IN-SITU & PRECAST WORKS |
| 60 | Providing & laying plain cement concrete M20/20 grade in open foundation, stepped foundation, combined footing, raft foundation, retaining walls, return walls, walls, U/G tank, culverts, below pile cap, drains, floorings, below grade slabs, tie beams, basements, levelling course or any other works as directed by the Engineer, etc., complete using granite/ trap/ basalt aggregates and clean sieved approved sand including mixing mechanically and required dosage of admixture In concrete for obtaining required workability and as per specifications, approved drawings, laid In layers not exceeding 15cms thick layers, as per drawing including cost of all material, form work/ shuttering, centering, scaffolding, dewatering during concreting.; vibrating, compacting, hire charges of machinery, all lead and lift, loading, unloading, transporting, stacking, curing, finishing the exposed faces etc., complete. |
| 61 | Providing & laying design mix M35/20 grade, reinforced cement concrete for following concrete works: Pile cap, Open Foundation / stepped foundation / Raft /Plinth beam ],Slabs, Column Heads, Stairs & Ramps , Walls etc. including excavation up to 4.0 m from lowest ground level through existing water bound macadam road / bituminous road / concrete road /soil/murrum/ hard rock /soft rock old structures below ground as encountered of all thicknesses, dismantling other structures, dead utilities, dewatering, pumping and bailing out water, strutting and shoring, formwork, backfilling in foundation with good earth/quarry dust/sand watering, compacting with a vibratory plate compactor complete as per specifications. The. Cost shall also include cutting / chipping of pile up to cut off level or up to good concrete and built up of pile up to required level. The cost includes loading, unloading and disposal of surplus excavated material along with pile heads using covered trucks to contractor's dumping yard with all leads and lifts and as directed by the Engineer. The contractor has to ensure that during transportation, the carried material does not spill out. Reinforcement shall be paid separately under relevant item. Rate shall include cost of using required dosage of admixture in concrete for obtaining required workability as per approval of Engineer, curing of concrete 10% of the amount shall be withheld and amount shall be released after disposal of excavated material including pile heads at contractor's dumging yard. |
| 62 | Providing and laying design mix M35/20 grade RCC in precast standard BSRP boundary wall panels of required size and thickness as per design and drawing with fluting pattern on one side and. exposed stone aggregate finish on other side including cost of centering and shuttering but excluding the cost of steel reinforcement and including form work, shuttering & moulds, laying, compacting by vibration & all work , hoisted and installed in all stages with necessary scaffolding with all lead & lifts etc. |
| 63 | Providing and laying design mix M35/20 grade RCC for precast drain , cable duct , I precast drain cover precast cable duct cover, precast covers for the chambers, precast platforms,columns , beams & slabs or any other precast elements using OPC with minimum cement content as per specification including compacting the concrete by surface/needle vibrator, centering, shuttering, propping; staging, curing, necessary tools, plants, machinery and all related operations etc. using steel shuttering & steel props. Rate shall include cost of providing grooves, chamfers, mouldings, cut-outs, lifting holes, necessary fixtures, insert plates, sleeves for various purposes, etc. complete as per drawings, specifications and as directed by the Engineer. Rate shall also include cost of using required dosage of admixture in concrete for obtaining required workability. Rate also includes casting , transporting, installation and fixing in position by using mechanical equipments including all lead and lift at all levels and incidential charges as per drawing and specifications or as directed by the Engineer complete. |
| 64 | Providing and laying flooring using fixed form paver of suitable size and specification over prepared sub-base with design mix of M35/20 grade 'RCC with minimum cement content as specified, including fixing expansion/construction joints, spreading, placing, finishing and compaction of concrete with the surface/needle vibrator, finishing with mechanized floating and troweling, laying surface to required slope and grade, all incidential works etc, complete all as per specifications and drawings. Rate includes cost of all materials, labour, curing, hire charges of machineries, with all leads & lift at all levels complete as per specification. Rate shall also ·includes cost of dosage of admixture for required workability.(Steel reinforcement shall be paid separately under relevant BOO items). For Grade Slab. |
| 65 | Extra over Item No. 7 of schedule C, for Vacuum De-watering System treatment including fixing of the channels/ side form and Setting them to the required level, 12/25 mm thick expanded polystyrene expansion/ isolation joints to the full thickness of the concrete, dewatering the surplus water using filter pads·& vacuum pumps, floating with a disc, power troweling with blades including all incidental work etc., complete. The VOS equipment shall be of TREMIX / AQUARIOUS TECH. or equivalent. The channel shall have holes of dia.. and intervals specified by Engineer and perpendicular at edges. Rate includes cost of all materials, labour, hire charges of machineries, with all leads & lift at all levels complete as per specifications. |
| 66 | Finishing with Epoxy paint on Vacuum Dewatered Concrete (in two layers) at all, locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete as per specifications and approved drawings. |
| 67 | Providing and laying design mix grade of concrete for RCC works (excluding the cost of reinforcement) for COLUMNS, BEAMS etc. above ground level, with 20 mm and down size aggregates of approved gradation hard broken granite, trap basalt or with any other approved hard aggregate, machine mixed, cost and conveyance of all materials, lead and lifts, consolidation, vibration, curing; steel form works, centering, scaffolding etc., finishing exposed faces in CM 1:3, 12 mm thick etc for Overhead Tank. |
| 68 | RCC M35 with 20 mm aggregate for level upto 30 M height, item Description as above. |
| 69 | Providing and laying design mix grade of concrete for RCC works for water retaining structures (Overhead Tank) as per relevant code with OPC cement (excluding the cost of steel reinforcement) for BOTTOM SLAB, SIDE WALLS, TOP SLAB over the staging above ground level, with 20 mm and down size of approved gradation hard broken granite, trap basalt or with any other approved hard aggreg·ate, machine mixed, cost and conveyance of all materials, lead and lifts, consolidation, vibration, curing, steel form works, centering, scaffolding etc., finishing exposed faces in CM 1:3, 12 mm thick and CM 1:3, 20 mm thick for inside with an admixture of water proofing, compound of approved quality for requisite proportion etc. testing as per directions, (Contractor will make his own arrangements for procuring water for testing) etc. for Overhead Tank. |
| 70 | RCC M35 with 20 mm aggregate for level at 30 M height, item Description as above. Total of Schedule \\"C\\" 0.0 SOLADEVANHALLI DEPOT-SCHEDULE D***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. Sl.No Description of Item Unit Qty Rate (***Refer Note) Amount INR Schedule D Steel Works |
| 71 | Providing TMT-500/550O grade steel bar reinforcement (conforming to IS:1786,HYSD Fe 5000 grade) at all heights & depth including straightening bars, cutting, bending, hooking binding with approved quality 18 gauge G.I binding wire, after placing in position tying, lapping and /or welding wherever required and anchoring to the adjoining members wherever necessary as per drawings (Laps , Hooks, spacer bars, standard bars, U-bars, chairs, bend deduction and Wastages shall not be measured and paid) including cost of all materials, bar bending charges, labour, lead & lifts etc., complete as per specifications and as directed including welding involved towards stray current protection effects as per the system approved by Engineer. This would include any additional Reinforcement provided for earthing requirement also.Note: (i) Cost is inclusive of 18 gauge GI binding wire (2 ply) in diamond form at each reinforcement junction.(ii) For pile reinforcement, welding of lap joint shall be without extra cost.(iii) Lap joints are permitted for bar dia. less than 16 mm (including 16mm), else mechanical couplers are to be provided, where in rebar ends shall be cold forged with die.(iv) The cost quoted should cover all welding and providing mechanical couplers, all types of laps, standard laps, spacer bar, Hooks, U-bar, chair, bend deduction as required and nothing extra is payable on this account. |
| 72 | Fabricating, providing and erecting in position of M S Ornamental security Grill Gate without hot dip using 75 X 12mm MS Flat for all- round frame work·with verticals at the center and horizontal centers support MS Square 20 X 20 mm of different heights as shown in the drawings to be fixed at 16 ems CIC for square bars of full height and at 8 ems CIC for bottom rods providing ornamental C I Designers at the bottom and C I arrows in the middle and top. The entire frame work is to be fixed by means of expansion bolts to the brick pillars with necessary drilling holes. the work includes providing two coats of enamel painting over one coat of red lead ready mix primer coat etc., complete cost of all labour, painting, erection charges using hoist pulley cranes with all lead and lift, loading, transporting and unloading using hoist pulley cranes, scaffolding. charges and all other incidental charges required for successful completion to the work as per specification. |
| 73 | Supplying and fixing M.S Rectangular poles made out of 2 equal angles of 65x65x6 mm welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm dia M.S. Hold fast rods each of length 25 cms.lncluding cost of all materials cutting, bending, scaffolding wherever necessary , nicely finishing the welded joints with all lead lifts and as per the directions of the Engineer and including providing 2 coats of approved quality paint over one coat of shop painting (excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications. |
| 74 | Providing and fixing of punched tape concertina coils of 600mm diameter over the boundary wall with \\"J\\" and \\"U\\" clips etc., complete as per manufactures specifications (Each coil to spread to 5.4 meter) including all needed barbed tapes I barbed wires for completing the work. |
| 75 | Providing and fixing M.S Block pipe of 38mm dia, of heavy gauge of 14 including removal of bends, cutting the pipe and fixing pipe in between the existing two vertical poles (M.S rectangular poles) and spot welding the chain link with M.S block pipe including cost of all materials wastage in cutting, and scaffolding wherever necessary with all lead and lift as directed by the Engineer complete including two coats of approved quality paint over one coat of shop paint, including cost of materials, labour, HOM complete as per specifications. |
| 76 | Providing and fixing pull and push type rolling shutters of approved make out of 18 gauge 75 mm wide cold rolled steel laths of convex corrugations, with side guides and bottom rails ,with interlocking arrangements for still laths by means of alternate clips, suspension shaft with high tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels ,ball bearing arrangement for inside and outside locking with push and pull operations complete including pulling hooks 4 Nos, handles with all fittings and accessories, painted with a coat of red lead paint (without top cover). Rate includes cost of all materials, labour, hire charges of machineries, with all leads & lift at all levels complete as per specifications & drawings.Note: In case of Rolling Shutter- cum -Grill. where the area of the grill portion is half or less than half the area of opening, it shall be measured and paid as rolling shutter and where the area of grill portion is more than half the area of openinq, it shall be measured and paid as rollinq |
| 77 | Extra for providing and fixing top covers made out of 20 gauge MS sheet over pull and push rolling shutters bent to shape including the cost of red lead primer, coat of painting materials, labour, Hire charges of machinery complete as per specifications |
| 78 | Extra for providing mechanical device chain and crank operation for operating rolling shutters or for electrical devices |
| 79 | Extra for providing grills in the rolling shutters manufactured out of 8mm dia. MS bar instead of laths as per design approved by Engineer. Note: only where the area of the grill portion is more than half the area of opening it shall be measured. |
| 80 | Structural steel work: Providing, fabricating structural steel to required profile and I MT shape, transporting, erecting and fixing in position at all levels of steel work Such as staircases of Overhead tanks, UG tanks and Pump rooms and Inspection chamber frames, chequered plate covers, edge angles, Cable Trench, gratings, frames, guard bar, ladder, railings, brackets, gates and similar works structural steel conforming to 'IS 2062 Grade E350 A' including procurement & testing of all raw steel materials, HSFG bolts, nuts (Confirming to IS 3757:1985 (Reaffirmed:2008) &1S 4000:1992 (Code of practice for high strength bolts in steel structures) & washer, fasteners, fabrication, joining, welding (confirming to IS: 816:1969 and IS 9595:1996), threading, sleeves etc., including allowance for all types of wastage, straightening, cutting, bending of section wherever specified, drilling holes, bolting provision of necessary tools, testing etc. complete. The rate shall also be included required surface preparation (Sand Blasting) for application of Zinc Epilux or equivalent primers, and two coats of Poly siloxane paint as per specifications. The rate shall also include supplying and providing of detailed fabrication drawings based on the GFC drawings, required for all permanent and temporary structures and their approval from Engineer, prior to execution. The rate shall also include provision and installation of base plate, anchor bolts (measured in tonnes) etc. all as per relevant drawings, specifications and directions of engineer using standard plate sections, rolled sections, like angles, channels, I sections, T sections, C sections, H sections and Light gauge steel sections confirming to IS:811-1987 (Specification for cold formed light gauge structural steel sections},hollow square/rectangle sections (Confirming to IS:4923-1997 (reaffirmed 2009) Hollow steel sections for structural use-specification), hollow round sections confirming to IS 1161:2014 (Steel tubes for structural purposes -Specification) etc., welded and built with all leads & lift at all levels. Total of Schedule \\"D\\" 0.0 SOLADEVANHALLI DEPOT- SCHEDULE E***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. Sl.No Description of Item Unit Qty Rate (***Refer Note) Amount INR SCHEDULE E:AT GRADE PORTION (CONCRETE & STEEL WORKS) |
| 81 | Earth work excavation in Ordinary/hard soil for road work, minor drains, cable trench etc. Either mechanically or manually as per drawing and technical specification, Including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, back filling the excavation earth to the extent required and utilizing/transporting the remaining earth including all leads and lifts including cost of labour, materials and HOM etc., complete. |
| 82 | Construction of embankment with approved material Gravel/Murrum with all lifts & leads, transporting to site, spreading, grading to required slope and compacted in layers not exceeding 200mm to meet requirement of Table No. 300-2 complete as per specifications (including cost of earth, watering charges & compaction by vibratory roller to 95% of proctor's density and minimum CBR value 5%) MORTH Specification No. 305. |
| 83 | Construction of embankment with approved material deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300- 2 complete as per specifications. Which includes, watering charges & compaction by vibratory roller. |
| 84 | Mechanical manufacturing of blanketing material by using only hard and durable stone crushed in mechanical crusher to different gradations, wet mixing of the same in designed proportion in Pug mill or wet mix plant to have uniform gradation including all incidental transportation, laying over finished formation in uniform layer(s) with motor grader, compaction with suitable vibratory roller to specified density and finishing to correct profile, complete as per RDSO Specification No. RDSO/2020/GE: IRS-0004 with latest correction slips. Note: This item shall be used only when entire constituent of blanketing material is mechanically manufactured by crushing of hard and durable stone into desired gradation of designed proportion. |
| 85 | Providing & laying plain cement concrete M20/20 grade in open foundation, stepped foundation, combined footing, raft foundation, retaining walls, return walls, walls, U/G tank, culverts, below pile cap, drains, floorings, below grade slabs, tie beams, basements, levelling course or any other works as directed by the Engineer, etc., complete using granite/ trap/ basalt aggregates and clean sieved approved sand including mixing mechanically and required dosage of admixture In concrete for obtaining required workability and as per specifications, approved drawings, laid In layers not exceeding 15cms thick layers, as per drawing including cost of all material, form work/ shuttering, centering, scaffolding, dewatering during concreting.; vibrating, compacting, hire charges of machinery, all lead and lift, loading, unloading, transporting, stacking, curing, finishing the exposed faces etc., complete. |
| 86 | Providing & laying design mix M35/20 grade, reinforced cement concrete using Portland slag cement (Directly from manufacturer or blending of OPC + GGBS) for following concrete works: Pile cap, Open Foundation / stepped foundation / Raft /Plinth beam, Slabs, Column Heads, Stairs & Ramps , Walls etc. including excavation up to 4.0 m from lowest ground level through existing water bound macadam road / bituminous road / concrete road /soil/murrum/ hard rock /soft rock old structures below ground as encountered of all thicknesses, dismantling other structures, dead utilities, dewatering, pumping and bailing out water, strutting and shoring, formwork, backfilling in foundation with good earth/quarry dust/sand watering, compacting with a vibratory plate compactor complete as per specifications. The Cost shall also include cutting / chipping of pile up to cut off level or up to good concrete and built up of pile up to required level. The cost includes loading, unloading and disposal of surplus excavated material along with pile heads using covered trucks to contractor's dumping yard with all leads and lifts and as directed by the Engineer. The contractor has to ensure that during transportation, the carried material does not spill out. Reinforcement shall be paid separately under relevant item. Rate shall include cost of using required dosage of admixture in concrete for obtaining required workability as per approval of Engineer, curing of concrete 10% of the amount shall be withheld and amount shall be released after disposal of excavated material including pile heads at contractor's dumging yard. |
| 87 | Providing TMT-500/550O grade steel bar reinforcement (conforming to IS:1786,HYSD Fe 5000 grade) at all heights & depth including straightening bars, cutting, bending, hooking binding with approved quality 18gauge G.I binding wire, after placing in position tying, lapping and /or welding wherever required and anchoring to the adjoining members wherever necessary as per drawings (Laps , Hooks, spacer bars, standard bars, U-bars, chairs, bend deduction and Wastages shall not be measured and paid) including cost of all materials, bar bending charges, labour, lead & lifts etc., complete as per specifications and as directed including welding involved towards stray current protection effects as per the system approved by Engineer. This would include any additional Reinforcement provided for earthing requirement also.Note: (i) Cost is inclusive of 18 gauge GI binding wire (2 ply) in diamond form at each reinforcement junction.(ii) For pile reinforcement, welding of lap joint shall be without extra cost.(iii) Lap joints are permitted for bar dia. less than 16 mm (including 16mm), else mechanical couplers are to be provided, where in rebar ends shall be cold forged with die.(iv) The cost quoted should cover all welding and providing mechanical couplers, all types of laps, standard laps, spacer bar, Hooks, U-bar, chair, bend deduction as required and nothing extra is payable on this account. |
| 88 | Providing and laying of Filter media. with granular materials / stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MORTH Specifications to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provide over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition as per drawing and Technical Specifications including the· cost of materials, labour, HOM, watering, transportation, lead, lift, loading, unloading, etc., complete as per specifications. |
| 89 | Providing and fixing Weep Holes in Abutments, Wing walls and Return walls etc., of new bridges with 110mm dia UPVC pipe Type A ISI marked with all contractor's men, material, transportation, all taxes as per specifications and as directed by Engineer-in-Charge |
| 90 | Providing and constructing granite/trap/basalt size stone masonry in foundation with cement mortar 1:8 stone hammered dressed in courses not less than 200 mm high, bond stones 2m apart in each course. Rate includes cost of all materials, scaffolding, curing, labour, hire charges of machineries, with all leads & lift at all levels, complete as per drawings, specifications and direction by the Engineer. |
| 91 | Providing rough cement plastering 15mm thick in single coat with cement mortar 1:6 to brick/ AAC masonry/ concrete block masonry/ concrete works for base of dadoing works with sand of approved quality. Rate includes cost of all materials, curing, scaffolding, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 92 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin-charge. (Made of G.I. wire of dia 4 mm) |
| 93 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge |
| 94 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. |
| 95 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Total of Schedule \\"E\\" 0.0 SOLADEVANHALLI DEPOT- SCHEDULE F***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. SI.No. Description of Item Unit Qty Rate (***Refer Note) Amount INR SCHEDULE F: PRE ENGINEERED BUILDING (PEB) STEEL |
| 96 | Providing, fabricating, painting, transporting, erecting structural steel members in buildings and workshops as per specification and approved shop drawings . Work under this item would generally cover all structural steelwork in the Buildings, including but not being limited to columns, stanchions, beams, rafters, purlins, runners for cladding, gantry girders, brackets, hangers/ suspenders, I runner beams for under slung cranes, bracings, etc. Work to include all intermediate stages of activities not defined herein, but otherwise implied for total completion of work. Cost to include but not be limited to, all materials including wastage, all consumables, fasteners of all types for both temporary and permanent stages of work, all temporary stays, labour, temporary works including staging, scaffolding, tools, plant and equipment, and, costs of all incidentals and necessary testing of material, workmanship etc including cost of painting as per specifications with all leads & lift at all levels.NOTE:1. Measurement will be on actual weight basis2. Rate includes cost of providing, fabricating and supplying Hot - Dip Galvanized Holding Down Bolts including all assemblies and accessories that are required to be embedded in concrete work. Bolts shall be of sufficient length to ensure that a minimum 40mm length of threaded portion is embedded in concrete. Threaded portion to be left projecting outside the concrete surface shall be as per approved drawing. Cost of fabricated, assembled and supplied Bolts shall include all necessary expenses incurred , including costs of all washers, nuts, lock nuts and pins that may be required for securing the structural member with the embedded bolts. Work of actual fastening of the structural components with the embedded bolts shall have to be carried out by the supplier of the steel structure. |
| 97 | Designing, Providing, fabricating and erecting hot dipped galvanised \\"Rain Water I Gutters\\" using 3.15 mm thick mild sheets including all accessories, connections sleeves for connecting rain water pipes to Gutters placed at roof along all valleys and edges of Buildings including site seal welding at all joints to make water tight including painting with all leads & lift at all levels as per drawing and technical specifications. |
| 98 | Providing and fixing single standing seam (Crimp curved) profiled sheeting 1000-1020 mm cover width, 28-30 mm crests @200-250 mm c/c manufactured out of 0.50 mm TCT (Total coated thickness) Hi- tensile galvalume steel. The sheets shall have wide pans with 2- 3 nos. stiffening ribs for effective water shedding and special male/female ends with full return legs on side laps for purlins support and anti- capillary flute in side lap. The sheets shall have clamp rail roof fastening with the provision for fixing solar panels, clamp rail is fastened to standing seam metal roofs via clamp without roof penetration (No damages shall be done to the roof or puncturing of roof sheets shall not be allowed). The sheets shall have a hot-dip metallic coating of ZINC and Aluminum (150 gms/sqm. zinc/alum. Coating mass total on both sides. AZ-150 as per AS 1397), 330Mpa to 550 Mpa yield stress, providing PVDF coating of approved colour of total thickness of 35 microns comprising of 20 microns exterior coat of PVDF over 5 microns PU back coat over 5 micron primer coats on both surfaces including side and end laps and using 8mm galvalume hex self-drilling. Item to include curved sheets and crimping also. Rate shall include providing fasteners on each crest of sheets for connection with purlins and seam all types of nuts and bolts as required etc. measured per unit of laid areas. |
| 99 | Providing and fixing single skin sheeting in cladding using Trapezoidal profiled sheeting of approved make, 730 -1020mm cover width 28- 32 mm crests depth at 186-250 c/c ( Above 200 c/c crest distance there will be minimum 2 ribs at the center for stiffening). The feed material is manufactured out of 0.45 mm BMT (Base Metal thickness) Hi- Tensile steel with min. 550Mpa yield strength coated with hot dip metallic zinc-aluminum alloy coating Zincalume AZ-150 or equivalent (as per AS1397) as 150 gms/sq.mt total on both sides of Zinc ( 45 %) & Aluminum (55%), with super polyester XRW quality paint coat as per AS/NZS-2728 (category 3) of approved colour.The colour shall have a total coating thickness of 35 microns of an super polyester XRW quality paint system as per AS/NZS-2728 (category 3), comprising of 20 microns exterior coat on top surface and 5 micron reverse coat on back surface over 5 micron primer coat on both surfaces. The Steel manufacturers test certificate for the chemical and mechanical properties of steel must be submitted for approval prior to installation. The sheet shall have brand marking of the manufacturer on the back of the sheet at every 1 mt c/c for conforming genuinity of the material. The steel sheet shall be fastened using Class 3 (as per AS3566) of size as per design, galvanized hex self-drilling fasteners of approved make and quality including EPDM/neoprene washer on each crest of sheets for connecting with purlins (or as per design). The contractor is to submit design and workshop drawings and take approval on the sheet profile, design and detail before installation of the sheets from the Engineer-in-charge. The measurement shall be based on per unit of finished/covered surface area. |
| 100 | Supply and Installation of polycarbonate multi-layered I multicell standing seam system, a complete assembly of coextruded UV protected polycarbonate panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 14 mm thick & of 900 mm width with angular daylighting concept. Panels shall have minimum six layers with angular walls in a truss type design for better strength & design flexibility including all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. The entire assembly shall be fixed on Purlin with snap on aluminium connectors with grip lock locking mechanism and will be secured on C Channel / Z purlin (will be paid Separately) with a continuous aluminium I Beam holding the base of the standing seam along the length of the panel & fixed with purlin with self-drilling hex head screws offering best stability with a pull-out load of min. 21000N (21KN) tested as per ISO 6892:1998 and IS 1608: 2005. The Connector to lock the panels shall be Extruded Aluminium with grip lock mechanism. The Aluminium I beam & the Aluminium Connector shall be factory bent to the desired radius to accommodate the panels. Panels must satisfy Dart drop impact test as per IS 14443- 97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall not be more than 2.3 W/m2K as per EN ISO 10077-2:2018. Panel shall be closed at the end with additional Aluminium F profile with a slot to accommodate EPDM Gasket to arrest flow of Rain Water ingress/ Glazing Bar for ends as required. Supply & installation of the system shall be carried out by the manufacturer only. Any installation by third party service provider is not acceptable to maintain better performance & long life of the entire assembly. |
| 101 | Providing, installing and fixing in position galvanized holding Down bolts of various sizes and lengths, as per drawings and instructions, including making of Pockets in foundations, column heads, beams etc with all leads & lift at all levels with bolts as per drawing and technical specification.(Cost also includes provision of templates ) |
| 102 | Providing, fabricating, installing and fixing in position Structural steel inserts, corner protection angles with lug-bars etc complete as per drawings, to be embedded in concrete with all leads & lift at all levels. Total of Schedule \\"F\\" 0.0 SOLADEVANHALLI DEPOT- SCHEDULE G***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. SI.No. Description of Item Unit Qty Rate (***Refer Note) Amount INR SCHEDULE G : ARCHITECTURAL WORKS |
| 103 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits, with chloropyriphos emulsifiable concentrates of 20% concentration at 3.19 Litre/sqm., including cost of chemical, diluting in water to one percent concentration, labour, HOM complete as per specifications. (Plinth area of the building at ground floor only shall be measured) MASONRY WORKS 0.0 |
| 104 | Providing and constructing load bearing wall with solid concrete blocks with 400 x 200 x 200mm size having block density not less than 1800 Kg/m3 having a minimum compressive strength of 5 N/sqmm. confirming to IS2185 (Part-1):2005 with cement mortar 1:4 as per IS 2572-2005.Rate includes cost of all materials, scaffolding, curing, labour, hire charges of machineries, with all leads & lift at all levels, complete as per drawings, specifications and direction by the Engineer. |
| 105 | Providing and constructing load bearing wall with solid concrete blocks with 400 x 200 x 100mm size having block density not ss than 1800 Kg/m3 having a minimum compressive strength of 5 N/sqmm. confirming to IS2185 (Part-1):2005 with cement mortar 1:4 as per IS 2572-2005.Rate includes cost of all materials, scaffolding, curing, labour, hire charges of machineries, with all leads & lift at all levels, complete as per drawings, specifications and direction by the Engineer. METALWORKS 0.0 0.0 |
| 106 | Providing and fixing of Single/ Double Leaf GI Door of approved make at all levels, formed by 1.6 mm galvanized steel for the Frame with holdfasts provided for grouting and installation. The Shutter shall have overall thickness of 46 mm, framed out of two outer skin panels of 0.9 mm galvanized Iron sheets and infill material of honey comb craft core, including having lock seam joints for locking, with reinforcements provided at locking/ hardware area including painting with approved make along with primer. The sheet metal used for both the frames and shutters shall conform to IS 277:1992 all complete as per vendor shop drawings, specification with all leads & lift at all levels and direction by the Engineer. |
| 107 | Providing fabricating assembling and fixing in position Aluminium doors and full height fixed glazing using following Aluminium mat finish or glassy finish, outer frame plain section 101.6 x 44.45 mm thickness 3.18 mm section weight 2.404 kg/m door shutters vertical sections 44.62 x 44.45 thickness 3 mm section weight 1.429 kg/m bottom section 114.3 x 44.45 mm thickness 3.18 mm section weight 2.648 kg/m door central section 49.9 x 44.45 mm thickness 3.00 mm section weight 1.495 kg/m glazing clips 19 x 17.3 x 11 mm thickness 0.9mm section weight 0.124 kg/m aluminium section cut to length joint metered corners grinded , the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closer, floor mounted, providing and fixing standard approved accessories , such as aluminium handle for full width or length, tower bolts, lock pivots, PVC or gasket with 5.5 .r:rirn thick glass for top and bottom panel 12 mm thick pre laminated particle board of approved colour both sides of exterior grade, aluminium sections treated for removal of any rust and prevention of further rusting formation ·and coated with grassy material for non- adherence of mortars or any other sticky materials the assembled frame fitted with corner angles, strips, gaskets and fitted with screws raw plugs or teak wood gut ties to RCC columns or masonry on sides, beams and flooring in bottom including cutting chiselling and making good with cement mortar to match the surface all the frames thoroughly cleaned free from rust scale or rust including cost of materials, fixtures, labours and HOM of machinery, with all leads & lift at all levels complete as per specifications. Using aluminium section powder coated to a minimum of 60-70 microns with exterior durable grade powder of approved quality. |
| 108 | Providing and fixing in position Aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame of size 61.85 x 31.75 mm with 1.2 mm thick bottom section weight 0.695 kg/m, sides and top sections 1.3 mm thick weight 0.659 kg/m and shutter comprising of top and bottom section of size 40 mm x 18 mm 1.25 mm thick, 0.417 kg/m shutter outer side 40 mm x 18 mm x 1.25 mm thick weight 0.417kg/m shutter interlock section of 40mm x 26.7 mm x 1.1mm thick weigh 0.469 kg/m the shutter mounted on nylon rollers with approved quality of fixtures such as aluminium handles, tower bolts etc. and providing and fixing 5.5 mm thick plain glass for shutters with rubber beading aluminium sections including cutting to required length, joints metered subdividing the frame tanonned and riveted in the assembled frame stiffened with and clips at corner anglesetc. and fixed to the walls, lintels, floor beams/sills as the case may be with necessary screws,·rawl plugs or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar. Using Aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality with all leads & lifts at all levels. |
| 109 | Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using three track window frame of size 92x31.75mm bottom section 1.3mm thick, weight 1.07kg/m; sides and top sections 1.3 mm, thick, weight 0.933kg/shutter frame section comprising top and bottom section of size 40mmx18mm, wall thickness 1.25mm. weight 0.417 kg.Im. shutter side outer 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall thickness 1.1 mm. thick, weight 0.469 kg/m, the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading all aluminium sections including cutting to required length, joints mitred subdividing the frame tanonned and rivetted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be, with necessary steel screws, raul plugs or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar. Using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. |
| 110 | Providing and fixing Extruded aluminium works for louvers and fixed glazing with extruded built up sections of size 61.85 x 31.75 mm with 1.2 mm thick bottom section weight 0.695 kg/m, sides and top sections 1.3 mm thick weight 0.659 kg/m and providing and fixing 5.5 mm thick plain glass with rubber beading aluminium sections of approved make, fixed with rawl pugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gaps at junctions at top, bottom and sides with required PVC/Neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing I panelling, CP brass/stainless steel screws, stainless steel hinges all complete as per drawings, specifications and the directions by the engineer with all lead & lift at all levels. Using Aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. |
| 111 | Providing and fixing aluminium casement windows, combination of fixed and openable glazing at top fully openable windows using z sections of 33mm, web thickness 4mm, weight 0.663kg/m; central mullion section 59x33mm with web thickness 3mm section weight 1.123kg/m; the shutters on aluminium hinges with approved quality of fixture such as aluminium tower bolts, handles, stage etc., providing and fixing 5.5mm plain glass for shutters fixed with glazed clips 19mmx17.3mmx11mm, 0.9mm thick and rubber beading aluminium sections cutting to required length, joints metered, sub dividing frame tenoned and riveted, assembled frame to be stiffened with end clips at corner , angles and fixed to wall, lintel beam , floor, sill as the case may be with necessary screws, rawl plugs, cutting masonry or concrete and making good the original surface,; aluminium surface pretreated for removal of any rust and coated with greasy materials for non adherence of mortar or any other sticky materials; (Coating removed after installation) and thoroughly cleaned free from dirt, rust etc., including cost of all materials, fixetures,labour and HOM complete as per specifications. Using aluminum section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. |
| 112 | Providing, fabricating, assembling and fixing In position aluminium partitions using aluminium sections of matt finish or glassy finish in combination of plain grove, single grove and double grove as per requirements for the frames of overall size 63.5mm x 38.1mm with thickness of 2mm,. having section weight, plain sections 1.054 kg/m,, single grove thickness 1.95mm,section weight 1.094 kg/m, double grove thickness 1.9mm section weight 1.094 kg/m and bottom member 114.3 mm x 44.45 mm thickness 3.18mm, weight 2.646 kg/m; aluminium louvers section of size 36.5mm x 34.93 mm 1.45mm thick, section weight 0.429 kg/m; bottom portions provided . with 12 mm thick pre-laminated sheet both sides of approved colour lamination exterior grade up to 0.9m height, spacing of vertical member not exceeding 0.6m clc; sections are cut to required lengths, joints mitered and corners grinded sub dividing frames tennoned and riveted to the frames the assembled frame stiffened with corner angles, stripped and fixed with screws, rawl plugs and teak wood, gutties to RCC columns on sides, RCC lintels or beams at top and floor at bottom, including cutting, chiseling and making good with cement mortar to match the surface; providing and fixing5.5 mm thick plain glass for middle portion viz., 0,9m to 2.13m and top panel with louvers sections; the glass and panels fitted with glazing clips of 19mm x 17.3mm of thickness 0.9mm, weight 0.124 kg/m, aluminium sections treated for removal of any rust and prevention of further rust formation, coated with greasy materials for non- adherence of mortars or any othersticky materials; vertical members embedded In the flooring by making suitable sized holes and fixing with cement mortar, with necessary opening for fixing of door of standard size (excluding cost of door) all the frames thoroughly cleaned, ,free from rust scale or dirt including of cost of materials, fixtures, labour, hire charges of machinery, with all leads & lift at all levels complete as per specifications.Using aluminum section powdered coated to a minimum of 60-70 microns with exterior durablepure polyester grade powder of approved quality. |
| 113 | Providing, fabricating, assembling and fixing in position aluminium shutters to a existing frame in the partition using 47.62mm x 44.45mm section thickness 3.18mm, weight 1.505 kg/m for vertical frame, 47.62mm x 44.45mm thickness of 3mm, weight 1.42 kg/m for top section, 49.91mm x 44.45mm with wall thickness 3mm, weight 1.495 kg/m for central rail; and 114.3mm x 44.45mm thickness 3.18mm, weight 2.646 kg/m for bottom rail; aluminium sections and cut to length joint metered and corners grinded, the bottom rail and top rail hinged or pivoted, opening arrangements including providing and fixing standard approved accessories, such as aluminium handles, tower bolts, lock, pivots: hinges PVC or rubber gasket, 12mm pre-laminated sheets (Novopan) exterior grade of approved colour both sides same colour for bottom panel of maximum height 0.90m and 5.5 mm thick plain glass for top panel (Novopan) and glass fixed with glazed clips 19mm x 17.3mm x 11mm, 0.9mm thick, weight0.124 kg/m; aluminium sections treated for removal of any rust and prevention of further rust formation, coated with greasy materials for non-adherence of mortars or any other sticky materials, including cost of materials, fixtures, labour and HOM of machinery, with all leads & lift at all levels complete as per specifications. Using aluminium section powered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality. |
| 114 | Providing and fixing of anodized aluminium louvers frames with aluminium outer frame and other necessary accessories complete as per architectural drawings , specifications and the directions of engineer in charge. |
| 115 | Hydraulic door closers - Providing and fixing hydraulic door closers of approved make with mounting heavy duty including cost of materials, labour, HOM, with all leads & lift at all levels complete as per specifications. |
| 116 | Providing and fixing combi pack with ultra mortise lock (200mm), ultra pin cylinder of (1Ck) I (2C) latch Set, complete with door strike, lever or knob handles, screws. etc. complete in stainless steel, for use on panelled/solid and glazed doors etc. including all fixings and other accessories as required and as per drawings, with all leads & lift at all levels specifications and as directed complete. |
| 117 | Providing and fixing double action hydraulic floor spring with brass cover plate minimum 1.25 mm thickness of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 118 | Providing and fixing of Hollow metal fire door at all levels from ISO 9001-2000 certified Manufacturer (2 hours). 3 criteria Fire rated door, fabricated and successfully tested at CBRI, in both directions (outside and inside opening) satisfying the three performance criteria of stability, integrity and insulation as per BS 476 Part 22 and IS:3614 Part II. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for maximum rating of (2 hours) and shall pass both UL1OB and UL10C. Pressed Galvanized Steel Single /Double leaf of required rating or approved equivalent which consists of frame, shutter. infill and finish as detailed below. Doors shall be supplied with appropriate labels confirming the rating. Door frame shall be double rebate profile of size 143 x 57mm made out of 16gauge thick galvanized steel sheet. Frames shall be Mitered and field assembled with self-tabs. All provision should be mortised, drilled and tapped for receiving appropriate ANSI/ UL labelled hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening including all leads & lift at all levels. |
| 119 | All doors and frames shall be finished with primer coating, stove zinc phosphate primer and thermoSetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test vision Panel- Providing 250 x 150 mm panels with 6 mm thick 2-hour fire rated heat resistant glass of borosilicate float glass with 5mm ceramic fiber tapes. Note: Hardware Sets shall be paid separately under relevant BOQ item. |
| 120 | Providing and fixing stainless steel hinges 125 x 90 x 4 mm long of approved make for fire rated doors complete as per specification and direction by the Engineer. |
| 121 | Providing and fixing mortise dead bolt (ML 1000) with side key operation cylinder of approved make for fire rated doors as per specification, drawing and direction by the Engineer. |
| 122 | Providing and fixing mortise sash lock (ML 1OOA) with Stainless steel lever handles of approved makes for fire rated doors as per specification and direction by the Engineer. |
| 123 | Providing and fixing 300 mm long concealed flush bolts· of approved make for fire rated door as per specification and direction by the Engineer. |
| 124 | Providing and Fixing 300 mm long Stainless steel Matt Finish 'D' handle (1 pair) of approved make as per specification and direction by the Engineer. |
| 125 | Providing and Fixing panic bar as per tech specification for single or double leaf doors of approved make as per specification and direction by the Engineer. |
| 126 | Providing and fixing 580 mm long concealed flush bolts of approved make for fire rated door as per specification and direction by the Engineer. |
| 127 | Providing and fabricating structural glazing semi unitized system of approved make as per design, drawings and specifications using aluminium extrusions 63.5mm x 58.00mm x 2.25mm of 1.73 Kgs/m for vertical and horizontal members and 63.5mm x 38.1 mm x1.33mm of 0.759 Kgs/m as outer Frame, powder coating to specified thickness in approved shade of approved make. Using 12.76 mm (6mm +0.76pvb + 6mm) thick PVB laminated soft coated performance glass (heat strengthened on the outer reflective surface) of approved colour and shade with all necessary accessories like ultra-glass silicon sealant of space tape, masking tape, galvanised anchor bolts, machine screws. Rate includes M.S. galvanised L brackets, structural sealant Setting clocks., fasteners, wall connection etc., complete. The structural glazing is to be fabricated as per drawings with partly fixed, partly openable and partly with aluminium louvers all as per the detailed drawings. The openable window shutters portion shall be fabricated with aluminium sections and powder coated to suit the other sections. The openable portion shall be provided with necessary heavy duty stainless steel stag and locking arrangements with necessary hinges. The aluminium louvers are to be provided wherever shown as per the drawings. All the works should be completed as a whole item of work for all heights including all lead, lift, scaffolding etc., complete. However, nothing extra shall be payable to the contractors for using larger/ heavier section than those given if found inadequate as per specifications and drawings. Note: Steel structural work required for structural glazing work which is in the scope of Contractor and Payment will be made at relevant BOO item. |
| 128 | Providing and Applying polysulfide (Note width to depth ratio- 2:1) sealant with backer rod to the floor or wall expansion joint of width 20mm as per the direction of engineer. Rate includes cost of all materials, scaffolding, labour, hire charges of machineries, with all leads & lift at all levels complete as per specifications & drawings. |
| 129 | Providing and fixing 100 mm wide 3mm thick 304 grade stainless steel plate fixed over expansion joints screwed to floor or wall with CSK screws and rawl plugs through slotted holes on one edge and round holes on other edge (screw on both edges@ 600 c/c).Screws shall be staggered on either ends all complete as per detail. Rate includes cost of all materials, labour, hire charges ofmachineries, with all leads & lift at all levels complete as per specifications & drawings. |
| 130 | Providing and fixing 65mmx125mm GRP Door frame fabricated using E-Glass Chopped Strand Mat (CSM) U.V- stabilized lsopthalic Gelcoat and lsopthalic resin. The thickness of the GRP skin shall not be less than 2.0mm. The door frame consists of four segments, which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screws. The GRP frame shall be provided with wooden reinforcement on 6 locations for high screw holding capacity for fixing metalling hold fast and shall be consolidated by filling with medium density foam/Plaster of Paris with fibre reinforcement. Six Numbers of 260mmx25mmx5mm size S shaped M.S. flat hold fast shall be provided with the frame. |
| 131 | Providing and fixing factory made single left rigid GRP Sandwich composite door shutter of 32mm thick, laminated with two GRP skins with wood grain finish, fabricated using UV-stabilized lsopthalic Gelcoat and on layer of 45 gsm E-Glass Chopped strand Mat (CSM), impregnated with orthopthalic polyster resin. The thickness of the skins shall not be less than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm thickness and a density of 20 Kg/m3 shall be used as core material. Wooden reinforcements made of Seasoned Salwood block of cross section not less than 28mmx32mm and also necessary salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be provided. A structural adhesive compatible with EPS foam shall be used for bonding the core material, the Salwood reinforcement and the skins. The material and process for manufacturing the door shutters shall confirm to RV/TIFAC Composites Design centre Standards and specifications and the door shutters tested in confiramation to IS 4020-1994. The finish of shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour using high quality pigments. Excluding cost of fixtures and inclusive of supply of shutters to respective work spot. |
| 132 | Providing & Fixing Mosquito mesh shutters made out of Stainless Steel mosquito proof mesh with 95% & above visibility which is fixed to the powder coated aluminium frame 32mm thick of approved shade. The work including fixing the shutters with necessary accessories, to complete as per specification including the labour charges for fixing the shutter to the existing frames. FLOORING WORKS 0.0 |
| 133 | Providing wall cladding, skirting, dadoing, risers of steps with coloured glazed tiles/ceramic glazed tiles in 10 mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using coloured glazed tiles of approved make and size. 6 mm thick Rate includes cost of all materials, curing, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. Also Providing and fixing in position PVC BEADING of Dural make/ Eq. for corners, colour of the beading to match the shade of the Tile. |
| 134 | Providing and laying 1:2:4 cement concrete flooring, 60 mm thick with metallic concrete hardener toping, under layer of 45mm thick 1:2:4 cement concrete using broken granite metal of 20mm and down size, and top layer 15 mm thick of metallic cement hardener consisting of mix 1:2 (1 cement hardener mix, 2 granite metal 10 mm nominal, size) by volume with metallic hardening compound of approved quality mix in the ratio of 4:1 (4 part of cement = 1 part of metallic floor hardening compound of approved quality by wt.), including finishing, cost of materials, labour, curing, with all leads& lift at all levels complete as per specifications. |
| 135 | Providing and laying 1:2:4 cement concrete flooring, 50 mm thick with hardcrete metallic concrete hardener toping,under layer of 35mm thick 1:2:4 cement concrete using broken granite metal of 20mm and down size, and top layer 15 mm thick of metallic cement hardener consisting of mix 1:2 (1 cement hardener mix, 2 granite metal 10 mm nominal, size) by volume with metallic hardening compound of approved quality mix in the ratio of 4:1 (4 part of cement = 1 part of metallic floor hardening compound of approved quality by wt.), including finishing, cost of materials, labour, curing, with all leads & lift at all levels complete as per specifications. |
| 136 | Providing and laying flamed/ Mirror Polished 25mm thick and minimum 1200mm long Sadarahalli granite for 300mm wide(approx.) tread including 60mm wide flamed strip (if required) in stairs &landings, making the required one side full/half nosing finishing and 2 Nos. 6x6 anti-slip grooves filled with carborandum powder mixed with Araldite or equal adhesives all to the required design details and pattern, approved colour, shade laid over base 30mm thick 1:4cement mortar fit jointed with/ without groove with white cement slurry mixed with pigment to match shade of granite. Rate includes, cost of all materials, curing, labour, hire charges of machineries, with all leads & lift at all levels completes per drawings, specifications and direction by the Engineer. |
| 137 | Providing and laying flamed finished 25mm thick and minimum 1200mm long Sadarahalli granite for floors to the required design details and pattern, approved colour, shade laid over base 30mm thick 1:4cement mortar, fit jointed with/ without groove with white cement slurry mixed with pigment to match shade of granite. Rate includes cost of all materials, curing, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 138 | Providing and laying Polished /hooned granite(Apple red/sadarahalli grey/pearl white/ Hassan green/ china pink/ all type of black/ ocean green/ lavender blue etc.)of 18mm thick(+ or - 1mm) of length not less than 1100mm and width not less than 800mm for floors to the required design details and pattern, approved colour, shade laid over base 25mm thick 1:4cement mortar with paper joint finished with white cement slurry mixed with pigment to match shade of granite. Laying of Plaster of Paris (POP) on finished surface (minimum thickness 10mm) and cleaning the surface by removing POP .Provisions made for cut-outs. Rate includes cost of all materials, curing, labour, hire charges of machineries, with all leads & lift at all levels, complete as per drawings, specificationsand direction by the Engineer. |
| 139 | Providing and laying polished Jet Black granite stones of 18mm thick( + or - 1mm) cut to required size, for skirting heights up to 150 300mm , risers, coping, wash basin counters making the required one side full/half nosing finishing all to the required design details and pattern, approved colour, shade laid over bed 18mm thick 1:4cement mortar (1cement : 4 Coarser sand) or with approved epoxy and tile adhesive as required at site and joints matching to floor joints with paper joint finished with white cement slurry mixed with pigment to match shade of granite. Rate includes cost of all materials, curing, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 140 | Providing and fixing wall cladding using 18 mm thick polished Jet Black granite gang saw water cut granite in CM 1:3 proportion cut to required shape making the required one side full/half nosing finishing all to the required design details and pattern, approved colour, shade with paper joint, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, including providing machine drilled holes ,recesses, rebates for stainless steel attachments/fixing providing movement joints etc., making the required \\"V\\" grooves in joints. Rate includes cost of all materials, curing, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 141 | Providing and fixing 20mm thick mirror polished granite (Apple red/sadarahalli grey/pearl white/ Hassan green/ china pink/ all type of black/ ocean green/ lavender blue etc.) for counters / fascias and other specified locations of required size making necessary edges molding mirror polishing to edge to give high gloss finishing, cutting the granite to required size, shape and making necessary holes / openings all to the required design details and pattern, approved colour, shade laid over 19mm thick water proof plywood with epoxy adhesive material. Rate includes cost of all materials, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer.Note: 1. Rate includes cost of fixing plywood with Steel frame2. Cost of Steel frame will be paid under relevant BOQ item |
| 142 | Providing and fixing Vitrified glazed tiles of approved make, quality and color of size 900x900x12mm thick with 3-4 mm thick PVC spacers and filling with epoxy grout contrasting colour of tile fixed on bed of 12mm thick cement mortar for flooring, skirting and jointed with neat cement slurry mixed with pigment to match shade of tiles, including providing spacers at required interval and removing stains, including cost of all materials, mortar, labour etc., complete as per specification and directed by engineer. |
| 143 | Providing & laying in position on floor, skirting and in bands, vitrified unglazed anti skid/Uni colour series floor tiles 300 x 300 x 7.3 mm thick of approved make, specification and approved colours laid over upto 30 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) to the pattern as called for including finishing the joints with matching pigment and approved grouting materials. Rate includes cost of all materials, curing, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 144 | Providing and fixing 10 mm thick acid and / or alkali resistant vitrified tiles of approved make and colour using acid and /or alkali resisting mortar bedding and joints filled with acid and / or alkali resisting cement as per IS:4457 complete as per the direction of Engineer. On a flooring on a bed up to 30mm thick mortar of 1:4 proportion. Rate includes cost of all materials, curing, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 145 | Providing and laying heavy duty interlock pavers of 75mm thick, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281kg/per sqm over 30mm .thick cement mortar CM(1:3) and impacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and HOM ofmachineries, with all leads & lift at all levels complete as per specifications. |
| 146 | Providing and fixing 450mm high cavity Unitile raised access flooring system or equivalent conforming to PSA MOB standard as per the following specifications. Unitile USF · 1500 access floor panel of size 600 X 600 mm shall be all steel weldedconstruction, with an enclosed bottom pan of 49 hemispherical and 36 reverse cones and top plain sheet which are fuse welded at 124 locations to form a panel of an overall depth of 35mm. The inner empty core of the panel is injected with alight weight for retardant non combustible cementitious compound at high pressure to fill in all the crevices of the panel and ensure support of not less than 85 % of the top surface area of the panel. The panel after cleaning, degreasing, phosphating by 7 tank process is coated with 40-60 micron epoxy coat and is heated to achieve maximum adhesion and surface resistance. The panel is then laminated with 1.5mm thick fire retardant floor grade antistatic laminate (Electrical Resistance shall be in the range of 1.0 X 10 X 6 ohms to 2.0 X 10 X 10 ohms) on a semi-automatic lamination line to ensure maximum bonding to the steel surface. The edges of the laminated are protected with a conductive PVC edge profile of the same range of the electrical resistivity as the laminate which is 5 mm wide on all sides. This edge trim is mechanically locked and sealed in place to avoid detachment. Other details as per technical specification and manufacturer's instructions including all necessary support systems like pedestals, base plates, stringers with necessaryfixing arrangements etc. complete with all leads & lift at all levels. |
| 147 | 3mm thick epoxy floor coating: Underlay of 2mm thick Providing and applying 2 part epoxy resin primer MasterTop 1620 [email protected] Kg/ Sqm of BASF over the prepared surface Providing and applying three part, self smoothing underlay screed Sikafloor 81 Epocem/ Myk Schemburg/ cempo 102 of myk Schemburg/ Pidilite/ Fosroc or approved equivalent to a thickness of 2mm@ approx. 4.5 kg/m2 having carbon dioxide diffusion coefficient 4168 as per Klopfer Engel fried method Water vapour diffusion co-efficient µH2O = 252 as per DIN 52615, Water absorption co-efficient W = 0.02 kg/m2as per DIN 52617. Providing and applying four part, self smoothing, solvent free, coloured, smooth glossy, epoxy resin screed Sikafloor®--261hs 1 mm @ 1.7 Kg / Sqm having compressive strength of 65 N/mm2 ASTM C 579, Flexural strength of 45N/mm2 as per DIN EN 196, tensile strength of 16N/mm2 as per ISO 527, Shore D Hardness 75 As per DIN 53 505, abrasion resistance 0.35mm as per IS 1237&IS9162-79. All in complete as per the manufacturers specifications and directions of the engineer. |
| 148 | Providing and laying cinder concrete in cement 1:15 (1 cement: 15 cinder of 12.5mm nominal gauge) on terraced roof or sunkenslabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. |
| 149 | Wall lining butch work upto 1Om height with Dholpur stone 40 mm thick rough facing on the exposed surface with stone strips of minimum length 300 mm and required width, including embedding every tenth layer and bottom most layer in masonry or concrete after making necessary chases of size 75x75 mm and by providing layer of 75 mm thick strips i/c 12 mm thick bed of cement mortar 1:3 (1 Cement : 3 coarse sand) i/c ruled pointing in cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture ofpigment to match the shade of stone complete as per direction of Engineer. FINISHING WORKS |
| 150 | Providing 12mm thick cement plaster in single coat with cement mortar 1:6 to brick / AAC masonry I concrete solid block masonry/ concrete works including rounding off corners wherever required smooth rendering. Rate includes cost of all materials, curing, labour, scaffolding, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 151 | Providing rough cement plastering 15mm thick in single coat with cement mortar 1:6 to brick/ AAC masonry/ concrete block masonry/ concrete works for base of dadoing works with sand of approved quality. Rate includes cost of all materials, curing, scaffolding, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 152 | Providing 12 mm thick cement plaster in single coat with cement mortar 1:3 to ceiling including rounding off corners wherever required smooth rendering. Rate includes cost of all materials, curing, scaffolding, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer |
| 153 | Providing 18 mm thick water proof cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge including rounding off corners wherever required smooth rendering; providing and removing scaffolding, including cost of materials, labour, curing complete as per specification for all heights in an even shade, cleaning the surface of all dirt, dust and foreign materials, sand preparing. Rate includes cost of all materials, curing, scaffolding, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 154 | Providing and fixing 200mm wide plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm, along route of walls chipped for services, junction between RCC and brick walls/ cement concrete walls. Rate includes cost of all materials, labour, scaffolding, hire charges of machinery, with all leads and lifts at all levels complete as per drawings, specifications and direction by the Engineer. |
| 155 | Providing and painting acrylic emulsion paint of approved make, colour and shade on new work (plaster, RCC, wood or metal etc.) in two coats to give an even shade I pattern, including primer, preparation of surface using two or more coats of wall putty, etc.Surface duly emery papered to give a perfectly smooth and even prepared surface before painting. Rate includes cost of all materials, scaffolding, labour, hire charges of machineries, scaffolding, will all lead and lift, at all levels complete as per specifications. |
| 156 | Providing and applying painting in two coats with Plastic emulsion paint and one coat with primer of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth. Rate includes cost of all materials, scaffolding, and labour, hire charges ofmachineries, scaffolding, with all leads & lift, at all levels complete as per specifications. |
| 157 | Providing and painting exterior walls/surfaces with exterior grade emulsion paint of approved make, colour and shade 2 Coats on new work {plaster, RCC, wood or metal etc.) Including preparing even/ smooth surface with sand paper and making good the surfaces to give a smooth and even prepared surface, preparation of surface using two or more coats of wall putty, etc. before painting. Rate includes cost of all materials, labour, scaffolding, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 158 | Providing external walls with texture finish using approved brand paint, applied uniformly in three coats over one coat of primer including cost of all materials, machineries, labour, transportation, loading & unloading, all leads & lifts and all other incidental charges including scaffolding and removing stains, complete as per specifications |
| 159 | Providing and finishing two coats with water proof cement paint of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign materials. Rate includes cost of all materials, scaffolding, curing, labour, hire charges of machineries, scaffolding, with all leads & lift, at all levels complete as per specifications. |
| 160 | Providing an applying synthetic enamel painting of approved brand, colour, and shade 2 coats in new surfaces (plaster, wood or metal) to give an even shade, cleaning the surface of all dirt, dust and foreign materials, sand papering and application of putty. Rate includes cost of all materials, scaffolding, labour, hire charges of machineries, with all leads & lift at all levels complete as per drawings, specifications and direction by the Engineer. |
| 161 | Providing and applying two coats with oil bound washable distemper of approved brand and shade on wall surface including priming coat with distemper primer after thoroughly brooming the surface free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth. Rate includes cost of all materials, scaffolding, labour, hire charges of machineries, scaffolding, with all leads & lift, at all levels complete as per specifications. |
| 162 | Providing and applying polishing with trench polish on new wood surface and I or wood based surface give an even surface after cleaning the surface of all, dirt, dust and foreign matter, sand papered smooth, including cost of wood filler and materials, labour, with all leads & lift at all levels complete as per specifications. |
| 163 | Providing and applying enamel metal paint two coats ( excluding priming coat ) over new steel or other metal surface brushing to give an even shade after cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, with all leads & lift at all levels complete as per specifications. |
| 164 | Supply and fixing of Flexalum metal tile ceiling system manufacture by M/s. Hunter Douglas India Pvt. Ltd or equivalent comprising of tile of 600mm wide and 600mm long manufactured of 0.7mm aluminium alloy 3105 perforated for desired openings and patterns giving a 22% open area. The tile will be manufactured on advanced equipment, which includes several levelling stages in the manufacturing process \\"Tiles ends will be raised with pips and stops to ensure positive engagements into the spring to enable for demounting of individual panels. The tile sides will be sufficiently high to ensure a minimum deflection across the length of tiles. The tiles will be bevel edged the tile shall be polyester based, powder coated in white colour. Tile shall be clipped to clip in profile of 0.5 mm thick G.I the clips in Profile shall be supported from slab by means of rigid suspension of 4mm G.I rod old on clamp with clip with all leads & lift at all levels. |
| 165 | Providing and fixing hand M.S tube rail of approved size by welding etc. to steel ladder railing , balcony railing ,staircase railing and similar work including applying priming coat of approved steel primer etc.complete as directed by engineer-in-charge |
| 166 | Fabricating, supplying and installing in position all types of Railing to spiral stairs and other stairs, terrace, parapets and other locations called for with Stainless Steel of SS grade - 316 consisting of tubes of various sizes like 100mm, 50mm, 40mm, 25mm, 20mm dia and such flats, solid, square, circular bars etc. arranged in verticals and horizontals with spacing as required and anchored to sides/ top of steps! slab , hand rail and all other stainless steel tubes (wall thickness minimum 1.25mm and maximum 2.0mm thick) fixed to stainless steel verticals through shaped SS plates! flats including approved brackets and fittings. anchoring arrangement, all fixing accessories, all cutting, welding, bending, grinding, drilling, tapping and all other incidental works and approved buffing to stainless steel members all leads and lifts, etc. complete as directed by Engineer. |
| 167 | Supply, delivery, storage & installation of Metal Automatic galvanised industrial motorized Rolling Shutter of approved make ie. lndo-germa Ltd., Chennai or equivalent made Doors assembly conforming to BS:476 Part II, IS:3614 Part II, complete with shutters, G.I Guides, Control box.drive unit, frames, hinges etc. Door shutter and frames to have all hardware preparations must be prepunctured at the factory for fixing of said hardware. Shutters & frames to be filled with suitable fillers, insulation to meet the required fire resistance criteria as specified, with all grouting, reinforcements, flushed lock seam joints including all seals, washers, linings etc. complete. All doors to be primered and painted with approved painting system as per tested prototype and to approved colour. Provision of mortise sash lock (ML 1ODA) with S.S. lever handles and door closers heavy duty (imported) LCN 1461 with standard arm on every leaf, stainless steel hinges as per approved shop drawing, etc. complete as directed by Engineer-in- charge. |
| 168 | Providing weep holes in brick masonry/plain/reinforced concrete abutment, wing wall, return wall with 100mm dia. AC pipe extending through the full width of the structure with slope of 1V:20H towards drawing force as per drawing and technical specifications including cost of all materials, labour, HOM, with all leads & lift at all levels complete as per specifications. (MORTH specification 2706 & 2200). |
| 169 | Supplying, pouring and packing non-shrink grout as per manufacture's specifications under base plates of columns, trusses etc. complete as per drawings and specifications, with all leads & lift at all levels including cost of packing plates. WATER PROOFING 0.0 |
| 170 | Providing waterproof treatment to roof slab using 2 coats of acrylic copolymer elastomeric ISOPROOF sealer and protector. The surface shall be prepared free of tar, dust, fungus, loose particles etc. The surface shall be applied with basecoat of crystallization liquid and the ISOPROOF, wetting agent and liquid (1:1:6) over the prepared surface. In addition the surface shall be provided with polysulphide/acrylic sealant to v groves, making haunch at junction at parapet and roof slab and at damaged portion using patching mortar to drain off rain water. Over this one coat of flexible cementatious membrane (FCM) spreading 2 layers of 40 gsm non woven geotextile membrane as reinforcing material (over FCM) with one primer coat of ISOPROOF & applying second coat of ISOPROOF liquid over the primer coat-conforming to ASTM D 412-1992. The work shall be carried out as per the directions of the engineer in charge. |
| 171 | FOR TOILETS SUNK PORTIONS Providing INTEGRAL CRYSTALINE Waterproofing treatment to the sunken portion of Toilets. Using Crystalline Slurry of approved make @ 1.4kg per SQM in two coats (0.7 kg per sqm per coat) conforming to ASTM C 1202 & DINV 18998 standards.1.Methodology: 1. The first part consisting of grouting the porous slab area with non-shrink cementatious grout (if required). 2. The second part consisting of treating the cracks and construction joints by routing-out to a minimum 20mm x 20mm groove and treatingit with crystalisation Mortar. First it is primed with crystalisation slurry and later filled with crystalisation mortar and later again a coat of crystalisatiori slurry. 3. The third part consisting of making required slopes at the interface joint of the toilet slab and masonry wall with crystalisation Mortar. 4. The fourth part consisting of sealing I packing all joints of outlet pipes, etc. with CRYSTALISATION MORTAR. 5. The fifth part consisting of providing and applying In-depth Crystalline Waterproofing System @ 1.4 kgs/sqm in 2 coats to permanently fix non-soluble crystalline growth throughout the capillary tracts and pores of concrete. The In-depth Crystalline waterproofing Material shall be applied by brushing as per manufacturer's specification on the entire toilet sunken slab andwalls. Sqm 1415.9750000000001 0.0 ADDITIONAL WORKS 0.0 |
| 172 | Drainage Spouts using 100mm class 'B' GI pipe as per drawing and Technical specification including clamps and nuts etc.,including cost of materials, labour, HOM complete as per specifications. MORTH Specification No. 2705 0.0 |
| 173 | Supply & fixing of 6 kg / Sq mm UPVC Rain water pipes including all fittings, bends supports, etc., with solvent cement joints. 150 mm dia Total of Schedule \\"G\\" 0.0 SOLADEVANHALLI DEPOT-SCHEDULE H***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. SI.No. Description of Item Unit Qty Rate (***Refer Note) Amount INR SCHEDULE H: PUBLIC HEALTH ENGINEERING (CIVIL) - |
| 174 | Providing and fixing 30mm thick phenol bonded water proof exterior grade flush door shutter of approved make, including sat wood frame of section 125mmx63mm fixed td wall opening in RCC/block masonry with necessary hold fast as per the directed by the engineer.Note:1. The door shall be provided with following item, i) 3nos 100mm long SS butt hinges in single leaf door /6no 100mm long SS butt hinges in double leaf door shutter. ii) 1 nos. mortise lock with handle @100mm. iii) 2 nos. 200mm long Aluminum tower bolt. iv) 1 nos 200mm long aluminum drop and handle in place of mortise lock if required. v) Painting with synthetic enamel paint, i/c wood primer of approved·brands and shades.2. The cost of the item is inclusive of all materials, accessories, hardware, labours, tools, plants & machineries, transportation,handling with all lead, lifts ,and working all level & heights. Finishes of all materials shall be got approved by the Engineer. |
| 175 | Providing and application of water proofing after filling the bore holes if any with non-shrink grout, shrinkkomp 20 or equivalent, and filling the cracks in brick work and concrete with polymer modified Cera latex SBR or equivalent mortar with proper coving at corners, and applying acrylic polymer based water proofing system Ceralistic or equivalent in two coats on cleared surface and then applying 20mm thick plaster with 1:4 cement mortar admixed with cera proof IWP liquid or equivalent and at a dosage of 200ml per bag of cement and testing the work by ponding the water.Note: The cost of the item is inclusive of all materials, accessories, labours, tools, plants & machineries, transportation, handlingwith all lead, lifts, and working at all levels & heights. |
| 176 | Providing and fixing white vitreous china clay, water cloSet European type (Pedestal type) with 'P' trap or 'S' trap with black solid plastic seat and lid, C.P brass hinges, rubber buffers (all are approved make) 10ltrs. white glazed / vitreous chain clay low level flushing cistern with fittings, C.I / M.S brackets, 40 mm diameter flush bend with fittings and clamps, overflow arrangements with special and 25 mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. |
| 177 | Providing and fixing white vitreous china clay, flat back, lipped front urinal basin of 430x260x350 mm in the range of two with C.I /M.S brackets, standard flush pipe and C.P brass spreaders with brass unions and G.I clamps painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. |
| 178 | Providing and fixing of required size and shape mirror with plastic moulded frame of approved make and shade with 6mm thick hard board backing including cost of labour complete as per specification. |
| 179 | Providing and fixing vitreous china toilet paper holder with mortar / white cement with all fittings and fastenings all complete as required. |
| 180 | Providing and fixing of bib cock with health faucet with flexible pipe of appropriate length with a separate stop cock for the health faucet. The cost to incl!Jde all fittings and fastenings all complete as required. |
| 181 | Providing and fixing wall mounting type push-type liquid soap dispenser with 1000 ml bulk volume, with pump suitable for operation on less than 5 PSI complete in all respects. The cost to include all fittings and fastenings all complete as required. |
| 182 | Supplying and fixing ABS soap 150ml dish near wash basins with necessary fixing materials etc. complete. |
| 183 | Providing and fixing of CP grab rail in People with Disability Toilet. The cost to include all fittings and fastenings all complete as required. |
| 184 | Providing and fixing Urinal Partition of 10mm thick of approved material as specified. The cost shall include all fittings and fastenings all complete as required. |
| 185 | Providing and fixing electronic sensors for flushing in urinals. auto flush system to urinal with infrared sensor, solenoid valve, gate valve, black box and necessary wiring in conduit from solenoid value to black box and to mains complete. (Battery Cum & Electrical operation) |
| 186 | Supply and fixing of white vitreous china oval counter bottom fixed wash basin of size 630 x 450mm, installed below granite counter (or as per Engineer approval) and brackets, 32mm dia CP waste coupling, 32mm dia CP brass bottle trap, 15mm dia CP angle stop cock for cold water supply lines with flanges, 375mm Long Copper connectors including nuts & washers and making connection to the mixtures etc,. The work shall include cutting and making good the walls and floors. |
| 187 | Providing and fixing automatically operated Hand Dryer within built Heating unit and twin Blowers of Standard make. |
| 188 | Supplying, fixing and testing PVC floor trap (multy trap-heavy duty hinged type) with brass CP frame and cover (150mm x 150mm) & cockroach floor trap with GI Trap of 100mm dia. Inlet and 50175mm dia outletfixed on a bed of cement concrete etc., complete. |
| 189 | Supplying, Installing, testing and commissioning approved make angular stop cock with necessary fixing materials etc., complete. 20 mm dia. (Screwed ends) |
| 190 | Supplying, installing and testing 15mm CP bib cock with CP flanges including necessary fixing materials etc., complete. |
| 191 | Supplying, installing and testing C.P. flush valve with C.P pipe, wall bracket, including necessary fixing materials etc., complete. |
| 192 | Supply, Installing, testing & commissioning sink with single bowl and single drain board manufactured from 1mm thick stainless steel, 18G high grade in destructible chrome nickel steel with top quality polish,1no.40mmdia CP waste coupling ,with 1no. 40mm dia CP bottle trap with extension pipe, 15mm dia CP sink cock with swivel spout wall mounted type and necessary wall flanges etc., complete. Size of sink : 1000mm x 500mm of approved make as per specification |
| 193 | Installing, testing and commissioning of approved vertical / horizontal type 25 Ltrs Electric water heater with heating element with thermostat ,2 Nos. 15mm dia CP angle valve, pressure relief valve, non-return valve with CP copper connecting pipes with wall flanges of approved make etc., complete make as per specification. |
| 194 | Supplying, Installing, testing and commissioning of 0.6 LPM drinking water Reverse osmosis plant with pre filter, sediment filter, pre carbon filter cum adsorber RO membrane, UV disinfection column, UF cartridge and material of construction should be food grade. Including of 40L SS/food grade storage tank with cooler & two outlet tap. WATER SUPPLY WORKS & PUMPS 0.0 0.0 |
| 195 | Providing and fixing CPVC pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1.00 mt spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and testing of joints complete (internal works exposed on wall) with all leads & lift at all levels. |
| 196 | 20mm dia |
| 197 | 25mm dia |
| 198 | 32mm dia |
| 199 | 40mm dia |
| 200 | 50mm dia |
| 201 | Providing and fixing CPVC pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fitting with one step CPVC solvent cement, trenching, refilling and testing of joints complete (external works) with all leads & lift at all levels. |
| 202 | 25mm dia |
| 203 | 32mm dia |
| 204 | 40mm dia |
| 205 | 50mm dia |
| 206 | 65mm dia |
| 207 | 80mm dia |
| 208 | 100mm dia |
| 209 | Fixing of 100mm water meter with stop cock, jam nut, socket in GI pipe line including cutting and threading the pipe and making longscrew including cost of materials, labour, with all leads & lift at all levels HOM of equipment and testing complete as per specifications. |
| 210 | Making connection of CPVC distribution branch with CPVC main of 25 to 40mm, nominal bore, including cutting and threading the pipes, providing and fixing tee, nuts, labour with all leads & lift at all levels for all item of works, testing and HOM of equipment complete as per specifications |
| 211 | Providing and fixing in position brass stop cock of approved quality nominal bore including cost of materials, labour, HOM of equipment with all lead and lifts complete as per specifications |
| 212 | 25mm dia |
| 213 | 32mm dia |
| 214 | Providing and fixing in position brass bib cock of approved quality of 15 mm nominal bore including cost of materials. labour, HOM of equipment with all lead and lifts complete as per specifications |
| 215 | Providing and fixing in position brass gate valve with Cl wheel of approve quality (screwed end) required size of nominal bore including cost of materials, labour and HOM of equipment with all leads & lifts complete as per specification. |
| 216 | 20mm dia |
| 217 | 25mm dia |
| 218 | 32mm dia |
| 219 | 40mm dia |
| 220 | 50mm dia |
| 221 | 65mm dia |
| 222 | Providing and fixing unplasticised PVC connection pipe with brass union 15mm nominal bore 450mm length of PVC connection including cost of all materials, labour and HOM of equipment with all leads & lifts complete as Per specifications. |
| 223 | Providing and fixing in position nominal bore non-return valve Vertical type of approved make including cost of all materials, labour and HOM of equipment with all leads & lifts complete as per specifications |
| 224 | 20mm dia |
| 225 | 25mm dia |
| 226 | 32mm dia |
| 227 | 40mm dia |
| 228 | 50mm dia |
| 229 | 65mm dia |
| 230 | Providing and placing on terrace, polyethylene storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable dia. meter for Inlet, outlet and overflow pipes, including cost of materials, labours, transport charges, with all leads & lift at all levels HOM of equipment and testing complete as per specifications(capacity of tanks for different buildings will be as per requirement at site} (For 1000 litre Capacity). |
| 231 | Constructing brick masonry inspection chamber 500 x 700mm, and 450mm depth for water supply valve chamber, (clear Inside dimension) for pipeline with one or two inlets, using table mounted non-modular bricks of class designation 50 in cement mortar 1:5, Cl cover with frame (light duty) 450 x 610mm internal dimensions, total weight of cover 23 kg and weight of frame 15 kg). RCC top slab with cement concrete 1:2:4 mix 20mm and downsize granite metal, foundation concrete 1:5:10 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finished smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing, with all leads & lift at all levels complete as per specifications. |
| 232 | Providing and fixing Y-strainer of the following nominal dia. Conforming to IS specifications as per direction including all leadall and lift charges etc., complete |
| 233 | 32mm dia |
| 234 | 40mm dia |
| 235 | Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 20 mm nominal bore including cost of materials, labour and HOM of equipment with all leads & lifts complete as per specifications. |
| 236 | Providing GI unions confirming to ISi specifications and fixing them in position as per directions. Including cost of materials, fixtures and conveyance to work spot etc. complete with all leads & lift at all levels. |
| 237 | 20mm dia |
| 238 | 25mm dia |
| 239 | 32mm dia |
| 240 | 40mm dia |
| 241 | Supplying, fixing, testing and commissioning of terrace water supply booster pumps with online disinfection system(UV) at terrace level, of adequate HP capable of giving a required discharge at suitable head,to work on 3 Ph 50 Hz, 415 V with necessary unions, flanges in 1:2:4 etc., complete., Rate quoted shall be inclusive of suitable control panel with auxiliary relays / contactors / timer for sequence operating for starting & stopping.and wiring from control panel and level controller to the pumps, butterfly valves, non-return valve, and control system, all the accessories, including lifting mechanism / structure arrangement for booster pumps etc (1working + 1 standby= 1 Set) Duty : 1200 Lpm at 25 M head |
| 242 | Supplying, fixing, testing and commissioning of water supply submersible pumps, of adequate HP capable of giving a required discharge at suitable head,to work on 3 Ph 50 Hz, 415 V with necessary unions, flanges in 1:2:4 etc., complete., Rate quoted shall be inclusive of suitable control panel with auxiliary relays / contactors / timer for sequence operating for starting & stopping.and wiring from control panel and level controller to the pumps, with required butterfly valves, non-return valve, GI B class pipe upto ground level and control system, all the accessories, including lifting mechanism / structure arrangement for pumps etc. (1working + 1 standby= 1 Set) Duty : 450 Lpm at 65 M head |
| 243 | Supplying, fixing, testing and commissioning of dewatering lifts pumps (Submersible type) of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph, 50Hz, 400/440V with necessary unions, flanges with water level controller with cabling etc., complete. Rate quoted shall be inclusive of suitable control panel with auxiliary relays/ contactors I timer for sequence operating for starting and stopping. and wiring from control panel and to the pumps etc. complete. with required butterfly valves, non-return valve, HOPE, PE 100, 10.0 KSC class pipe upto ground level and control system, all the accessories, including lifting mechanism / structure arrangement for pumps etc. Duty: 120 LPM at 35 M head (1 working+ 1 stand by= 1 Set) (for Dewatering) |
| 244 | Supplying, installing, fixing, jointing, testing and commissioning of approved make Chlorinated Polyvinyl Chloride pipes (CPVC) SCH 40, ASTM F 411, The fittings and specials such as tees, elbows, couplers, bends, enlargers etc.,with CPVC brass threaded combination/ transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the Engineer. Joints to be made with primer P-70, and solvent confirming to ASTM F-4931/724. |
| 245 | 65 mm dia |
| 246 | 80 mm dia |
| 247 | 100 mm dia |
| 248 | Supplying, installing, testing and commissioning 'approved make Butterfly valves conforming to BS 5155 with electro less nickel coated SG iron (N) and seat material of EPDM3, standard lever with necessary nuts, bolts, gaskets etc, complete. |
| 249 | 50 mm dia |
| 250 | 65 mm dia |
| 251 | 80 mm dia |
| 252 | 100 mm dia |
| 253 | 150 mm dia |
| 254 | Supplying, installing, testing and commissioning of Pressure gauges of suitable range for pump Sets and pipe lines for the respective floors near to the flow switches with Ball valves, siphon, Fittings like unions / colors / reducers etc. Glycerine filled pressure gauges to use on pump discharge lines. |
| 255 | Supplying, installing and testing of following approved 40 mm dia make fixing float valve with copper ball, required flanges, nuts, bolts, specials, fittings, conveying to work site, jointing, testing and commissioning including loading and unloading at both destinations including cutting, Welding, fixing, chipping, drilling, plastering in/ on walls & ceiling etc,. and tested quality including cost of all materials and labour at all heights and levels etc., complete as directed by the Engineer-in-Charge. |
| 256 | Supplying, installing, testing and commissioning of approved make 20mm dia. automatic air release valve with suitable size of ball valves and unions etc. complete. |
| 257 | Providing and fixing of suitable size of cable for the water level controler for above & below ground tanks for pump switching off and on. The cable shall be laid in tray/hume pipe/trenches/ on walls/floor etc. as required. the rate shall inculde for cables laid out door with required size PVC conduit, earth excavation providing brick and sand protection, refilling and compacting the earth. |
| 258 | Supplying, fixing and testing inlet, outlet, vent and overflow pipes, fittings with Cl frame and cover to overhead water tank and under ground water tank complete withrugs as shown on the drawings etc., complete, accessories comprising of the following : |
| 259 | UNDERGROUND/ ABOVE GROUND SUMPS ( RAW & TREATED WATER) Approx. depth= 3.8 Mts; 2 nos. Cl manhole frame & cover (heavy duty) 2 nos.inlet puddle flanges (80 mm dia.); 2 nos outlet puddle flanges (50mm dia}; 2; nos. vent pipe (100mm dia.} with mosquito proof mesh 2 Set PVC insulated steel rungs; 2 Nos. overflow puddle flange (100 mm dia.}; 2 Nos. Water level control puddle flange (50 mm dia.) 2 nos. fire over flow pipe 100mm; etc. complete for efficient maintenance of the tanks 0.0 0.0 |
| 260 | UNDERGROUND/ ABOVE GROUND SUMPS ( FIRE) Approx. depth= 5.8 Mts; 4 nos. Cl manhole frame & cover (heavy duty) 2 nos.inlet puddle flanges (80 mm dia.); 2 nos outlet puddle flanges (200mm dia); 2 nos. vent pipe (100mm dia.) with mosquito proof mesh 2 nos. 150 mm dia. class 'C' GI puddle flange; 4 Set PVC insulated steel rungs; 2 Nos. overflow puddle flange (150 mm dia.); 2 nos.inlet puddle flanges (150 mm dia.); 2 Nos. Water level control puddle flange (50 mm dia.); etc. complete for efficient maintenance of the tanks 0.0 0.0 |
| 261 | OVER HEAD TANK Approx. depth = 2 Mts; 2 nos. Cl manhole frame & cover (medium duty); 2 nos.inlet puddle flanges (50 mm dia.); 2 nos outlet puddle flanges (100mm dia); 2 nos. vent pipe (100mm dia.) with mosquito proof mesh; 2 Set PVC insulated steel rungs; 2 Nos. overflow puddle flange (65 mm dia.); 2 Nos. Water level control puddle flange (40 mm dia.); etc. complete for efficient maintenance of the tanks; Note : All puddle flanges to be hot dip galvanized. 0.0 0.0 EXTERNAL DRAINAGE WORKS 0.0 0.0 |
| 262 | Supplying, fixing, testing and commissioning of Self Priming Non Clog Sewage Pump lifting submersible pumps, of adequate HP capable of giving a required discharge at suitable head,to work on 3 Ph 50 Hz, 415 V with necessary unions, flanges in 1:2:4 etc., complete., Rate quoted shall be inclusive of suitable control panel with auxiliary relays / contactors / timer for sequence operating for pump starting and stopping based on Set pressures and wiring from control panel and level controler to the pumps, Pressure switches, pressure gauge, butterfly valves, non-return valve, and control system, all the accessories, including lifting mechanism / structure arrangement for the pumps etc,. 1W + 1SB |
| 263 | 110lpm @ 35m head for Stabling shed-1 |
| 264 | 64Ipm @ 15m head for Time and security Office |
| 265 | Providing and Laying reinforced cement concrete Pipe NP3 for culvert and other works including pointing ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing, with all leads & lift at all levels complete as per Specifications. |
| 266 | 300 mm dia |
| 267 | 250 mm dia |
| 268 | 150 mm dia |
| 269 | HDPE Pipes and Specials: Supplying, installing and testing of following diameter Non pressure HOPE pipes shall conform to IS 4984 . PN10. and specials including conveying to work site, rolling and lowering in to trenches, lying true to line, welding with electro fusion jointing, testing and commissioning including loading and unloading at both destinations and cuts of pipes wherever necessary including fittings and specials such as tees, elbows, couplers, bends, enlargers, supports at standard spacing, anchor fasteners, bolts, nuts, clamps, rails \\"U\\" & threaded bolt, and giving necessary hydraulic test Including excavation of all type of soil and fine sand supply and filling of 30cms all around the pipe & refilling of excavated soil etc,. complete as per specifications, drawings and as directed by the Engineer. 50 mm dia / OD 63mm Rm 690.0 0.0 RAIN WATER PIPES & FITTINGS AND OTHER WORKS 0.0 0.0 |
| 270 | Supplying, fixing and testing PVC pressure pipes (6Kg/sqcm) for rain water down take with solvent cement joints, including all the fittings, laid shaft / underfloor / concealed in wall etc, the work shall include wall chase and making good the same in cement mortar including bore packing & making the same good and water tight etc.,complete. |
| 271 | 110 mm dia |
| 272 | 160 mm dia ADDITIONAL ITEMS 0.0 0.0 |
| 273 | Excavating trenches of required width for pipes, cables etc including excavation for socket and dressing of sides ramming of bottoms depth upto 1.50 m including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed, within a lead of 50m. a) All kind of soil 0.0 0.0 |
| 274 | Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia. |
| 275 | Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm |
| 276 | Extra for excavating trenches for pipes, cables etc. in all soils for depth exceeding 1.50 m but not exceeding 3.00 Metre. (Rate is over corresponding basic item for depth up to 1.5m) |
| 277 | Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia. |
| 278 | Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm |
| 279 | Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5m. (Rate is over corresponding basic item for depth upto 1.5 metre.) |
| 280 | Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia. |
| 281 | Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm |
| 282 | Earth work in excavation by mechanical means (hydraulic excavator) / manual means over areas ( exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil. |
| 283 | Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture ofcement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete |
| 284 | 450mm dia RCC Pipe |
| 285 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : |
| 286 | 250 mm dia |
| 287 | 300 mm dia |
| 288 | Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : 0.0 0.0 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 120.0 0.0 |
| 289 | Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to2.29 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 290 | Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)finished with a floating coat of neat cement, all complete as per standard design : |
| 291 | 2.30 m deep with SFRC Cover and frame (heavy duty HD20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately)With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 292 | Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 293 | Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56 m dia at top with FPS class designation 75 in cement mortar 1:4 (1cement: 4 coarse sand}, inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement :2 coarse sand: 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, external plastering (1:4) all complete as per design. |
| 294 | 0.91 m deep with S.F.R.C cover and frame (Heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S.12592, fixed in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rest and 12mm thick cement plaster at the external surface shall be paid for separately) - With common burnt clay F.P.S. (Non-Modular) bricks of class designation 7.5. |
| 295 | Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 296 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement: 4 coarse sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete1:2:4(1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 297 | Extra for depth for manholes Size 90 x 80 cm With common burnt clay F.P.S. (Non- Modular) bricks of class designation 7.5 |
| 298 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS 1786 having minimum cross section as 23 mm x 25 mm and overall minimum length 263 mm and width as 165 mm with minimum 112mm space between protruded legs·having 2 mm tread on top surface by ribbing on chequering besides necessary and adequate anchoring projections on tall length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 299 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than2.70 kg as per standard design:150X100 mm Size P type With common burnt clay F.P.S (non modular) brick of class designation 7.5 |
| 300 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 301 | Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Rain Water Harvesting 0.0 0.0 |
| 302 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 0.0 |
| 303 | 300 mm dia. Rocky strata including Boulders 0.0 |
| 304 | 300 mm dia |
| 305 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia. |
| 306 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. |
| 307 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 308 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 309 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. |
| 310 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 311 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I) 200 mm dia |
| 312 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, Schedule 80, SOR 11 having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 63 mm OD |
| 313 | Providing and fixing SDR7.4 PE-Xe piping system with fittings, including jointing with compression sleeve conforming to ISO 15875 standard. Consisting of PE-X inner layer and a PE outer marking layer. All threaded fittings are made of DZR brass and non- metallic fittings and compression sleeves are made from PPSU and PVDF respectively, connections shall be through mechanical connection of compression sleeve mechanism complete including makings goods to wall, floor etc including required brackets, clamps, profile bent brackets complete in all respect. |
| 314 | 16mm OD |
| 315 | 20mm OD |
| 316 | 25mm OD |
| 317 | 32mm OD |
| 318 | Supply, installation, testing and commissioning of the compact brass ball valve with motorised actuator complete with float switch to acuate the motorised valve, contactor with control panel, 3 phase, 415C AC supply complete in all respects. |
| 319 | 32mm dia |
| 320 | Drinking/Warm Water Pump (Hydropneumatic System With Variable Speed Pumps) Providing, fixing and testing of skid mounted variables frequency drive hydropneumatic system with variable speed system comprising of:- Vertical, inline multistage centrifugal pumping Set with stainless steel SS-304 stage casing and SS-304 impellers with stainless steel SS-316L shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply. Pressure vessel of non corrosive FRP composite construction lined with NSF and/or FDA listed material, like high density polyethylene with fully replaceable polyurethane.Air cell burst pressure of minimum of 5 times the vessel operating pressure and cycle tested for 2,50,000 cycles. No. and capacity of Pressure Vessel - 02 Nos.- 85 Ltrs & 35 Ltrs. Control Panel with programmable logic controller (PLC) for cyclic operation of pumps. Pump working sequence should change after every operation.Contractor overload relays and MCBs should confirm to IEC 898 - 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter. Control panel should also consist of cooling fan. Main incomer MCB, Outgoing MCBs, Single phase preventors complete with auto manual swiches, dry run protection arrangements,Voltmeter/Ameter, Indication lights, Controller for dry run protection. Pressure transmitting relay bellow type fitted with micro switch and having maximum pressure and differential scale should confirming BS-6134 standards and IP55 protection class. GI heavy class(IS:1239) Suction and delivery header withbrass Ball valves with plastic coated handle(tested to 20kg/sqcm), Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. Brass NRVs (Test pressure =20 Kg/sqcm) to be used should be with Springs and O-Ring arrangement. Complete Set system to be mounted on a common base frame and shall follow following di.Jty(Skid shall be powder coated ). Including Energy Meters in all pumping mains 0.0 0.0 |
| 321 | Filter Feed Pumps(Set of Two Pumps One Working + One Standby) suitable to pump Warm water Capacity: app. 1250 LPH; Head:app. 30 m Set 1.0 0.0 |
| 322 | Drinking Water Pumps(Set of Two Pumps One' Working + One Standby) suitable to pump Fresh water Capacity:app. 2500 LPH; Head:app. 30 m Set 1.0 0.0 |
| 323 | Providing and fixing C.I double flanges suction strainer bucket type/ \\"Y\\" type including, nuts, bolts and 3mm thick rubber insertion complete. |
| 324 | 50mm dia |
| 325 | Providing and fixing 25mm thick C.I. heavy duty grating including C.I. / MS angle iron frame fixed with hold fast at 900mm c/c in flooring for the following sizes: |
| 326 | 300 mm wide x 600 mm long |
| 327 | Providing and fixing electronic type level indicator for water tanks mounting in panel with the following features, level display, alarm when water level is low or high, full range from one level to four level display and manual reSet for alarm etc. with electrical wiring conduit supports from wall & ceiling probs and all other accessories complete as required. |
| 328 | Providing, fixing, testing & commissioning of vertical MS pressure filter fabricated from MS sheet as per manufacturer's specifications with frontal piping & valve to provide service, backwash and rinsing operations. Water meter at outlet. Complete with intitial charge filter media. Including painting inside with two coats of non toxic water paint, one coat of zinc chromate two coats of synthetic enamel paint outside. Including sintex HDP chlroine tank of capacity 100 ltrs. with dosamatic doser, valves, piping & other accessories as per manufacturer's specs. RCC foundation with plastering and MS angle edging with epoxy paint for the entire equipment complete as required. |
| 329 | Filter for Domestic Water services. Tested pressure 5.2Kg/Sq.cm a) Capacity 1250 Lts/Hr Set 1.0 0.0 |
| 330 | Providing, fixing, testing & commissioning of water softening plant with frontal piping and valve and water meter, fabricated from MS plate and dished ends, as per manufacturer's specifications complete with T-40 Resin, valve at inlet point with Hydraulic Brine Injector and all other accessories. Painting as per Architect requirement. RCC foundation with plastering and MS angle edging with epoxy paint for the entire equipment complete as required. |
| 331 | Hardness: 600 Mg/L; Regeneration Period: 8 Hrs; Operating Pressure: 3 Kg. per sq.cm; Test Pressure: 5.2 Kg. Sq.cm. a) Capacity 1250 Lts/Hr Set 1.0 0.0 |
| 332 | Providing, fixing, testing & commissioning of polishing water softening plant with ACF (activated carbon filter) including frontal piping, valve and water meter at outlet, fabricated as per manufacturer's specifications complete with T-40 Resin, valve at inlet point with Hydraulic Brine Injector and all other accessories. Painting as per Consultant requirement. RCC foundation with plastering and MS angle edging with epoxy paint for the entire equipment complete as required. |
| 333 | Hardness: 50-100 Mg/L; Regeneration Period: 8 Hrs. a) Capacity 1250 Lts/Hr Set 1.0 0.0 |
| 334 | Providing and fixing automatic brine preparation system with HOPE salt mixing tank of capacity for 2 regenerations with chemical and concrete foundation as directed by the Engineer. |
| 335 | Providing and fixing C.I. Heavy duty rungs in R.C.C. wall of water tanks etc. Including cutting, chasing the R.C.C. work and making good the same complete as required. |
| 336 | Providing & fixing Electric control panel to open/close the solenoid valve at low/ high water level through level controller in soft water tanks. Including wiring, level controller probes & other accessories as required to operate the system automatically. |
| 337 | Providing & fixing pressure switch for water pumps to start/stop the pump at Set pressure. Including wiring, cabling from pump to panel & all other accessories as required to operate the system automatically. |
| 338 | Providing and fixing bronze Cleanout plug for cleaning. |
| 339 | 100 mm |
| 340 | Providing and Fixing sound-insulated mineral reinforced polypropylene pipe & fitting drainage system, conforming to BS EN 1451 standards, marking on pipe and fittings are as per EN1451 standards. The density of the pipe is greater than 1.20g/cm3 and the pipe connections are leak-proof up to an internal excess water pressure of 1.0 bar (coefficient of linear expansion should not be more than 0.09 mm/m X K), offering sound levels not more than 17db as per DIN4109 at a flow rate of 4Ips complete including goods to the ceiling, wall, floor and cutting into the chases wherever required to fix with necessary supports, brackets, and fasteners as per manufacturers recommendation. |
| 341 | 40mm OD |
| 342 | 50mm OD |
| 343 | 75mm OD |
| 344 | 110mm OD |
| 345 | Providing and fixing Polypropylene trap of self cleaning design complete including cost of cutting and making good the cut-outs in walls and floors etc. complete (P trap). |
| 346 | a) 110mm outer dia inlet and 110 mm outer dia outlet |
| 347 | Providing and fixing 100% stainless steel grating with frame of approved make and quality grade 304 on top of floor trap WITH COCKROACH JALI. The rate includes the cost of all ancillary works and material as required to complete the works. |
| 348 | 101x101 x1 mm |
| 349 | Providing and laying SN-8 DWC ID (HOPE BLACK) Pipe with full coupler and rubber ring conforming to IS:16098-2 including testing of joints, commissioning etc. complete: |
| 350 | 250 mm dia. |
| 351 | Providing and fixing 110mm outer Dia Polypropylene inlet fitting approximately 450/600 mm long with one or more 40163mm outer dia. PP socket with pushfit. |
| 352 | Transportation to and from for drilling rig, pipes, flanges and all other materials at site including erection & dismantling & demolization of drilling equipment, after completion of work including levelling, dressing, for erecting the equipment. |
| 353 | Drilling with 0TH (direct to hole) bore in all kind of soil including hard rock and disposal of surplus soil, removal and dumped to an approved area as instructed. a) 275/200 mm dia 0.0 0.0 |
| 354 | 0 - 30 meters |
| 355 | 30 - 60 meters |
| 356 | 60 - 90 meters |
| 357 | Supplying and lowering Blind Class ·c• MS pipe with welded ends including painting with two coats of anticorrosive paint complete as required. 200 mm dia |
| 358 | Supplying and lowering slotted Class 'C' MS pipe with welded ends. including painting with two coats of anticorrosive paints complete as required. 200 mm dia |
| 359 | Geophysical investigation of the aquifer by electrologing system with all tools and plants as necessary including supplying of necessary report |
| 360 | Labour for making arrangements for showing verticality test including the test for hire charges of tools and plants, scaffolding, labour etc. all completed |
| 361 | Supplying and fixing tubewell MS fittings as specified below : |
| 362 | 200mm dia. Housing clamp. |
| 363 | 200mm dia. well cap. |
| 364 | 200mm dia bail plugs. |
| 365 | 1.5. x 2.25 mm Pea Gravels. |
| 366 | Centering guide |
| 367 | Developing of both borewells till the sand free discharge is obtained through efficient air compressor. |
| 368 | Testing and over pumping (25% of tube well for 16hr to record draw down recovering (yield test) including flushing of both borewells. |
| 369 | By compressed air method/pump |
| 370 | Collecting sample of water for bacteriological and chemical test for any depth at any time during execution of work including hire and labour charges for tools and plants and sterilizing equipment, paying all charges and fees, testing etc. completed in all respects as per direction (As per IS 10500 all parameters |
| 371 | Supplying and installing cage for submersible pumps motor, fabricated out of 40mm x 6mm M.S. flat, welded construction and put to proper shape to hold pump enclosed and fixed around the mouth of pump Set including painting with two coats of anticorrosive paint complete as required. |
| 372 | Providing sanitary sealing on top as per 1.S. with 1:3:6 PCC Block of size 1m x 1m x 1m |
| 373 | Testing, commissioning and lowering of submersible pumps Set as per specifications (enclosed in cage) by using 'C' class column pipes (pipes included in separate column of schedule) including binding submersible cable, along with column pipes with suitable size of clamps. The submersible pump Set with direct coupled motor rated for 3 phase,50 cycle 415 ± 10% volts Ale supply with the required duty. |
| 374 | Providing and fixing Submersible pump Set as per specifications with direct coupled motor rated for 3 Phase, 50 Cycles 415±10% Volts, AC supply with the following duty. |
| 375 | Approx. Head- 300 m,Flow rate - 20000 ltr/ hr. ( Submersible pumps may be of Xylem / Grundfos/ aquanomics makes) |
| 376 | Supply & Installation of G.I. Class 'C' column pipe with flanges at 3m intervals including all fittings, flanges, clamps as required 65 mm dia |
| 377 | Supplying, fitting and fixing electric water level guard with 2 pole electrodes. |
| 378 | Supplying & Installation as specified the following |
| 379 | 1) G.I. Bend with Flange a) 65 mm dia Nos 23.0 0.0 |
| 380 | 2) Butterfly valve with flanges a) 65 mm dia Nos 2.0 0.0 |
| 381 | 3) Wafer type check valve with flange a) 65 mm dia Nos 2.0 0.0 |
| 382 | 4) Pressure Gauge with isolating valve |
| 383 | Supply, Installation, testing and commissioning of Electrical Panel Board for Tubewell, duly internally wired, made of 14 SWG sheet with 2 coats of finish painting with powder coating, including fixing the same in wall/ floor on Angle Iron Frame as per Site condition and fitted with the following: Incoming:- a) 63A TP MCCB - 1 No.; b) 1 No 96 mm voltmeter 0-500 V, with selector switch & control MCBs; c) 1 No 96 mm Ammeter of suitable range with CT's and Ammeter Selector switch & control MCBs. Bus Bars; d) 100A TPN Aluminium bus bar 0.0 0.0 Outgoing:- 2 Nos. 40 ATP MCB with DOL starter switch for motor. Each compartment shall contain CT operated ammeter with selector switch/ manual selector switch with indicating lamp, ON/OFF status of motor, level button and level cut off; 40A TP ON load changeover switch for after above two starters. 0.0 0.0 |
| 384 | Supplying and Installing of Copper arm cable for submersible pump cable of suitable rating (Tentatively-4 core x 4 sq.mm copper) from pump to Panel Board with cable clips, supporting clamps, glands, grommets etc. as required and as per specifications. Total of Schedule \\"H\\" 0.0 SOLADEVANHALLI DEPOT-SCHEDULE I***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. SI.No. Description of Item Unit Qty Rate (***Refer Note) Amount INR SCHEDULE I: EFLUENT AND SEWAGE TREATMENT PLANT(ETP & STP) Works & |
| 385 | The unit consist of Effluent treatment plant of capacity 100 KLD & Sewage treatment plant of capacity 55 KLD below the ground with separate collection sumps for ETP & STP for the service yard of BSRP. The collection sumps with Bar screens shall be a part of the unit. The ETP & STP shall be designed as a single unit with water retaining structures in RCC with RCC top structure and MS epoxy coated, non-skid type removable manhole covers, including piping, valves, necessary chemical dosing as required by the manufacturers design. All the equipments, piping, pumps, blowers and electrical are as per manufacturers design & are to be housed in a common plant room for both ETP & STP also to be built below the ground level including excavation in all kind of soil {hard rock) dewatering, refilling, watering, ramming removing and disposal of the surplus excavated material as per Instructions by site incharge. All MS galvanized puddle flanges, inlet- outlet, overflow, vents, covers, electronic type level indicator in all water tanks, drain channel with Cl gratings & sump for housing pumps. Contractor shall engage expert agency/ Manufacturer for design, construction, fabrication and installation of ETP & STP plants and submit peer review/vetted design from institution/agency for approval by Employer before execution of work. The contractor shall include the cost of design and peer review from the expert agency/institution in the quoted rate.The ETP & STP shall be complete in RCC and consist of the following units but not limited to these units as may be required by the manufacturer's design to meet the requirement of treated ETP I Sewage discharge norms as per local body for final disposal/ recycling as per PCB & Environmental norms as required for Flushing water supply/ Irrigation and HVAC TOP up tank.Including all type of civil work and ventilators.including excavation in all kind of soil {including hard rock), dewatering, refilling, ramming, removing and disposal of the surplus excavated material as per instructions by site in charge and making good the same complete as required with all leads & lift at all levels. Separate collection cum equalization sumps for collecting the effluent & sewage separately in respective sumps (RCC). Aeration tank fitted with diffusers at the Bottom for STP (RCC).Secondary Clarifier having a feed pipe with a Provision of scum removal and launders with weir plate etc. with sludge recirculation Arrangement by airlift pump (RCC); Surge tank of capacity 55 Kl/day for STP for Collecting the treated water (RCC); PVC hypochlorite dosing tank (100 ltr. Cap), 1 no. with suitable capacity dosing pump; 1 no. Sludge holding tank of capacity 5 kl each for collecting the sludge generated from the ETP STP(RCC); Flash mixer of suitable capacity for the mixing of effluent & dosing chemicals (RCC); Collection tank of 5-10 kl capacity to collect the chemically treated effluent prior to OAF dissolved air floatation unit (RCC); Primary Settling tank for the ETP with fixing arrangement of PVC media, complete with scum removal & launders with weir plate etc. The tank shall have sludge removal arrangement at the bottom (RCC); Oil collection arrangement from the OAF & tube Settler; Surge tank of capacity 100 kl/day (50 KL X 2 nos.) for ETP to collect the treated water (RCC) Irrigation / Flushing water tank of capacity 50 KL /day to collect the filtered water. Chlorine contact tank of capacity 15 Kl/day to collect the STP treated water (RCC); Common plant room drainage sump/pit to collect the waste water from the backwashes drains, filter press etc., with suitable submersible drainage pumps to lift the wastewater & to transfer into the collection sump; All pipeline in MS/GI/HOPEIPVC/CI (mild steel/galvanized iron/high density polyethylene/polyvinyl chloride/cast iron}, valves & fittings for necessary interconnections between pumps & tanks, overflows, sludge withdrawal, drain etc. with protective coatings. Supply of all required shop drawings by the contractor and approved by consultants. STP and ETP as described above including all type of civil and MS structural work complete as required |
| 386 | SUMP PUMPS FOR STP Supplying, Installing, testing and commissioning of non-clog 35mm solid handling type fully submersible pumps (1 working + 1 standby= 1 Set) in sump. The pump shall be complete in S.S. including lifting arrangement for the pumps including piping, valves on the discharge of pumps, level controllers, probes, cable, etc. including connection to STP 0.0 a) Capacity - 1.5 LPS @ 6-8m head 0.0 |
| 387 | SUMP PUMPS FOR ETP Supplying, Installing, testing and commissioning of non clog 50mm solid handling type fully submersible pumps (1 working +1 standby= 1 Set) in sump. The pump shall be complete in SS including lifting arrangement for the pumps including piping, valves on the discharge of pumps, level controllers, probes, cable, etc. including connection to ETP 0.0 a) Capacity - 8000 LPH at a head 6-8 mtrs. 0.0 |
| 388 | AGITATOR FOR FLASH MIXER FOR (ETP) Supplying, Installing, testing and commissioning of Agitator with suitable speed complete with motor, gear box & mounting arrangement. Shaft & impeller shall be in SS.Motor rating: 1HP; RPM: 90-120; Type :Turbine 0.0 |
| 389 | BAR SCREENS FOR ETP & STP Supply of bar screen 1Set for ETP's effluent collection sump and 1Set for STP's collection sump. The screen shall be in SS. 0.0 |
| 390 | AIR DIFFUSION SYSTEM CONMMON FOR ETP & STP Supply, Installing, testing and commissioning of air diffusion system shall include the following : 3nos. Twin type rotary air blower (2working & 1standby = 1Set) driven through V-belt or directly coupled through flexible coupling to a TEFC (totally enclosed fan coil) motor of suitable rating for 415 ± 10% volts, 3phase, 50 cycles AC with all accessories ie. coupling, base frame, NRVs (non return valve). safety valves etc., - 1Set. The blower shall be operating through cyclic timers to enhance the life of blowers Carbon steel pipes (C class) complete with carbon-steel fittings suchas tees, crosses, plugs, sockets, elbows, reducers, supports and clamps.Puddle flanges etc. including epoxy coating of the pipes over a coat of primer -1 Set Non clog type air dispersion system capable of handling 4-5 cfm of air with oxygen transfer efficiency of 3-4% per meter of water depth. Air dispersion grid shall be assembled in the modular form of MOC SS (mode of construction stainless steel) so that they can be repaired /replaced easily fromthe top. 0.0 |
| 391 | PVC MEDIA, FOR TUBE SetTLER(ETP) Supplying, Installing, testing and commissioning of PVC media in the tube Settler at an angle of 60 Degree for the effective Settling of sludge by increasing the Settling area. 0.0 |
| 392 | DOSING SYSTEM FOR ETP Supplying, installing, testing and commissioning of Chemical dosing system Consisting of the following: Dosing tanks of capacity:500 ltrs (2nos) & 100 litres (1no) in HOPE (High density polyethylene) Dosing pumps, Pi0diapraghm metering type suitable for handling lime, poly & ferric with adjustable capacities. 06 nos. 02 nos (1 working +1 standby=1 Set) for handling each dose chemical. 0.0 |
| 393 | DISSOLVE AIR FLOATATION SYSTEM FOR ETP Supply, Installation, testing & Commissioning of dissolved air flotation unit in MS construction with epoxy coating The OAF (Dissolve air floatation)shall have suitable feed pumps in SS Dia. : 1500 mm: Super cell tank :600 mm; Over height : 1000 mm Capacity ; 8 kl/hr 0.0 |
| 394 | FILTER FEED PUMPS FOR ETP. Providing and fixing vertical online pumping Set (1working + 1stand by = 1Set) complete in SS with Cl base to feed water to the filter. The pump shall have TEFC (totally enclosed fan coil) induction motor mounted on a common base frame with coupling guard, 150mm dia pressure gauge and GM isolation cock motor to be suitable for 415V + 10% V, 3 phase. 50 cycles AC power supply. including all necessary piping, valves and other accessories tille the plant room. RCC foundation with plastering and MS angle edging with epoxy paint for the entire equipment complete as required. 0.0 |
| 395 | MULTIGRADE FILTER FOR ETP Providing, fixing, testing & commissioning of vertical pressure filter in MS as per manufacturer's specifications with frontal piping and valve to provide service, backwash and rinsing operations complete with initial change of filter media. RCC foundation with plastering and MS angle edging with epoxy paint for the entire equipment complete as required Test pressure - 5.2 kg/cm2 : Capacity - 10000 Ltr/Hr 0.0 |
| 396 | IRRIGATION WATER PUMPS FOR STP Providing and fixing vertical online pumping Set (1 working + 1 standby= 1 Set) complete in SS withCI base to transfer the water for irrigation. The pump shall have TEFC (totally enclosed fan cooled) induction motor mounted on a common channel base-plate with coupling guard; 150 mm dia. pressure gauge, GM isolation cock. Motor to be suitable for 415 V +.10%, 3 Phase, 50 cycles AC power supply. Including all necessary piping, valves and other accessories till the plant room. RCC foundation with plastering and MS angle edging with epoxy paint for the entire equipment complete as required. Capacity - 12000 LPH @ 50 mtr head 0.0 |
| 397 | FILTER FEED PUMPS FOR STP Providing and fixing vertical eriline pumping Set (1 working+ 1 standby= 1 Set) complete in SS with Cl base to feed water to the filter. The pump shall have TEFC (totally enclosed fan cooled) induction motor mounted on a common channel base-plate with coupling guard. 150 mm dia. pressure gauge, GM isolation cock Motor to be suitable for 415 +- 0%, 3 Phase, 50 cycles AC power supply including all necessary piping, valves and other accessories till the Plant room. RCC foundation with plastering and MS angle edging with epoxy paint for the entire equipment complete as required. a) Capacity - 6000 LPH @ 30 m head 0.0 |
| 398 | MULTIGRADE FILTER FOR STP Providing, fixing, testing & commissioning of vertical - pressure filter in MS construction as per manufacturers specifications with frontal piping and valve to provide service, backwash and rinsing operations. Complete with initial charge of filter media.. RCC foundation with plastering and MS angle edging with epoxy paint for the entire equipment complete as required. Test Pressure - 5.2 Kg/Cm2; Capacity - 6000 Ltr/Hr 0.0 |
| 399 | ACTIVATED CARBON FILTER FOR STP Providing and fixing vertical MS [filter using activated carbon as filter media Frontal piping with valve for service, rinse & backwash along with other accessories. RCC foundation with plastering and MS angle edging with epoxy paint for the entire Equipment Complete as required. Test pressure- 5.2 Kq/Cm2; Capacity- 6000 Ltr/Hr |
| 400 | SLUDGE LIFTING PUMP FOR ETP Providing and 'fixing horizontal, centrifugal Sludge lifting pump to (1 working and 1 standby= 1 Set) transfer sludge from the Tube Settler of ETP to sludge collection tank. The pumps shall be complete in SS with Cl base easing, shaft with mechanical rotary shaft seal connected by a flexible tier type coupling to a TEFC induction motor mounted on a common channel base-plate with coupling guard, 150 mm dia. pressure gauge, GM isolation cock, suitable vibration eliminator, pads of approved design. Motor to be suitable for 400/440 V. 3 phase, 50 cycles AC power supply including all necessary piping, valves and other accessories Capacity - 5000 LPH @ 10 m head 0.0 |
| 401 | FILTER PRESS WITH SCREW PUMP (STP & ETP) Supplying, installing, testing and commissioning of Filter press Ratchet- Type of suitable size with 02 nos, screw pump (1 working + 1 standby = 1 Set), pipelines & valves, electrical feeder & cabling Fitter press slze;18\\" x 18\\" x 16 nos. plates in PP (poly propylene) Screw pump capacity: 3 CMH@ 5 Kg/Sqcm pressure 0.0 |
| 402 | DRAINAGE PUMPS Supplying, Installing, testing and commissioning of non-clog 10mm solid handling type fully submersible pumps (1 working + 1 standby = 1 Set) complete in SS In plant drainage pit to transfer the waste water into collection sump. The pump shall be complete in S;S. including lifting arrangement for the pumps including piping, valves on the discharge of pumps, level controllers, probes, cable, etc. including connection to STP Capacity - 6000-8000 LPH @ 5-6 m head 0.0 |
| 403 | Providing, fixing, testing and commissioning of air vessel Tank made from 6 mm thick M.S. plate of 450mm dia & 2m height with dished ends of 8mm thick, supporting legs, inlet & outlet flanged connections, pressure switches with valve to operate as per operating sequences including 50 mm dia. drain valve, air release valve with stop cock on the top duly painted from. inside and outside complete as required. |
| 404 | Supplying, 'Installing, testing and commissioning of control panel all weather proof, I Set cubicle type, floor mounted for all the equipment, fitted with all the. necessary switch- gears Indicating lights and spares to run the system automatic/manual. including level controller, wiring, cabling to the various equipment like blowers, pumps and chlorination systems., The control panel will level all the necessary electrical protection such as thermal overload relays single phase prevention and interlocking |
| 405 | Approval from pollution control board including arranging raw sewage for testingI and commissioning. Contractor shall include the cost of all chemicals (consumed during testing & commissioning) and the cost of such items of works which are not explicitly mentioned above but are mandatory to have Pollution Control Board approval. Total of Schedule \\"I\\" 0.0 SOLADEVANHALLI DEPOT - SCHEDULE J***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. S.No. Description Unit Qty. Rate (***Refer Note) Total Amount INR PART J -ELECTRICAL WORKS a) The BOQ specified below include the latest relevant standards (unless otherwise specified), specifications, drawing details and the contractor is required to go through them as referred in tender document while quoting the rates. All the samples/ material intended to be used in the works shall be subject to approval from the Employer. b) The description as mentioned in this BOQ including details as mentioned in GCC, SCC, Employers Requirement General specifications & Technical specifications, Drawing and the conditions mentioned therein whichever is stringent shall be applicable, acceptable and complied with. c) Sub-letting of work by the contractor shall only be permitted in accordance with relevant clause of Special Conditions of Contract. d) The quantity estimated here in BOQ are tentative. The items indicating zero quantity can also be operated and variation clause shall be applicable as stipulated in GCC / SCC. e) Calculation details for selection of equipments / materials shall be submitted for approval of Employer or his representative. f) The contractor should understand the requirements properly & quote accordingly. All necessary accessories, Materials and components not specifically stated in the specifications and/or bill of materials or noted on the drawings but which are necessary for satisfactory installation and operation of the system shall be deemed to have been included in the quoted rate and scope of work without any cost implication to Engineer / Employer. g) Likely approved list of manufacturer/OEMs are provided as a part of General specifications. h) The Tender is percentage tender. The tenderer should quote the percentage (above/below/At par) and amount in “Summary of Bill of Quantities” considering this as a Turn-key contract. i) In case of any contradiction between BOQ / Specifications and Drawings, the most stringent conditions of the above will apply. j) In case of any modification to the item description, then the rates shall be derived from the similar BOQ items if available. k) All steel structure/pipes shall be earthed. l) All materials and equipment shall be new, latest advanced version and of the approved make and design and as per schedule of quantities conforming to contract specifications. m) OEMs are responsible for Supply, installation, Testing & commissioning of all Panels & equipment. All the Testing & Commissioning reports shall be verified & duly signed by OEMs for Submission to KRIDE. n) All the items not specifically mentioned here but necessary to make the system complete and suitable for desired application as per Technical Specifications and Drawings will be deemed to be included in the quoted prices o) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. p) The qty shall be paid as per actual measurement as executed q) All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded for the complete commissioning of complete system. J.01 M V SWITCHGEAR General Design, fabrication, assembling, wiring, Supply, installation, testing and commissioning of front operated front access cubical type indoor duty floor / wall / recess/ surface mounting, totally enclosed dust and vermin proof (minimum protection IP 54 & IK 10) panels with neoprene gaskets, fabricated from CRCA sheet steel of thickness not less than 1.6 mm in general and load bearing members with 2.0 mm and shall be folded and braced as necessary to provide a rigid support for all components with powder coated finish (minimum thickness 80 micron) with approved shade. Panels shall be suitable for 415 volts 3 phase 4 wire 50 Hz system to withstand symmetrical fault level of 50 kA 415 V±10%, including interconnections, bonding to earth, lifting hooks, space heater, compartmental light etc. and flush doors conforming to relevant IEC/IS (viz. IEC 61439, IEC61641) standard including the earth leakage protection complete as per specification & drawings as required and as given below. All internal wiring in the panels shall be carried out using FRLSZH wires. a) Galvanized hardwares with Zinc passivation shall be used. b) The Switchboards shall be provided with detachable gland plates of 3mm thick for entry of cables from the top/bottom as required. c) All panels shall be of Totally Type tested assembly (TTA) with form 4b/ type-6 of construction conforming to IEC-61439 including earth fault protection complete as per specification with internal arc withstand as per IEC-61641. d) All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars shall be insulated with heat shrinkable sleeves. SMC/DMC (Double Moulding Compound) shrouds and busbar supports suitably spaced shall be used. Hinged doors with padlocking facility shall be provided on all outgoing feeders with switch handles lockable in OFF position. Hinged doors with neoprene type gasket & triangle key lock facility shall be provided. e) The panel shall have tinned Copper busbars (phases, neutral & earth) with bar type feeder connections, spacers etc. Phases & neutral busbar shall be of 100% capacity and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standard. Busbar sizing calculation shall be submitted for approval of Engineer / Empoyer. f) All accessories & supporting structures such as channels, ISMC base frame, mounting brackets, lifting lugs, panel heaters, ventilation arrangement etc as required. g) Each incomer and outgoing feeder shall be provided with suitably rated MCB control multiple LED/neon type status indication lamps(R,Y,B) for phase indication and ON,OFF & Trip (Red,green,Amber) with all required accessories suitable for 230 V AC as approved. h) Overall Space provision shall be @ 25% for future expansion and panel should be future extandable at both sides. Space heaters, compartment lights, lifting hooks as required and two numbers of Earthing terminal to be provided. i) The makes of components and accessories shall, to the extent practically feasible, be same for panels and boards for uniformity, standardisation and replaceability and shall be applicable to all panels/ boards under the scope of work j) Switchboard including interconnections, labelling, earthing & erection etc. complete as required. Labling of switch boards shall be with suitable size of Engraved metal plate, no Stickers shall be used. The Panel name boards shall be visible & the size shall be as per requirement. k) All the ACB's are with ( ANSI-49, 51, 51TD, 50, 51 N, 51N TD, 51G, Zone Selectivity 68, undervoltage – 27, Over Voltage 59, Residual Current 64) in build protection, with embedded communication, through communication it must able to communicate ON/OFF/Trip status,Spring Charge Storage (Charged or Discharged), ACB Position – Connected, test and disconnected position, removed,Event and trip log,Contact wear indication,No. of Tripping operations LSIG , and measuring 3 ph RMS voltages, Current, KW, KVAH, PF of all the phases individually and total with Class 1 accuracy metering, etc as per specifcation, For UV ANSI 27 and Overvoltage ANS 59 it must give the alarm and then trip command. l) All MCCBs shall be provided with potential free contacts for connectivity to PLC/BMS SCADA for ON/OFF status and control, as required.All incoming & outgoing of main LT panel, Main Emergency panel and all other panel Incomers must be communicate with BMS on ON, OFF and Trip status, Event and trip log,Trip Counter after LSING trips, Operating hours counter,Switching cycle counter,THDI, energy parameter (V,A,KW,KVA,etc), Temperature of the cabinet , wear of the contacts through open protocol like Modbus over TCP/IP m) MCCBs shall be compact suitably designed to provide protection of motors, cables, busbars to suit rated current, unbalanced power distribution as required and with front adjustable overload and short circuit releases and minimum electrical endurance of the order of 7000-8000 operation cycles (higher shall be preferred). MCCB from 250 A rating shall be Utilization category B n) All outgoing MCCBs shall be double break with current limiting type microprocessor based, 40% to 100 % Overload protection Adjustable short circuit from Isd 1.5 - 10 x Ir and tsd I^2t ON/OFF with variable time,with variable current protection, Service short circuit breaking capacity (Ics suitable for isolation conforming to latest IEC60947-2 duly marked on MCCB, at operating voltage (Ue) of 415 V, insulation voltage (Ui) 750 V and with trip free mechanism, handle indicating ON/OFF/tripped position. The breaking capacity as mentioned shall be Ics values ( Ics=Icu ). All incoming MCCB the breaking capacity must be Ics=Icu=Icw. o) MCBs shall conform to IEC 60947-1&2, IEC898/IS 8828 (latest) and, with breaking capacity 10 kA at 415 V AC, current limiting type, lower power loss approx 40 -70% of the stipulated value and suitable for magnetic releases operating between 3 to 5 times rated current for normal power distribution application and 5 to 10 times rated current for motor application duty, with minimum Electrical endurance of the order of 20000 operation cycles. p) Panel/board design shall be compact and components / accessories of compact sizes are used to economise the room space available. Employer reserve the right to seek compact items in place of larger ones q) All incomer ACB's shall be provided with minimum 6 NO + 6 NC auxiliary contacts and all MCCBs shall be provided with 3 NO+ 3 NC auxiliary contacts, and there should be provision to add min. 3 Auxiliary contacts. r) All 4-pole ACBs shall have fully rated neutral pole. All 4-pole ACBs & MCCBs shall be provided earth fault protection & netural protection. s) The panels shall be provided with polymer based fire trace tube system. Scheme of fire trace tube system shall be got approved by Engineer / Engineer / Employer before proceeding with manufacturing and assembly. Cost for this item shall be paid under suitable Item of Fire fighting works. Contractor shall interface with OEM of panel and Panel flooding system and ensure that the provision is made during fabrication of panel itself. t) All internal wiring to be with FRLSZH wires. u) Class \\"B\\" SPDs shall be provided in all DBs and Panels. v) All the items not specifically mentioned here but necessary to make the system complete and suitable for desired application as per Technical Specifications and Drawings will be deemed to be included in the quoted prices Note: Vendor shall provide an earmarked terminal boards for SCADA signals as per specification & requirements. w) OEM has to supply the software platform -web based portal for multiple user (minimum 50) to monitoring status of Energy consumption,demand, power,PF & energy costs. The software shall be capable to benchmark multi site systems (2 depots ) , easily scalable to future depots . The platform should support as repository to provide maintenance documentation, sharing panel information with maintenance team members ,alerts from meters, set preventive maintenance alerts, asset management, wear & tear of contacts, predidictive maintainance. The platform shall facilitate adherance to ISO 50001. The software licence shall be for 20 years period post which it shall be renewed /subscribed again.This is for main LT and Emergency LT panel only. x) HMI ( panel View ) 1 no. each for Main LT panel And Emergency LT panel with pass word protection. 12 Inch Advanced TFT screen XGA 1024*768 Pixels , Modular construction ,with 2 ethernet Ports , 2 serial ports , SD card , 512KB back up memory, configuring all devices in Modbus TCP in IEC61131-2 compliant , UL 508 compliant , RoHS complaint. y) Incomer of Main LT panel & Main Emergency panel shall be provided with power quality analyser strictly as per the specification. z) All Panels Incoming & Outgoing Terminals shall be Bolt & Nut type to terminate the Aluminum & Copper cables of Higher sizes. 1.1 MAIN LT PANEL @ ASS Set 1.0 0.0 A INCOMER - TRANSFORMER - 1 a) 4000 amps Four pole electrically operated (motorised) fully draw out type air circuit breaker (minimum 50 kA) with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting. and with the following accessories : i 3 nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden and Class 0.5 for measurement. ii 3 nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden and Class 0.5 for APFC relay iii 4 nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden & Class 5P10 for protection. iv 7 nos nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden & Class PS, RCT: 16 ohm, Imag:30mA @ Vk/2, Vk value shall be >=530V for Differential & Restricted Earth Fault protection. v 1 no of Power Quality meter of accuracy class-0.5s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. vi 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. vii 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs viii 1- set Red/Green ON/OFF indicating lamps ix 1- set of three phase (red, yellow, blue) indicating lamps x Amber healthy/ trip indicating lamps xi 230 V AC shunt trip coil xii 230 V, AC Motor wound spring closing mechanism xiii Terminals to receive copper sandwich bus duct xiv TNC Switch xv Auto/local/remote selector switch key operated xvi RJ-45 port for ON/OFF Command and trip Status communication on BMS,current and energy parameters etc. of ACB on BMS workstation through MODBUS over TCP/IP protocol. xvii Class \\"B\\" SPDs shall be provided in all DBs and Panels. xviii Potential free contacts needs to be provided ON,OFF,TRIP status to interlock with HT. xix Note: Contractor shall provide an earmarked terminal boards for SCADA signals as per specification & requirements. B BUSBAR a) Electro-tin plated, hard drawn, high conductivity, 99% Copper bars three phase and neutral busbars rated at 5000 A having a maximum current density as as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 50kA for 1 sec. at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% size of Phase bus shall be provided along the entire length of the panel or as per IEC or latest Standards.The neutral busbar to be extended up to bottom of the panel with suitable mounting arrangement to accommodate cables for REF protection. C OUTGOING a) 1 no 1250 Amps, , 415V, Ics=50 kA, Four pole electrically operated (motorised) fully draw out type air circuit breaker and with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting. i 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps. ii 3 nos. cast resin current transformers of 1250/5 ratio with 15 VA Burden and Class 1.0 for measurement. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv TNC Switch. v Auto/local/remote selector switch key operated. b) 2 nos. 1000 Amps, , 415V, Ics=50 kA, Four pole electrically operated (motorised) fully draw out type air circuit breaker and with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting. i 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps. ii 3 nos. cast resin current transformers of 1000/5 ratio with 15 VA Burden and Class 1.0 for measurement. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv TNC Switch. v Auto/local/remote selector switch key operated. c) 1 no 800 Amps, , 415V, Ics=50 kA,Four pole electrically operated (motorised) fully draw out type air circuit breaker and with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting. i 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps. ii 3 nos. cast resin current transformers of 800/5 ratio with 15 VA Burden and Class 1.0 for measurement. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv TNC Switch. v Auto/local/remote selector switch key operated. d) 2 nos. 200 Amps, , 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 200/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch. e) 2 nos.160 Amps, , 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch. f) 4 nos 100 Amps, , 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/Trip indicating lamps & 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch. D BUS COUPLER a) 4000 amps Four pole electrically operated (motorised) fully draw out type air circuit breaker 50kA with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage with adjustable setting with the following accessories : i 1- set Red/Green ON/OFF indicating lamps. ii 1- set of three phase (red, yellow, blue) indicating lamps iii Amber /healthy trip indicating lamps iv 3 nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden and Class 1.0 for measurement. v 3 nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden and Class 0.5 for APFC relay vi 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. vii TNC Switch. viii Auto/local/remote selector switch key operated. ix RJ-45 port for ON/OFF Command and trip Status communication on BMS,current and energy parameters etc. of ACB on BMS workstation through MODBUS over TCP/IP protocol. x Note: Potential free contacts shall be provided in the Panel boards for SCADA signals as per specification & requirements. E INTERLOCKING a) Two incomers & one Bus Coupler shall be interlocked electrically & mechanically so that only two out of three shall be switched on at a time (Auto / Local / Remote mode). F INCOMER - TRANSFORMER - 2 a) 4000 amps Four pole electrically operated (motorised) fully draw out type air circuit breaker (minimum 50kA) with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting and with the following accessories : i 3 nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden and Class 0.5 for measurement. ii 3 nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden and Class 0.5 for APFC relay iii 4 nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden & Class 5P10 for protection. iv 7 nos nos. cast resin current transformers of 4000/5 ratio with 15 VA Burden & Class PS, RCT: 16 ohm, Imag:30mA @ Vk/2, Vk value shall be >=530V for Differential & Restricted Earth Fault protection. v 1 no of Power Quality meter of accuracy class-0.5s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. vi 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. vii 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs viii 1- set Red/Green ON/OFF indicating lamps. ix 1- set of three phase (red, yellow, blue) indicating lamps. x Amber healthy/trip indicating lamps. xi 230 V AC shunt trip coil xii 230 V, AC Motor wound spring closing mechanism xiii Terminals to receive copper sandwich bus duct xiv TNC Switch xv Auto/local/remote selector switch key operated xvi RJ-45 port for ON/OFF Command and trip Status communication on BMS,current and energy parameters etc. of ACB on BMS workstation through MODBUS over TCP/IP protocol. xvii Class \\"B\\" SPDs shall be provided in all DBs and Panels. xviii Potential free contacts needs to be provided ON.OFF,TRIP status to interlock with HT. xix Note: Contractor shall provide an earmarked terminal boards for SCADA signals as per specification & requirements. G BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 5000A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 50 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. H OUTGOING a) 2 nos. 1000 Amps, , 415V, Ics=50 kA, Four pole electrically operated (motorised) fully draw out type air circuit breaker and with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable settings. i 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps. ii 3 nos. cast resin current transformers of 1000/5 ratio with 15 VA Burden and Class 1.0 for measurement. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv TNC Switch. v Auto/local/remote selector switch key operated. b) 1 no 800 Amps, 415V, Ics=50 kA, Four pole electrically operated (motorised) fully draw out type air circuit breaker and with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting. i 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps. ii 3 nos. cast resin current transformers of 800/5 ratio with 15 VA Burden and Class 1.0 for measurement. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv TNC Switch. v Auto/local/remote selector switch key operated. c) 2 nos.630 Amps, , 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 630/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch. d) 1no. 400 Amps, , 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch. e) 2 nos. 200 Amps, , 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 200/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch. f) 4 nos. 160 Amps, , 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch. g) 1 no. 125 Amps, , 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 125/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch. h) 2 nos. 100 Amps, 415V, Ics= 50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. I METERING a) 1 no., 230V, AC operated integral type LCD Display Digital meter with RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/ criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.2 MAIN EMERGENCY PANEL @ ASS Set 1.0 0.0 A INCOMER - 1 a) 1000 amps Four pole electrically operated (motorised) fully draw out type air circuit breaker (minimum 50 kA) with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting and with the following accessories : i 3 nos. cast resin current transformers of 1000/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 3 nos. cast resin current transformers of 1000/5 ratio with 15 VA Burden & Class 5P10 for protection. iii 1 no of Power Quality meter of accuracy class-0.5s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iv 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. v 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs vi 1- set Red/Green ON/OFF indicating lamps vii 1- set of three phase (red, yellow, blue) indicating lamps viii Amber healthy/ trip indicating lamps ix 230 V AC shunt trip coil x 230 V, AC Motor wound spring closing mechanism xi Terminals to receive Aluminium cable xii TNC Switch xiii Voltage sensing relay for AUTO change over. xiv Automatic change over switch xv Auto/local/remote selector switch key operated. xvi RJ-45 port for ON/OFF Command and trip Status communication on BMS,current and energy parameters etc. of ACB on BMS workstation through MODBUS over TCP/IP protocol. xvii Class \\"B\\" SPDs shall be provided in all DBs and Panels. xviii Potential free contacts needs to be provided ON.OFF,TRIP status to interlock with Main LT panel. xix Note: Contractor shall provide an earmarked terminal boards for SCADA signals as per specification & requirements. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 1200 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to withstand symmetrical fault level of 50 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 3 nos. 400 Amp, 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 1 no. 200 Amp, 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 200/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. c) 3 nos. 160 Amps, 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. d) 2 nos. 100 Amps, 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D BUSCOUPLER a) 1 no. 1000 Amps, 415V, Ics=50kA,Four pole electrically operated (motorised) fully draw out type air circuit breaker and with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting & each complete with:- i 1- set Red/Green ON/OFF indicating lamps ii 1- set of three phase (red, yellow, blue) indicating lamps iii Amber /healthy trip indicating lamps iv 3 nos. cast resin current transformers of 1000/5 ratio with 15 VA Burden and Class 1.0 for measurement. v 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. vi TNC Switch. vii Auto/local/remote selector switch key operated. viii RJ-45 port for ON/OFF Command and trip Status communication on BMS,current and energy parameters etc. of ACB on BMS workstation through MODBUS over TCP/IP protocol. ix Note: Potential free contacts shall be provided in the Panel boards for SCADA signals as per specification & requirements. E INCOMER - 2 a) 1000 amps Four pole electrically operated (motorised) fully draw out type air circuit breaker (minimum 50 kA) with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting and with the following accessories : i 3 nos. cast resin current transformers of 1000/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 3 nos. cast resin current transformers of 1000/5 ratio with 15 VA Burden & Class 5P10 for protection. iii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iv 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. v 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs vi 1- set Red/Green ON/OFF indicating lamps vii 1- set of three phase (red, yellow, blue) indicating lamps viii Amber healthy/ trip indicating lamps ix 230 V AC shunt trip coil x 230 V, AC Motor wound spring closing mechanism xi Terminals to receive Aluminium cable xii TNC Switch xiii Voltage sensing relay for AUTO change over. xiv Automatic change over switch xv Auto/local/remote selector switch key operated. xvi RJ-45 port for ON/OFF Command and trip Status communication on BMS,current and energy parameters etc. of ACB on BMS workstation through MODBUS over TCP/IP protocol. xvii Class \\"B\\" SPDs shall be provided in all DBs and Panels. xviii Potential free contacts needs to be provided ON.OFF,TRIP status to interlock with Main LT panel. xix Note: Contractor shall provide an earmarked terminal boards for SCADA signals as per specification & requirements. F BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 1200 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to withstand symmetrical fault level of 50 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. G OUTGOING a) 2 nos. 400 Amp, 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 2 nos. 250 Amps, 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 250/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. c) 2 nos. 200 Amps, 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 200/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. d) 2 nos. 160 Amps, 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. e) 1 no 100 Amps, 415V, Ics=50 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. H METERING a) 1 No., 230V, AC operated integral LCD Display type Digital meter with RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. I INTERLOCKING a) Two incomers & one Bus Coupler shall be interlocked electrically & mechanically so that only two out of three shall be switched on at a time(Auto/local/Remote mode) b) Supply changeover through ATS 1.3 NORMAL PANELS 1.3.1 NORMAL PANEL STABLING SHED No 1.0 0.0 A INCOMER a) 1 no. 160 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 200 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 8 nos. 63 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 4 nos. 32 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral LCD Display type Digital meter with RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.2 NORMAL PANEL CANTEEN No 1.0 0.0 A INCOMER a) 1 no. 100 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 120 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 3 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 4 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.3 NORMAL PANEL FOR ETU No 1.0 0.0 A INCOMER a) 1 no. 630Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 630/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 1000 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 1 no. 250Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 250 / 5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 1 no. 160Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. c) 4nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. d) 3 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. e) 1 no. 100 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.4 NORMAL PANEL P-WAY No 1.0 0.0 A INCOMER a) 1 no. 100 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 120 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 3 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 5 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.5 NORMAL PANEL DCO STORE No 1.0 0.0 A INCOMER a) 1 no. 100 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 120 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 5 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 2 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 no., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.6 NORMAL PANEL PIT - WHEEL LATHE No 1.0 0.0 A INCOMER a) 1 no. 100 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 120 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 3nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 4 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 no., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.7 NORMAL PANEL SUBSTATION-RSS No 1.0 0.0 A INCOMER a) 1 no. 100 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 120 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 6 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 4 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 no., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.8 NORMAL PANEL-PUMP ROOM PANEL No 1.0 0.0 A INCOMER a) 1 no. 160 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 200 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 2 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 4 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps . c) 8 nos. 05-20 Amp, 415V, Ics=25 kA, TPN MPCB & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 20/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch with 3/5 HP DOL starter, contactor, start & stop push button. D METERING a) 1 no., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.9 NORMAL MAIN PANEL-REEPAIR SHED No 1.0 0.0 A INCOMER a) 1 no. 1250 amps Four pole electrically operated (motorised) fully draw out type air circuit breaker 25KA with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault with adjustable setting and with the following accessories : i 3 nos. cast resin current transformers of 1250/5 ratio with 15 VA Burden and Class 1 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps. vi 1- set of three phase (red, yellow, blue) indicating lamps. vii Amber healthy/trip indicating lamps. viii 230 V AC shunt trip coil ix 230 V, AC Motor wound spring closing mechanism x Terminals to receive Aluminium cable xi TNC Switch xii Auto/local/remote selector switch key operated xiii RJ-45 port for ON/OFF Command and trip Status communication on BMS,current and energy parameters etc. of ACB on BMS workstation through MODBUS over TCP/IP protocol. xiv Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 1500 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 3 nos. 400 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 8nos. 250 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 250/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. c) 2nos. 160 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. d) 2 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green/Amber ON/OFF/TRIP indicating lamps & 3 nos. cast resin current transformers of 63/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 no., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.10 NORMAL PANEL -REPAIR AB BAY No 1.0 0.0 A INCOMER a) 1 no. 250 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 250/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 300 A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 1 no 200 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 200/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 4 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. c) 7 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 32/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 no., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.11 NORMAL PANEL-REPAIR BC BAY No 1.0 0.0 A INCOMER a) 1 no. 400 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 500A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 2 nos. 250 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 250/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 3 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. c) 8 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 no., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.12 NORMAL PANEL-REPAIR OFFICE-1 No 1.0 0.0 A INCOMER a) 1 no. 250 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 250/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 300A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 8 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 8 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps . c) 2 nos of 125 Amp,415,Ics=25 KA, TPN MCCB & with variable overcurrent and short circuit releases & each having 1-set Red/Green ON/OFF indicating lamps & 3 nos cast resin current transformer 125 / 5 ratio with 15VA burden & class 1.0 with ammeter & ammeter selector switch. D METERING a) 1 no., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.13 NORMAL PANEL-REPAIR OFFICE-2 No 1.0 0.0 A INCOMER a) 1 no. 400 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 500A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 18 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 1 no 125 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 no., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.14 NORMAL PANEL -INSPECTION BAY No 1.0 0.0 A INCOMER a) 1 no. 160 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 200A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 6 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 8 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamp. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.15 NORMAL PANEL -INSPECTION OFFICE No 1.0 0.0 A INCOMER a) 1 no. 125 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 125/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 150A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 5 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps . b) 7 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.3.16 NORMAL PANEL-ADMIN BUILDING No 1.0 0.0 A INCOMER a) 1 no. 200 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 200 / 5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 240A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 1 no 100 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 6 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. c) 3 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. d) 2 nos of 10 Amps,415,Ics=25 KA, TPN MPCB & with variable overcurrent and short circuit releases & each having 1-set Red/Green ON/OFF indicating lamps & 3 nos cast resin current transformer 10 / 5 ratio with 15VA burden & class 1.0 with ammeter & ammeter selector switch. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.4 ACDB Nos 2.0 0.0 A One A C distribution board (ACDB) unit with respective incoming TPN MCBs and outgoing SP MCBs each having indications for incoming feeder status as per specifications and as under: B INCOMER a) 1 no. 63A TPN MCB. b) 1 Set of (ON)) indicating lamps for each. c) 3 no. 63A DP RCBO for phase segregation. C OUTGOINGS with feeder (ON) indication LED lamps a) 36 Nos of 6 A SP MCB arranged in three row i 1no of Digital ammeter with selector switch and required set of CTs MCB and accessories. ii 1 Set of (0-500Volts) digital voltmeter with selector switch with 2 amps MCBs iii 1 Set Red/Green ON/OFF indicating lamps. iv 1 Set three phase (red, yellow, blue) indicating lamps. v Amber healthy /trip indicating lamps. 1.5 EMERGENCY PANEL 1.5.1 EMERGENCY PANEL MAIN STABLING SHED & Stabling shed-A, Internal cleaning No 1.0 0.0 A INCOMER a) 1 no. 160 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 200A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 7 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 9 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.2 EMERGENCY PANEL SUBSTATION No 1.0 0.0 A INCOMER a) 1 no. 160 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 200A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 11 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 3 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. c) 1 no 100 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.3 EMERGENCY PANEL-PIT WHEEL LATHE No 1.0 0.0 A INCOMER a) 1 no. 250 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 250/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 300A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 3 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 2 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. c) 2 nos. 250 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 250/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.4 EMERGENCY PANEL -DCO STORE No 1.0 0.0 A INCOMER a) 1 no. 100 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 120A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 4 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 2 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.5 EMERGENCY PANEL P WAY No 1.0 0.0 A INCOMER a) 1 no. 100 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 120A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 4 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 2 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.6 EMERGENCY PANEL CANTEEN No 1.0 0.0 A INCOMER a) 1 no. 400 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 500A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 4 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 6 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. c) 1 nos. 250 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 250 / 5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.7 EMERGENCY PANEL -ETU No 1.0 0.0 A INCOMER a) 1 no. 400 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 500A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 3 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 5 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. c) 5 no 100 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. d) 2 no 160 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.8 EMERGENCY PANEL-MAIN REPAIR SHED No 1.0 0.0 A INCOMER a) 1 no. 400 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 500A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 4 nos. 160 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.9 EMERGENCY PANEL REPAIR-AB BAY No 1.0 0.0 A INCOMER a) 1 no. 160 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 200A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 4 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. b) 2 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps . c) 2 nos. 125 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 125/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.10 EMERGENCY PANEL -REPAIR BC BAY & OFFICE No 1.0 0.0 A INCOMER a) 1 no. 160 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 200A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 2 nos. 125 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 125/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 6 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. c) 6 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.11 EMERGENCY PANEL ADMIN BUILDING No 1.0 0.0 A INCOMER a) 1 no. 160 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 200A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 2nos. 100 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 3 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. c) 4 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps. d) 2 nos. 10 Amp, 415V, Ics=25 kA, TPN MPCB & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 10/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch with DOL starter, contactor, start & stop push button. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.12 EMERGENCY PANEL-INSPECTION BAY No 1.0 0.0 A INCOMER a) 1 no. 160 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 160/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 200A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 7 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 63/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 8 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 32/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.13 EMERGENCY PANEL -INSPECTION OFFICE No 1.0 0.0 A INCOMER a) 1 no. 100 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. ix Class \\"B\\" SPDs shall be provided in all DBs and Panels. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 120A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 4 nos. 63 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 63/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.14 EMERGENCY PANEL(Fire pump panel) No 1.0 0.0 A INCOMER a) 1 no. 400 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCB. v 1- set Red/Green ON/OFF indicating lamps. vi 1- set of three phase (red, yellow, blue) indicating lamps. vii Amber healthy/ trip indicating lamps. viii Auto / Manual selector switch ix 230 V AC shunt trip coil x 230 V, AC Motor wound spring closing mechanism xi Terminals to receive aluminium cable B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 500A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 3 nos 250A MCCB 25 KA with 75/90 kW with fully automatic Star/Delta starter with over load protection, current sensing type single phase preventer complete with all accessories. and internal wiring required for automatic operation, and following points (One outgoing set shall be for each main Fire pump). ( 1w + 1 sb+ 1 spare) i 1- set Trip, ON & Run indicating lamps. ii Start, Stop push button iii Auto / Manual selector switch iv 3 nos. cast resin current transformers of 400/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. b) 2 nos 63A TP MCCB 25 KA with 7.5 to 15 KW fully automatic DOL starter with over load protection, current sensing type single phase preventer complete with all accessories and internal wiring required for below points i 1- set Trip, ON & Run indicating lamps. ii Start, Stop push button iii Auto / Manual selector switch iv 3 nos. cast resin current transformers of 63 / 5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. c) 1 no 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 32/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. d) The panel shall be complete in all respects as per specification having incomer and outgoing for operating 1 nos main fire pumps and 1 no jockey pump and rate of all the items are included in this. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.5.15 EMERGENCY PANEL (UPS PANEL) Nos 1.0 0.0 A INCOMER a) 1 no of 100 Amps, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each complete with:- i 3 nos. cast resin current transformers of 100/5 ratio with 15 VA Burden and Class 1.0 for measurement. ii 1 no of multifunction meter of accuracy class-1s with all required to measure and display the electrical quantities like current,voltage,active energy-KWA,reactive energy KVAH,frequency,maximum demand-KVA & KW,THDI & THDV,power factor etc with facility conforming to specifications and latest IEC standard with RJ-45 port with Modbus TCP/IP with ethernet protocol. iii 1 no of Digital ammeter with selector switch and required set of CTs,MCB and accessories. iv 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs v 1- set Red/Green ON/OFF indicating lamps vi 1- set of three phase (red, yellow, blue) indicating lamps vii Amber healthy/ trip indicating lamps viii RJ-45 port for ON/OFF and trip Status communication on BMS,current and energy parameters etc. of MCCB on BMS workstation through MODBUS over TCP/IP protocol. B BUSBAR a) Electrolytic high conductivity Copper three phase and neutral busbars rated at 120A having a maximum current density as per specification with heat shrinkable insulation sleeves suitable to with stand symmetrical fault level of 25 kA for 1 sec at 415 V. The neutral busbar is to be of same size as phases and Earthing Busbar shall be 50% of Phase or as per IEC or latest Standards. C OUTGOING a) 7 nos. 32 Amp, 415V, Ics=25 kA, TPN MCCB and with variable overcurrent and short circuit releases & each having 1- set Red/Green ON/OFF indicating lamps & 3 nos. cast resin current transformers of 32/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter Selector Switch. D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. b) The switchboard shall be complete with all inter connections, risers, internal wiring, labels etc complete as required. 1.6' FEEDER PILLAR FOR EXTERNAL LIGHTING 1.6.1 FEEDER PILLAR - EXTERNAL LIGHTING (OUTDOOR TYPE IP-65 WITH ENCLOSURE AS PER SPECIFICATIONS) Set 4.0 0.0 A INCOMER a) 1 no.63 A, 415V, Ics=25 kA, TPN MCCB’s with fixed neutral and with variable overcurrent and short circuit releases i 1 Set of (0-500 volts) digital voltmeter with selector switch with MCB’s, and one set of Digital Ammeter with 3 nos. 63/5 Amps, 15 VA, CT ii 1 No. 0-24 Hrs double dial timer iii 3 Nos. Auto / manual selector switch iv Phase indicating light and shall be protected by 2A MCB's v 3 Nos. 16 A TPN contactor with necessary NO& NC auxiliary contacts of 2 Sets. vi 1 Job of control flexible cabling from contactor to Timer B BUSBAR a) 100 amps TPN Copper bus bars with heat shrinkable insulation sleeve. C OUTGOING a) 5 Nos of 16 amps TP+N MCBs D METERING a) 1 No., 230V, AC operated integral type LCD Display type Digital meterwith RJ-45 port for measuring Amps ,Voltage, Energy, frequency & power factor conforming to specifications, latest IEC/ EMC and EMI standards/ criterion, with necessary Circuit MCB and supporting SCADA/BMS connectivity. 1.7' HYBRID POWER FACTOR CORRECTION PANEL (AUTOMATIC POWER FACTOR CORRECTION AND STATIC VAR GENERATOR) 1.7.1 HYBRID PANEL 400 KVAR -( 300 KVAR, 7% DETUNED REACTOR at 415V APFC Panel WITH 10% OVER VOLTAGE AND 100 KVAR STATIC VAR GENERATOR) Set 2.0 0.0 a) Supply, installation, testing & commissioning of cubicle type compartmentalized floor mounted Indoor free standing type with separation system as per IS:16636 part-1, IEC-61921 & IEC-61439-1&2 for 300 kVAR ,415V, 50HZ, 3 phase 4 wire LC Steps and 100 kVAR SVG . The combination of APFC panel and SVG panel.The APFC Panel shall be (Indoor) type, weather, dust and vermin proof.The Panel shall consist of ( 25 kVAR x 2+ 50 KVAR x 5 ) LC Steps and Stepless SVG of 100 kVAR. module . The hybrid system must be compatible for PF improvement and load balancing requirement. The panel shall be designed with Capacitor duty contactor switching and with 7% detuned Reactor and considering 10% Over Voltage . Switched Capacitors shall be Super heavy duty (MPP) , 3 Phase delta connected ,MPP type . b) The supply shall be moisture, dust and vermin proof IP-42 with proper cooling system with Programmable Microprocessor controller to maintain Power Factor for both leading and lagging PF ,through transformer and DG both ,Unbalance current and duly housed in epoxy powder coated 2mm LB and 1.6 mm NLB thick CRCA sheet steel compartmentalised enclosure free standing type with all supports, accessories, switch gears, control gears, protections, wiring, interconnections, control MCBs etc. as required complete in all respects & having its main components. The panel shall be only OEM make (TDK/SIEMENS/ABB/SCHNEIDER) and must fulfill all the testing procedures as per IS16636 standards . 1.7.2 IGBT BASED ACTIVE HARMONIC FILTER PANEL set 2.0 0.0 a) Active Harmonic Filter Panel shall have a rating of 100 Amp (100Amp x 1) plus 1 Spare feeder space for 100 Amp @ 415V 50HZ, 3 phase 4 wire supply, moisture, dust and vermin proof suitable for indoor application. AHF module shall be with 12 IGBT based (3 Level topology). The Busbar and Incomer as MCCB and other accessories shall be as per 200 Amp . It should comply IEEE519 standard. The AHF panel shall be as per OEM factory fitted and shall be tested in OEM factory at the time of Inspection . It should be as per approved make ( TDK-EPCOS/SIEMENS/ABB/ SCHNEIDER) 1.8 Other Accessories 1.8.1 Safety equipments in Aux. Substation/MDB room Set 1.0 0.0 Supply and fixing of the following safety equipments in Aux. Sub. Station /MDB room/Electrical switch gear room of all buildings as per detailed descriptions given below and as per relevant IE rules & code of standard practice:- a) 1000 mm wide Insulating rubber mat, confirming to IS 15652-2006 suitable to withstand LT Panel Requirements in front of all panels in ASS building and Electrical switchgear rooms of all sheds and offices. b) Laminated standard shock treatment charts in Kannada,English & Hindi in ASS, DG room and Pump room. c) Danger plate as per approved Style & sample written in Kannada,English & Hindi for MV installations as required as per IE rules, IES and IS 2551 (latest) for all panels d) 10 nos. First Aid Box Complete as approved by St. John ambulance or Indian Red Cross e) Fire Buckets with stand-10 nos f) Two Tool kit comprising 1 set of flat spanner (Taparia / Jalan), 1 set of box spanner, 1 no. Hacksaw frame with 10 No. blades, 1 no. large, medium, small screw drivers, 1 no. insulated plier, 1 no nose plier, 1 no. hand crimping tool upto 16 sqmm, 1 no. digital multimeter, 1 no. test lamp and 1 no. tester. Screw driver set for all types of screw heads also to be provided. J.02 DISTRIBUTION BOARDS General a) Design, Supply, installation, testing and commissioning of front operated , front access, factory fabricated and factory assembled pre wired, sheet steel clad powder coated, wall/recess/surface mounted dust and vermin proof (IP-54 ingress protection) double door vertical type, phase segregating Distribution Boards fabricated from 16 SWG sheet steel provided with hinged gasketed door with padlocking facility , triangular key lock and including suitably rated PVC insulated copper busbars with interconnections and neutral assembly, LED indicating lamps(R,Y,B,ON,OFF,TRIP) for incoming feeders,knockouts, 2mm thick gland plates for cable entry & conduit, independent netural & earthing terminals for each phase etc. complete as required, as below and as per sample to be approved by Engineer Incharge and as per specifications. b) MCBs shall conform to IEC898/IS 8828 (latest) and, with breaking capacity 9/10 kA at 415 V AC, current limiting type lower powerloss approx 40 -70% of the stipulated value and suitable for magnetic releases operating between 5 to 10 times rated current for normal power distribution application(C-Curve) and 10 to 20 times rated current for motor application duty(D-curve), with mechanical endurance of 20000 operation without load & electrical endurance of 10000 operation with load(under In at PF 0.9) c) Residual current circuit breaker (RCCB) / RCBO conforming to IS 12640 shall be provided with 100 mA sensitivity and electrically connected rated current capacity MCB for short circuit and over load protection as required d) The LDBs required Dimming Control / Timers equipment mountable on DIN rail for sheds & High bay lights. Contractor should refer to relevant specifications and drawings in this regard and submit his scheme for approval by Engineer in Charge. e) Class \\"B\\" SPDs shall be provided in all DBs and Panels. f) All internal wiring to be done with FRLSZH wires g) All incoming & outgoing feeders of DB shall be terminated on terminal blocks in the upper compartment including internal wiring by manufacturer, suitable place to be provide for cable Allay in the DB compartment. h) All the contactors shall be provided with potential free contacts for remote monitoring and control. i) All DB's are to be provided with Timers j) Various distribution boards as given below: 2.1 Distribution boards Type-1 8 way,1 no. 32 Amps, 4P, 10 kA, MCB with thermal magnetic protective releases incoming with 4 pole 32 amp HDHC tinned copper bus bar with coloured heat shrinkable PVC sleeves and 3 single phase banks each comprising of 32 amp DP 100 mA RCBO incoming and 8 nos 10/16/20 amps SP 10 kA MCB with thermal magnetic protective releases outgoings. Nos 10.0 0.0 2.2 Distribution boards Type-2 12 way,1 no. 32 Amps, 4P, 10 kA, MCB with thermal magnetic protective releases incoming with 4 pole 32 amp HDHC tinned copper bus bar with coloured heat shrinkable PVC sleeves and 3 single phase banks each comprising of 32 amp DP 100 mA RCBO incoming and 12 nos 10/16/20 amps SP 10 kA MCB with thermal magnetic protective releases out goings. Nos 2.0 0.0 2.3 Distribution boards Type-3 8 way,1 no. 63 Amps, 4P, 16 kA, MCCB with thermal magnetic protective releases incoming with 4 pole 63 amp HDHC tinned copper bus bar with coloured heat shrinkable PVC sleeves and 3 single phase banks each comprising of 63 amp DP 100 mA RCBO incoming and 8 nos 10/16/20 amps SP 10 kA MCB with thermal magnetic protective releases out goings. Nos 5.0 0.0 2.4 Distribution boards Type-4 12 way,1 no. 63 Amps, 4P, 16 kA, MCCB with thermal magnetic protective releases incoming with 4 pole 63 amp HDHC tinned copper bus bar with coloured heat shrinkable PVC sleeves and 3 single phase banks each comprising of 63 amp DP 100 mA RCBO incoming and 12 nos 10/16/20 amps SP 10 kA MCB with thermal magnetic protective releases out goings. Nos 5.0 0.0 2.5 Distribution boards Type-5 6 way,1 no. 32 Amps, 4P, 10 kA, MCCB with thermal magnetic protective releases incoming with 4 pole 32 amp HDHC tinned copper bus bar with coloured heat shrinkable PVC sleeves and 3 single phase banks each comprising of 32 amp DP, 100 mA RCBO incoming, 24hrs timer contactor and 6 nos 10/16/20 amps SP 10 kA MCB with thermal magnetic protective releases outgoings. Nos 48.0 0.0 2.6 Distribution boards Type-6 6 way,1 no. 63 Amps, 4P, 16 kA, MCCB with thermal magnetic protective releases incoming with 4 pole 63 amp HDHC tinned copper bus bar with coloured heat shrinkable PVC sleeves and 3 single phase banks each comprising of 63 amp DP 100 mA RCBO incoming and 6 nos 10/16/20 amps SP 10 kA MCB with thermal magnetic protective releases out goings. Nos 28.0 0.0 2.7 Distribution boards Type-7 DB with 25amp DP 10KA MCB with 1 nos incoming 25 amp DP 100 mA RCCB incoming & outgoing 6 nos 10/16 amps SP 10KA MCB Nos 4.0 0.0 2.8 HVAC Distribution Board. Nos. 2.0 0.0 Distribution board (HVAC-DB) unit with respective incoming 4P MCCBs having R,Y,B, ON,OFF TRIP indications for incoming feeder status as per specifications and as under: INCOMER a) 1 no. 160A, 16kA, 4P MCCB set at 125A. b) 200A, rated Cu, interconnection Busbar individually for all phases c) 3 no. 63A DP RCBO for phase segregation. d) 1 set of (R,Y,B, ON, OFF, TRIP) indicating lamps. OUTGOINGS with feeder. e) 21 Nos of 16 A SP MCB arranged in sets of 7 nos. per phase. f) 5 Nos of 63 A, 4P, MCCB. J.03 DISTRIBUTION CABLES General a) The Cable and Cable Containment System specified herein, must confirm to technical Specifications, in addition to the description given in respective items of BOQ , whether explicitly specified or not. In case of contradiction between specifications and description in BOQ, the most stringent of the condition will apply. b) \\"All the items / parts mentioned in relevant clauses of the technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded.\\" c) It may be noted that the Contractor will be required to carry out cable sizing based on actual cable lengths, as per working Drawings developed by him and after incorporating any changes in load requirements from the tendering stage. Optimization must be carried out during cable sizing to reduce the cable requirement and size. Further, Contractor must obtain Engineer's approval on the Cable Sizing Calculation. 3.1 Power and control cables (FRLSZH) Supply, installation, testing and commissioning of 1100 V grade, armoured, FRLSZH, XLPE, aluminium (AL) / Copper (CU) conductor cables generally conforming to IS 7098(part-1) & IEC-60502-1 on existing trays / walls/ columns/ indoor/trenches including identification tags, cable router at every 20 mtr distance, supports with suitable clamps, saddles, hooks, bolts etc. & in ground/ trenches including the cost of proper dressing of cables, markers providing identification tags, sand filling etc. The cost shall include heat shrinkable cable joining cable kits for joining cables wherever joints are unavoidable due to unavailability of required length of cable in standard drum length. Note 1: All cables 25 sqmm and above are AL conductors unless specified otherwise. 3.1.1 4 core 300 sqmm AL conductor cable Mtr 1500.0 0.0 3.1.2 4 core 240-sqmm AL conductor cable Mtr 4600.0 0.0 3.1.3 4 core 185-sqmm AL conductor cable Mtr 4500.0 0.0 3.1.4 4 core 150-sqmm AL conductor cable Mtr 3200.0 0.0 3.1.5 4 core 120-sqmm AL conductor cable Mtr 5000.0 0.0 3.1.6 4 core 95 sq mm AL. Conductor cable Mtr 1200.0 0.0 3.1.7 4 core 70-sqmm AL conductor cable Mtr 3552.0 0.0 3.1.8 4 core 50 sq mm AL. Conductor cable Mtr 98.0 0.0 3.1.9 4 core 35 sqmm AL Conductor cable Mtr 4600.0 0.0 3.1.10 4 core 25 sqmm AL Conductor cable Mtr 6900.0 0.0 3.1.11 4 core 16 sqmm CU Conductor cable Mtr 10520.0 0.0 3.1.12 4 core 10 sqmm CU Conductor cable Mtr 9340.0 0.0 3.1.13 4 core 6 sqmm CU conductor cable Mtr 90.0 0.0 3.1.14 4 core 4 sqmm CU conductor cable Mtr 980.0 0.0 3.1.15 4 core 2.5 sqmm CU conductor cable Mtr 1100.0 0.0 3.1.16 3 core 4 sqmm CU conductor cable Mtr 110.00000000000001 0.0 3.1.17 3 core 6 sqmm CU conductor cable Mtr 2300.0 0.0 3.1.18 3 core 2.5 sqmm CU conductor cable Mtr 2200.0 0.0 3.2 Supply, installation, testing and commissioning of 1100 V grade, armoured, FRLSZH, XLPE, aluminium (AL) / Copper (CU) conductor cables generally conforming to IS 7098(part-1) & IEC-60502-1 on existing trays / walls/ columns/ indoor including identification tags, cable router at every 20 mtr distance, supports with suitable clamps, saddles, hooks, bolts etc. & in ground/ trenches including the cost of proper dressing of cables, markers providing identification tags, sand filling etc. (cost of excavation, sand & bricks, included here) . 3.2.1 4 core 6 sqmm CU conductor cable Mtr 2450.0 0.0 3.3 Supply, installation, testing and commissioning of 1100 V grade, FRLSZH insulated multistrand flexible copper cable generally conforming to IS 7098(part-1) & IEC-60502-1 3.3.1 1Cx25 sqmm multistrand flexible cable(black colour) for UPS Mtr 92.0 0.0 3.3.2 1Cx16 sqmm multistrand flexible cable(black colour) for UPS Mtr 790.0 0.0 3.4 Cable end termination of the following XLPE FR LSZH aluminium/copper conductor armoured cables of 1100V grade including supplying and fixing of crimping lugs, double compression brass glands, cable sockets, insulation tape, earthing of gland armouring etc. 3.4.1 4 core 300 sqmm AL conductor cable Nos 48.0 0.0 3.4.2 4 core 240-sqmm AL conductor cable Nos 30.0 0.0 3.4.3 4 core 185-sqmm AL conductor cable Nos 27.0 0.0 3.4.4 4 core 150-sqmm AL conductor cable Nos 9.0 0.0 3.4.5 4 core 120-sqmm AL conductor cable Nos 41.0 0.0 3.4.6 4 core 95 sqmm AL. Conductor cable Nos 16.0 0.0 3.4.7 4 core 70-sqmm AL conductor cable Nos 18.0 0.0 3.4.8 4 core 50 sqmm AL. Conductor cable Nos 9.0 0.0 3.4.9 4 core 35 sqmm AL Conductor cable Nos 18.0 0.0 3.4.10 4 core 25 sqmm AL Conductor cable Nos 27.0 0.0 3.4.11 4 core 16 sqmm Cu Conductor cable Nos 210.0 0.0 3.4.12 4 core 10 sqmm Cu Conductor cable Nos 210.0 0.0 3.4.13 4 core 6 sqmm Cu conductor cable Nos 135.0 0.0 3.4.14 4 core 4 sqmm Cu conductor cable Nos 36.0 0.0 3.4.15 4 core 2.5 sqmm Cu conductor cable Nos 27.0 0.0 3.4.16 3 core 4 sqmm Cu conductor cable Nos 450.0 0.0 3.4.17 3 core 6 sqmm Cu conductor cable Nos 9.0 0.0 3.4.18 3 core 2.5 sqmm Cu conductor cable Nos 9.0 0.0 3.4.19 1 core 25 sqmm Cu multistrand flexible cable Nos 12.0 0.0 3.4.20 1 core 16 sqmm Cu multistrand flexible cable Nos 58.0 0.0 3.5 Cable Trays -Perforated a) Supply, fabrication & installation of perforated hot dipped galvanised double bended cable trays from 2 mm thick GI sheets continuously connected including horizontal and vertical bends, reducers, tees, and other accessories. All the cable tray accessories shall be factory pre-fabricated until otherwise specific approval obtained to fabricate at site.Tray shall be dully suspended from ceiling with suitable approved make anchor fasteners, vertical GI rods of 12mm dia /GI rigid angle supports etc or installed on suitable wall supported brackets as required complete as per specifications. b) All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded. c) Note: Trays shall be supported adequately at minimum 1 m distance from the building structure /ceiling/inside trench by means of galvanized (as specified) MS structural members secured to the structure by dash fasteners or by grouting. This support should be capable of withstanding the weight equivalent of 3m length of the cables that can be laid in the trays. At turns the support has to be double and at both ends of the bend. 3.5.1 450 mm wide x 50 mm deep cable tray Mtr 568.0 0.0 3.5.2 300 mm wide x 50 mm deep cable tray Mtr 1405.0 0.0 3.5.3 150 mm wide x 50mm deep cable tray Mtr 16240.0 0.0 3.6 Cable Trays -Ladder a) Supply and fixing pre-galvanized factory fabricated GI ladder type cable trays, hot dip galvanized, double bended cable tray from 2.5mm thick sheet steel continuously connected including inward,outward,horizontal & vertical bends,reducers,tees,flexible earth connector and other accessories. All the cable tray accessories shall be factory pre-fabricated, until otherwise specific approval is obtained to fabricate at site. b) All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded. c) Note: Trays shall be supported adequately at minimum 1 m distance from the building structure / ceiling/inside trench by means of galvanized (as specified) structural members secured to the structure by dash fasteners or by grouting. This support should be capable of withstanding the weight equivalent of 3m length of the cables that can be laid in the trays. At turns the support has to be double and at both ends of the bend. 3.6.1 600 mm wideRunners 20 x 75 x 20 x 2.5 mmRungs 20 x 30 x 20 x 2.5 mm 250 mm Centre to Centre (C/C) Mtr 4850.0 0.0 3.6.2 450 mm wideRunners 20 x 75 x 20 x 2.5 mmRungs 20 x 30 x 20 x 2.5 mm 250 mm Centre to Centre (C/C) Mtr 6370.0 0.0 3.6.3 300 mm wideRunners 20 x 75 x 20 x 2.5 mmRungs 20 x 30 x 20 x 2.5 mm 250 mm Centre to Centre (C/C) Mtr 3620.0 0.0 3.6.4 150 mm wideRunners 20 x 75 x 20 x 2.5 mmRungs 20 x 30 x 20 x 2.5 mm 250 mm Centre to Centre (C/C) Mtr 2180.0 0.0 3.7 Cable Trays cover Supply, fabrication and installation of hot dipped galvanised cable tray covers (as required by Engineer at site) made out of 2.0 mm thickness suitable for perforated & ladder trays including accessories like clamp, bolt nut etc.. Complete as per specifications, as required as below. 3.7.1 600 x 50 x 2 mm Mtr 100.0 0.0 3.7.2 450 x 50 x 2 mm Mtr 100.0 0.0 3.7.3 300 x 50 x 2 mm Mtr 100.0 0.0 3.7.4 150 x 50 x 2 mm Mtr 100.0 0.0 3.7.5 100 x 50 x 2 mm Mtr 100.0 0.0 3.8 Raceways in floor/Ceiling a) Supply, installation and testing of GI raceways made of pre-galvanised sheet metal with cover fabricated from 2.0 mm thick GI sheet with minimum coating thickness as per IS-277 on both sides with removable cover plate of 3mm thick, cover fitted on to the body with screws & can be opened easily if required. complete with counter sunk cadmium plated brass screws, bends, tee-junctions, cross junction etc. rendered electrically continuous as approved and of following sizes. b) All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded. c) Note: Raceway shall be supported adequately at minimum 1 m distance from the building structure / ceiling/inside trench by means of galvanized (as specified) MS structural members secured to the structure by dash fasteners or by grouting. This support should be capable of withstanding the weight equivalent of 3m length of the cables that can be laid in the raceway. At turns the support has to be double and at both ends of the bend. 3.8.1 200 mm wide & 50 mm deep Raceway Mtr 990.0 0.0 3.8.2 150 mm wide & 50 mm deep Raceway Mtr 350.0 0.0 3.8.3 100 mm wide & 50 mm deep Raceway Mtr 1480.0 0.0 3.9 GI SUPPORT FOR CABLE TRAY Design, Supply, fabrication and erection of Pre fabricated cable tray supports made out of Hot dip galvanized GI angle/channels/flats fabricated to the required size and shape falling in the category of standard GI section. Rate shall include cost of anchor fastener, clamps, bolt nuts with washer and other accessories required for installation of supports. All the welded part shall be grinded smoothly and panting to be done with suitable/matching paint. Kgs 51200.0 0.0 3.1 Junction boxes a) Supply, installation, testing & commissioning of floor junction boxes from 2mm thick GI with minimum coating thickness as per IS-277 on both sides with removable cover plate with 3mm thickness complete with counter sunk cadmium plated brass screws, bends etc. rendered electrically continuous as approved and of the following sizes:- b) All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded. 3.10.1 For 150*50 mm raceway Nos 102.0 0.0 3.10.2 For 200*50 mm raceway Nos 172.0 0.0 3.10.3 Supply and installation of floor boxes (200 * 180 * 180 mm) for mobile jacks to be buried in the workshop floor for mounting thesockets for electrical power supply to jacks consisting of 10 mm thick steel plate with hinged cover made of 8 mm thick chequered plate as per tender specifications Nos 68.0 0.0 3.10.4 Supply and installation of floor boxes (400 * 250 * 250 mm) for control panel of mobile jacks to be buried in the workshop floor for the sockets ft* electrical power supply to jacks consisting of 10 mm thick steel plate with hinged cover made of 8 mm thick chequered plate as per tender specifications Nos 42.0 0.0 J.04 CIRCUIT CUM POINT WIRING, SUBMAINS AND POWER OUTLETS General Whether explicitly stated in the schedules below or not, the following must be complied with:- a) For Supply and installation of conduits, GI metallic flexible conduits and wiring, relevant clauses of Technical Specifications must be followed. b) \\"Wires supplied must conform to relevant clauses of Technical Specifications\\". c) Wiring accessories must conform Technical Specifications. d) In case of any contradiction between BOQ and Technical specifications, the most stringent condition of the two will apply. e) All final connections specially to vibrating equipments shall be made through GI metallic flexible conduits. f) \\"All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded.\\" 4.1 Conduit for Circuit mains 4.1.1 Providing conduit embedment or surface laying on the roof slab / wall / structure including supply of heavy duty GI conduit pipe with minimum 20 micron thick galvanising along with all required GI conduit accessories like bends, elbows, junction boxes, PVC bushes for conduit ends, etc as per wiring specification. The conduit shall be installed and GI fish wire shall be provided along the conduit and terminated at all junction boxes as required wherever it is necessary. Surface laying conduit shall be used with spacer type saddle clamp with brass screw. Wherever required flexible conduits shall also be provided at locations like bends etc and its cost shall be built in the GI conduit only. a) 32mm dia, 1.6mm thick, GI conduit pipe for Lighting and Power circuits including conduit accessories and GI fish wire along the conduit and terminated at all junction boxes as required. Mtr 4100.0 0.0 b) 25mm dia, 1.6mm thick, GI conduit pipe for Lighting and Power circuits including conduit accessories and GI fish wire along the conduit and terminated at all junction boxes as required. Mtr 9200.0 0.0 4.2 Wiring for circuit mains 4.2.1 Supply and wiring for lighting in the existing conduit/raceway/tray for Lighting Circuits/ Single phase sockets from DB to first light/ switch/socket control box with 3Runs of (P + N +PE) copper FRLSZH, 1100 V grade cable to connect all lights, celing & exhaust fan, switches sockets etc. All wires,cables shall be terminated with suitable type lugs and provided with non erasable ferrules for identification. a) Single circuit consisting of 3 Run 2.5 sqmm Copper FRLSZH wire, 1100 V grade cable as per IS:694 Mtr 13250.0 0.0 b) Single circuit consisting of 2 Run 4.0 sqmm and 1x 2.5 Sqmm Copper FRLSZH wire, 1100 V grade cable as per IS:694 Mtr 13250.0 0.0 c) Single circuit consisting of 3C*2.5 sqmm Copper armoured FRLSZH cable, 1100 V grade cable (for sheds) as per IS:7098(part-1) & IEC-60502-1 Mtr 12900.0 0.0 d) Single circuit consisting of 3C*4 sqmm Copper armoured FRLSZH cable, 1100 V grade cable.(for sheds) as per IS7098(part-1) & IEC-60502-1 Mtr 22000.0 0.0 e) Single circuit consisting of 3C*2.5 sqmm Copper flexible FRLSZH cable, 1100 V grade cable as per IS 694 (from loop-in box to light fixture). Mtr 500.0 0.0 f) Single circuit consisting of 3C*4 sqmm Copper flexible FRLSZH cable, 1100 V grade cable as per IS 694 (from loop-in box to switch box) Mtr 500.0 0.0 4.3 Primary Points 4.3.1 Switch controlled Primary Points Supply, installation, testing & commissioning of 1.6 mm thick Modular GI box with cover plate, switches, sockets, Blank plate & laying of conduit and wiring from switch box to first light / Ceiling Fan/ Exhaust Fan / wall mount fan point/6A socket with 3 x 2.5 sq. mm(P+N+PE), 1100 Volt grade FRLSZH insulated copper conductor wires as per IS:694 in 1.6 mm thick GI conduit, surface run with GI saddles or concealed or in GI raceway including cost of cutting & filling chases for recessed conduiting and complete with GI junction boxes, pull boxes, inspection boxes, bends, flexible conduit & other accessories etc and earthing of switch boxes. 6A socket located within the switch box is not accounted as a point. (Lights, fans and 6 amps socket outlets may be wired on a common circuit and circuit shall not have more than ten points of light, fans and 6 amps sockets or a load of 800 watts whichever is less). a) First point controlled by one 6A switch up to 10 M length. Nos 502.0 0.0 b) First point controlled by one 6A switch more than 10M and up to 20 M length. Nos 140.0 0.0 c) First point controlled by one 6A switch above 20 M length and up to 40 M Nos 48.0 0.0 4.4 Secondary Points 4.4.1 Switch controlled Secondary light Points Supply & laying of conduit and wiring from first light / Ceiling Fan/ Exhaust Fan / wall mount fan point/6A socket to subsequent points with 3 x 2.5 sq. mm(P+N+PE), 1100 Volt grade FRLSZH insulated copper wires as per IS:694 in 1.6 mm thick GI conduit, surface run with GI saddles or concealed or in GI raceway including cost of cutting & filling chases for recessed conduiting and complete with GI junction boxes, pull boxes, inspection boxes, bends, flexible conduit & other accessories etc and earthing of switch boxes. Excluding the cost of switches/sockets and switch boxes(included in primary point) as below: a) Secondary or looping point controlled by one 6A switch up to 10 Meter length. Nos 1310.0 0.0 b) Secondary or looping points controlled by one 6A switch more than 10M and up to 20 Meter length. Nos 405.0 0.0 c) Secondary or looping point controlled by one 6A switch above 20 Meter length and up to 40 mtr Nos 98.0 0.0 4.4.2 Switch controlled Secondary power socket Points Supply & laying of conduit and wiring from first 16A / 20A socket, work station socket to subsequent points with 2x4 sqmm (P+N) & 1X2.5 sqmm(PE), 1100 Volt grade FRLSZH insulated copper wire as per IS:694 in 1.6 mm thick GI conduit, surface run with GI saddles or concealed or in GI raceway including cost of cutting & filling chases for recessed conduiting and complete with GI junction boxes, pull boxes, inspection boxes, bends & other accessories etc and earthing of switch boxes. Excluding the cost of switches/sockets and switch boxes(cost of switches, socket & back box will be paid separately) as below: a) Secondary or looping point controlled by one 16A switch up to 10 M length. Nos 198.0 0.0 b) Secondary or looping points controlled by one 16A switch more than 10M and up to 20 M length. Nos 201.0 0.0 c) Secondary or looping point controlled by one1 6A switch above 20 M length to 35 M length Nos 20.0 0.0 4.4.3 MCB controlled Secondary light Points Supply & laying of conduit and wiring from first light / Ceiling Fan/ Exhaust Fan / wall mount fan point/6A socket to subsequent points with 3Cx 2.5 sq. mm armoured, 1100 Volt grade FRLSZH copper conductor cable as per IS 7098(part-1) & IEC-60502-1 in 1.6mm thick GI conduit surface run with GI saddles or concealed or in Existing GI raceway/tray including cost of cutting & filling chases for recessed conduiting and complete with GI junction boxes, pull boxes, inspection boxes, bends, flexible conduit & other accessories etc and earthing of switch boxes. Excluding the cost of MCB/ switches/sockets and switch boxes as below. a) Secondary or looping point controlled by 10A MCB up to 10 M length. Nos 210.0 0.0 b) Secondary or looping point controlled by 10A MCB from 11 M to 20 M length. Nos 320.0 0.0 c) Secondary or looping point controlled by 10A MCB from 21 M to 30 M length. Nos 225.0 0.0 d) Secondary or looping point controlled by 10A MCB more than 30 M to 50 M Nos 580.0 0.0 4.4.4 MCB controlled Secondary power socket Points Supply & laying of conduit and wiring from first 16A / 20A socket to subsequent points with 3Cx4 sqmm armoured, 1100 Volt grade FRLSZH copper conductor cable as per IS 7098(part-1) & IEC-60502-1 in 1.6mm thick GI conduit, surface run with GI saddles or concealed or in Existing GI raceway/tray including cost of cutting & filling chases for recessed conduiting and complete with GI junction boxes, pull boxes, inspection boxes, bends & other accessories etc and earthling of switch boxes. Excluding the cost of MCB/switches/sockets and switch boxes as below: a) Secondary or looping point controlled by 16A switch/ 20A MCB up to 10 M length. Nos 69.0 0.0 b) Secondary or looping point controlled by 16A switch/ 20A MCB more than 10M and up to 20 M length. Nos 118.0 0.0 c) Secondary or looping point controlled by 16A switch/20 A MCB above 20 M length to 35 M. Nos 54.0 0.0 4.4.5 24 V SOCKET POINT WIRING Point wiring for 24V socket outlets (for Inspection pit) with 3C x 2.5 sqmm armoured (P+N+E) FRLSZH 1100V grade copper conductor cable as per IEC-60502-, in 1.6mm thick GI conduit surface run with GI saddles or concealed or in Existing GI raceway/tray including cost of cutting & filling chases for recessed conduiting and complete with GI junction boxes, pull boxes, inspection boxes, bends & other accessories etc and earthing of switch boxes. Excluding the cost of MCB/ switches/sockets and switch boxes Nos 72.0 0.0 4.4.6 CEILING FAN POINT WIRING \\"Point wiring for ceiling fan points with 3 x 2.5 sqmm (P+N+E) FRLSZH insulated 1100 volt grade flexible stranded copper conductor wires as per IS:694 in IS embossed 25mm dia GI recessed and/or surface conduiting system including cost of providing saddles/hanger etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of Supply and fixing modular flush mounted 240 volt 6 amp control switch and 240 volt 300 watt 5 Step electronic speed regulator of approved quality & colour housed in 1.6 mm thick zinc chromate passivated GI boxes with moulded cover plate and with interconnections complete as per specifications and as required.\\" Nos 248.0 0.0 4.4.7 EXHAUST FAN POINT WIRING Point wiring for exhaust fan 300 mm dia / 450 mm dia points with 1100 v grade 3C x 2.5 sqmm cable with copper conductor FRLSZH insulated armoured cable as per IEC-60502-1 OR 3 x 2.5 sqmm (P+N+E) FRLSZH insulated 1100 volt grade flexible stranded copper conductor wires as per IS:694 in IS embossed 25mm dia GI recessed / surface conduiting system. wiring including cost of providing GI bends, junction boxes, saddles, hanger etc for surface conduiting and cost of cutting, filling chases for recessed conduiting and including the cost of supply, fixing of modular flush mounted 240 volt 6 amp control switch in the existing GI box and including cost of Supply and fixing 240 volt 6 amp socket outlet near exhaust fan of approved quality & colour housed in 1.6mm thick zinc chromate passivated GI boxes with moulded cover plate and with inter connections complete as per specifications and as required. Nos 86.0 0.0 4.5 Modular Grid Plate Mounted Switch/es and Socket/s Supply & installation of following modular grid plate mounted switch/ (es) and socket/(s) etc. on a suitable size 1.6mm thick GI switch boxes complete in single or combination on prorate basis complete with the connections, earthing and testing as per specifications and as required: (Note the grid plate and GI BOX shall be selected suitably as per the requirement to fix the switches and sockets. Note: All modular switch, socket & GI box with front plate equivalent to Anchor roma plus. a) 6 Amp Universal socket with 6 amp modular switch having indication of ON/OFF with suitable GI box & front plate Nos 98.0 0.0 b) 6/16 Amps, Universal socket with 16 Amps, modular switch having indication of ON/OFF with suitable GI box and front plate. Nos 545.0 0.0 c) 3 nos of 6 amps 5 pin socket with 16 Amps modular switch having indication of ON/OFF with suitable GI box and front plate. Nos 165.0 0.0 4.6 Industrial socket outlet 4.6.1 20 Amps, 1-Phase Industrial Socket Outlet Supply, installation & testing of 20A ,1-Phase,3 pin, pre-wired(FRLSZH) industrial socket outlet with 20A SP MCB in a non-metallic enclosure with IP66 protection rating(Weather proof, Corrosion free, Halogen and silicon free, UV resistance, Insulated and shock proof, high impact strength, Flame retardant and Self extinguishing) with all mounting, fixing accessories & terminations, terminal blocks to connect netural,earth with plug top complete as required. Nos 180.0 0.0 4.6.2 32 Amps, 3-Phase Industrial Socket Outlet Supply, installation & testing of 32A ,3-Phase,5 pin, pre-wired(FRLSZH) industrial socket outlet with 32A TP MCB in a non-metallic enclosure with IP66 protection rating(Weather proof, Corrosion free, Halogen and silicon free, UV resistance, Insulated and shock proof, high impact strength, Flame retardant and Self extinguishing) with all mounting, fixing accessories & terminations, terminal block to connect netural,earth with plug top complete as required. Nos 28.0 0.0 4.6.3 63 Amps, 3- Phase Industrial Socket Outlet Supply, installation & testing of 63A ,3-Phase,5 pin, pre-wired(FRLSZH) industrial socket outlet with 63A TP MCB in a non-metallic enclosure with IP66 protection rating(Weather proof, Corrosion free, Halogen and silicon free, UV resistance, Insulated and shock proof, high impact strength, Flame retardant and Self extinguishing) with all mounting, fixing accessories & terminations, terminal block to connect netural,earth with plug top complete as required. Nos 18.0 0.0 4.6.4 16 Amps, 1-phase industrial socket outlet (Inside inspection / cleaning pit) Supply, installation & testing of 16A ,1-Phase,3 pin, pre-wired industrial socket outlet with 16A SP MCB in a non-metallic enclosure with IP66 protection rating(Weather proof, Corrosion free, Halogen and silicon free, UV resistance, Insulated and shock proof, high impact strength, Flame retardant and Self extinguishing) with all mounting, fixing accessories & terminations, terminal block to connect netural,earth with plug top complete as required. Nos 105.0 0.0 4.6.5 16 Amps, 1-phase industrial socket outlet for 24 V socket inside pit Supply, installation & testing of 16A ,1-Phase,3 pin, pre-wired industrial socket outlet with 16A SP MCB in a non-metallic enclosure with IP66 protection rating(Weather proof, Corrosion free, Halogen and silicon free, UV resistance, Insulated and shock proof, high impact strength, Flame retardant and Self extinguishing) with all mounting, fixing accessories & terminations, terminal block to connect netural,earth with plug top complete as required. Nos 72.0 0.0 4.7 ENCLOSURE/ISOLATOR BOX 4.7.1 Supply, installation, testing and commissioning of 32A, 25 kA, FP MCCB with 300mA Earth fault and earth leakage device & 10A, DP MCB with powder coated CRCA Steel Sheet of 2mm. thick surface/recessed box with the total unit having IP 54 with suitable gland plate for incoming & outgoing cables, indication lamps(R,Y,B,ON,OFF & Trip) etc & others complete as required. Nos 5.0 0.0 4.7.2 Supply, installation, testing and commissioning of 63A, 25 KA FP MCCB with 300mA Earth fault and earth leakage device & 10A, DP MCB with powder coated CRCA Steel Sheet of 2mm. thick surface/recessed box with the total unit having IP 54 with suitable gland plate for incoming & outgoing cables, indication lamps(R,Y,B,ON,OFF & Trip) etc & others complete as required. Nos 30.0 0.0 4.7.3 Supply, installation, testing and commissioning of 125/100 A, 25 KA, FP MCCB with 300mA Earth fault and earth leakage device & 10A, DP MCB with powder coated CRCA Steel Sheet of 2mm. thick surface/recessed box with the total unit having IP 54 with suitable gland plate for incoming & outgoing cables, indication lamps(R,Y,B,ON,OFF & Trip) etc & others complete as required. Nos 6.0 0.0 4.7.4 Supply, installation, testing and commissioning of 160 A, 25 KA, FP MCCB with 300mA Earth fault and earth leakage device & 10A, DP MCB with powder coated CRCA Steel Sheet of 2mm. thick surface/recessed box with the total unit having IP 54 with suitable gland plate for incoming & outgoing cables, indication lamps(R,Y,B,ON,OFF & Trip) etc & others complete as required. Nos 3.0 0.0 4.7.5 Supply, installation, testing and commissioning of 200A, 25 KA, FP MCCB with 300mA Earth fault and earth leakage device & 10A, DP MCB with powder coated CRCA Steel Sheet of 2mm. thick surface/recessed box with the total unit having IP 54 with suitable gland plate for incoming & outgoing cables, indication lamps(R,Y,B,ON,OFF & Trip) etc & others complete as required. Nos 3.0 0.0 4.7.6 Supply, installation, testing and commissioning of 250A, 25 KA, FP MCCB with 300mA Earth fault and earth leakage device & 10A, DP MCB with powder coated CRCA Steel Sheet of 2mm. thick surface/recessed box with the total unit having IP 54 with suitable gland plate for incoming & outgoing cables, indication lamps(R,Y,B,ON,OFF & Trip) etc & others complete as required. Nos 8.0 0.0 4.8 LOOP-IN & LOOP OUT BOX Loop in, loop-out junction box in a non-metallic enclosure with weather proof, corrosion free, halogen free & silicon free, UV resistance, insulated & shock proof, high impact strength, flame retardant suitable for termination of 2 nos of 3C*2.5/3C*4 sqmm cu.armoured cable & 1 nos of 3C*2.5/3C*4 sqmm flexible cable including termination with required double compression glands & suitable lugs. Nos 1500.0 0.0 4.9 STEP DOWN TRANSFORMER Supply, installation, testing and commissioning of following step down transformer in 1.6 mm thick GI enclosure of approved make and desired input voltage 220 volts ± 10% and output voltage of 24 volts with tapping of 26 volts, 28 volts and 30 volts with provision to terminate 3C*2.5 sqmm Cu.armoured cable a) 2.0 KVA Nos 6.0 0.0 4.1 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. Each 62.0 0.0 4.11 PUSH BUTTON STATION a) Metallic enclosure with IP-66 protection with stainless screws for emergency stop, push button with shrouded emergency 40mm twist key release button and ON,OFF push button in the same box. Nos 10.0 0.0 J.05 INDOOR,OUTDOOR LIGHTING, FANS, HIGHMAST & STREET LIGHT POLES General a) \\"The Lighting System specified herein, must conform to the technical Specifications, in addition to the description given in respective items of BOQ, whether explicitly specified or not. In case of contradiction between specifications and description in BOQ, the most stringent of the condition will prevail.\\" b) Supply, installation, testing & commissioning of light fittings including all accessories e.g. ballast, HPF condensors, lamps, holders, surface/recess mounting arrangement etc. including necessary supports, accessories and hardware as per specifications & as required at site and as below:- c) Luminaires should operate at +/ 10% voltage fluctuation for continuous use to comply to IEC. d) All the components including the internal wiring of the luminaries to be used shall be manufactured of material, which are of low smoke and zero halogen type. All luminaires shall be manufactured to relevant sections of IEC60598 or other approved international standards and the type tests for all luminaries shall be provided. e) All internal wiring within the lighting fixtures shall be heat-resisting cables. f) Note: Lamp/LED/LED DRIVERS should have free replacement for one year from the date of Installation. The Date of installation shall be from the date of handing over the work to Engineer / Employer. g) All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded. 5.1 Indoor Light Fixtures 5.1.1 Supply, installation, testing and commissioning of surface mounted LED Downlighter, made of polycarbonate housing with PC diffuser. Luminaire should be with minimum system efficacy of 100 Lumen/Watt and minimum system lumen output of 1600 maintained at 70% at the end of 30,000 burning hours.Similar To Philips Sleek Surface LED downlighter SM251C LED16S-6500 PSU WH or approved equivalent Make. Nos. 120.0 0.0 5.1.2 Supply, installation, testing and commissioning of surface mounted LED Downlighter, made of polycarbonate housing with PC diffuser. Luminaire should be with minimum system efficacy of 110Lumen/Watt and minimum system lumen output of 2000 maintained at 70% at the end of 30,000 burning hours. Similar To Philips Sleek Surface LED downlighter SM251C LED20S-6500 PSU WH or approved equivalent Make. Nos. 565.0 0.0 5.1.3 Supply, installation, testing and commissioning of surface/suspended 1195X147x50 mm LED Luminaire, made up of CRCA housing with high efficiency diffuser. Luminaire should be with minimum system efficacy of 90 Lumen/Watt and minimum system lumen output of 2900lm maintained at 70% at the end of 50,000 burning hours. Similar To Philips Smartbrite surface SM270C LED 30S 6500 PSU WH or approved equivalent Make. Nos 675.0 0.0 5.1.4 Supply, installation, testing and commissioning of recessed mounted LED Downlighter, made of pressure die-cast aluminium body with high quality diffuser. Luminaire should be with minimum system efficacy of 92Lumen/Watt and minimum system lumen output of 600 maintained at 70% at the end of 50,000 burning hours.Similar To Philips Green Perform LED downlighter DN 391B LED6S-6500 PSU WH or approved equivalent Make. Nos 4.0 0.0 5.1.5 Supply, installation, testing and commissioning of recessed mounted LED Downlighter, made of pressure die-cast aluminium body with high quality diffuser. Luminaire should be with minimum system efficacy of 95Lumen/Watt and minimum system lumen output of 1000 maintained at 70% at the end of 50,000 burning hours. Similar To Philips Green Perform LED downlighter DN 392B LED10S-6500 PSU WH or approved equivalent Make. Nos 10.0 0.0 5.1.6 Supply ,installation, testing and commissioning of recessed mounted LED Downlighter, made of pressure die-cast aluminium body with high quality diffuser. Luminaire should be with minimum system efficacy of 100Lumen/Watt and minimum system lumen output of 2200 maintained at 70% at the end of 50,000 burning hours. Similar To Philips Green Perform LED downlighter DN 395B LED20S-6500 PSU WH or approved equivalent Make. Nos 10.0 0.0 5.1.7 Supply, Installation, Testing & Commissioning of LED 2X2 recess mounting LED luminaries with soft opal diffuser provides high visual comfort enclosed in a polyester powder coated housing with high efficiency diffuser. It should be system lumen efficacy 125Lumen/Watt with system level luminous flux of 3600 lumens and 50,000 hours burning hours Similar to Philips Full Glow RC380B LED36S 6500 G5 L60W60 PSU OD or equivalent make. Nos 180.0 0.0 5.1.8 Supply, installation, testing and commissioning of suspended high bay LED Luminaire, made up of high pressure die cast aluminium with tempered glass cover. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Luminaire should be with minimum system efficacy of 125Lumen/Watt and minimum system lumen output of 10000 maintained at 70% at the end of 50,000 burning hours with wide beam light distribution. The luminaire shall be IP 66 & IK 08 protection Similar To Philips Durabay - BY325P LED 100S CW PSE FG WB or approved equivalent Make. Nos 245.0 0.0 5.1.9 Supply, installation, testing and commissioning of suspended high bay LED Luminaire Similar To Philips Durabay - BY325P LED160S CW PSU GR FG WB XTFCL V1 or approved equivalent Make., made up of high pressure die cast aluminium with tempered glass cover. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed.Luminaire should be with minimum system efficacy of 125Lumen/Watt and minimum system lumen output of 16500 maintained at 70% at the end of 50,000 burning hours with wide beam light distribution. Nos 320.0 0.0 5.1.10 Supply, installation, testing and commissioning of surface or suspended LED Batten Luminaire, made up of CRCA sheet with glossy PC diffuser. Luminaire should be with minimum system efficacy of 120Lumen/Watt and minimum system lumen output of 2000 maintained at 70% at the end of 50,000 burning hours. TSimilar To Philips Endura LED Batten BN308C LED20S-6500 L120 PSU WH or approved equivalent Make. Nos 19.0 0.0 5.1.11 Supply, installation, testing and commissioning of surface/Conduit LED Batten Luminaire, made up of CRCA sheet with glossy PC diffuser. Luminaire should be with minimum system efficacy of 120Lumen/Watt and minimum system lumen output of 4000 maintained at 70% at the end of 50,000 burning hours. Similar To Philips Endura LED Batten BN308C LED40S-6500 L120 PSU WH or approved equivalent Make. Nos 1102.0 0.0 5.1.12 Supply, installation, testing and commissioning of surface/wall dust and waterproof LED Batten Luminaire, made up of UV Shielding PC housing with PC diffuser. Luminaire should be with minimum system efficacy of 120Lumen/Watt and minimum system lumen output of 2400 maintained at 70% at the end of 50,000 burning hours. Similar To Philips Smartbrite Waterproof Batten WT201C LED24S-6500 PSU L120 S2 or approved equivalent Make. Nos 32.0 0.0 5.1.13 Supply, installation, testing and commissioning of surface/wall dust and waterproof LED Batten Luminaire, made up of UV Shielding PC housing with PC diffuser. Luminaire should be with minimum system efficacy of 120Lumen/Watt and minimum system lumen output of 4400 maintained at 70% at the end of 50,000 burning hours.Similar To Philips Smartbrite Waterproof Batten WT201C LED44S-6500 PSU L120 S2 or approved equivalent Make. Nos 58.0 0.0 5.1.14 Supply, installation, testing and commissioning of LED pit light, equivalent to 36W surface mounted-similar to SCHREDER MY1/LED Nos 290.0 0.0 5.1.15 Supply, installation, testing and commissioning of LED bulk head luminaire equivalent to Philips model no: WT202W LED6S CW PSU S3 PC 700lm 6W Nos 48.0 0.0 5.2 OUTDOOR Light fixture 0.0 5.2.1 Supply, installation, testing and commissioning of LED street light with SMD type LED cool white Lighting Fixture of Light output ratio of 100.02%, Lamp luminous flux of 10977 lumen, luminary luminous flux of 10980lm, luminous efficiency 104.5 lm/watt, power 105.1 w, made up of LM 6 Pressure Die cast aluminium housing with corrosion resistant painting confirming to IP 66 , Impact resistance > = IK07 standards, separate compartment for LEDs & electronic driver, Power factor-> 0.95, Operating voltage 120-277 volt universal electronic potted driver with Surge Protection of 4KV internal and 10KV External SPD version, CRI >70, Total Harmonic Distortion < 10 % , Lumen maintenance ( L 70 ) 50,000 hr (considering 35 degree average night temperature). The wattage of each LED should be greater than 1 watt and less than 3 Watt. Similar to Street light BRP410 LED 110 CW HE MR FG of Philips make or equivalent. Nos 62.0 0.0 5.2.2 Supply, installation, testing and commissioning of LED street light with SMD type LED cool white Lighting Fixture made up of LM 6 Pressure Die cast aluminium housing with corrosion resistant painting confirming to IP 66 , Impact resistance > = IK07 standards, separate compartment for LEDs & electronic driver, Power factor-> 0.95, Operating voltage 140-270 volt universal electronic potted driver with Surge Protection of 4KV, CRI >70, Total Harmonic Distortion < 10 % , Lumen maintenance ( L 70 ) 50,000 hr (considering 35 degree average night temperature). The wattage of each LED should be greater than 1 watt and less than 3 Watt. similat to Eav – 8lx. Similar to Philips BRP046 LED 36 CW MR S1 PSU GR or equivalent Nos 4.0 0.0 5.2.3 Supply, installation, testing and commissioning of LED street light with SMD type LED cool white Lighting Fixture Light output ratio of 99.97%, Lamp luminous flux of 7084 lumen, luminary luminous flux of 7082 lm, luminous efficiency 103.1 lm/watt, power 68.7 1 w made up of LM 6 Pressure Die cast aluminium housing with corrosion resistant painting confirming to IP 66 , Impact resistance > = IK08 standards, separate compartment for LEDs & electronic driver, Power factor-> 0.95, Operating voltage 120-270 volt universal electronic potted driver with internal Surge Protection of 4KV, CRI >70, Total Harmonic Distortion < 10 % , Lumen maintenance ( L 70 ) 50,000 hr (considering 35 degree average night temperature). The wattage of each LED should be greater than 1 watt and less than 3 Watt.similat to Pole height 7m, Eav – 8lx. Similar to Philips BRP410 LED CW 072 MR FG S1 PSU or equivalent Nos 9.0 0.0 5.2.4 Supply, installation, testing & commissioning of LED gate with required accessories light equivalent to Philips model no Uniurban 33W 3000lm BDP461 LED33 NW 110-277V Nos 6.0 0.0 5.2.5 Supply, installation, testing & commissioning of LED Bollard with required junction box for cable termination, foundation, required accessories. light equivalent to Philips model no City Cube Bollard 17W 900lm BCP400 LED09 D CW PSU GR S1 Nos 18.0 0.0 5.2.6 Supply, installation, testing & commissioning of LED flood light with all required accessories equivalent to Philips model no: BVP192 LED82 CW HO NB FG GR PSU 8200lm 75W Nos 2.0 0.0 5.2.7 Supply, installation, testing & commissioning of Beacon lights Nos 18.0 0.0 5.3 Ceiling Fan 1200 mm Sweep 0.0 Supply, installation, testing & commissioning of Ceiling Fan 1200 mm sweep with out regulator but with all accessories like down rods, cover plate, cups as per IS: 374, 1979 with all amendments as applicable as required. Nos 248.0 0.0 5.4 High mast Lighting Nos 9.0 0.0 Supply, installation, testing and commissioning of motorised 30 meter high mast system with foundation and its accessories. Mast shaft shall be in three sections, hot dip galvanised and suitable for wind velocity as per IS 875. It shall also include accessories for high mast including head frame, steel wire rope 6 mm dia (7/19 construction), trailing cable, double drum winch, galvanised Lantern carriage arrangement suitable for 16 luminaires symmetrically & its control gear boxes and lightning finial. The mast shall have an External power tool installed inside the base compartment for its operation both motorised & manual and including following but not limited to a) Foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates. b) Supply installation Testing and commissioining of suitable twin dome neon Aviation lights as required. c) 16 no's of 156 W LED luminaries with die cast/extruded aluminium body, pre anodized aluminium asymmetric/symmetric reflector,IP-65 and above heavy duty control gear housed in a weather proof housing equivalent to Philips cat no: BVP 483 LED 185 CW SWB PSU GR . d) Control panel housing 63 amps TPN MCB incomer, single dial timer contactor circuit for the automatic control of luminaires & other accessories as required along with following as required for complete functionality of the system. e) Common power tool for the operation of the mast with single phase, single speed motor along with reversing gear, stand, control push button and other accessories. f) Earth Station of Pipe earthing as pes IS.3043-1987 & IEEE:80-2013, including duplicate earth connection to the mast with 25x3 mm size GI Strip. g) Lightening arrester with air terminal, down conductors including maintenance free earth pit with chamber and all associated accessories. h) suitable foundation for the mast considering soil bearing capacity 10 ton per sqm, with base pedestal of approve design, incorporating a suitable cable looping box with terminal blocks MCB etc. i) All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded for complete supply, installations and commissioning of High Mast 5.5 Street Light Poles a) Supply, installation, testing and commissioning of the following street lighting fixtures with acrylic cover including fixing arrangement and with all accessories and lamps. b) Each pole should have cable pull-out hole of 15mm at every 500mm starting from 4 mtr to 6 mtr for monitoring other accessories. Pole switch should also have a terminal box of 75mm wide and 210 mm long for accommodating ELV services connector etc. c) 1:3:6 concrete foundation and pedestal as per specification and relevant IS and as required. Contractor to obtain approval of foundation design before proceeding further. e) Wiring to luminaries from 2A MCB with 3x2.5 sqmm copper, stranded conductor (P+N+PE) double sheathed wire and making connection & earthing of pole. f) 6 way, 20A connector & 6A MCB mounted on 6mm thick painted GI plate, insulated and accommodated inside the pole with gasketed weather. Vermin proof, hinged lockable covered GI box or integral cast box in pedestal as required along with 35 mm PVC pipes for cable entries. g) Luminaries as specified with lamps, necessary cross arms to the luminaries, integral control gear and as under h) All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded for complete supply, installations and commissioning of street lights 5.5.1 9 mtr hot dip galvanized octagonal with single overhang arm & with foundation bolts, base plate complete with foundation, entry & exit pipes control JB with connector generally as per specification. Nos. 62.0 0.0 5.5.2 7 mtr hot dip galvanized octagonal with single overhang arm & with foundation bolts, base plate complete with foundation, entry & exit pipes control JB with connector generally as per specification. Nos. 18.0 0.0 J.06 PROTECTIVE EARTHING & LIGHTNING PROTECTION SYSTEM 6.0 MAINTENANCE FREE EARTHING 6.1 Maintenance free earthing- Nos 44.0 0.0 Supply, installation and testing of copper bonded (17mmX 3Mtr) electrode in 150mm dia hole chemical earth pit with morbonite hygroscopic conductive compound + soil conditioning gel including chamber with cover confirming to IS 3043,BS 7430, IEEE-80 & IEC 62561. 6.2 EARTHING STRIPS & CABLES Supply, Laying, fixing, testing and commissioning of following strips for interconnecting the earthing stations, panels, DBs, Cable trays, etc. of the following sizes in built up trenches/ surface/ wall/ ground complete with holes & fixing, jointing/terminating accessories as per specifications as required. (Quantity shall be paid as per the actual measurement as executed) however direct measurement shall not exceed the quantity indicated in drawing approved by engineer. 6.2.1 50 mm x 6 mm GI strip Mtr 1750.0 0.0 6.2.2 25 mm X 6 mm GI strip Mtr 2550.0 0.0 6.2.3 50 mm x 6 mm Cu strip Mtr 615.0 0.0 6.2.4 8 SWG Cu WIRE Mtr 498.0 0.0 6.2.5 1Cx4 sqmm multistrand FRZH green cable conforming to IS 694 Mtr 498.0 0.0 6.2.6 70 Sqmm single core zero halogen Copper cable for clean earthing (green colour) as per IS 7098 & IEC-60502-1 Mtr 198.0 0.0 Note-1: In case of non availability of any of the sizes mentioned above, next higher size available in market shall be provided at the same rate. 6.3 Supply. Installation of GI/CU main earth terminal points including DMC/SMC insulator, anchor fastener, nut, bolts, etc as required. Necessary fixing arrangement like holes of suitable dia and number of holes with nut, bolt spring lock washer for termination of GI/CU strip shall be provided. 6.3.1 250mmx50x6 mm thick GI Nos 28.0 0.0 6.3.2 500mmx50x6 mm thick GI Nos 18.0 0.0 6.3.3 250mmx50x6 mm thick Cu Nos 12.0 0.0 6.4 Lightning Conductor Finials Nos 22.0 0.0 Lightning protection system should be based on IEC 62305 Supply and fixing Lightning Conductor Finials made of 25 mm dia 1.2mtr long copper tube having a single prong at the top with 85 mm dia 6 mm thick copper base plate, fixing accessories and clamping with down conductor as per specifications complete as required. 6.5 Galvanised horizontal & Vertical Conductor 6.5.1 Supply and installation of GI strip down conductor size 25x6 on surface/wall/parapet//shaft/buried at suitable depth with complete with joints (riveting/bolting/welding) bimetallic connector, testing links & other fixing accessories like DMC/SMC insulator, anchor fastener etc. And clamping/connection with earth termination as per specification & drawing as required. Mtr 5800.0 0.0 6.5.2 Supply and installation of GI strip down conductor size 25x6 buried at suitable depth with PVC tape complete with joints (riveting/bolting/welding) bimetallic connector, etc. And clamping/connection with earth termination as per specification & drawing as required. Mtr 852.0 0.0 6.6 Testing Joints Supply and fixing of the testing joints made of 25 mm x 6 mm thick GI strip 125 mm long with 4 Nos. GI bolts, nuts, check nuts and spring washers, insulators complete as required. Nos 24.0 0.0 6.7 Maintenance free earthing- Nos 24.0 0.0 Supply, installation and testing of copper bonded (25mmX 3Mtr) electrode in 150mm dia hole chemical earth pit with morbonite hygroscopic conductive compound + soil conditioning gel including chamber with cover confirming to IS 3043,BS 7430,IEEE-80 & IEC 62561 6.8 Air Craft Warning Lights Nos 4.0 0.0 Supply, installation, testing & commissioning of air craft warning lights complete with non flickering type lights similar to GEC model ZH 752 or WIPRO model no. WAN 20001 or equivalent including lamps, mounting bracket, earthing, painting complete with accessories to automatically switch off lights. (Point wiring shall be done under subhead conduit wiring). J.07 UNINTERRUPTED POWER SUPPLY SYSTEM 7.0 Supply, Installation, Testing and Commissioning of following rating online, Modular UPS system suitable for providing power Design, supply to emergency lighting and Computerised Control panel load of approved make, suitable for incoming 415 volts, 3 phase +10 % - 20%, 50 Hz, Design, supply and three phase output voltage, variation ± 1%, including isolation transformer, rectifier/dual converter, static switch, inverter, filter, Bypass & static transfer switch for automatic switch over without giving any break of power, maintenance bypass switch, Micro processor/ software controlled annunciation, protection(including against input phase reversal), and menu run diagnostic module, associated cabling and connections/ terminations, erection etc. complete as per specifications and as required. The price shall include provision of suitable terminal block including gland plate for termination of incoming, outgoing cables and supply of copper synchronizing bus.RS RJ-45 port shall be provided for monitoring various parameter of UPS on BMS work station through MODBUS protocol as per technical specification. a) DSP controlled advanced digital technology, IGBT based rectifier for reducing input THDi to <3%,active power factor correction > 0.99, inbuilt isolation transformer, very high crest factor of 3:1,overload capability of 150 % for 1 minute, very high reliability, manual bypass circuit with static switches and load side isolation facility for each parallel path, compact and modular design b) The unit shall be provided with isolator for incoming & outgoing. Unit shall be 100% load tested for performance and endurance as part of commissioning test at site. c) All internal wiring to be done with FRLSZH wires d) All the items not specifically mentioned here but necessary to make the system complete and suitable for desired application & operation as per Technical Specifications and Drawings will be deemed to be included in the quoted prices 7.1 20 KVA UPS (PR System) Set 3.0 0.0 a) Supply, Installation, Testing and Commissioning of 2V SMF VRLA lead acid sealed maintenance free battery (Design Life - 10years) suitable for 30 Minuts backup to the UPS set. Battery shall comply with relevant regulations & Battery racks shall be made of acid resistant material. 7.2 2 X 20KVA UPS (PR System) Set 1.0 0.0 a) Supply, Installation, Testing and Commissioning of 2V SMF VRLA lead acid sealed maintenance free battery (Design Life - 10years) suitable for 30 Minutes backup to the UPS set. Battery shall comply with relevant regulations & Battery racks shall be made of acid resistant material. (20KVA UPS) J.08 DG SET WITH PLC BASED AMF PANEL General 8.0 Supplying, installation, testing & commissioning of Radiator Cooled, silent type Diesel Generating Set comprising of multi-cylinder diesel oil engine with radiator, fly wheel, exhaust piping up to silencer and outside the remote location, residential type silencer, electric starting equipments, batteries, battery charger, directly coupled to an alternator of suitable capacity at 0.8 P.F. 3 phase, 4 wire 50 Hz 415 volts, A.C Design, supply complete with base plate antivibration mountings foundations for installation of D.G. Set, terminating arrangement for outgoing cables, control panel, controlling MCCB etc, complete of exhaust pipe installation with support arrangement as required as per specifications, Drawings and specified ambient conditions a) DG Sets shall be suitable for Auto Start, Auto Stop and Auto Load Management. b) The DG set in sound attenuated enclosure shall be mounted on a fabricated rigid common base frame with resilient anti-vibration mounting including associated foundation/masonry work(if required) to provide 98% vibration isolation efficiency. The DG sets shall include all accessories, fittings, instrument etc complete as per specification & as required. DG sets design temp will be 50 deg C c) Unloading, erection on the prepared plinth in the DG house, complete with all accessories and services, carry-out pre-commissioning checks, no-load testing, commissioning, load testing at different load condition (at factory & site),testing for AMF logic requirement and conducting performance tests to the fullest satisfaction of client in accordance with technical specification for electrical works of Engineer / Employer. The price shall include periodic checks like A,B,C, etc till the time of handing over. The sets shall be comprising of the following:- d) All the items not specifically mentioned here but necessary to make the system complete and suitable for desired application as per Technical Specifications and Drawings will be deemed to be included in the quoted prices e) Engine with all auxiliaries coupled with alternator complete with AVR & accessories. f) Electrical control panel with breaker/isolator including AMF facility. g) Starting battery, battery cable, engine driven battery charging, alternator, including stand alone mains powered battery float charger complete with relays, controls & indicators. h) Auxiliary control panel with relays, electronic modules to full fill all the logic requirement of auto start-stop, change over, engine & alternator protection and alarm system. i) Complete fuel service arrangement with main tank/990 litres day tank & fuel transfer system with level controller. j) Common drain pipe connecting the DG sets for draining off refused lubricating oils, spillages, etc to soak pit to be provided. k) Acoustic housing fabricated from high quality steel sheet of minimum 2mm thickness finished with powder coating shall be of weather proof construction designed to reduce noise level to maximum 75db at 1mtr distance from the equipment and suitable for thermal and noise level insulation as per relevant code of practices and technical specification enclosed. l) Supply of suitable rubber mats in front and back of DG control panel ( AMF panel), isolation panel as per latest standards (IS:15652:2006) ammended upto date. m) Power Cabling / Control cabling & wiring, its termination inside the DG set from atternator to the DG isolation panel if any will be part of the DG set supplier / contractor ( no separate measurements will be made). n) Power Cables from the DG isolation Panel to the DG power Panel ( in scope of E&M contractor) shall be supplied and laid by E&M contractor. Necessary interfacing for the same with E&M contractor shall be done by DG set suplier / contractor for evacuation of 100 % of output power . Nothing extra shall be payable for the same. However, control cabling from DG set and its load management cum synchronising Panel with DG Power panel shall be in the scope of DG set suppliuer / contractor. 8.1 625 KVA D.G. SET (INCLUDING PLC BASED AMF PANEL) Supply, erection, testing and commissioning of floor mounted totally enclosed sheet steel AMF Panel with PLC suitable for automatic operation of 625 kVA DG set and equipped with automatic gas flooding using linear heat sensing tube type fire trace system or equivalent. The panel shall be suitable for 415 V, 3 phase, 4 wire system, Copper bus bars designation labels as per requirement, continuous earth bus, cable clamping supports, panel illuminating lamps, cable gland plates for incoming and outgoing feeders as per details below: Following Electrical protection is required in DG and AMF Panel must be protected with ANSI- 32R, 81L,59,27,81R,59N. Set 1.0 0.0 Note: Original manufacturer certificate shall be provided to Engineer / Employer for Alternator and Engine.The DG shall be as per the latest CPCB noms. A INCOMING a) 2 nos. 1000 A, 50 KA, 4-pole ACB with microprocessor based over load and short circuit protection with time delay and earth fault IDMT release - all site settable B OUTGOING a) 1 nos. 1000 A, 50 KA, 4-pole ACB with microprocessor based over load and short circuit protection with time delay and earth fault IDMT release - all site settable C 2 Nos., 230V, AC operated integrated type Digital Multi function meter for measuring Frequency, Amperes ,Voltage, Energy & Power factor of approved makes conforming to specifications, latest IEC/ EMC and EMI standards, with necessary Circuit MCBs and suitable size CTs for above two incomer metering supporting SCADA / BMS connectivity D Battery charger consisting of : i Transformer/Rectifier ii DC. Ammeter iii DC. Voltmeter iv Charging rate selector switch (OFF/Trickle/Boost.) v One Mains supply Voltage monitor E DC Control relays incorporating engine Start/Stop, three attempts starting facility and failure to start lock out. F Auxiliary relays for automatic closing and opening of the alternator contactor for automatic operation as required. i Potential free contacts for BMS ii Selector switch Auto/Manual/ Test G Set of the following : i One Selector switch for engine control OFF/ON ii Four Push buttons, Start, Stop, Reset, Test. iii Two Indicating lamps \\"Load on set\\" \\"Load on Mains\\". iv Indication on annunciator for shutdown for \\"Low lube oil pressure\\", \\"High water Temperature\\", \\"overspeed\\", \\"low fuel\\" & \\"set fails to starts\\". v One no. counter to indicate number of times set has operated. vi One no. Hour meter to indicate the number of hours set has operated vii The AMF panel shall include necessary FRLSZH internal wiring, control circuit fuses, labelling, name plates cable identity tags on both ends etc. complete as per specification and as required viii Power Pack for the PLC backup of the DG set with all arrangement, including battery, Control Circuits, Internal wiring, labelling, name plates cable identity tags on both ends etc. complete as per specification and as required ix AMF panel details will be overruled by drawing/BOQ whichever is more stringent. 8.1.1 FUEL SYSTEM a) Design, supplying, installation, testing and commissioning of heavy duty Hand cranking oil pump with 3 mtr. Long flexible oil hose. Nos 1.0 0.0 b) Design, supplying, installation, testing and commissioning of 990 Day Oil fuel steel tank of under mentioned capacities made out of 5 mm thick M.S. sheet with float valve and low level alarm arrangement including fuel oil piping up to the set valves etc. complete as required. Nos 1.0 0.0 c) Design, supplying, installation, testing and commissioning of Suitable rating Fuel Oil pump including foundations, piping, valves, indications, safety devices etc. complete as required. Nos 2.0 0.0 d) MS C class 25mm fuel pipe lum 1.0 0.0 The Contractor scope of inspection and approval for getting the layout drawing, installation, license from Electrical Inspectorate local authority, explosive department, HERC for Campus complete as required for satisfactory function of the installation of above DG Sets 8.1.2 EXHAUST PIPING a) Design, supply, installation, testing & commissioning of exhaust piping of class 'B' MS(4.85mm thick as per IS 1239) of suitable size as recommended by the engine manufacturer including the cost of pipe support, bends, flexible joints and insulation etc complete as per tender specifications. The length will be measured beyond the exhaust silencer of the engine. The extended exhaust piping to collect & expel exhaust gases from engine cylinders, for the DG set, including turbo charger, flexible connectors, thermal insulated asbestos lagging with chicken mesh, & aluminium cladding, elbows, horizontal/vertical pipe supports, thimble with spray shield/rain cap etc. Height of stack and other factor shall be as per standards of CPCB & KSPCB norms. Soot sample collection facility for analysis/testing purpose to be provided. 8.1.3 For 625 KVA DG set Mtr 20.0 0.0 The contractor shall submit back-pressure calculations in support of exhaust pipe size for each DG Set. 8.1.4 Supply, installation and fixing of hot air exhaust duct of 22 SWG GI sheet with DG canopy to remove hot air with square mesh (20mm) cover at one end. sqmtr 10.0 0.0 J.09 ADDITION / DELETION ITEMS 9.1 3200 Amps, 415 V, 50 kA, 4 Pole, ACB No 1.0 0.0 a) 3200 amps Four pole electrically operated (motorised) fully draw out type air circuit breaker (minimum 50 kA) with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting. and with the following accessories : i 3 nos. cast resin current transformers of 3200/5 ratio with 15 VA Burden and Class 0.5 with MFM with Voltage, Current, Energy, Power Factor, KVAr, with communication port RJ-45 etc. ii 3 nos. cast resin current transformers of 3200/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch iii 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs iv 1- set Red/Green ON/OFF indicating lamps v 1- set of three phase (red, yellow, blue) indicating lamps vi Amber healthy/ trip indicating lamps vii 3 nos. cast resin current transformers of 3200/5 ratio with 15 VA Burden & Class 5P10 for protection. viii 230 V AC shunt trip coil ix 230 V, AC Motor wound spring closing mechanism x Terminals to receive copper sandwich bus duct xi TNC Switch xii Auto/local/remote selector switch key operated 9.2 2000 Amps, 415 V, 50 kA, 4 Pole, ACB No 1.0 0.0 a) 2000 amps Four pole electrically operated (motorised) fully draw out type air circuit breaker (minimum 50 kA) with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting. and with the following accessories : i 3 nos. cast resin current transformers of 2000/5 ratio with 15 VA Burden and Class 0.5 with MFM with Voltage, Current, Energy, Power Factor, KVAr, with communication port RJ-45 etc. ii 3 nos. cast resin current transformers of 2000/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch iii 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs iv 1- set Red/Green ON/OFF indicating lamps v 1- set of three phase (red, yellow, blue) indicating lamps vi Amber healthy/ trip indicating lamps vii 3 nos. cast resin current transformers of 2000/5 ratio with 15 VA Burden & Class 5P10 for protection. viii 230 V AC shunt trip coil ix 230 V, AC Motor wound spring closing mechanism x Terminals to receive copper sandwich bus duct xi TNC Switch xii Auto/local/remote selector switch key operated 9.3 1600 Amps, 415 V, 50 kA, 4 Pole, ACB No 1.0 0.0 a) 1600 amps Four pole electrically operated (motorised) fully draw out type air circuit breaker (minimum 50 kA) with built in micro processor based release unit for short circuit, selective short circuit, instantaneous short circuit, Earth fault, Under voltage, over voltage, residual voltage & reverse power protection with adjustable setting. and with the following accessories : i 3 nos. cast resin current transformers of 1600/5 ratio with 15 VA Burden and Class 0.5 with MFM with Voltage, Current, Energy, Power Factor, KVAr, with communication port RJ-45 etc. ii 3 nos. cast resin current transformers of 1600/5 ratio with 15 VA Burden and Class 1.0 with Ammeter and Ammeter selector Switch iii 1 Set of (0-500 volts) digital voltmeter with selector switch with 2 amps MCBs iv 1- set Red/Green ON/OFF indicating lamps v 1- set of three phase (red, yellow, blue) indicating lamps vi Amber healthy/ trip indicating lamps vii 3 nos. cast resin current transformers of 1600/5 ratio with 15 VA Burden & Class 5P10 for protection. viii 230 V AC shunt trip coil ix 230 V, AC Motor wound spring closing mechanism x Terminals to receive copper sandwich bus duct xi TNC Switch xii Auto/local/remote selector switch key operated 9.4 1 no. 1250 A, 415V, 50kA, 4P draw out Electrically operated ACB complete with: No. 1.0 0.0 i 1- set Red/Green ON/OFF indicating lamps ii 1- set of three phase (red, yellow, blue) indicating lamps iii Amber healthy trip indicating lamps iv 3 nos. cast resin current transformers of 1250/5 ratio with 15 VA Burden & Class 5P10 for protection. v 3 nos. cast resin current transformers of 1250/5 ratio with 15VA burden and Class 1.0 for measurement vi Microprocessor based release having variable range of overcurrent, short circuit,UVR and earth fault protection with time log facility for each of the fault for achieving discrimination along with distinct fault indication through LED's. vii 230 V AC shunt trip coil viii 230 V, AC Motor wound spring closing mechanism ix Terminals to receive alum. XLPE armoured cables x RJ-45 port for display of ON/OFF status of ACB on BMS workstation through MODBUS protocol 9.5 1 no. 1000 A, 415V, 50kA, 4P draw out Electrically operated ACB complete with: No. 1.0 0.0 i 1- set Red/Green ON/OFF indicating lamps ii 1- set of three phase (red, yellow, blue) indicating lamps iii Amber healthy trip indicating lamps iv 3 nos. cast resin current transformers of 1000/5 ratio with 15 VA Burden & Class 5P10 for protection v 3 nos. cast resin current transformers of 1000/5 ratio with 15VA burden and Class 1.0 for measurement vi Microprocessor based release having variable range of overcurrent, short circuit,UVR and earth fault protection with time log facility for each of the fault for achieving discrimination along with distinct fault indication through LED's. vii 230 V AC shunt trip coil viii 230 V, AC Motor wound spring closing mechanism ix Terminals to receive alum. XLPE armoured cables x RJ-45 port for display of ON/OFF status of ACB on BMS workstation through MODBUS protocol 9.6 1 no. 800 A, 415V, 50kA, 4P draw out Electrically operated ACB complete with: No. 1.0 0.0 i 1- set Red/Green ON/OFF indicating lamps ii 1- set of three phase (red, yellow, blue) indicating lamps iii Amber healthy trip indicating lamps iv 3 nos. cast resin current transformers of 800/5 ratio with 15 VA Burden & Class 5P10 for protection. v 3 nos. cast resin current transformers of 800/5 ratio with 15VA burden and Class 1.0 for measurement vi Microprocessor based release having variable range of overcurrent, short circuit,UVR and earth fault protection with time log facility for each of the fault for achieving discrimination along with distinct fault indication through LED's. vii 230 V AC shunt trip coil viii 230 V, AC Motor wound spring closing mechanism ix Terminals to receive alum. XLPE armoured cables x RJ-45 port for display of ON/OFF status of ACB on BMS workstation through MODBUS protocol 9.7 630 A, 415V, Ics=50 kA, 4P, MCCB with variable overcurrent and short circuit releases and 1-set of three phase indicating lamps (red, yellow, blue). No 1.0 0.0 9.8 400 Amps, 415V, Ics=50 KA, 4P, MCCB with variable overcurrent and short circuit releases and 1-set of three phase indicating lamps (red, yellow, blue). No 1.0 0.0 9.9 400 Amps, 415V, Ics=35 KA, 4P, MCCB with variable overcurrent and short circuit releases and 1-set of three phase indicating lamps (red, yellow, blue). No 1.0 0.0 9.1 250/200 Amps, 415V, Ics=35 kA, 4P, MCCB with variable overcurrent and short circuit releases and 1-set of three phase indicating lamps (red, yellow, blue). No 1.0 0.0 9.11 250/200 Amps, 415V, Ics=25 kA, 4P, MCCB with variable overcurrent and short circuit releases and 1-set of three phase indicating lamps (red, yellow, blue). No 1.0 0.0 9.12 160/125 Amps, 415V, Ics=35 or 25 kA, TPN, MCCB with variable overcurrent and short circuit releases with heavy duty solid neutral link and 1-set of three phase indicating lamps. No 1.0 0.0 9.13 100 Amps, 415V,Ics=35 kA, FP, MCCB with variable overcurrent and short circuit releases with heavy duty solid neutral link and 1-set of three phase indicating lamps. No 1.0 0.0 9.14 100 Amps, 415V, ,Ics= 25 kA, TP, MCCB with variable overcurrent and short circuit releases with heavy duty solid neutral link and 1-set of three phase indicating lamps. No 1.0 0.0 9.15 Less than 63 Amps to 25 Amps, 415V, Ics=25 kA, TP, MCCB with variable overcurrent and short circuit releases with heavy duty solid neutral link and 1-set of three phase indicating lamps. No 1.0 0.0 9.16 5-32 Amps, 4P, MCB, 9/10 kA No 1.0 0.0 9.17 40-63 Amps, 4P, MCB, 9/10 kA No 1.0 0.0 9.18 5-32 Amps, TP, MCB 9/10 kA No 1.0 0.0 9.19 40-63 Amps, TP, MCB, 9/10 kA No 1.0 0.0 9.2 5-32 Amps, DP, MCB, 9/10 kA No 1.0 0.0 9.21 40-63 Amps, DP, MCB, 9/10 kA No 1.0 0.0 9.22 5-32 Amps, SP, MCB, 9/10 kA No 1.0 0.0 9.23 40-63 Amps, SP, MCB, 9/10 kA No 1.0 0.0 9.24 16-32 Amps, DP, RCCB, 100 mA No 1.0 0.0 9.25 16-32 Amps, DP, RCBO, 100 mA No 1.0 0.0 9.26 16-32 Amps, TP, RCBO, 100 mA No 1.0 0.0 9.27 Multiple LED/neon type indications No 1.0 0.0 9.28 Timer (ASTRO) No 1.0 0.0 9.29 Timer (Manual operated) No 1.0 0.0 9.299999999999999 Ammeter/Voltmeter (3.5 digit display) No 1.0 0.0 9.309999999999999 TP Contractors - 40/32 Amps No 1.0 0.0 9.319999999999999 Aux. Contact 1 NO + 1NC for MCB No 1.0 0.0 9.329999999999998 32-63 Amps, TPN, MCCB (25/35 kA) No 1.0 0.0 a) Supply, installation, testing and commissioning of 32-63 Amps, TPN, MCCB (25/35 kA) in IP 56 rated surface/recessed GI box with the total unit having IP 56 ingress protection with RYB indicating lamps at incoming with trip indications. 9.34 100 Amps, TPN, MCCB (25/35 kA) No 1.0 0.0 a) Supply, installation, testing and commissioning of 100 A, TPN, MCCB (25/35 kA) in IP 56 rated surface/recessed GI box with the total unit having IP 56 ingress protection of suitable size with RYB indicating lamps at incoming with trip indications. 9.35 125/160 Amps, TPN, MCCB (25/35 kA) No 1.0 0.0 a) Supply, installation, testing and commissioning of 125 A, TPN, MCCB (25/35 kA) in IP 56 rated surface/recessed GI box with the total unit having IP 56 ingress protection of suitable size with RYB indicating lamps at incoming with trip indications. 9.36 200 Amps, TPN, MCCB (35/50 KA) No 1.0 0.0 a) Supply, installation, testing and commissioning of 200 A, TPN, MCCB (25/35 KA) in IP 56 rated surface/recessed GI box with the total unit having IP 56 ingress protection of suitable size with RYB indicating lamps at incoming with trip indications. 9.37 250 Amps, TPN, MCCB (35/50 KA) No 1.0 0.0 a) Supply, installation, testing and commissioning of 250 A, TPN, MCCB (25/35 KA) in IP 56 rated surface/recessed GI box with the total unit having IP 56 ingress protection of suitable size with RYB indicating lamps at incoming with trip indications. 9.38 400 Amps, TPN, MCCB (25/35 KA) No 1.0 0.0 a) Supply, installation, testing and commissioning of 400 A, TPN, MCCB (25/35 KA) in IP 56 rated surface/recessed GI box with the total unit having IP 56 ingress protection of suitable size with RYB indicating lamps at incoming with trip indications. 9.39 32 Amps, TPN, MCB (10 KA) No 1.0 0.0 a) Design, supply installation, testing and commissioning of 32 A, TPN, MCB (10 KA) in IP 56 rated surface/recessed GI box with the total unit having IP 56 ingress protection complete as required. 9.4 63 Amps, TPN, MCB (10 KA) No 1.0 0.0 a) Design, supply installation, testing and commissioning of 63 A, TPN, MCB (10 KA) in IP 56 rated surface/recessed GI box with the total unit having IP 56 ingress protection complete as required. TOTAL (PART - J) 0.0 SOLADEVANHALLI DEPOT - SCHEDULE K***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. S.No. Description Unit Qty. Rate (***Refer Note) Total Amount INR K - FIRE DETECTION AND ALARM SYSTEM 1.0 FIRE ALARM SYSTEM- INTELLIGENT ADDRESSABLE SYSTEM The Fire Alarm and Detection System specified herein, must conform to Technical Specifications, in addition to the description given in respective items of BOQ, whether explicitly specified or not. In case of contradiction between Technical specification and description in BOQ, the most stringent of the condition will prevail. All the items / parts mentioned in relevant clauses of the Technical specifications and not specifically mentioned in BOQ shall be deemed to be included in the quoted rates, unless specifically excluded for the complete commissioning of Fire Alarm system Materials and components not specifically stated in the specifications and/or bill of materials or noted on the drawings but which are necessary for satisfactory installation and operation of the system shall be deemed to have been included in the quoted rate and scope of work without any cost implication to Engineer / Employer. All the detectors, modules and other acessories are to be fixed with suitable base plate, 75 mm dia M.S. outlet box or suitable approved M S Box for fixing of the detector base, mounting accessories etc. complete as per specifications and as required. 1.1 Addressable Fire Alarm and Control Panel a) Supply, installation, testing and commissioning of 4 & 2 Loop wall recess mounting microprocessor based networkable Intelligent addressable Fire alarm and Control Panel (FACP) having a Fire Alarm loop Capability to connect required no of Devices & Detectors total per loop as per relevant standard (in Zoned manner) with 20% spare capacity per each loop. 99/125/150 detectors/devices per loop with each loops length being restricted to 65% of manufacturer specified maximum loop length). It shall be expandable by minimum 2 additional loops. The system should be capable of detecting fire within 10sec. as per UL 9th edition. The panel should have front panel keyboard for logic programming and editing capability from the panel and also should have provision for programming from PC/Laptop. b) The operating panel shall have minimum 460 character LED/LCD display, 4 access levels, 1000 events historical logging, flash E-PROM, 240 volts ac power supply, automatic battery charger, 24V sealed lead-acid battery suitable operating the system for 24 hours in emergency condition. The Fire Alarm Panel shall have sufficient numbers of programmable relay controls for monitoring the status of fire hydrant pump. The Panel shall have an automatic battery charger; 24 volts sealed lead acid batteries sufficient for 24 hours normal working and capable of operating the system for 2 hours during emergency conditions as required. The Panel shall have Built-in Ethernet port, Built in Web server and BAC net support and operatable on 240 V AC and shall be complete as per specifications and as required. c) The Panel shall have suitable power amplifiers for hooter/strobes required as per system design with 20% additional wattage for future expansion. (Vendor to submit final amplifier wattage calculations for approval prior to execution stage). The panel shall include the cost of fire workstation PC with requisite software & printer (specification as detailed below). The panel is required to integrate with BMS/SCADA through MODBUS protocol. FACP panel shall be UL/ Vds listed. The price shall include necessary communication card, repeater driver, software with license & graphic cards as required for complete operation. d) Fire Workstation PC & printer specifications e) State of art , Stand alone commercial grade Industrial Desktop, features i7 Processor 16 GB DD SDRAM, 1 TB SATA HDD, 4 GB Graphics card, Integrated Sound & video card with graphics accelerator , optical scroll mouse , multimedia keyboard, 52x CD ROM, Dual LAN card, 2 Serial port, I parallel port, 4 USB Ports, Windows 10 or latest software with latest MS Office package(lifetime) & along with latest antivirus versionMinimum 5 years) suitable for operation on 240 volts, 50 Hz as per specifications as required. f) Colour monitor shall be minimum 19 inch diagonal nonglare graphic flat TFT/LCD screen high resolution with minimum VGA resolution of 1280X1024 pixels and contrast ratio 700:1. as per specifications etc. as required. g) Laser Printer- A hard-copy multi-color graphics Laser Printer shall be provided for recording graphic displays and associated dynamic data.Print speed – Black: up to 22 ppm; color: up to 4 ppm.First page out – 18 seconds black, 29 seconds color.Resolution- 600 by 600 dpi.Hi-Speed USB 2.0, IEEE 1284-B compliant parallel port.Languages – PCL 6 and Postscript level 3 emulation with automatic language switching.Font capabilities – 80 TrueType TM internal scalable PCL 6 fonts; 1.2 4 Loop FACP Panel as per above specification Set 1.0 0.0 1.3 Repeater panel Supply, Installation, Testing and Commissioning of 80 character LCD display Repeater Panel which mimics all display information from the host panel and control switch for system acknowledge, signal silence, drill and reset with enable key. The repeater panel shall have system LEDs for Power, Alarm, Trouble, Supervisory and Alarm silenced. It should display device type identifiers, individual point alarm, Trouble or Supervisory, Zone, Custom alpha labels. It should have time and date display field. The panel shall have provision to be powered by 24Vdc from host FACP or from remote 24Vdc power source. It should be capable of being remotely located up to 300 meters from host control panel as per Specifications and Drawings. Set 1.0 0.0 1.4 Intelligent addressable Multi-Criterion Detectors Nos 272.0 0.0 Supply, installation, Testing & commissioning of Automatic floating sensitivity type Intelligent Addressable microprocessor based photo thermal Multi sensing smoke detector with suitable approved metal box & mounting based LED providing 360 degree viewing angle, address switch to program the detectors, complete as required. sensitivity level shall be adjusted automatically without the need for operator intervention or programming. The address need to be viewed and changed without the need for electronic programmer. 1.5 Intelligent addressable Heat Detectors 1.6 Supply, installation, testing and commissioning of plug-in type Multi Co-operative Sensing Analog Addressable Rate of Rise Cum Fixed temperature detector with suitable approved metal box & mounting based LED providing address switch to program the detectors complete as required. The address need to be viewed and changed without the need for electronic programmers. Nos. 12.0 0.0 1.7 Fault Isolator Modules Nos. 44.0 0.0 Supply, installation, Testing & commissioning of Intelligent addressable fault isolator module with suitable approved metal box & base and capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected. The address need to be viewed and changed without the need for electronic programmer. 1.8 Manual Call Point Nos. 62.0 0.0 Supply, installation, Testing & commissioning of Intelligent addressable single action resettable manual pull station to initiate audio visual alarm having an integrally mounted addressable module that monitors and reports contact status. The address need to be viewed and changed without the need for electronic programmer. 1.9' Wall/ Ceiling mounting strobes Nos. 62.0 0.0 Supply, installation, Testing & commissioning of Wall mounted Intelligent addressable Hooter with strobe having an integrally mounted addressable module that monitors and reports contact status. The address need to be viewed and changed without the need for electronic programmer. Including additional power supply arrangement as required. 1.10' Control Modules Nos. 64.0 0.0 Supply, installation, testing and commissioning of Control Modules that monitors and reports contact status,including mounting accessories complete as per specifications and as required. 1.11 Monitor Modules Nos. 21.0 0.0 Supply, installation, testing and commissioning of Monitor Modules that monitors and reports contact statusincluding mounting accessories complete as per specifications and as required. 1.12 Response Indicator Nos. 78.0 0.0 Supply, installation, testing and commissioning of Response Indicator Lamp assembly in a dust tight sheet steel enclosure as per detailed specifications including accessories for recess mounting as per approved sample as required. 1.13 Cabling For Fire Detection And Alarm System 1.14 Supply, installation, testing and commissioning of size 2C x 1.5 sqmm twisted pair ,screened, Armoured Fire survival cables complying with BS 7629 category CWZ as per BS 6387 including termination with suitable glands, earth tag & lugs. Mtr 11000.0 0.0 1.15 Supply, installation, testing and commissioning of size 2C x 2.5 sqmm twisted pair ,screened, Armoured Fire survival cables complying with BS 7629 category CWZ as per BS 6387 including termination with suitable glands, earth tag & lugs. Mtr 100.0 0.0 1.16 Power supply unit with enclosure for hooter with 230 V AC as input and 24V DC as output. Nos. 40.0 0.0 1.17 Beam detector Supply, installation, testing and commissioning of Beam detector including mounting accessories complete as per specifications and complete as required. Nos. 10.0 0.0 1.18 GI conduits a) Supply, installation, testing and commissioning of following sizes GI conduits recessed/surface as required including clamps, hardware etc required for surface conduiting and cutting and filling chases for recessed conduiting complete as per specifications. b) Wherever required flexible conduits shall also be provided at locations like bends etc and its cost shall be built in the GI conduit only. c) After making the recessed the wall etc shall be repaired and brought to its original finish. No extra payment shall be made for this finishing work. i) 20 mm dia GI Conduit Mtr 130.0 0.0 ii) 25 mm dia GI Conduit Mtr 130.0 0.0 1.19 Supply, installation, Termination, Testing & commissioning of Fire Survival, CWZ category Cables (confirming to BS: 7629 and specifications for performance requirements of Fire Survival Cables, CWZ category) un-armoured, 2 core x 2.5 sq.mm, screened / shielded, Copper conductor (one pair shielded ) cable including all required accessories like gland, clip clamp, shrouds, etc. Mtr 2550.0 0.0 1.2 Supply, installation, Termination, Testing & commissioning of Fire Survival Cables, , CWZ category (confirming to BS: 7629 and specifications for performance requirements of Fire Survival Cables, CWZ category) un-armoured, 1 twisted pair, 2 core x 1.5 sq.mm, screened / shielded copper conductor cable including all required accessories like gland, clip clamp, shrouds, etc. Mtr 7500.0 0.0 1.21 System commissioning including programming of FACP, repeater panel and integration of BMS/SCADA etc. and performing required drills during various stages of inspections by employer, local fire authorities and CMRS. L.S. 1.0 0.0 TOTAL FOR K (FIRE ALARM SYSTEM) 0.0 SOLADEVANHALLI DEPOT - SCHEDULE L***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. S.No. Description Unit Qty. Rate (***Refer Note) Total Amount INR L-HVAC WORKS IMPORTANT NOTE: a) The rates will include foundations of equipments and painting of all metal parts , pipes, fittings, vessels, etc. with two coats of anticorrosive paint and two coats of enamel of approved shade and brand irrespective of whether mentioned or not. b) The Equipment's shall be on M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation in cement concrete 1:2:4 - 300mm high and 150mm projection on all side of base plate, 12mm thick cement plaster in cement mortar 1:4 finished with a floating coat of neat cement duly plastered with anti vibration pads. c) For all pressure gauges's & switches connectioned to be made with suitable Gun Metal Shut Off Cock & Syphon. d) Materials and components not specifically stated in the specifications and/or bill of materials or noted on the drawings but which are necessary for satisfactory installation and operation of the system shall be deemed to have been included in the quoted rate and scope of work without any cost implication to Engineer / Employer 1.0 VRF/VRV and Split Type Air Conditioners Supply, Installation, testing and commissioning of Air Cooled Variable Refrigerant Volume / Variable Refrigerant Flow System suitable for R410A / R32 and 415 ± 10% , 50 Hz, AC supply. The unit shall consist of indoor units and external condensing units and other accessaries as listed below complete in all respects. The unit shall be fully charged with gas and oil. 1.1 Outdoor Unit Supply, installation, testing and commissioning of Modular type outdoor condensing units equipped with highly efficient scroll / Rotary compressors with digital invertor technology, special acryl precoated heat exchanger,low noise condenser fan with motor, auto check function for errors in display panel, auto address setting, as per specifications and capacities as mentioned below. The units shall be complete with necessary mounting frames and required acessories 1.1.1 52 HP Nos. 4.0 0.0 1.1.2 46 HP Nos. 1.0 0.0 1.1.3 30 HP Nos 1.0 0.0 1.2 DUCTABLE/ CONCEALED INDOOR UNITS Supply, Installation, Testing & Commissioning of ductable (High Static) indoor units with evaporator coil, filter, fan and fan motor drain pan. The units shall be of following capacities with all other acessories required for full fledged opearation of system. Nothing extra will be paid in this account. 1.2.1 1.0 TR Nos. 1.0 0.0 1.2.2 2.5 TR Nos 1.0 0.0 1.2.3 3.18 TR Nos. 1.0 0.0 1.2.4 4.55 TR Nos. 10.0 0.0 1.2.5 6.36 TR Nos. 4.0 0.0 1.26 7.95 TR Nos. 12.0 0.0 1.3 Supply, installation, tesing and commissioning of Corded Remote controllers for operation of indoor units Nos. 26.0 0.0 1.4 Supply, installation, testing and commissioning of Central Remote Controller for complete system including all VRV/VRF indoor and outdoor units. Nos. 1.0 0.0 1.5 Supply, installation, testing and commissioning of Scheduled Timer. Nos. 1.0 0.0 1.6 REFRIGERANT PIPING Supplying, installing, testing and commissioning of interconnecting refrigerant pipe work with elastomeric nitrile rubber/closed cell expanded polythene tubular insulation between each set of indoor & outdoor units as per specifications, all piping should be laid on Galvanised/Powder Coated tray supported by Galvanised M S Hangers & Clamps. The rate also includes cost of Y-joints, distributer and headers in the refrigeration piping system wherever required. The rate also includes items required to complete the work with all other acessories required for full fledged operation of system and nothing extra should be payable. 1.6.1 41.3 mm O.D.(insulation - 19 mm thick) RMT 65.0 0.0 1.6.2 34.9 mm O.D.(insulation - 19 mm thick) RMT 29.0 0.0 1.6.3 28.6 mm O.D.(insulation – 19 mm thick) RMT 50.0 0.0 1.6.4 22.2 mm O.D.(insulation – 19 mm thick) RMT 9.0 0.0 1.6.5 19.1 mm O.D.(insulation – 13 mm thick) RMT 115.0 0.0 1.6.6 15.9 mm O.D.(insulation – 13 mm thick) RMT 36.0 0.0 1.6.7 12.7 mm O.D.(insulation – 13 mm thick) RMT 43.0 0.0 1.6.8 9.5 mm O.D.(insulation – 13 mm thick) RMT 50.0 0.0 1.6.9 6.4 mm O.D.(insulation – 13 mm thick) RMT 1.0 0.0 1.7 CONTROL CABLING 1.7.1 Supply, installation, testing and commissioning of control cum transmission wiring of 3 core x 1.5 Sq.mm copper FRLSZH, PVC insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work, wall and floor shall be repaired and brought to its original finish. The rate shall include cost of laying of GI conduit between indoor and outdoor units. RMT 1290.0 0.0 1.8 Air Cooled Split type wall mounted Air conditioners Supplying, installing, testing and commissioning of Inverter Based Energy Efficient Air Cooled Split type wall mounted Air conditioners with evaporating unit comprising of cooling coil, blower with motor and condensing unit comprising hermetically sealed rotary compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, drain pipes and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. Nothing extra shall be paid on any account i.e. refrigerant pipes, drain pipes etc. 1.8.1 1.5 TR Nos. 1.0 0.0 1.8.2 2.0 TR Nos. 7.0 0.0 1.9 Condensate Drain Piping: Providing, fixing and testing GI Class B drain piping for condensate from unit to nearest suitable drain system as per site conditions as per instruction of site engineer complete with all required fittings and providing clean out plug at suitable location for the pipe when required complete with 6mm thick elastomeric nitrile rubber insulation over GI pipe: 1.9.1 32mm Dia. RM 196.0 0.0 1.9.2 25mm Dia. RM 260.0 0.0 L.02 VENTILATION SYSTEM 2.1 Tube Axial Type Fans for Staircase & Lift pressurization Design, Supply. Installation, testing and commissioning of Vane/Tube Axial flow fans including motors, anti vibration mounts, flexible sleeves. Fan motors and all accessories shall be complete as per Specifications.(Bidders are required to optimize the total pressure as per final detailed design to achieve the performance without any additional cost to Engineer / Employer) 2.1.1 Capacity 8500 CFM at 300 Pa static pressure (Staircase) Nos. 2.0 0.0 2.1.2 Capacity 10800 CFM at 300 Pa static Lift pressurization Fan Nos. 2.0 0.0 2.2 Inline Fan 2.2.1 Design, Supply. Installation, testing and commissioning of Inline fan with cetnrfugal blower and motor encased in sheet metal casing, as per specification the motor shall be suitable for 220V+- 6% 50Hz Ac supply capacity 1150CFM static pressure 150pa. Nos 3.0 0.0 2.3 Propeller Type Fans Design, Supply. Installation, testing and commissioning of Propeller type fan wall or panel mounting to convey air directly to out side complete with motor suitable for 240/440 volts, 1/3 phase, 50 Hz AC supply, mounting frames and louvers and complete as per specifications. 2.3.1 300 Dia. Nos. 15.0 0.0 2.3.2 380 Dia. Nos. 1.0 0.0 2.3.3 450 Dia. Nos. 1.0 0.0 2.4 Axial Flow Fans & Attenuators Axial flow fans including motors, anti vibration mounts, up and downstream metallic diffusers with their supports and flexible sleeves. Fans, motors, sound attenuators, and all accessories shall be complete as per Specifications.VEF 3.0 cms, 300 Pa Nos. 1.0 0.0 2.5 Air Circulater Fan Supply. Installation, testing and commissioning of 230V 1Phase 1400rpm sweep of approx750mm bracket fan including mounting bracket blade, starters and other standard accessories complete as required confirming to IS 2997-1964. Nos. 160.0 0.0 2.6 Kitchen Scrubber Supply. Installation, testing and commissioning of Scrubber (nozle type double skin air washer)Scrubber shall be factory fabricated and complete with fan casing,humidifier section, SS tank,DIDW(double inlet double width) centrifugal backward curved fan with motor monobloc pumps,brass spray nozzles and water distribution header,piping with valves and fittings between pumps and scrubber,4 bend PVC/GI eliminator along with electrical panel and starter etc complete as per specification.Capacity 4500 cfm static pressure 50mmwg. Nos. 1.0 0.0 L.03 AIR DISTRIBUTION SYSTEM 3.1 Supply. Installation, testing and commissioning of factory fabricated G.I. Sheet metal ducts (275 GSM) with flanges complete with supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications. 3.1.3 1.00 MM (20 Gauge ) sqm 25.0 0.0 3.1.2 0.80 MM (22 Guage) sqm 1.0 0.0 3.1.3 0.63 MM (24 Guage) sqm 1.0 0.0 3.2 Grills and Dampers 3.2.1 G.I construction Duct Dampers Design, Supply. Installation, testing and commissioning of G.I construction Duct Dampers for Controlling the Airflow in Ducts as per specification. Sqm 3.0 0.0 3.2.2 Grills without Dampers Design, Supply. Installation, testing and commissioning of powder coated extruded aluminum sections grills as per specification. Sqm 3.0 0.0 3.2.3 Grills with Dampers Design, Supply. Installation, testing and commissioning of powder coated extruded aluminium section grills with dampers for supply air terminal for air-conditioning as per specification. Sqm 3.0 0.0 3.2.4 Diffusers Design, Supply. Installation, testing and commissioning of powder coated extruded aluminium square diffusers with antismudge ring and removable core. 3.2.4.1 Supply air with dampers Sqm 13.0 0.0 3.2.4.2 Return air without damper Sqm 13.0 0.0 3.2.5 Linear Grills Design, Supplying, installing, testing and commissioning of powder coated extruded aluminium section Linear grills supply / Return air as per specification.. Sqm 1.0 0.0 3.2.6 Exhaust/Fresh Air Louvers Design, Supply. Installation, testing and commissioning of exhaust air/fresh air louvers of powder coated extruded aluminium construction with bird screen, minimum 80 mm deep. Sqm 3.0 0.0 3.3 Duct Insulation Design, Supply. Installation, testing and commissioning of Nitrile rubber insulation on the surface of the duct per specifications . The rates shall include all materials of the insulation and labour works with adhesive, complete as required and specifications. 3.3.1 25 mm Sqm 15.0 0.0 TOTAL OF VAC SYSTEM 0.0 SOLADEVANHALLI DEPOT - SCHEDULE M***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. S.No. Description Unit Qty. Rate (***Refer Note) Total Amount INR M- FIRE FIGHTING SYSTEM M.0 FIRE FIGHTING WORKS IMPORTANT NOTE: a) The rates will include foundations of equipments and painting of all metal parts , pipes, fittings, vessels, etc. with two coats of anticorrosive paint and two coats of enamel of approved shade and brand irrespective of whether mentioned or not. b) The Equipment's shall be on M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation in cement concrete 1:2:4 - 300mm high and 150mm projection on all side of base plate, 12mm thick cement plaster in cement mortar 1:4 finished with a floating coat of neat cement duly plastered with anti vibration pads. c) For all pressure gauges's & switches connectioned to be made with suitable Gun Metal Shut Off Cock & Syphon. d) Materials and components not specifically stated in the specifications and/or bill of materials or noted on the drawings but which are necessary for satisfactory installation and operation of the system shall be deemed to have been included in the quoted rate and scope of work without any cost implication to Engineer / Employer. e) The pump heads specified on the Drawings and / or Equipment Schedules are for guidance and information only and are calculated based on assumed equipment pressure drops. The exact pump head based on the pipe run and the offered equipment shall be carefully checked and re-calculated for each pump before ordering the equipment. Calculation shall be submitted for approval. No modification to the piping system shall be allowed without prior approval. Any additional cost for the modification of the system (pumps, motors, switchgears, cables, panel boards, switchboards, etc.) necessary to meet the specified duties, special conditions and the offered equipment shall be provided at no extra cost to the Employer. All Main Fire Pumps shall be capable of delivering 150% of the rated flow at a head not less than 65% of the rated head. Also the shut-off head shall not exceed 140 % of the rated head. 1.0 HYDRANT FIRE PUMP-Elctric Driven The rate shall include Supply, Installation, Testing and Commissioning of electric driven main fire pump suitable for automatic operation and complete in all respect as required. Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sqcm at highest and farthest outlet at specified flow , head conforming to IS 1520. The pump shall have suitable HP SQ cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. The pump and motor shall be on M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts, cable termination adaptor box, etc. as required. (design and drawing to be provided by the Contractor while the foundation will be done by others) with anti vibration pads.Pump Shall Include necessary Pressure Gauge & Pressure Switch with necessary Gun Metal Shut Off Cock and syphon on delivery side including all aspects. The pump shell be complete in all respects and as per specification. i) 2850 LPM @ 90 m Head Nos 2.0 0.0 2.0 Jocky Pumps The rate shall include Supply, Installation, Testing and Commissioning of electric driven pressurization Jockey pump suitable for automatic operation and complete in all respect as required. Vertical type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and specified flow, head conforming to IS: 1520. The pump shall have suitable HP SQ cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class 'F' insulation, conforming to IS: 325. The pump and motor shell be on M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (design and drawing to be provided by the Contractor while the foundation will be done by others) with anti vibration pads. The pump shall be complete in all respects and as per specification. i) 180LPM @ 90M Head Nos 2.0 0.0 3.0 G.I Pipes a) Above Ground : Providing, laying, jointing, painting, testing and commissioning of following sizes of G.I. class `C' (heavy class) pipes conforming to IS:3589 & IS-1239 with all accessories like all fittings (standard G.I. fitting with welded joint shall be used on the pipes) including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts, washer including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fastners) or angle iron support work in trenches as per specification. G.I. pipe sleeve of suitable higher size shall be provided wherever the pipes are crossing the walls/floors and sealing the sleeves with glass wool in between & fire sealent compound at either end all as per Engineer / Employer requirements including cutting holes and chases in brick and making good the same to original conditions complete in all respects. (For above ground works) b) All hangers, civil support for external pipes, clamps, brackets etc. shall be of galvanized iron unless specified otherwire and then supply of the same shall also be included for rates under this head. Including two coats of synthetic enamel paint of approved shade over a coat of primer. Prior to application of primer the surface should be cleaned for any dirt, rusts, rough substance etc. Including painting of legends by arrow in both directions as per the approval of the Engineer / Employer. c) Welding of any kind on galvanized support / hanger shall not be permitted 3.1 200 mm dia (wall thickness 6 mm.) Mtr 28.0 0.0 3.2 150 mm dia Mtr 4550.0 0.0 3.3 100 mm dia Mtr 60.0 0.0 3.4 80 mm dia Mtr 2100.0 0.0 3.5 65 mm dia Mtr 36.0 0.0 3.6 50 mm dia Mtr 48.0 0.0 3.7 40 mm dia Mtr 24.0 0.0 3.8 32 mm dia Mtr 30.0 0.0 3.9 25 mm dia Mtr 150.0 0.0 4.0 GI Piping (Below Ground) Providing, laying, jointing, painting and testing in trenches the following sizes of G.I. class `C' (heavy class) pipes conforming to IS:3589 & IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, GI nuts, bolts and washers and providing protection to embedded G.I. pipes and fittings by applying pypkote primer (@ 100 gm/sqm) thereafter wrapping 4 mm thick pypkote (AW 4 mm) protection coating by thermo fusion process. Overlap shall be maintained at 15 mm. The application process shall be strictly in accordance to manufacturer’s specification, including necessary excavation trenches and refilling as required. (For under ground works) 4.1 80 mm dia Mtrs. 76.0 0.0 4.2 150 mm dia Mtrs. 280.0 0.0 5.0 SINGLE HEADED HYDRANT VALVE Nos 108.0 0.0 The rate shall include supply and fixing stainless steel single headed hydrant valve with instantaneous Stainless steel couplings of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Stainless steel cap and chain, nuts, bolts, rubber gaskets etc. as required. 6.0 BUTTERFLY VALVE The rate shall include supply, fixing, testing and commissioning of butterfly valve PN 16, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS 13095, of following sizes as required. 6.1 200 mm dia Nos 7.0 0.0 6.199999999999999 150 mm dia Nos 35.0 0.0 6.299999999999999 100 mm dia Nos 7.0 0.0 6.399999999999999 80 mm dia Nos 114.0 0.0 6.499999999999998 65 mm dia Nos 4.0 0.0 7.0 ORIFICE PLATE The rate shall include supply and fixing stainless steel orifice plate made out of 8 mm. thick stainless steel plate for pipe to reduce pressure upto 3.5 kg/sqcm. complete in all respects. 7.1 80 mm dia Nos 116.0 0.0 8.0 NON-RETURN VALVE The rate shall include supply, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to API 594 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 8.1 150 mm dia Nos 9.0 0.0 8.2 65 mm dia Nos 4.0 0.0 8.3 100 mm dia Nos 4.0 0.0 9.0 POT STRAINER The rate shall include supply and fixing MS Body Pot strainer with stainless steel perforated sheet basket tested to a pressure of 15 Kg/sqcm. Including rubber gasket, flanges, nuts, bolts and washers complete as required. 9.1 200 mm dia Nos 2.0 0.0 9.2 80 mm dia Nos 1.0 0.0 10.0 GUN METAL BALL VALVE The rate shall include supply and fixing Gun metal ball valve CI hand wheel suitable for pressure 15 Kg/sqcm. and confirming to relevant IS of the following size including providing necessary union/flange and making proper connection for air testing and drainage system. 10.1 50 mm dia Nos 2.0 0.0 11.0 SYNTHETIC FIRE HOSE PIPE(RRL) Nos 228.0 0.0 The rate shall include supply and fixing synthetic fire hose pipe (as per IS 636 Type II ) of 63 mm dia and 15 m length. The hose shall be rated for burst pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked stainless steel male & female coupling (IS: 903) bound & riveted to hose pipe with copper wire and as per specifications. 12.0 SHORT BRANCH PIPE Nos 115.0 0.0 The rate shall include supply and fixing 63 mm dia standard stainless steel short Branch Pipe as per IS 903 with 20 mm nozzle complete with fixing clamps. 13.0 FIRST AID HOSE REEL Nos 29.0 0.0 The rate shall include supply and fixing First-Aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with upto date amendments, complete with the following as required. 36 meter, 25 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced) Type- 2 as per IS: 12585. 25 mm (nominal internal) dia stainless steel globe valve & 7 mm shut off nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 40 mm dia stop valve (stainless steel) & G.I Pipe.With Valve & NRV as required 14.0 DOUBLE FLANGED EXPANSION JOINT The rate shall include supply and fixing double flanged flexicon rubber expansion joint with unit control of standard length. Tested to a pressure of 15 Kg/sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required and as per specifications. 14.1 65mm dia Nos 1.0 0.0 14.2 80 mm dia Nos 1.0 0.0 14.3 150 mm dia Nos 2.0 0.0 14.4 200 mm dia Nos 2.0 0.0 15.0 HOSE CABINET (External) Nos 88.0 0.0 The rate shall include supply and fixing of hose cabinet of size 750 mm x 600 mm x 450 mm made of 2 mm thick M.S with 6 mm thick glazed glass doors including necessary locking arrangement suitable to accommodate external hydrant with butter fly valve, 2 Nos.15 mtr. Long Hose pipe, 1 No. branch pipe, mounted on wall OR raised brick platform 600 mm in height built in brick masonry in cement mortar 1:5, 12mm thick plaster on all sides and finished with existing/ proposed external finish & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect, for external hydrants, as required and as per specifications. 16.0 FIRE HOSE DOOR CABINATE (Internal) Nos 29.0 0.0 The rate shall include supply and fixing angle iron (40mm x 40mm x 5mm) door frame and M.S. sheet (2mm thick) cum glass shutter of size 2.1 mtr x 1.2 mtr with 25 mm x 25 mm x 3 mm angle frame all around & stiffened in between including hinges, handle, locking arrangement, painting with two coats of anticorrosive primer and two coats of synthetic enamel paint of approved make including sign writing on glass at internal hydrant including providing & fixing M.S. sheet 2 mm thick on remaining portion above door to close opening including painting etc. as required. 17.0 BREECHING HEAD Nos 2.0 0.0 The rate shall include supply and fixing inlet breeching having C.I. body 4 way gun metal 63 mm dia instantaneous inlets conforming to IS 905 fitted with non return valves 25 mm dia gun metal drain cock, blank cap, brass chains and 150 mm dia flanges with all accessories suitable for local fire tender complete as required. 18.0 FIRE BRIGADE CONNECTION Nos 1.0 0.0 The rate shall include supply and fixing 2 way fire brigade connection of cast iron body with 4 Nos. gun metal male instantaneous inlet couplings complete with cap and chain as required for 100 mm dia GI pipe connection, conforming to IS 904 as required. 19.0 GUN METAL COLLECTING HEAD Nos 1.0 0.0 The rate shall include supply and fixing gun metal IS: 778 collecting head (draw off connection) with 150 mm dia outlet, suitable for local fire tender complete in all respects. 20.0 PRESSURE VESSEL / AIR VESSEL Nos 1.0 0.0 The rate shall include supply, fixing, testing and commissioning of air vessel tank made from 6 mm thick M.S. plate of 450 mm dia & 2m height with dished ends of 8 mm thick, supporting legs, inlet & outlet flanged connections pressure switches with valve to operate as per operating sequences including 80 mm dia drain valve, air release valve with stop cock on the top Duly painted with two coats of anticorrosive primer inside and outside , epoxy paint inside, two coats of postal red enamel outside of approved make and outside complete as required and as per specifications. 21.0 Forged Brass Automatic Air Release Valve Nos 19.0 0.0 Air release valves with ball valve shall be provided in the piping system for venting trapped air with a size of 25mm for pipes upto 100mm and 40 mm for larger pipes and number of cycle minimum more than 3000. 22.0 INSPECTORS TEST ASSEMBLY Nos 1.0 0.0 The rate shall include supply and fixing inspectors test assembly complete with 50 mm test valve. 23.0 QUARTZOID BULB TYPE SPRINKLERS Nos 85.0 0.0 The rate shall include supply of 15 mm size quartzoid bulb type sprinklers of rating 68 degree C. pendent / upright with required accessories. 24.0 PRESSURE SWITCH Nos 5.0 0.0 The rate shall include supply and fixing PN 16 Differential Pressure Switch in the GI. Pipe Line including connection etc. as required. 25.0 CONTROL VALVE Nos 1.0 0.0 The rate shall include supply, fixing, testing & commissioning of 150mm dia installation control valve of Cast iron body and brass / bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/ Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, g.i pipe of required size, flanges, orifice plate, gasket etc. of size150 mm dia as required. All exposed M.S. pipe fitting and other parts will be painted with two coats of anticorrosive primer and two coats of postal enamel of approved make.as per Direction of Engineer in Charge. 26.0 PRESSURE GAUGE Nos 40.0 0.0 The rate shall include supply and fixing pressure gauges of not less than 100 mm dia dial of pressure range 0- 15 kg/sqcm complete with shut off valve duly calibrated before installation. 27.0 FLOW SWITCH Nos 1.0 0.0 The rate shall include supply and fixing flow switches in 65/80/100 / 150 mm. dia GI Pipe complete in all respects. 28.0 FIRE EXTINGUISHER CO2 GAS 4.5 KG Nos 49.0 0.0 The rate shall include supply and fixing fire extinguisher of 4.5 kg CO2 gas type conforming to IS: 15683 with insulated discharge horn, mounting bracket ISI marked extinguisher and valve with initial refill. 29.0 FIRE EXTINGUISHER ABC DRY POWDER Nos 56.0 0.0 The rate shall include supply and fixing 4 Kg Fire Extinguishers (A, B, C type powder) complete with all accessories as per IS: 15683 30.0 Providing and fixing fire extinguisher water type of capacity 9 litre with internal plastic lining and IS marked as per IS 940 with gun metal cap, CO2 cartridge and initial refill. Nos 1.0 0.0 31.0 MASONARY CHAMBER Nos 12.0 0.0 The rate shall include Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for butterfly valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. 32.0 CLEAN AGENT PANEL FLOODING SYSTEM- FIRE TRACE TUBE SYSTEM OR EQUIVALENT WITH UL LISTED SYSTEM 32.1 Supply, fixing, testing and commissioning of UL 521, UL listed Polymer Tube Detection based Clean Agent Fire Suppression System for Electrical Panels, consisting of the following components: Main LT Panel, Emergency Panel 32.1.1 Direct Low Pressure Clean Agent system 10 lbs capacity, complete with Clean agent) (NOVEC 1230 or equivalent), D.O.T/TC approved Cylinder, nickel plated brass valve with slip on union connector, isolation valve, plug pressure switch port and 195 psi Pressure gauge fittings, operating pressure 195 psi (13.45 Bar) at 70 Deg F, supplied complete with Bolt Pattern Bracket and:INCLUDING Nos 2.0 0.0 i Fill Port ii Outlet Port iii End of Line adaptor, iv End of line Adopter - 2 nos. v Pressure switch 32.1.2 Flexible 4/6mm UL 521, UL listed Polymer Detection Tube 195 Deg C rated complete with all necessary fittings & supports to make each entire system functional - 2 nos. Mtr 400.0 0.0 32.1.3 System Indication & Control Unit (SICU) integrated panel for indicating the Health and operational status of the system, complete with ports to interface pressure switch, Audio visual Alarm unit, and output to FACP and BMS/ SCADA System including all necessary accessories. Nos 2.0 0.0 32.2 Supply, fixing, testing and commissioning of UL 521, UL listed Polymer Tube Detection based Clean Agent Fire Suppression System for Electrical Panels, consisting of the following components:(ADMIN Building, RBL, DCO, Pump Room, AMF Panel) 32.2.1 Direct Low Pressure Clean Agent system 5 lbs capacity, complete with Clean agent) (NOVEC 1230 or equivalent), D.O.T/TC approved Cylinder, nickel plated brass valve with slip on union connector, isolation valve, plug pressure switch port and 195 psi Pressure gauge fittings, operating pressure 195 psi (13.45 Bar) at 70 Deg F, supplied complete with Bolt Pattern Bracket and:INCLUDING Nos 10.0 0.0 i Fill Port ii Outlet Port iii End of Line adaptor, iv End of line Adopter - 2 nos. v Pressure switch 32.2.2 Flexible 4/6mm UL 521, UL listed Polymer Detection Tube 195 Deg C rated complete with all necessary fittings & supports.o make each entire system functional - 2 nos. Mtr 740.0 0.0 32.2.3 System Indication & Control Unit (SICU) integrated panel for indicating the Health and operational status of the system, complete with ports to interface pressure switch, Audio visual Alarm unit, and output to FACP and BMS/ SCADA System including all necessary accessories. Nos 10.0 0.0 33.0 LEVEL CONTROLLERS / LEVEL INDICATORS Supply, Installation, Testing and Commissioning of Magnetic Float type Level Controllers / Indicators having adequate number of switches (Minimum 5 Nos.) for the services mentioned below. Controller Equipment shall be mounted inside the electrical panels 33.1 For Raw Water tanks for the following levels. Set 1.0 0.0 i) High High level to trigger alarm. ii) High Level to switch OFF the Tube well. iii) Raw Water Tank 1/2 full iv) Low Low level to trigger alarm 33.2 For Fire Water Tanks, one set for each of the tanks for the following levels. Set 1.0 0.0 i) High Level to trigger alarm ii) Full Fire Water Tank indication iii) Low low level in fire water tank to trigger alarm 33.3 For Treated Water Tank for the following levels Set 1.0 0.0 i) High High level to trigger alarm ii) High Level to switch OFF the Filter feed / Softener Plant Pumps. iii) Treated Water Tank 1/2 full iv) Low Level to switch ON the Filter Feed / Softener Plant Pumps v) Low Low level to trigger alarm Note: All above level Controllers / Indicators to be complete with sensors, switches, relays, all wiring from the sensors to the Control Unit, Control Units to Motor Control Centres of the various Pumps/ Valve and to the various alarm and indicating devices. Sensors Terminal Units would be in weather proof enclosures (IP-56). 34.0 Fire protective clothing & breathing apparatus Nos 1.0 0.0 34.1 Set of protective clothing containing 2 nos of each following items: a) Coat b) Trouser c) Gloves d) Anti-Flash Hood e) Helmets f) Boots g) Cabinet 34.2 Self- contained open circuit type compressed air Breathing apparatus set confirming to EN-137:1993 , standard complete with one spare cylinder, Nos 1.0 0.0 a) Air cylinder with valve b) Back plate with body harness c) Face mask d) Pressure reducer e) Lung demand valve f) Pressure gauge & warning whistle g) Hoses h) Carrying case i) Spare air cylinder j) Cabinet 35.0 Pedestal Support AAC Block for Pipe Support on Above Ground Piping (Pedestal) cum 18.0 0.0 36.0 R.C.C Hume Pipe Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round R.C.C pipes including bed concrete as per standard design. 250 mm dia. R.C.C pipe Mtr. 92.0 0.0 37.0 INERGEN GAS FLOODING SYSTEM i) The 300 bar Gas flooding system specified herein must confirm to Technical Specifications, in addition to the description given in respective items of BOQ, whether explicity specified or not. In case of contradiction between specifications and description in BOQ, the most stringent of the condition will prevail. ii) The description as mentioned in this BOQ including details as mentioned in GCC, SCC, Employers Requirement General specifications & Technical specifications, Drawing and the conditions mentioned therein whichever is stringent shall be applicable, acceptable and complied with. iii) The quantity estimated here in BOQ are tentative. The items indicating zero quantity can also be operated and variation clause shall be applicable as stipulated in GCC / SCC. iv) Calculation details for selection of equipments / materials shall be submitted for approval of Employer or his representative. v) Materials and components not specifically stated in the specifications and/or Bill of materials or noted on the drawings but which are necessary for satisfactory installation and operation of the system shall be deemed to have been included in the quoted rate and scope of work without any cost implication to Engineer / Employer vi) All equipments, instruments, Gas cylinders, Inert gas agent etc, must comply with the requirement of NFPA-2001 vii) In case of any modification to the item discription, then the rates shall be derived from the similar BOQ items if available. viii) Installation of Inert gas system (IG-541) shall be done by certified system integrator of the vendor manufacturer. ix) Fire Fighting system (Actuation hose, actuation adapter, Booster actuator, Lever actuator, Reset tool booster actuator, pressure reducer, Gas dischrge pressure switch, warning plate, nozzle, safety releif plug..)system to be integrated with fire detection system for system actuation. x) Fire alarm system (Gas release module, control module, Monitor Module, Abort switch, coil supervisory switch, Manual release button, Hooter cum strobe, fire survival cables..) xi) All piping for Inert gas shall be carbon steel and should withstand 1.5 times pressure of the system working pressure 37.1 Supply, installtion, testing and commissioning of inert gas flooding system containing following components, acessories complete as per specifications. 37.1.1 80L Container Assembly, contacted pressure gauge, Nos. 1.0 0.0 37.1.2 140L Container Assembly, contacted pressure gauge, Nos. 1.0 0.0 37.1.3 Pilot Cylinder Assembly, solenoid, and manual release, Nos. 1.0 0.0 37.1.4 Placement Indicator - Pilot Container Nos. 1.0 0.0 37.1.5 Pilot Valve Adaptor Nos. 1.0 0.0 37.1.6 Bleed Valve Nos. 1.0 0.0 37.1.7 Discharge Hose Nos. 1.0 0.0 37.1.8 Actuation Hose Nos. 1.0 0.0 37.1.9 Pneumatic Actuator Nos. 1.0 0.0 37.1.10 Decompression Screw Nos. 1.0 0.0 37.1.11 Discharge Pressure Switch Nos. 1.0 0.0 37.1.12 Nameplate, Main Nos. 1.0 0.0 37.1.13 Discharge Nozzle Nos. 1.0 0.0 37.1.14 Pneumatic Cone Reset Tool Nos. 1.0 0.0 37.1.15 Pressure Relief Damper Nos. 1.0 0.0 37.1.16 Gas Release Panel with Battery Nos. 1.0 0.0 37.1.17 Multisensor Detector Nos. 1.0 0.0 37.1.18 Hooter cum Flashers Nos. 1.0 0.0 37.1.19 Manual Release Switch Nos. 1.0 0.0 37.1.20 Abort Switch Nos. 1.0 0.0 37.1.21 Illuminated Warning Sign Board - Inside Room Nos. 1.0 0.0 37.1.22 Illuminated Warning Sign Board - Outside Room Nos. 1.0 0.0 37.1.23 Illuminated Status Board Nos. 1.0 0.0 37.1.24 2 Core 1.5 Sqmm FRLS Armoured Cable, Mtrs. 1.0 0.0 38.0 Providing, laying, testing and commissioning of carbon steel pipes including fittings like elbows, tees, nuts, bolts, gaskets etc., fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic paint of required shade complete as required.All joints upto and including 50mm dia shall be Socket Weld and Pipes above 50 mm dia shall be Butt Weld. 38.1 50NB SCH-80 Pipe for Manifold Mtrs. 1.0 0.0 38.2 50NB SCH-40 Pipe Mtrs. 1.0 0.0 38.3 40NB SCH-40 Pipe Mtrs. 1.0 0.0 38.4 32NB SCH-40 Pipe Mtrs. 1.0 0.0 38.5 25NB SCH-40 Pipe Mtrs. 1.0 0.0 38.6 20NB SCH-40 Pipe Mtrs. 1.0 0.0 38.7 15NB SCH-40 Pipe Mtrs. 1.0 0.0 38.8 Conducting Piping Pressure Test, testing & commissioning of complete flooding system Set 1.0 0.0 TOTAL FOR M-FIRE FIGHTING WORKS 0.0 SOLADEVANHALLI DEPOT - SCHEDULE N***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. S.No. Description Unit Qty. Rate (***Refer Note) Total Amount INR N -PLUMBING PUMPS AND WATER TREATMENT PLANT IMPORTANT NOTE: a) The rates will include foundations of equipments and painting of all metal parts , pipes, fittings, vessels, etc. with two coats of anticorrosive paint and two coats of enamel of approved shade and brand irrespective of whether mentioned or not. b) The Equipment's shall be on M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation in cement concrete 1:2:4 - 300mm high and 150mm projection on all side of base plate, 12mm thick cement plaster in cement mortar 1:4 finished with a floating coat of neat cement duly plastered with anti vibration pads. c) For all pressure gauges's & switches connectioned to be made with suitable Gun Metal Shut Off Cock & Syphon. d) Materials and components not specifically stated in the specifications and/or bill of materials or noted on the drawings but which are necessary for satisfactory installation and operation of the system shall be deemed to have been included in the quoted rate and scope of work without any cost implication to Engineer / Employer 1.0 Pumping System 1.1 Providing, fixing, testing and commissioning of Vertical in line type pump set with SS casing, SS impeller and SS shaft suitable for operation on 400/440 volts, 3 phase 2900 RPM, TEFC electric motor mounted on a common channel base plate with coupling guard, 150mm dia pressure gauge, GM isolation cock and cement concrete foundation with plaster complete as required. a) Filter Feed pumps - Raw Water Pumps(1w+1s) and 1 No. Pressure Vessel Set 1.0 0.0 i Pump capacity - 150 lpm ii Head - 30 m iii RPM - 2900 b) Treated water pumps - Domestic Water Pumps(1w+1s) and 1 No. Pressure Vessel Set 1.0 0.0 i Pump capacity - 150 lpm ii Head - 50 m iii RPM - 2900 c) DRAINAGE PUMP WITH STARTER Sets 10.0 0.0 The rate shall include Supply, Installation, Testing and Commissioning a set of two submersible dewatering pump of 180 lpm discharge of water at 10 m. head complete with all accessories suitable for operation on 415 V 3 phase, 50 Hz. AC supply complete with starter for automatic operation including water level sensing device, inter connection with submersible cable etc. common electrical panel with alternative operation of pumps including all cabling, wiring etc. One set will comprise two submersible pumps with all accessories. The rate will include all supports, foundation, clamps etc.(1W+1S) 2.0 Water Treatment System 2.1 Providing and fixing skid mounted vertical MSRL Dual Media pressure filter fabricated from IS 226/2062 plate 5mm thick for shell and 6mm thick M.S. plate for dished ends complete with initial charge of filter media, face piping and valves accessories, cement concrete foundation with plaster,painting, testing and commissioning complete (for domestic water supply system). Set 1.0 0.0 Capacity 9000 lph. Flow through rate 10000 lph/m2 Working pressure 2.5 kg./cm2 Design pressure 4 kg./cm2 2.2 Providing & fixing chlorination system consisting of electronic metering type dozing pump, 80W motor of working pressure 3 kg/sqcm complete including suppling and fixing of necessary polythene inter-connecting pipe of 15mm dia, PVC valves, PVC/HDPE dosing tank of 100 litres capacity. Set 1.0 0.0 2.3 Providing and fixing bulk water meter with direct reading dial in KL, all internal parts and strainer in gun metal/brass. a) 65 mm dia Set 1.0 0.0 2.4 Providing and fixing direct reading rate of flow Rota Meter a) 50mm dia for 9000 lph rate of flow Set 2.0 0.0 2.5 Providing and fixing gun metal dial type pressure gauge (150mm dia) of rating 0-10 kg./cm2 with gun metal isolating cock pig and connecting pipe. Set 1.0 0.0 2.6 Supply, assembly, erection, testing and commissioning of UV treatment unit for water supply filter (approved make). a) Suitable for flow rate 9000 lph Set 1.0 0.0 3.0 Suction And Delivery Pipes And Valves For Water Supply Pumps 3.1 Providing and fixing G.I. suction & delivery headers / pipes for water supply pumps (IS:1239 heavy class) with G.I. Fittings (bends, tees, reducers, plugs, union, flange & blank flanges etc), clamps, painting and jointing with teflon tape or hold tite including chase cutting and making good the walls, floors etc. wherever required. a) 65 mm nominal bore Mtr 102.0 0.0 b) 80 mm nominal bore Mtr 60.0 0.0 3.2 Providing and fixing lever operated gun metal ball valve with SS ball. a) 50mm nominal bore Nos 1.0 0.0 3.3 Providing and fixing C.I. wafer type Butterfly valves conforming to PN 16, BS:5155 with nuts, bolts, washers, 3mm thick insertion ruber gasket and two matching flanges etc. complete. a) 65 mm nominal bore Nos 6.0 0.0 b) 80 mm nominal bore Nos 16.0 0.0 3.4 Providing and fixing C.I. Double flanged horizontal type non-return valve of PN 16 to API:594 including nut, bolts, 3mm thick compressed asbestose, gasket, companion flanges. a) 65 mm nominal bore Nos 4.0 0.0 3.5 Providing and fixing suction strainer with M.S. flanged connection 1000mm long, fabricated from 16 gauge Brass sheet with 3mm slots. a) 100 mm nominal bore Nos 2.0 0.0 3.6 Suplly and Installation of SS Expansion Bellow a) 65 mm nominal bore Nos 4.0 0.0 b) 80 mm nominal bore Nos 4.0 0.0 TOTAL OF N-PLUMBING AND WTP WORKS 0.0 SOLADEVANHALLI DEPOT - SCHEDULE O***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. S.No. Description Unit Qty. Rate (***Refer Note) Total Amount INR O-COMPRESSED AIR SYSTEM IMPORTANT NOTE: a) The rates will include foundations of equpments and painting of all metal parts , pipes, fittings, vessels, etc. with two coats of anticorrosive paint and two coats of enamel of approved shade and brand irrespective of whether mentioned or not. b) The Equipment's shall be on M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation in cement concrete 1:2:4 - 300mm high and 150mm projection on all side of base plate, 12mm thick cement plaster in cement mortar 1:4 finished with a floating coat of neat cement duly plastered with anti vibration pads. c) For all pressure gauges's & switches connectioned to be made with suitable Gun Metal Shut Off Cock & Syphon. d) Materials and components not specifically stated in the specifications and/or bill of materials or noted on the drawings but which are necessary for satisfactory installation and operation of the system shall be deemed to have been included in the quoted rate and scope of work without any cost implication to Engineer / Employer F.01 AIR COMPRESSOR WITH ACCESSORIES & COMPRESSED AIR PIPING 1.0 GENERAL a) The BOQ specified below include the latest relevent standards, specifications, drawing details and the contractor is required to go through them as referred in tender document while quoting the rates. All the samples/ material intended to be used in the works shall be subject to approval before use as the Employer's representative may opt. b) The description as mentioned in BOQ, specifications, special conditions, GCC drawing and the conditions mentioned therein whichever is stringent shall be applicable, acceptable and complied with. c) Sub-letting of work by the contractor shall only be permitted in accordance with Special Conditions of Contract. d) The items indicating zero quantity can also be operated and variation clause shall be applicable as stipulated in GCC / SCC. e) Contractor's shall quote resonable rates against each item of BOQ (both in word and figure) 1.1 Compressor With Air drier for Inspection Bay, Internal Cleaning Shed, PWL(1w + 1s)- 170cfm Nos. 2.0 0.0 Designing, Supply, installation ,testing and commissioning of air compressor capacity 170 CFM at 10 bar with 30 KW Electrical motor 3 Phase 440 Volts complete with all accessories along with Electrical Control panel, acoustic enclosure with appropriate IP, necessary wiring , earthing,reservoir tank of 1500 litres capacity with apropriate inlet and outlet flanges designed for full rated capacity of 2 compressors, with all safety requirements etc. complete in all respects and as per technical specifications. 1.2 Compressor With Air drier for RBL(1w + 1s)- 55cfm Nos 1.0 0.0 Designing, Supplying, Installing, testing and commissioning of air compressor capacity 55 CFM at 10 baar with 11 KW Electrical motor 3 Phase 440 Volts complete with all accessories along with Electrical control panel, necessary wiring, earthing ,reservoir tank of 800 litres capacity with apropriate inlet and outlet flanges designed for full rated capacity of 2 compressors with all safety requirements etc. complete in all respects and as per technical specifications. etc. complete in all respects and as per technical specifications. 1.3 GI Pipes Supplying, installing, testing and commissioning of GI pipes conforming to IS 1239 (Class C) and B3589 complete with all fittings such as elbows, sockets, tees, unions, reducers, flanges, clamps and plugs etc with threading, jointing and making connections including cutting hole in wall/floor/slab and making good the same with cement concrete 1:2:4 complete in all respect as per specifications including painting pipe and fittings with two or more coat of synthetic enamel paint of approved quality colour over a coat of red oxide primer outside with 1 coat of primer and 2 coats of enamel paint, complete. 1.3.1 100 mm dia nominal bore RM 300.0 0.0 1.3.2 65 mm dia nominal bore RM 1800.0 0.0 1.3.3 25 mm dia nominal bore RM 680.0 0.0 1.4 M.S. structural work Supplying, installing, testing and commissioning of M.S. structural work, fabricated from standard sections eg. M.S. rods, angles channels including cutting to size, drilling holes, fixing fasteners/insert plates in RCC structural members as directed by the Engineer-in-Charge including cutting and making good the walls and floors (for supports, clamps, M.S. ladders, gratings etc.) Kgs 2200.0 0.0 1.5 Gunmetal Ball Valve Supplying, installing, testing and commissioning of gunmetal ball value with Stainless Steel ball & teflon seats and seals inside spindle type tested to 35 kg/sq cm, complete. 1.5.1 25 mm dia nominal bore Nos 100.0 0.0 1.6 Non Return Valves Supplying, installing, testing and commissioning of Wafer Type, Cast Steel, Non Return Valves, and Suitable for ASA 150 flanges (American Standard for Air). 1.6.1 Size 100 mm dia nominal bore Nos 7.0 0.0 1.6.2 Size 65 mm dia nominal bore Nos 10.0 0.0 1.7 Cast Iron Body-Butterfly Valve Supplying, installing, testing and commissioning of cast iron body PN 16, IS: 210 FG 220 and double flange simple operation type butterfly valve conforming to IS: 13095 with SS304 disc and shaft nitnile rubber replaceable seat of the following size complete with bolts, nuts, washers and rubber insertions as per specification. 1.7.1 100 mm dia nominal bore Nos 15.0 0.0 1.7.2 65 mm dia nominal bore Nos 20.0 0.0 1.8 Pressure Gauges Supplying, installing, testing and commissioning of Pressure Gauges, 150 mm Dial, complete with mounting nipple and isolation valve. Range 0 - 15 Kg/ sqcm. Nos 30.0 0.0 1.9 Auto Drain Assembly Supplying, installing, testing and commissioning of Auto Drain Assembly, with Solenoid Valve and Timer. Timer should be adjustable between 5 Mins to 120 Mins. Size 15 mm nominal bore. Nos 20.0 0.0 1.1 Filter regulator Supplying, installing, testing and commissioning of Filter regulator 1/2\\" at every droplet after the ball valve suitable for 10 Kg/ sq.cm pressure with all accessories. Nos 85.0 0.0 TOTAL FOR O-COMPRESSED AIR SYSTEM WORKS 0.0 SOLADEVANHALLI DEPOT - SCHEDULE P***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. S.No. Description Unit Qty. Rate (***Refer Note) Total Amount INR P-Local Area Network (LAN) IMPORTANT NOTE: A Materials and components not specifically stated in the specifications and/or bill of materials or noted on the drawings but which are necessary for satisfactory installation and operation of the system shall be deemed to have been included in the quoted rate and scope of work without any cost implication to Engineer / Employer. 1.0 Supply, Installation, testing and commissioning of Local Area Network System, in accordance to the Technical Specification Design & providing all stages of drawings and installation, testing and commissining as given below. 1.1 4 pair Cat-6 23 AWG U/UTP cable RM 31000.0 0.0 1.2 Cat-6 I/O Toolless Termination with Shutter, 2 module face plate / Dual Face plate along with Back Box (1data & 1 Redundancy) Nos 540.0 0.0 1.3 Cat-6 Patch cord (7 feet) Nos 280.0 0.0 1.4 Cat-6 Patch cord (3 feet) Nos 280.0 0.0 1.5 Cat-6 modular 24 port Jack Pannel Front Loading- Loaded with I/O's Toolless Termination Nos 24.0 0.0 1.6 15U wall mount network rack with glass door, cooling fan assembly, power distribution board, Hardware Pkt., wire manager & earthing arrangement etc. Set 18.0 0.0 1.7 18U wall mount network rack with front & rear glass door, cooling fan assembly, power strip / distribution board, monitor tray, Hardware Pkt., wire manager, with shelf , fans , castor set & earthing arrangement etc. Set 1.0 0.0 1.8 42 U rack with standard accessories for patch pannels,switches & servers Nos 4.0 0.0 1.9 1U card manager for Dressing Nos 42.0 0.0 1.1 Outdoor Single Mode 6 core Armored Optic Fibre cable single mode RM 12500.0 0.0 1.11 Single Mode Pigtails (LC) to terminate fiber to LIU frame Nos 290.0 0.0 1.12 Single Mode 24port fibre optic LIU loaded with LC coupler Nos 18.0 0.0 1.13 Duplex Single Mode LC-LC fibre patch cord (2mtr Length) Nos 285.0 0.0 1.14 9U rack for stations Nos 14.0 0.0 1.15 Supply & Installation of 50 / 38 mm dia pre lubricated telecom HDPE duct. RM 9600.0 0.0 1.16 Supply & Installation of 40/33 dia pre lubricated telecom HDPE duct. RM 2230.0 0.0 1.17 Supply & fixing of GI box for I/O plate Nos 580.0 0.0 1.18 PVC casing & caping 1 inch RM 1000.0 0.0 1.19 PVC casing & caping 2 inch RM 380.0 0.0 1.2 100 X 50 MM PVC trough RM 100.0 0.0 1.21 2 Inch pvc Flexible pipe RM 100.0 0.0 1.22 1 Inch Flexible pipe RM 100.0 0.0 1.23 PVC sleeve for fiber cables RM 750.0 0.0 1.24 PVC gang box Nos 280.0 0.0 1.25 Supply & Installation of SC Connector including termination of fibre on connector. Nos 108.0 0.0 1.26 24 Port Gigabyte Managed Switch with optical Fibre port ( CISCO 2960/E 24TCL 10/100/1000) or equivalent Nos 9.0 0.0 1.27 Switch with optical Fibre port CISCO 3750/12/55 SFP Std Multilayer ( or equivalent) Nos 1.0 0.0 1.28 Supply 1000 BASE-LX/LH SFP (Model No.GLC-LH-SM) Nos 4.0 0.0 TOTAL FOR P-LAN SYSTEM 0.0 SOLADEVANHALLI DEPOT - SCHEDULE Q***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. S.No. Description Unit Qty. Rate (***Refer Note) Total Amount INR Q-ACCESS CONTROL SYSTEM Note : Access Control System should be in accordance to the Technical Specification. Materials and components not specifically stated in the specifications and/or bill of materials or noted on the drawings but which are necessary for satisfactory installation and operation of the system shall be deemed to have been included in the quoted rate and scope of work without any cost implication to Engineer/Employer. 1.0 Supply, Installation, testing and commissioning of Access Control System, in accordance to the Technical Specification 1.1 Access control IRIS recognition device ( Matrix Bio Metric and Door Access Controller Fingerprint , Face and Card based Time-Attendance Terminal , DOOR Release EXIT PUSH Button, DOUBLE DOOR ELECTRO MAGNETIC LOCK, L-U BRACKET for Lock fixing) With Administrative Software license, Add on reader with administrator licence Set 2.0 0.0 1.2 Visitor management software for issuing temporary cards for visitors Set 1.0 0.0 1.3 Smart cards Nos 82.0 0.0 TOTAL FOR Q-ACCESS CONTROL SYSTEM 0.0 SOLADEVANHALLI DEPOT - SCHEDULE R***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. S.No. Description Unit Qty. Rate (***Refer Note) Total Amount INR R-CIVIL WORKS EXTERNAL PIPING SYSTEM (HUME, TRENCHING & UNDERGROUND) Note: Any extra civil work needs to be done with permission of Engineer, will be paid extra. Quantity will be as per actual and prices will be as per latest year Karnataka Schedule of Rates/Engineer / Employer Civil LAR. 1.0 PIPES 1.1 HDPE Pipe Supply and laying of following HDPE pipe NP4 grade under paved areas/track crossings including necessary excavation, honching and back filling complete as required as per IS:14333:1996 with all amendments applicable. 1.1.1 250 mm dia HDPE Pipe M 4070.0 0.0 1.1.2 160 mm dia HDPE Pipe M 10000.0 0.0 1.1.3 80 mm dia HDPE Pipe M 1000.0 0.0 1.2 Heavy Grade GI Pipes Supply and installation of following heavy duty grade GI pipes for cables crossing the rail tracks with all bendings complete as required including necessary excavation, honching and back filling as complete as required as per IS:3589 & IS 1239 with all amendments applicable, 1.2.1 150 mm dia GI pipe M 50.0 0.0 1.2.2 100 mm dia GI pipe M 50.0 0.0 1.2.3 80 mm dia GI pipe M 290.0 0.0 1.2.4 40 mm dia GI pipe M 50.0 0.0 1.3 RCC Hume Pipes Supply and installation of following RCC Hume pipes NP4 grade, for cables crossing the roads with all fitting accessories complete as required including necessary excavation, honching and back filling as compete as required as per IS:458: 2003 with all amendments applicable. 1.3.1 450mm dia RCC Pipe M 50.0 0.0 1.3.2 300mm dia RCC Pipe M 350.0 0.0 1.3.3 150mm dia RCC Pipe M 350.0 0.0 1.4 CABLE TROUGHS. Manufacture and supply of cement concrete pre cast cable trough with twin and single cell using TMT reinforcement/mild steel bar and M40 grade concrete with pre-cast concrete cover slab for stations, ramps, viaduct, cross over locations and jumper location etx for traction, signal and telecom cable arrangement . Rate shall also include the cost of required dosage and admixture in concrete for obtaining required workability as per specification and approval of engineer. The cost shall be inclusive of the cost of moulds for pre-cast cable trough work, providing lifting hooks in the cable trough work, providing lifting hooks in the cable trough and also to the slabs, casting facilities, curing arrangements, all handling, loading, unloading, stacking at site, smooth finishing to the exposed surfaces, pointing etc. Complete with all materials, labours, tools and plants, machineries, complete as per approved drawing, specifications and direction of engineer.Note1: Cost of TMT reinforcement steel, mild steel bars or pre-fabricated cages used in the work shall be measured and paid separately under item 2.Note 2: The quoted price is inclusive of colour finishing if required and nothing shall be payable on this account. 1.4.1 Twin cell cable trough of internal dimension of 350*160mm and 150mm*160mm M 2000.0 0.0 1.4.2 Single cell cable trough of internal dimension of 350mm*160mm M 3000.0 0.0 TOTAL of Schedule R 0.0 SOLADEVANHALLI DEPOT- BOQ - SCHEDULE S***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. SI.No. Description of Item Unit Qty Rate (***Refer Note) Amount (Rs.) INR SCHEDULE- S BILL OF QUANTITIES FOR M&P WORKS |
| 406 | CRANES |
| 407 | Supply, Installation, Testing and commissioning of 15/5 ton Electric Overhead complete with gantry rail and downshop leads (\\" I \\" section gantry girders shall be provided by building structural contractor) as per specification in Workshop bay span 32 m / as per approved drawings |
| 408 | Supply, Installation, Testing and commissioning of 2 ton Electric Overhead complete with gantry rail and downshop leads (\\" I \\" section gantry girders shall be provided by building structural contractor) as per specification in Pit Wheel Lathe bay span 10m / as per approved drawings |
| 409 | Supply, Installation, Testing and commissioning of 5 ton Electric Overhead complete with gantry rail and downshop leads (\\" I \\" section gantry girders shall be provided by building structural contractor) as per specification in ETU Workshop bay span 10 m / as per approved drawings |
| 410 | Supply, Installation, Testing and commissioning of 10 ton Electric Overhead complete with gantry rail and downshop leads (\\" I \\" section gantry girders shall be provided by building structural contractor) as per specification in bogie repair shop span 19.60m / as per approved drawings Total for SCH S BILL OF QUANTITIES FOR M&P WORKS 0.0 SOLADEVANHALLI DEPOT- SCHEDULE T***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. SI.No. Description of Item Unit Qty Rate (***Refer Note) Amount (Rs.) INR SCHEDULE T :MISCELLANEOUS WORKS |
| 411 | During the contract period including the extended contract period till the final completion of the work, the contractor shall provide Surveying by establishing DGPS control points and TBMs, Marking of alignment and building locations, vertical & horizontal clearances for the elevated section including modifications, if any, as per drawings. No extra amount will be paid to re- do or to re-establish any of the survey points. The control points are to be fixed using DGPS double frequency and the accuracy of 1 in 50,000 or better are to be assured.Note: The payment schedule for the item shall be as follows: (i) Payment at 25% of total cost of the item on checking and verification of all control points and submission of drawings. (ii) Payment at 70% of total cost of the item equally distributed over the duration of the contract period and will be paid on pro-rata basis. (iii) Payment at 5% of total cost of the item on satisfactory completion of work along with the final bill. |
| 412 | Providing temporary barricade of 2m height of plain MS sheet 16 Gauge fixed with steel frame as per drawing, painting (including primer of approved quality) with all leads & lift at all levels with synthetic enamel paint of approved colour, quality and brand writing lettering and logo of BSRP / KRIDE including maintenance of the same duly cleaning the same ; on fortnightly basis and painting if required, arrangement for blinker lights on barricades during night ·as per requirement and as per the instruction of the engineer. Barricading should be rugged. During the construction, barricading has to be kept continuously. Nothing extra will be paid for dismantling and re erecting the barricades at the same place. There should not be any opening at the end of barricade except at locations approved by Engineer.Note: (i) Once barricade has been provided and work started, removal of barricade is not permitted till completion of pile, pile cap till completion of construction.(ii) While erecting barricade, the bottom gap between barricade and road should be plugged with cement concrete from inside.(iii) Adequate blinking lights oh barricade during night time must be ensured. The cost of this item should include provision for power pack / Generator Set etc. so as to ensure the blinking of lights in night time as long as barricades are in position at the work spot.(iv) After completion of the entire work, the barricades shall be the property of the contractor. (v) Payment shall be made at 70% on erection of barricade and 30% on removal of barricade as per the instructions of Engineer.(vi) If the cleaning is not done including removal of posters regularly, a recovery shall be made at the rate of 0.1% of the accepted rate of item per fortnight on pro-rata basis of length not cleaned. |
| 413 | IR Barricading Board Vetted rate of YPR-CSDR Section Vide Tender No. K-RIDE/DL/18/2022, Dt. 10.10.2022-Providing safety barricading as per drg. No. SWR/CN/BNC/SK/165-2018/R with contractor's materials and labour including all leads and lifts complete as directed by Engineer in charge.(Size 100 mm x 1650 mm Rcc pole) Note: 1. Casting of RCC pillars shall be carried out in nominated depot and submerged water curing. 2. The precast RCC posts shall be transported to date duly handling carefully without causing any damage and errect it at nominated locations as per deg duly ensuring safety of running trains. 3. Maintenance of the rope, RCC pillars etc shall be at the cost of contractor. 4. 90% of the payment shall be released after erecting fencing to the satisfaction of Engineer in charge. |
| 414 | Submitting colour photographs of the works as directed by the engineer at intervals as instructed by the engineer. One Set shall comprise of 25 photographs in 3 copies each of size not less than 225mm x 175mm each in album form, apart from 3 soft copies of all photographs on DVD. The photographs chosen should cover important activities of the work. |
| 415 | Supply of video DVDs of 180 minutes duration comprising one master copy and two I extra copies duly edited titled showing the progress of works and methodology and at interval as directed by the engineer. One Set consists of one master copy and two extra copies. |
| 416 | Conducting plate load test with 600mm x 600mm x 25mm thick plate at foundation level or at the depth specified by the Engineer to determine the bearing capacity and load Settlement char;::icteristics of soil as per relevant Indian Standards and specifications up to 800 KN/sqm or failure including all equipment, materials and preparation of reports. The quoted rates are inclusive of excavation of test pit and preparation of the surface for test. The minimum test pit size is 3m x 3m up to .the proposed founding level to be excavated and all suitable precautions to be taken while carrying out the excavation. The dewatering shall be done at the cost of contractor and the ground water table shall be lowered and maintained at the test depth for the entire duration of the test.Unless otherwise specified the Kentledge/ reaction method of loading shall be adopted. Settlement shall be recorded from dial gauges placed at four diametrically opposite ends of the test plates and the test plates shall be 600mm x 600mm x 25mm thick. The bottom of the pit shall be levelled before placing the plate in position for conducting the test. Necessary seating load to be applied and the load shall be increased in stages up to 800KN/sqm or as directed by the Engineer. Under each loading stage record of time v/s Settlement shall be kept as specified in IS code. During unloading, reading of dial gauge shall be recorded for each stage of unloading. The rates are inclusive of backfilling the test pit and reinstating to its original conditions. |
| 417 | Deployment of adequate manpower (Traffic marshals) for management of traffic atIintersection, junctions, traffic diversions etc. at various levels to the complete satisfaction of local traffic police and as directed by engineer. Note: The traffic marshals should be familiar with traffic rules and regulations. |
| 418 | Design, build and maintaining site office fully furnished for the use of Engineer as per the layout drawing, specifications, & Employer Requirements-Scope of work.Note: (i) The site office shall be maintained up to end of final taking over certificate.(ii) Site office to be dismantled after the purpose for which it is meant.(iii) After the establishment of site office 70 % of the billed amount of this item is payable and balance 30% on pro-rata basis in proportion to contract price in IPCs.(iv) In case site office is provided on hire or lease basis the payment will be made on pro-rata basis in proportion to contract price inIPCs. |
| 419 | Uprooting the tree roots of girth beyond 300mm and upto 2400mm and disposal and filling in the place with available earth with all lead and lifts. |
| 420 | Transplanting the marked trees of various species and girth (300mm to 500mm girth) to the place shown by Engineer with all leads and lifts, tools, plants, men & machinery and necessary preparation such as: i) Preparation of earth ball of tree roots of desired depth and diameters. ii) Dislodging, lifting, transportation and transplanting tree from original place to the new place including all arrangements, labour etc. for successfully completing the work. iii) Excavating pits of adequate size, arranging loose soil, mixing of manure, fertilizer, insecticides etc. to ensure survival of the trees being transplanted. iv) Maintenance of tree ie. watering, soil heaping, spray of insecticides for six months all above operations shall be executed as per specifications. |
| 421 | Boring of 150 mm dia. (confirmatory bore holes), in all types of soil at selected locations (Locations to be decided by the Engineer) up to 3m in hard rock or 30m boring whichever is earlier and collecting core samples in rock for determination of core recovery, RQD and carrying out compressive strength test on rock samples. The rate inclusive of boring in soil, conducting SPT and collecting samples at 3m depth intervals and submitting bore log reports with soil classifications in SPT, Drilling 3m in hard rock with double barrel core for obtaining samples for testing of core recovery, RQD and compressive strength as per standardpractice, Preparation and submission of report containing core recovery, RQD, Compressive strength at Hard Rock locations with all leadand lifts and as per the directives of Engineer. |
| 422 | HORTICULTURE WORK Planting of trees by road side (Avenue trees) 0.6m dia holes, 1m deep dug in the ground, mixing the soil with decayed form yard/sludge manure, planting the samplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year complete as per specifications. MORTH Specification no.307 Each 150.0 0.0 Total of Schedule \\"T\\" 0.0 SOLDEVANAHALLI DEPOT ELEVATED TEST TRACK - SCHEDULE U***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. Itemno. Description of items Unit QTY Rate (***Refer Note) AMOUNT SCHEDULE-A1: OPEN FOUNDATIONS INR |
| 423 | Providing & laying M35/20 grade, reinforced cement concrete using Portland slag cement (Directly from manufacturer or blending of OPC+GGBS) for the following concrete works: Pile cap, Open Foundation/ Stepped Foundation/ Raft, Combined Footing, Columns, Grade beam, monopile pedestals, U/G water tank and Structures of road widening works such as foundation, substructures, and superstructures of culverts, retaining walls, return walls, precast/cast -in-situ culvert deck slabs, road median, drains, etc. including excavation up to 4.0 m from lowest ground level through existing water bound macadam road/ bituminous road/ soil/ murram/ hard rock/ soft rock old structures below ground as encountered of all thicknesses, dismantling other structures, dead utilities, dewatering, pumping and bailing out water, strutting and shoring, formwork, backfillingin foundation with good earth/quarry dust/sand watering, compacting with a vibratory plate compactor complete as per specifications. The Cost shall also include cutting/chipping of pile up to cut off level or up to good concrete and built up of pile up to required level. The cost includes loading, unloading and disposal of surplus excavated material along with pile heads using covered trucks to contractor's dumping yard with all leads and lifts and as directed by the Engineer. The contractor has to ensure that during transportation, the carried material does not spill out. Reinforcement steel shall be paid separately under relevant item. Rate shall include cost of using required dosage of admixture in concrete for obtaining required workability as per approval of Engineer, curing of concrete |
| 424 | Excavation exceeding 4m depth, for open foundations, combined footing, underground water tank, etc. in all types of soil, soft rock, hard rock, boulders, old structures below ground as encountered of all types & thickness, including dismantling of other structures, dead utilities and backfilling using good earth including watering, compacting with a vibratory plate compactor complete as per specifications and loading, leading and disposal of surplus excavated material using covered trucks to contractor's dumping yard and as directed by the Engineer so as to ensure that during transportation, the carried material does not spill out with all leads and lifts, including all supports (by sheet pile/ shoring/ strutting to retain and support the soil/ Sloped Excavation or other methods) for stability including dewatering, pumping and bailing out of water. Note: This item shall be measured on basis of area of PCC for pile cap/foundation multiplied by the excavation depth beyond 4m. |
| 425 | Providing & laying plain cement concrete M20/20 grade in open foundation, stepped foundation, combined footing, raft foundation, retaining walls, return walls, walls, U/G water tank, culverts, below pile cap, drains, slab on grade, tie beams, basements, levelling course or any other works as directed by the Engineer, etc. rate is inclusive of required dosage of admixture in concrete for obtaining required workability and as per specifications, approved drawings, laid in layers not exceeding 15cms thick layers, as per drawing including cost of all material, formwork/shuttering, dewatering during concreting, vibrating, compacting, curing, hire charges of machinery, all lead and lift, loading, unloading, transporting, stacking, finishing the exposed faces etc., complete. SCHEDULE-B1: CAST-IN-SITU/PRECAST WORK Providing and laying PCC/RCC for viaduct, road cum rail flyover, stations structures |
| 426 | Providing and laying grade M50/ 20 reinforced cement concrete at all levels for Viaduct & station piers of all size, shapes & heights (standard pier, portal pier & cantilever pier), pier head, shear key, portal beams, pier-arms, corbels, pier-ledge, diaphragms, pedestals, deck slab, cast-in-situ Pier Cap of all shapes etc. including centering, shuttering, propping, staging, scaffolding, curing, necessary tools, plants, machinery and all related operations etc. using steel shuttering & steel props. Formwork to be designed in such a way that traffic on road is allowed during the work at all times. Rate shall include cost of providing grooves, chamfers, mouldings, cut-outs, necessary fixtures, insert plates, sleeves for various purposes, shear connectors etc. complete as per drawings, specifications and as directed by the Engineer. The rate shall also include preparation of construction joints as per specification and providing approved wire mesh/weld mesh at such locations as approved by Engineer or as shown in drawings. Reinforcement steel shall be paid separately under relevant BOQ item. Rate shall also include cost of using required dosage of admixture in concrete for obtaining required workability as per specification & approval of Engineer. Note: (i) No cold joints are permitted. However cold joint at the junction of \\"pile cap - pier\\" and at the top surface of the starter of pier (which is normally less than 2m height), cold joints are unavoidable. In that case old concrete surface should have adequate shear key depressions, reinforced dowels and a layer of concrete bonding compound. Concrete retarder compound may also have to be used at the concrete surface of starter pier above the pile cap. The rate is inclusive of all above bonding agents/methods. However if any additional cold joints are unavoidable due to the reasons not beyond the control of contractor, all above bonding measures shall be on account of the contractor. (ii) The cost is included for provision of HDPE pipes for pre-stressing system in station piers as per drawings complete. |
| 427 | Providing and laying M50/20 Grade reinforced cement concrete for precast PSC I-Girder, (pi)/ T-girder (Pre-Tensioned), for standard/special spans of all types (straight as per approved GAD) in the casting yard including provision of lifting the girders from the mould and shifting the same to the stacking yard. Quoted rate shall be inclusive of all infrastructure in the casting yard, gantry cranes, moulds, casting beds, mobile cranes, stores, concrete batching plant, testing labs, bulk heads, approved curing arrangements as required, all handling etc. complete, 2mm teflon sheet at the end for placing on portal/arrangement for placing bearing with suitable downstand etc. as required and shown in drawing etc. complete. Pre-stressing strand and Reinforcement shall be paid separately under respective BOQ items. Rate shall include cost of lifting hooks and using required dosage of admixture in concrete for obtaining required workability as per approval of Engineer. Note: Type, Size and number of shutter moulds and debonding pipes (HDPE) as per requirement shall be as per the GFC drawings. Rate shall include all inserts. |
| 428 | Providing and laying M40/20 grade reinforced cement concrete for precast parapet, over Deck slab on both side of viaduct, including transition span as per the drawing in all spans (straight or curved), in the casting yard including provision of lifting the parapet from the mould and shifting the same to the stacking yard. Quoted rate shall be inclusive of all infrastructures in the casting yard, gantry cranes, moulds, shuttering, casting beds, mobile cranes, stores, concrete batching plant, testing labs, approved curing arrangements as required. The cost shall be inclusive of shuttering, scaffolding, special adjustable props for alignment of units, moulds, providing cutouts, required dosage of admixture for concrete. Quoted rate shall also inclusive of Loading, transporting precast parapets from casting yard to work site, launching and erection in position using gantry or crane complete with cast in situ stitch concrete of same grade. Bolts & inserts for fixing hand rails will be paid separately under relevant BOQ item. Reinforcement Steel shall be paid separately under relevant BOQ Items. Note: (i) Payment at 70% of accepted rate on casting, 28% on completion of erection, stitch concrete & related works and 2% will be released after handing over to the designated contractor. (ii) Cost inclusive of providing KRIDE logo in parapet as per drg. separately under relevant BOQ item. Reinforcement Steel shall be paid separately under relevant BOQ Items. Note: (i) Payment at 70% of accepted rate on casting, 28% on completion of erection, stitch concrete & related works and 2% will be released after handing over to the designated contractor. (ii) Cost inclusive of providing KRIDE logo in parapet as per drg. |
| 429 | Transporting precast Standard Pier-Caps from the casting yard / storage yard to the work site, erection in position including the cost of all temporary supports, erection equipment, lifting cranes, transporting etc, positioning and fixing on pier with cement concrete of M55/20 grade along with post tensioning as required. The weight shall be calculated assuming concrete density of 2.4t/m3. Shifting within the site/yard is the responsibility of the contractor and shall not be paid separately. Cast insitu connection concrete shall be paid as per the rate for item B.1 |
| 430 | Loading, transporting precast I-Girders, (pi)/T-Girder, pier-arm and portal beams (PSC & RCC) from casting yard to work site, launching and erection in position with cranes, including the erection and shifting of launching girder/crane, cost of all temporary supports, erection equipment, transporting, and positioning on bearings etc. The weight shall be calculated assuming concrete density of 2.4t/m3. |
| 431 | Conducting Load Testing of PSC U-Girder/I-Girder/(pi)/T-Girder, Composite steel girder of any span length as per IRC SPSl, including making all arrangement and conducting satisfactory Load testing on simply supported span erected in position on the piers at site. Arrangement for application of actual design serviceable vertical load as directed by Engineer and arrangement for measurement of deflection at various salient points of the girder and submitting a report. The details of placement, position, increment of load on the simply supported span and installation of measurement devices etc., shall be as directed by the Engineer. Note: Rate shall include submission of method statement and third party certification of the test. SCHEDULE-C1: STEEL WORKS STEEL REINFORCEMENT, PRESTRESSING & STRUCTURAL STEEL |
| 432 | Providing TMT-500 D grade steel bar reinforcement (conforming to IS:1786, HYSD Fe 500 grade) at all heights & depth including straightening bars, cutting, bending, hooking binding with approved quality 18 gauge G.I binding wire, after placing in position tying, lapping and/or welding wherever required and anchoring to the adjoining members wherever necessary as per drawings (Laps, Hooks, and Wastages shall not be measured and paid) including cost of all materials, bar bending charges, labour, lead & lifts etc., Complete as per specifications and as directed including welding involved towards stray current protection effects as per the system approved by Engineer. Note: (i) 18 gauge GI binding wire (2 ply) in diamond form at each reinforcement junction. (ii) Splices (Laps, couplers, welds etc.) not payable. (iii) Only mechanical coupler to be used for bars dia 20mm and above, couplers are to be used without extra cost. (iv) The cost quoted should cover all types of splices including stiffners hooks, spacer bar, U bar, chair, bend deduction as required and nothing extra is payable on this account. |
| 433 | Supplying and threading uncoated stress-relieved low relaxation steel conforming to IS:14268, class-2 in already positioned Precast Pier-arm, precast I-girder,(pi)/T-Girder, portal beams including Providing corrugated 2.3mm (Tolerances + 0.3mm) thick HDPE duct 107mm ID (Tolerances + 1mm), OD 124mm (Tolerances + 1mm) for 19K15 & 90mm ID (Tolerances + 1mm), OD 104mm (Tolerances + 1 mm) for 12Kl5 with couplers & vent pipes, spacers, anchorages, stressing using 19K15 or 12K15 system or any other approved pre-stressing system and grouting as per approved methodology including water testing, epoxy protection of anchorages, related operations to complete the work, with all lead and lift and as per specifications. This item shall include Providing and fixing all Strands, Corrugated HDPE Duct (including blister portion) for Laying the Strands, Required Anchorages for live & dead end and at blister portion for future pre-stressing, Stressing up to required level using all tools and equipment's & consumables. After stressing is completed, the voids in all ducts are to be grouted with non-shrink cement grout, and filling of all recess with concrete with adequate reinforcement as per drawing & specifications, all complete, as directed by the engineer. Note: (i) For payment, only pre-stressing strand (weight of pre-stressing strand, final in place) will be measured of individual girder average straight length. |
| 434 | Providing, fabricating and erecting structural steel for hand railing and other structural members for viaduct including transition span consisting of tubular and rolled sections profiled to require shape, base plates, strips and flats for structural and general engineering purposes with welded hold fasts for walk-way, earth terminal plates, insert plates with welded hold-fasts, internal threaded sleeves including MS bolts Confirming to IS-3757:1985 (Reaffirmed:2008)& IS-4000:1992 (reaffirmed:2013) (Code of practice for high strength bolts in steel structures) tightened by Torque wrench and primer coat and aluminium paint as per specification and drawing, with all lead and lifts and as per the directions of engineer.The rate shall also include required surface preparation (sand blasting). Painting of steel sections shall be done as below. (a). First coat- Primer to IS:5666. (b) Second coat- Zinc chromium paint to IS:104 (c) Third & fourth coat- Aluminium paint to IS:2339 SCHEDULE-D1: OTHER WORKS PRELIMINARIES AND GENERAL Bearings |
| 435 | Design, manufacture, supply & installation of the approved expansion joint (Omega Seal) at the site at track level under the supervision of manufacturer's representative as per specification and expected movement ( 25 to 50 mm) as mentioned in relevant GFC drgs. |
| 436 | Supply and fixing in position true in line & level, Elastomeric bearing both horizontal & vertical type of approved make, placing and fixing in location as per specification/drawings certifying to EN1337 and as directed by the engineer with CE Certification. Viaduct Drainage Works |
| 437 | Providing & fixing UPVC pipes outside the piers and pier cap/pier arm/ portal of OD 200mm, 6.00kg/Sqcm working pressure, approved make with pipe fittings (door bend, door tee, plain tee, plain bend, end cap, reducer, collar, etc.), including cost of fixing arrangement, such as clamp, anchor fasteners etc. with concrete structure, cost of scaffolding, cost of all materials, labour charges, HOM of equipment and testing complete as per drawings & specifications. |
| 438 | Fabrication & Supply of drainage spout hot dip galvanized of dimension 300mm x180mm with MS Flat 50mmx6mmx100mm long with gratings of MS Flat 25mmx6mm with spacing of 50mm c/c and MS pipe 122mm dia. verticals as per drawing including installation of the spout with all tools, plants, leads and lifts and in position in complete and as directed by the Engineer. |
| 439 | Providing and laying filter media with Granular material behind abutment, wing wall, return wall and foundation trenches as per drawing in layers not exceeding 20cms in depth, compacting deposited material by plate compactor/power rammer after duly watering to achieve the desired degree of compaction, including cost of materials, labour, hire charge of machineries, transportation, with all lead and lifts, loading, unloading etc. complete. MORTH specification: 710.1.4 of IRC: 78 & 2200. Miscellaneous Works |
| 440 | Painting pier identification number on piers & parapet inner face at different locations as directed by Engineer duly following the colour scheme including all material and labour, with all lead & lift. Final coating to be done at the time of handing over. |
| 441 | supply, fabrication and erection of cable tray supports made out of Hot dip galvanized (65 micron) GI angle / channels / flats fabricated to the required size and shape falling in the category of standard GI sections. Rate shall include cost of Anchor Fasteners and other accessories required for Installation of supports.a) GI channel section of 100 x 65 mmb) GI channel section of 75 x 75x 50 mmc) GI channel section of 50 x 50 x 40 mmd) GI L-Angle section of 75 x 75 x 8 mme) GI L-Angle section of 50 x 50 x 6 mmf) GI L-Angle section of 40 x 40 x 5 mmg) GI L-Angle section of 25 x 25 x 5 mmh) GI L-Angle section of 25 x 25 x 3 mmi) GI flat section of 75 x 10 mmj) GI flat section of 65 x 10 mmk) GI flat section of 65 x 8 mml) GI flat section of 50 x 6 mmm) GI flat section of 40 x 5 mmn) GI flat section of 25 x 5 mmo) GI flat section of 25 x 3 mm Total of Schedule U 0.0 SOLADEVANHALLI DEPOT-SCHEDULE V***Note: Bidder has to select only one currency from drop down under rate coloumn for all the items for this schedule. SI.No. Description of Item Unit Qty Rate (***Refer Note) Amount (Rs.) INR SCHEDULE U :ITEMS UNDER SCHEDULE OF RATE PUBLISHED BY GOVERNMENT DEPARTMENTS V1 Civil works, Utiltiy (all tupes of utilities), Tree cutting and other items not covered in above schedules are to be executed under Common SR for the year 2023-24 published by KPWD / IR -USSOR / CPWD DSR / BESCOM / KPTCL / BWSSB. & General Electrical works for execution and the work will be carried out as per latest SR of KPWD / IR -USSOR / CPWD DSR / BESCOM / KPTCL / BWSSB. Lump sum 1.0 42372881.0 42372881.355932206 Total of Schedule \\"V\\" 42372881.355932206 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail