| Sl. No. | Item Description |
| 1 | Polythene water storage tank of mark (e.g sintex/sinter/himgiri/gangotietc)with cover and locking system M079 |
| 2 | HDPE pipes 75mm dia M129 |
| 3 | HDPE pipes 90mm dia M130 |
| 4 | GI Pipe 50 mm dia (TATA or equivalent make) M193 |
| 5 | Jute M337 |
| 6 | G.M. Ferrules M922 |
| 7 | (i) 8 mm dia Wt. not less than 400 gms |
| 8 | (ii) 10 mm dia Wt. not less than 400 gms |
| 9 | (iii) 15 mm dia Wt. not less than 400 gms |
| 10 | (iv) 20 mm dia Wt. not less than 600 gms |
| 11 | (v) 25 mm dia Wt. not less than 900 gms |
| 12 | Stop Cocks M923 |
| 13 | (i) 15 mm brass stop cock wt. not less than 300 gms |
| 14 | (ii) 20 mm brass stop cock wt. not less than 400 gms |
| 15 | (iii) 25 mm brass stop cock wt. not less than 575 gms |
| 16 | (iv) 32 mm brass stop cock wt. not less than 850 gms |
| 17 | (v) 40 mm brass stop cock wt. not less than 1.15 kg |
| 18 | (vi) 50 mm brass stop cock wt. not less than 2.15 kg |
| 19 | (vii) 15 mm dia C.I. Body brass working part stop cock. |
| 20 | (viii) 20 mm dia C.I. Body brass working part stop cock. |
| 21 | (ix) 25 mm dia C.I. Body brass working part stop cock. |
| 22 | G.M. Full way Valve M924 |
| 23 | (i) 15 mm dia wt. not less than 300 gms without wheel |
| 24 | (ii) 20 mm dia wt. not less than 400 gms without wheel |
| 25 | (iii) 25 mm dia wt. not less than 500 gms without wheel |
| 26 | (iv) 32 mm dia wt. not less than 700 gms without wheel |
| 27 | (v) 40 mm dia wt. not less than 1.0 kg without wheel |
| 28 | (vi) 50 mm dia wt. not less than 1.4 kg without wheel |
| 29 | (vii) 65 mm dia wt. not less than 1.8 kg without wheel |
| 30 | (viii) 80 mm dia wt. not less than 2.5 kg without wheel |
| 31 | G.M. NON RETURN VALVE VERTICLE M925 |
| 32 | (i) 15 mm dia wt. not less than 150 gms |
| 33 | (ii) 20 mm dia wt. not less than 250 gms |
| 34 | (iii) 25 mm dia wt. not less than 375 gms |
| 35 | (iv) 32 mm dia wt. not less than 600 gms |
| 36 | (v) 40 mm dia wt. not less than 700 gms |
| 37 | (vi) 50 mm dia wt. not less than 1.0 kg |
| 38 | (vii) 65 mm dia wt. not less than 1.20 kg |
| 39 | (viii) 80 mm dia wt. not less than 1.50 kg |
| 40 | (ix) 100 mm dia wt. not less than 1.80 kg |
| 41 | G.M. Non Return Valve Horizontal M926 |
| 42 | (i) 15 mm dia wt. not less than 150 gms |
| 43 | (ii) 20 mm dia wt. not less than 250 gms |
| 44 | (iii) 25 mm dia wt. not less than 375 gms |
| 45 | (iv) 32 mm dia wt. not less than 600 gms |
| 46 | (v) 40 mm dia wt. not less than 700 gms |
| 47 | (vi) 50 mm dia wt. not less than 1.0 kg |
| 48 | (vii) 65 mm dia wt. not less than 1.20 kg |
| 49 | (viii) 80 mm dia wt. not less than 1.50 kg |
| 50 | (ix) 100 mm dia wt. not less than 1.80 kg |
| 51 | COCKs M927 |
| 52 | (i) 15 mm dia G.M. bib cock wt. not less than 300 gms |
| 53 | (ii) 15 mm dia brass bib cock wt. not less than 400 gms |
| 54 | (iii) 15 mm dia C.I. bib cock wt. not less than 400 gms |
| 55 | (iv) 15 mm dia C.I. Body brass working part spray painted bib cock wt. not less than 400 gms |
| 56 | (v) 15 mm dia C.I. Brass pillar cock cock wt. not less than 400 gms |
| 57 | (vi) 15 mm C.I. Plug cock ordinary |
| 58 | (vii) 15 mm C.I. push cock ordinary |
| 59 | CHROMIUM PLATED BRASS FITTINGS M928 |
| 60 | (i) C.P. Shower rose 100 mm dia |
| 61 | (ii) C.P. Shower rose 125 mm dia |
| 62 | (iii) P.V.C. Shower rose 150 mm dia |
| 63 | (iv) P.V.C Shower rose 125 mm dia |
| 64 | CONNECTION PIPE M929 |
| 65 | (i) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. |
| 66 | (ii) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. |
| 67 | (iii) 15 mm dia x 30 cm. long PVC connection pipe with brass fittings. |
| 68 | (iv) 15 mm dia x 45 cm. long PVC connection pipe with brass fittings. |
| 69 | G.I. FITTINGS (CONFORMING TO I.S. - 1879 ) ISI Marked M930 |
| 70 | [A] G.I. BEND |
| 71 | (i) 15 mm |
| 72 | (ii) 20 mm |
| 73 | (iii) 25 mm |
| 74 | (iv) 32 mm |
| 75 | (v) 40 mm |
| 76 | (vi) 50 mm |
| 77 | (vii) 65 mm |
| 78 | (viii) 80 mm |
| 79 | (ix) 100 mm |
| 80 | (x) 125 mm |
| 81 | (xi) 150 mm |
| 82 | [B] ELBOW OF THE FOLLOWING SIZES |
| 83 | (i) 15 mm |
| 84 | (ii) 20 mm |
| 85 | (iii) 25 mm |
| 86 | (iv) 32 mm |
| 87 | (v) 40 mm |
| 88 | (vi) 50 mm |
| 89 | (vii) 65 mm |
| 90 | (viii) 80 mm |
| 91 | (ix) 100 mm |
| 92 | (x) 125 mm |
| 93 | (xi) 150 mm |
| 94 | [C] TEE PLAIN OF THE FOLLOWING SIZES |
| 95 | (i) 15 mm |
| 96 | (ii) 20 mm |
| 97 | (iii) 25 mm |
| 98 | (iv) 32 mm |
| 99 | (v) 40 mm |
| 100 | (vi) 50 mm |
| 101 | (vii) 65 mm |
| 102 | (viii) 80 mm |
| 103 | (ix) 100 mm |
| 104 | (x) 125 mm |
| 105 | (xi) 150 mm |
| 106 | [D] REDUCING TEE PLAIN OF THE FOLLOWING SIZES (Taking larger dimension) |
| 107 | (i) 20 mm |
| 108 | (ii) 25 mm |
| 109 | (iii) 32 mm |
| 110 | (iv) 40 mm |
| 111 | (v) 50 mm |
| 112 | (vi) 65 mm |
| 113 | (vii) 80 mm |
| 114 | (viii) 100 mm |
| 115 | (ix) 125 mm |
| 116 | (x) 150 mm |
| 117 | [E] SOCKET PLAIN OF THE FOLLOWING SIZE (Taking larger dimension) |
| 118 | (i) 15 mm |
| 119 | (ii) 20 mm |
| 120 | (iii) 25 mm |
| 121 | (iv) 32 mm |
| 122 | (v) 40 mm |
| 123 | (vi) 50 mm |
| 124 | (vii) 65 mm |
| 125 | (viii) 80 mm |
| 126 | (ix) 100 mm |
| 127 | (x) 125 mm |
| 128 | (xi) 150 mm |
| 129 | [F] REDUCING SOCKET PLAIN OF THE FOLLOWING SIZES (Taking larger dimension) |
| 130 | (i) 20 mm |
| 131 | (ii) 25 mm |
| 132 | (iii) 32 mm |
| 133 | (iv) 40 mm |
| 134 | (v) 50 mm |
| 135 | (vi) 65 mm |
| 136 | (vii) 80 mm |
| 137 | (viii) 100 mm |
| 138 | (ix) 125 mm |
| 139 | (x) 150 mm |
| 140 | [G] UNION SOCKET OF THE FOLLOWING SIZES |
| 141 | (i) 15 mm |
| 142 | (ii) 20 mm |
| 143 | (iii) 25 mm |
| 144 | (iv) 32 mm |
| 145 | (v) 40 mm |
| 146 | (vi) 50 mm |
| 147 | (vii) 65 mm |
| 148 | (viii) 80 mm |
| 149 | (ix) 100 mm |
| 150 | (x) 125 mm |
| 151 | (xi) 150 mm |
| 152 | [H] PLUGS OF THE FOLLOWING SIZES |
| 153 | (i) 15 mm |
| 154 | (ii) 20 mm |
| 155 | (iii) 25 mm |
| 156 | (iv) 32 mm |
| 157 | (v) 40 mm |
| 158 | (vi) 50 mm |
| 159 | (vii) 65 mm |
| 160 | (viii) 80 mm |
| 161 | (ix) 100 mm |
| 162 | (x) 125 mm |
| 163 | (xi) 150 mm |
| 164 | [I] JAM NUTS OF THE FOLLOWING SIZES |
| 165 | (i) 15 mm |
| 166 | (ii) 20 mm |
| 167 | (iii) 25 mm |
| 168 | (iv) 32 mm |
| 169 | (v) 40 mm |
| 170 | (vi) 50 mm |
| 171 | (vii) 65 mm |
| 172 | (viii) 80 mm |
| 173 | (ix) 100 mm |
| 174 | (x) 125 mm |
| 175 | (xi) 150 mm |
| 176 | [J] G.I. NIPPLE OF THE FOLLOWING SIZES |
| 177 | (i) 15 mm dia x 100 mm long |
| 178 | (ii) 20 mm dia x 100 mm long |
| 179 | (iii) 25 mm dia x 100 mm long |
| 180 | (iv) 32mm dia x 100 mm long |
| 181 | (v) 40 mm dia x 100 mm long |
| 182 | (vi) 50 mm dia x 100 mm long |
| 183 | (vii) 65 mm dia x 100 mm long |
| 184 | (viii) 80 mm dia x 100 mm long |
| 185 | (ix) 100 mm dia x 100 mm long |
| 186 | [K] G.I. PIPES MIDIUM(Tata mark) OR EQUIVALENT as per IS-1239 (part-01)/2004 ISI Marked/Medium Quality |
| 187 | (i) 15 mm dia |
| 188 | (ii) 20 mm dia |
| 189 | (iii) 25 mm dia |
| 190 | (iv) 32 mm dia |
| 191 | (v) 40 mm dia |
| 192 | (vii) 65 mm dia |
| 193 | MIRRORS M931 |
| 194 | (a) Mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror including C.P. brass revolving fittings 3 mm plywood board and C.P. hinges etc. to fix the mirror |
| 195 | (b) -do- 450 mm x 300 mm -do- |
| 196 | (a) Glass shelf 600 mm x 125 mm with C.P. brass rail M932 |
| 197 | (b) -do- 450 mm x 125 mm -do- |
| 198 | (a) C.P. Brass towel rail 20 mm x 600 mm with bracket all complete M933 |
| 199 | (b) Anodized aluminum 20 mm x 600 mm towel rail complete with brackets |
| 200 | C.P. brass soap dish medium quality with screw and hinges etc. M934 |
| 201 | C.P. liquid soap solution holder M935 |
| 202 | VITREOUS WHITE GLAZED INDIAN WATER CLOSET OF Hindustan / Parry Ware / Cera / Naycer or any other equivalent make M936 |
| 203 | (a) 580 mm long |
| 204 | (b) 510 mm long |
| 205 | (c) 450 mm long |
| 206 | (d) 510 mm long White glazed fiber I.W.C |
| 207 | PAIR OF VETREOUS WHITE GLAZED FOOT REST OF Hindustan / Parryware / Cera / Naycer or any other equivalent make M937 |
| 208 | 15 liters capacity pull and let go high level C.I. cistern complete with ball cock and a pair of bracket M938 |
| 209 | (a) 12.5 liters lowdown C.I. Cistern M939 |
| 210 | (b) 10.0 liters capacity P.V.C. low design cistern |
| 211 | (a) White Glazed vitreous E.W.C with \\"P\\" trap or any other equivalent make M940 |
| 212 | (b) E.W.C with \\"S\\" trap 400 mm high of Hindustan / Parry ware / Cera / Naycear or any other equivalent make |
| 213 | (c) Black / white plastic seat for E.W.C -do- as above. |
| 214 | (a) White glazed vitreous earthen were urinal flat back of Hindustan / Parryware / Cera / Naycer or any other equivalent make 600 mm x 350 mm size M941 |
| 215 | (b) -do- squatting small 450 mm x 350 mm |
| 216 | (c) -do- squatting large 600 mm x 350 mm |
| 217 | (d) White glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm Hindustan / Parryware / Cera / Naycer or any other equivalent make |
| 218 | (e) Partition plate for urinal 25\\" x 13\\" size |
| 219 | (f) 5 liters C.I. automatic cistern with all P.V.C fittings |
| 220 | White glazed vitreous Wash Hand Basin 550 mm x 400 mm size of Hindustan / Parryware / Cera / Naycer or any other equivalent makeM942 |
| 221 | White glazed vitreous earthen ware kitchen sinks of Hindustan / Parryware / Cera / Naycer or any other equivalent make M943 |
| 222 | (a) Kitchen sink 600 mm x 450 mm x 200 mm (24\\" x 18\\" x 8\\") |
| 223 | (b) Kitchen sink 600 mm x 450 mm x 250 mm (24\\" x 18\\" x 10\\") |
| 224 | (c) Lab sink 450 mm x 300 mm x 150 mm (18\\" x 12\\" x 6\\") |
| 225 | (d) Lab sink 300 mm x 250 mm x 150 mm (12\\" x 10\\" x 6\\") |
| 226 | DRAIN BOARD M944 |
| 227 | (a) 600 mm x 450 mm (24\\" x 18\\") |
| 228 | (b) 525 mm x 450 mm (21\\" x 18\\") |
| 229 | H.C.I. Pipes M945 |
| 230 | (a) 50 mm dia single socket 6'-0\\" (with ear weight 13 kg) |
| 231 | (b) 80 mm dia single socket 6'-0\\" (with ear weight 18 kg) |
| 232 | (c) 100 mm dia single socket 6'-0\\" (with ear weight 23 kg) |
| 233 | (d) 150 mm dia single socket 6'-0\\" (with ear weight 30 kg) |
| 234 | (e) 50 mm dia double socket 6'-0\\" (with ear weight 14 kg) |
| 235 | (f) 80 mm dia double socket 6'-0\\" (with ear weight 19 kg) |
| 236 | (g) 100 mm dia double socket 6'-0\\" (with ear weight 25 kg) |
| 237 | (h) 150 mm dia double socket 6'-0\\" (with ear weight 13 kg) |
| 238 | (i) 50 mm dia single socket 3'-0\\" (with ear weight 7.25 kg) |
| 239 | (j) 80 mm dia single socket 3'-0\\" (with ear weight 10.5 kg) |
| 240 | (k) 100 mm dia single socket 3'-0\\" (with ear weight 13.75 kg) |
| 241 | (l) 150 mm dia single socket 3'-0\\" with ear |
| 242 | (m) 50 mm dia single socket 2'-0\\" (with ear weight 5.35 kg) |
| 243 | (n) 80 mm dia single socket 2'-0\\" (with ear weight 8.00 kg) |
| 244 | (o)100 mm dia single socket 2'-0\\"(with ear weight 10.10 kg) |
| 245 | (p) 150 mm dia single socket 2'-0\\" with ear |
| 246 | (q) 50 mm dia single socket 1'-0\\" (with ear weight 3.4 kg) |
| 247 | (r) 80 mm dia single socket 1'-0\\"(with ear weight 5.50 kg) |
| 248 | (s) 100 mm dia single socket 1'-0\\"(with ear weight 7.60 kg) |
| 249 | (t) 150 mm dia single socket |
| 250 | H.C.I. FITTINGS. M946 |
| 251 | (I) Plain bend of following size |
| 252 | (a) 50 mm dia (weight without ear and socket 2.75 kg) |
| 253 | (b) 80 mm dia (weight without ear and socket 3.5 kg) |
| 254 | (c) 100 mm dia (weight without ear and socket 4.5 kg) |
| 255 | (d) 150 mm dia (weight without ear and socket 4.5 kg) |
| 256 | (II) Bend with door with following size |
| 257 | (a) 50 mm dia (Wight without ear and socket 2.75 kg) |
| 258 | (b) 80 mm dia (Wight without ear and socket 4.00 kg) |
| 259 | (c) 100 mm dia -do- 5.5 kg |
| 260 | (d) 150 mm dia -do- |
| 261 | (III) Single Junction with door of followings sizes. |
| 262 | (a) 50 mm dia (weight without ear and socket 3.75 kg) |
| 263 | (b) 80 mm dia (weight without ear and socket 6.50 kg) |
| 264 | (c) 100 mm dia -do- 9.50 kg |
| 265 | (d) 150 mm dia -do- |
| 266 | (IV) Double junction with door of following sizes. |
| 267 | (a) 50 mm dia -do- 4.5 kg |
| 268 | (b) 80 mm dia -do- 7.00 kg |
| 269 | (c) 100 mm dia -do- 13.00 kg |
| 270 | (d) 150 mm dia -do- |
| 271 | (V) Heel rest bend of following sizes |
| 272 | (a) 50 mm dia |
| 273 | (b) 80 mm dia |
| 274 | (c) 100 mm dia |
| 275 | (d) 150 mm dia |
| 276 | (VI) Cowel of following sizes |
| 277 | (a) 50 mm dia (weight without ear and socket 2.25 kg) |
| 278 | (b) 80 mm dia (weight without ear and socket 3.25 kg) |
| 279 | (c) 100 mm dia (weight without ear and socket 3.25 kg) |
| 280 | (d) 150 mm dia -do- |
| 281 | (VII) 100 mm dia \\"P\\" trap (wt without ear and socket)8.5 kg |
| 282 | (VIII) 100 mm dia \\"P\\" trap (wt without ear and socket)8.8 kg |
| 283 | (IX) 100 mm x 80 mm floor trap (weight without ear and socket) 4.00 kg |
| 284 | (X) Pass over 50 mm x 150 mm for 50 mm projection |
| 285 | (XI) -Do- 100 mm x 150 mm for 100 mm projection |
| 286 | (XII) Inverted Junction single 100 mm x 50 (weight without ear and socket) 9.0 kg |
| 287 | (XIII) Inverted Junction double 100 mm x 50 mm x 50 mm(weight without ear and socket) 12.0 kg |
| 288 | (XIV) H.C.I. offset 80 mm projection of the following Size |
| 289 | (a) 50 mm dia (weight without ear and socket) 2.75 kg |
| 290 | (b) 80 mm dia -do- 3.50 kg |
| 291 | (c) 100 mm dia -do- 5.00 kg |
| 292 | (d) 150 mm dia -do- |
| 293 | (XV) H.C.I. Socket of following sizes |
| 294 | (a) 50 mm dia (weight without ear) 1.50 kg |
| 295 | (b) 80 mm dia (weight without ear) 3.00 kg |
| 296 | (c) 100 mm dia (weight without ear) 4.50 kg |
| 297 | (d) 150 mm dia (weight without ear) -do- |
| 298 | C.I. Cover with frame for manhole and inspection chamber M947 |
| 299 | (a) 600 mm x 450 mm size (wt. 39 kg) |
| 300 | (b) 600 mm x 450 mm size (wt. 25 kg) |
| 301 | (c) 500 mm x 450 mm size (wt. 25 kg) |
| 302 | C.I. Bracket pair for W.H.B M948 |
| 303 | (a) 550 mm x 400 mm size (22\\" x 16\\") |
| 304 | (b) -do- for 12.5 liter cistern |
| 305 | (c) -do- for 600 mm x 450 mm (24\\" x 18\\") sink |
| 306 | (d) 40 mm x 60 mm MS Plate bracket for sink as above |
| 307 | (a) 32 mm (1 1/4\\") C.P. Brass waste for W.H.B M949 |
| 308 | (b) 40 mm (1 1/2\\") C.P. Brass waste for W.H.B for sink |
| 309 | (c) 32 mm (1 1/4\\") C.P. waste of white metal |
| 310 | (d) 40 mm (1 1/2\\") C.P. waste of white metal |
| 311 | (a) 32 mm (1 1/4\\") P.V.C. waste pipe 750 mm long (2'6\\" long) with brass Union for W H B M950 |
| 312 | (b) 40 mm (1 1/2\\") P.V.C. waste pipe 750 mm long (2'6\\" long) with brass Union for W H B |
| 313 | 32 mm (1 1/4\\") P.V.C. telescopic flush pipe with brass union for high level cistern M951 |
| 314 | Rubber Inserttion 3 mm (1/8\\") thick M952 |
| 315 | Pig Lead M953 |
| 316 | Yarn M954 |
| 317 | Rubber Gasket for C.I pipe of Good quality M955 |
| 318 | (a) 80 mm |
| 319 | (b)100 mm |
| 320 | (c)125 mm |
| 321 | (d)150 mm |
| 322 | (e)200 mm |
| 323 | (f)250 mm |
| 324 | (g)300 mm |
| 325 | (h)350 mm |
| 326 | (i)400 mm |
| 327 | (j)450 mm |
| 328 | (k)500 mm |
| 329 | (l)600 mm |
| 330 | (m)700 mm |
| 331 | (n)750 mm |
| 332 | (o)800 mm |
| 333 | (p)900 mm |
| 334 | (q)1000 mm |
| 335 | (r)1200 mm |
| 336 | Cotton waste M956 |
| 337 | Asbestos Suta (gland packing) M957 |
| 338 | Solvent Cement M958 |
| 339 | Hydrocloric acid (Sepecific gravity 1.20) M959 |
| 340 | CP & PVC Fitting M960 |
| 341 | (i)32 mm dia C.P. Waste |
| 342 | (ii)32 mm dia PV C waste pipe 750 mm long with coupling |
| 343 | (iii)40 mm dia C.P. waste |
| 344 | (iv 40 mm dia PVC waste pipe 750 mm long with coupling |
| 345 | (v 100 mm dia steel jali |
| 346 | (vi)15 mm dia C.P. nipple with coupling (short pieces) |
| 347 | (vii)50 mm dia PVC pipe with coupling |
| 348 | Special type of C.P. Bath room fittings for V.I.P. buildings(JAL, Jaquar, Marc or equivalent mark) M961 |
| 349 | (i) Pillar Cock (ISI) |
| 350 | (ii) Pillar Cock (Long neck) |
| 351 | (iii) Bib Cock (ISI) |
| 352 | (iv) Bib Cock (Long Thread) |
| 353 | (v) Angular Stop Cock |
| 354 | (vi) Angular Stop Cock (Long Thread) |
| 355 | (vii) Concealed stop cock reduce (ISI) |
| 356 | (viii) Concealed stop Cock heavy-duty extra adjustable wall flange |
| 357 | (ix) Long Body Bib Cock |
| 358 | (x) Swan Neck Tap with left hand Operating Knob |
| 359 | (xi) Central hole basin mixer (Best Quality) |
| 360 | (xii) Wall mixer with telephonic shower arrangement |
| 361 | (xiii) Wall mixer with provision for over head shower with elbow coupling and well flange |
| 362 | (xiv) Wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange |
| 363 | (xv) Sink mixer with swinging casted spout |
| 364 | (xvi) Sink Cock with swinging casted spout |
| 365 | (xvii) 4 - way diverter for concealed fittings |
| 366 | (xviii) Pressure adjustable shower with revolving joint |
| 367 | (xix) Telephone shower with flexible pipe |
| 368 | (xx) Flush Cock with wall flange (25 mm) |
| 369 | (xxi) Towel Rail 24\\" |
| 370 | (xxii) Towel Ring |
| 371 | (xxiii) Soap dish |
| 372 | (xxiv) Tumbler Holder |
| 373 | (xxv) Toilet Paper Holder |
| 374 | (xxvi) Glass Shelf 22\\" |
| 375 | (xxvii) Corner glass shelf with bracket |
| 376 | (xxviii) Flush Valve complete with 32 mm size control cock & flange |
| 377 | C.I Special & PVC Pipes M962 |
| 378 | 1. C.I double shocketted fittings bend such as bend, tee, taper, |
| 379 | (a) 80-200 mm |
| 380 | (b) 250-700 mm |
| 381 | (c) 700-1000 mm |
| 382 | 2. C.I double flange fittings such as tee, taper, tailpiece, bend etc |
| 383 | (a) 80-200 mm |
| 384 | (b) 250-700 mm |
| 385 | (c) 700-1000 mm |
| 386 | Spare parts of Hand Pump |
| 387 | Hexagonal Bolt M12x1.75x40mm long common to Marks II & III M963 |
| 388 | Hexagonal Nut M12x1.75mm M964 |
| 389 | Washer M12 (2.5mm thick) M965 |
| 390 | High tensile bolt M10x1.5x40mm long. M966 |
| 391 | Nyloc Nut M10x1.5mm M967 |
| 392 | Handle Axle (Stainless Steel) M968 |
| 393 | Washer for Handle Axle (4mm thick) M969 |
| 394 | Ball Bearing 6204 Z M970 |
| 395 | Spacer for Handle. M971 |
| 396 | Chain with coupling. M972 |
| 397 | Hexagonal Bolt for front Cover M12x1.75mm long. M973 |
| 398 | Nitrile Rubber cup washer for Mark โ II & III M974 |
| 399 | Nitrile Sealing ring Mark โ II M975 |
| 400 | Nitrile Rubber Seating Big for Lower valve Mark-II M976 |
| 401 | Nitrile Rubber Seating Small for Upper valve Mark-II. M977 |
| 402 | Hexagonal rod coupling M12x1.75x50mm long. M978 |
| 403 | Pump Head Assembly (G.I.) with front cover, Bolt & third plate. M979 |
| 404 | Front cover (G.I.) M980 |
| 405 | Handle Assembly (G.I.) M981 |
| 406 | (a) Water Tank Assembly for Mark โ II (G.I.) M982 |
| 407 | (b) Water Tank Assembly for Mark โ III (VLOM-65) |
| 408 | Stand Assembly (G.I.) Normal. M983 |
| 409 | Stand Assembly (Telescopic) (G.I). M984 |
| 410 | Connecting Rod 3mtr. Long with coupling and nut (Electrogalvanized) M985 |
| 411 | a) Cylinder Assembly complete set for Mark-II M986 |
| 412 | b) Cylinder Assembly complete set for Mark-III (VLOM-65) |
| 413 | a) Upper valve Assembly complete set for India Mark-II M987 |
| 414 | b) Upper valve Assembly complete set for India Mark-III (VLOM-65) |
| 415 | a) Lower valve Assembly complete set for India Mark-II M988 |
| 416 | b) Lower valve Assembly complete set for IM-III |
| 417 | Reducer Cap for Cylinder Mark-II M989 |
| 418 | a) Plunger Rod (S.S.) for Mark โ II M990 |
| 419 | b) Plunger Rod (S.S.) for Mark โ III |
| 420 | Upper valve Guide (G.M.). M991 |
| 421 | Rubber Seat Retainer for Mark-II M992 |
| 422 | Third Plate for Head Assembly (Galanized) M993 |
| 423 | Cylinder Body with brass liner for IM-II with reducer cap for Top and Bottom. M994 |
| 424 | Gun Metal Spacer. M995 |
| 425 | Check valve Guide Mark-II M996 |
| 426 | a) Check Valve Seat for Mark โ II M997 |
| 427 | b) Check Valve Seat for Mark โ III |
| 428 | Nitrile Rubber โOโ ring (VLOM-65) M998 |
| 429 | Push Rod for Mark โ III (S.S). M999 |
| 430 | Check Nut for Push Rod (S.S.). M1000 |
| 431 | Nitrile Rubber Cup Washer for VLOM-50 M1001 |
| 432 | Nitrile Rubber Sealing Ring for Mark โ III VLOM-65 M1002 |
| 433 | Nitrile Rubber Seating Big for Lower Valve MK-II M1003 |
| 434 | Nitrile Rubber Seating Big for Lower Valve M-III VLOM-65) M1004 |
| 435 | Nitrile Rubber Bobbin VLOM-50 M1005 |
| 436 | Nitrile Rubber โOโ Ring VLOM-50 M1006 |
| 437 | Nitrile Rubber cone for VLOM-50 M1007 |
| 438 | Nitrile Rubber cone for VLOM-65 M1008 |
| 439 | Nitrile Rubber Centralizer 150mm for (VLOM-65). M1009 |
| 440 | Nitrile Rubber Centralizer 125mm for (VLOM-65). M1010 |
| 441 | Nitrile Rubber Centralizer 150mm for (VLOM-50). M1011 |
| 442 | Nitrile Rubber Centralizer 125mm for VLOM-50 M1012 |
| 443 | Nitrile Rubber Centralizer 100mm for VLOM-50 M1013 |
| 444 | Water Tank Assembly Mark โ III VLOM-50 M1014 |
| 445 | Cylinder Assembly Complete set for Mark โ III (VLOM-50) M1015 |
| 446 | Upper valve Assembly complete set for IM-III (VLOM-50) M1016 |
| 447 | Lower valve Assembly complete set for IM-III (VLOM-50) M1017 |
| 448 | a) Upper Cap Cylinder Mark โ III (VLOM-65) M1018 |
| 449 | b) Upper Cap Cylinder Mark โ III (VLOM-50) |
| 450 | a) Bottom Cap for Mark โ III (VLOM-50) M1019 |
| 451 | b) Bottom Cap for Mark โ III (VLOM-65) |
| 452 | Follower for IM-III M1020 |
| 453 | Cage for Mark-III M1021 |
| 454 | S.S. Hexagonal Bolt M-6x25mm long. M1022 |
| 455 | Basic rate of standard I.S.I. mark Deep Well Hand Pump for India mark-2, I.S.I. 15500 (Part 2) / 2004 with latest revision including 12mm x 3meter long 8 no. Connecting Rods made of bright bar electro-galvanized fitted with coupler & normal stand assembly ecommended for use with cylinder assembly suitable for bore well dia 100 to 125mm casing pipe. M1023 |
| 456 | Basic rate of UPVC pipe 125mm dia conforming to I.S.I. latest revision is 12818/2016 CML No. 5543459 M1024 |
| 457 | Basic rate of 32mm G.I. pipe in 3 mtrs. Length (medium) with seamless socket as per relevent B.I.S. specification IS 1239(PART-I)/2004 M1025 |
| 458 | DI Pipe : Providing and Supplying ISI mark Centrifugally cat (Spun) Ductile Iron Pipes of 100 mm and above all diameter for water works with socket & spigot ends confirming to IS 8329/2000 in the standard working lengths of 4.5, 5.5 & 6 m suitable for classification K-7 & K-9 suitable for push-on-joint (rubber gusket D jointing) with cement mortar lining inside the pipes with outside zinc and bittuminous coating. Rates are ex factory excluding transpotion, taxes & duties, Contractor profit & overhead charges etc.Based on WPI 100.3 of May 2020(Including cost of one no. gasket for each pipe) M1026 |
| 459 | Note :(i)The rates are exfactory but exclusive of GST & C.P. based on WPI 100.3 of May 2020. (ii) Price variation of DI pipe will be calculated based on prevalling WPI. |
| 460 | 100 mm dia |
| 461 | 150 mm dia |
| 462 | 200 mm dia |
| 463 | 250 mm dia |
| 464 | 300 mm dia |
| 465 | 350 mm dia |
| 466 | 400 mm dia |
| 467 | 450 mm dia |
| 468 | 500 mm dia |
| 469 | 600 mm dia |
| 470 | 700 mm dia |
| 471 | 750 mm dia |
| 472 | 800 mm dia |
| 473 | 900 mm dia |
| 474 | 1000 mm dia |
| 475 | 1100 mm dia |
| 476 | 1200 mm dia |
| 477 | 100 mm dia |
| 478 | 150 mm dia |
| 479 | 200 mm dia |
| 480 | 250 mm dia |
| 481 | 300 mm dia |
| 482 | 350 mm dia |
| 483 | 400 mm dia |
| 484 | 450 mm dia |
| 485 | 500 mm dia |
| 486 | 600 mm dia |
| 487 | 700 mm dia |
| 488 | 750 mm dia |
| 489 | 800 mm dia |
| 490 | 900 mm dia |
| 491 | 1000 mm dia |
| 492 | 1100 mm dia |
| 493 | 1200 mm dia |
| 494 | Providing and Supplying of ISI standard DI specials & fitting with sealing rubber gasket of SBR, complete with cast Iron follower gland & MS nut bolts coated or otherwise protected from rusting and suitable for DI pipescomplete as per IS-9523 class K-12 ( ex factory rates ) inspection charge transportation ,CP extra. M1027 |
| 495 | Socketed |
| 496 | 100 -150 mm dia |
| 497 | 200-300 mm dia |
| 498 | 350-450 mm dia |
| 499 | 500-600 mm dia |
| 500 | 700 mm dia |
| 501 | 800 mm dia |
| 502 | 900 mm dia |
| 503 | 1000 mm dia |
| 504 | 1100 mm dia |
| 505 | 1200 mm dia |
| 506 | Flanged |
| 507 | 100 -150 mm dia |
| 508 | 200-300 mm dia |
| 509 | 350-450 mm dia |
| 510 | 500-600 mm dia |
| 511 | 700 mm dia |
| 512 | 800 mm dia |
| 513 | 900 mm dia |
| 514 | 1000 mm dia |
| 515 | 1100 mm dia |
| 516 | 1200 mm dia |
| 517 | Providing and supplying in standard lengths High Density Polyethylene Pipe (HDPE Pipe) confirming to IS 4984-4984/14151/12786/13488 (Latest Revision with necessary jointing materials like mechanical connector i.e. thread/insert joint/quick release coupler joint/compression fitting joint or flanged joints excluding coupler/specials and taxes). M1028 |
| 518 | HDPE pipe of materials grade PE80-PN06 (dia in mm) |
| 519 | 25 mm dia |
| 520 | 32 mm dia |
| 521 | 40 mm dia |
| 522 | 50 mm dia |
| 523 | 63 mm dia |
| 524 | 75 mm dia |
| 525 | 90 mm dia |
| 526 | 110 mm dia |
| 527 | 125 mm dia |
| 528 | 140 mm dia |
| 529 | 160 mm dia |
| 530 | 180 mm dia |
| 531 | 200 mm dia |
| 532 | 225 mm dia |
| 533 | 250 mm dia |
| 534 | 280 mm dia |
| 535 | 315 mm dia |
| 536 | 355 mm dia |
| 537 | 400 mm dia |
| 538 | 450 mm dia |
| 539 | 500 mm dia |
| 540 | HDPE pipe of materials grade PE80-PN10 (dia in mm) |
| 541 | 25 mm dia |
| 542 | 32 mm dia |
| 543 | 40 mm dia |
| 544 | 50 mm dia |
| 545 | 63 mm dia |
| 546 | 75 mm dia |
| 547 | 90 mm dia |
| 548 | 110 mm dia |
| 549 | 125 mm dia |
| 550 | 140 mm dia |
| 551 | 160 mm dia |
| 552 | 180 mm dia |
| 553 | 200 mm dia |
| 554 | 225 mm dia |
| 555 | 250 mm dia |
| 556 | 280 mm dia |
| 557 | 315 mm dia |
| 558 | 355 mm dia |
| 559 | 400 mm dia |
| 560 | 450 mm dia |
| 561 | 500 mm dia |
| 562 | Providing and supplying in standard lengths High Density Polyethylene Pipe (HDPE Pipe) 25mm to 500mm dia confirming to IS 4984-4984/14151/12786/13488 (Latest Revision with necessary jointing materials like mechanical connector i.e. thread/insert joint/quick release coupler joint/compression fitting joint or flanged joints excluding coupler/specials and taxes. M1029 |
| 563 | HDPE pipe of materials grade PE100-PN06 (dia in mm) |
| 564 | 25 mm dia |
| 565 | 32 mm dia |
| 566 | 40 mm dia |
| 567 | 50 mm dia |
| 568 | 63 mm dia |
| 569 | 75 mm dia |
| 570 | 90 mm dia |
| 571 | 110 mm dia |
| 572 | 125 mm dia |
| 573 | 140 mm dia |
| 574 | 160 mm dia |
| 575 | 180 mm dia |
| 576 | 200 mm dia |
| 577 | 225 mm dia |
| 578 | 250 mm dia |
| 579 | 280 mm dia |
| 580 | 315 mm dia |
| 581 | 355 mm dia |
| 582 | 400 mm dia |
| 583 | 450 mm dia |
| 584 | 500 mm dia |
| 585 | HDPE pipe of materials grade PE100-PN10 (dia in mm) |
| 586 | 25 mm dia |
| 587 | 32 mm dia |
| 588 | 40 mm dia |
| 589 | 50 mm dia |
| 590 | 63 mm dia |
| 591 | 75 mm dia |
| 592 | 90 mm dia |
| 593 | 110 mm dia |
| 594 | 125 mm dia |
| 595 | 140 mm dia |
| 596 | 160 mm dia |
| 597 | 180 mm dia |
| 598 | 200 mm dia |
| 599 | 225 mm dia |
| 600 | 250 mm dia |
| 601 | 280 mm dia |
| 602 | 315 mm dia |
| 603 | 355 mm dia |
| 604 | 400 mm dia |
| 605 | 450 mm dia |
| 606 | 500 mm dia |
| 607 | RCC ESR M1030 |
| 608 | Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging Consisting of columns, internal and External bracings spaced vertically not More than 4.5 metres centre to centre for ESR having capacity upto 500 cum and Not more than 6m c/c for ESR having Capacity above 500 Cum including Excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all Columns and Bracings including refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder out side, Stainless Steel lader in contenor, C.I. manhole frame and covers, water level indicators,lightening conductor, G.I. pipe railing around walk way and top slab, providing stair case from ground level to roof level, M.S. Grill gate of 2M height with locking arrangement of approved design, B.B. Masonry chambers for all valves, ventilating shafts, providing and applying three coats of Acrylie emulsion with silicon edditives paint to the structure incluing roof slab, epoxy painting to internal surface and anti-termite treatment for under ground part soft he structure and giving satisfactory water tightness test as per I.S. code. The job to include painting then ame of the scheme and other details on the reservoir as per the directions of Engineer In - Charge. |
| 609 | Rates for RCC ESRs |
| 610 | Upto 25,000 litres |
| 611 | Cost of 25,000 litres capacity |
| 612 | Add for capacity above 25,000 upto 50,000 litres |
| 613 | Cost of 50,000 litres capacity |
| 614 | Add for capacity above 50,000 upto 75,000 litres |
| 615 | Cost of 75,000 litres capacity |
| 616 | Add for capacity above 75,000 upto 1,00,000 litres |
| 617 | Cost of 1,00,000 litres capacity |
| 618 | Add for capacity above 1,00,000 upto 1,50,000 litres |
| 619 | Cost of 1,50,000 litres capacity |
| 620 | Add for capacity above 1,50,000 upto 2,00,000 litres |
| 621 | Cost of 2,00,000 litres capacity |
| 622 | Add for capacity above 2,00,000 upto 2,50,000 litres |
| 623 | Cost of 2,50,000 litres capacity |
| 624 | Add for capacity above 2,50,000 upto 3,00,000 litres |
| 625 | Cost of 3,00,000 litres capacity |
| 626 | Add for capacity above 3,00,000 upto 4,00,000 litres |
| 627 | Cost of 4,00,000 litres capacity |
| 628 | Add for capacity above 4,00,000 upto 5,00,000 litres |
| 629 | Cost of 5,00,000 litres capacity |
| 630 | Add for capacity above 5,00,000 upto 7,50,000 litres |
| 631 | Cost of 7,50,000 litres capacity |
| 632 | Add for capacity above 7,50,000 upto 10,00,000 litres |
| 633 | Cost of 10,00,000 litres capacity |
| 634 | Add for capacity above 10,00,000 upto 15,00,000 litres |
| 635 | Cost of 15,00,000 litres capacity |
| 636 | Add for capacity above 15,00,000 upto 20,00,000 litres |
| 637 | Cost of 20,00,000 litres capacity |
| 638 | RCC GSR AND SUMP M1031 |
| 639 | Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion. to inside face of the container,including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye-pass arrangement consisting of C.I./ M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. |
| 640 | Anti โtermite treatment shall be given for under ground portion of the structure. |
| 641 | Notes |
| 642 | The design shall be in accordance with various relevant I.S. specification (I.S.456/2000,I.S.875-1987,I.S.3370-1965 or revised.) |
| 643 | Only M.S. bars grade I conforming to I.S. 432 part-I or high yield strength deformed bars conforming to I.S. 1786 or I.S.1139 shall be used.Grade- II M.S. bars shall not be used. |
| 644 | Entire structure shall be in M-300 only. |
| 645 | The scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included. |
| 646 | The G.S.R. / Sump above 15 lakh litres capacity shall be in two compartment. |
| 647 | The Job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by Engineer-in-charge. If up lifts considered in design, then these rates shall be increased by 7.5%. |
| 648 | G.S.R. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. Sump well includes cost of suction pit required at bottom. |
| 649 | For pipe diameters upto 300mm only CIpipes and CI specials shall be used. For pipe diameters above 300mm, M.S. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside. |
| 650 | Cost of pump house is not included in these rates. |
| 651 | Above rates are applicable for Seismic Zones 2, 3 and 4. |
| 652 | 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of G.S.R. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete. |
| 653 | 10% shall be added for sump if over head pump house is proposed. |
| 654 | Note: Conditions from Sr.No.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of R.C.C .GSRs and sumps. |
| 655 | Rates for RCC GSRs and Sumps |
| 656 | Upto 25,000 litres |
| 657 | Cost of 25,000 litres capacity |
| 658 | Add for capacity above 25,000 upto 50,000 litres |
| 659 | Cost of 50,000 litres capacity |
| 660 | Add for capacity above 50,000 upto 75,000 litres |
| 661 | Cost of 75,000 litres capacity |
| 662 | Add for capacity above 75,000 upto 1,00,000 litres |
| 663 | Cost of 1,00,000 litres capacity |
| 664 | Add for capacity above 1,00,000 upto 1,50,000 litres |
| 665 | Cost of 1,50,000 litres capacity |
| 666 | Add for capacity above 1,50,000 upto 2,00,000 litres |
| 667 | Cost of 2,00,000 litres capacity |
| 668 | Add for capacity above 2,00,000 upto 3,00,000 litres |
| 669 | Cost of 3,00,000 litres capacity |
| 670 | Add for capacity above 3,00,000 upto 5,00,000 litres |
| 671 | Cost of 5,00,000 litres capacity |
| 672 | Add for capacity above 5,00,000 upto 10,00,000 litres |
| 673 | Cost of 10,00,000 litres capacity |
| 674 | Addforcapacityabove10,00,000upto15,00,000 litres |
| 675 | Cost of 15,00,000 litres capacity |
| 676 | Add for capacity above 15,00,000 litres |
| 677 | Note: 10% shall be added over the cost of GSR for sump where over head pump house is proposed. |
| 678 | Unconventional Water Treatment Plant M1032 |
| 679 | Designing (aesthetically), providing and constructing high rate Unconventional Water Treatment Plant i.e. Simplified Water Treatment Plant consisting of Civil works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing anti-termite treatment to entire structure below ground level, ceramic tiles for floring, Acrylic emulsion with silicon additives paint from outside stainless steel railing, mechanical and electrical components of various sub-works as given below : including necessary hydraulic testing, structural testing and trial for 3 months, etc. complete as directed by Engineer-in-charge (turn-key job) works. |
| 680 | Aeration fountain |
| 681 | Inlet arrangements |
| 682 | Mixing channel with ventury flume and flow measuring arrangement |
| 683 | Inlet channel |
| 684 | Flocculator- Conforming to I.S. 7208-1974 (Type-C) with detention period of 30 minutes |
| 685 | Tube settlers-Designing, fabricating and constructing Tube Settlers with square or any other shaped tube like Circular, Cheveron, Hexagonal etc .having proven performance |
| 686 | Rapid sand gravity filters - All valve shall be glandless. |
| 687 | Filter house |
| 688 | Chemical house |
| 689 | Alum tanks- 2Nos. with mixing, carrying and dosing arrangements with piping. |
| 690 | 100 kg chlorine cylender for capacity upto 5MLD and Chlorine tonner for capacity above 5 MLD. |
| 691 | TCL solution tank with mixing, carrying and dosing arrangement with piping. |
| 692 | Bypass arrangement |
| 693 | External and internal electrification |
| 694 | Laboratory equipments |
| 695 | Wash water tanks of capacity equal to12 minutes to wash specified number of filter beds at time at 600 lit / m2/m under head of 12m at under drain. |
| 696 | Wash water pumps with 100% standby |
| 697 | Air blowers capable of delivering 600 LMP per square metre of free air of filter area at 0.4 Kg / sqcm at the under drains (100 % standby). Air blowers shall be adopted for WTP having capacity more than 3 MLD only. Below 3 MLD capacity, Air blowers shall not be adopted. |
| 698 | Pure water sump of capacity equal to 1 hour pumping capacity. |
| 699 | Pure water pump house over the sump / by the side of sump. |
| 700 | Drainage arrangements |
| 701 | Alum store |
| 702 | Sanitary block with necessary water supply and drainage arrangements and internal WBM roads. |
| 703 | These rates are applicable for seismic zones 2, 3 and 4. |
| 704 | Rates given below are inclusive of uplift pressure if any and dewatering during the entire work. |
| 705 | All RCC structures shall be constructed in M-250. Structures in contact with water shall be in M-300. |
| 706 | Unconventional Treatment Plants less than 1 MLD capacity shall not be constructed. |
| 707 | All the Structural Steel Works / Fabrications are to be provided with application of Hot Dip Zinc coating according to specification as per IS 4759:1996 (Reafirmed 2006). |
| 708 | Note: Conditions from Sr. No. 1 to 28 shall form a part and parcel of the tender and must be included in draft tender papers for the work of unconventional treatment plants. |
| 709 | Unconventional Water Treatment Plant |
| 710 | Fixed cost for 1 MLD |
| 711 | Add for capacity above 1 MLD upto 2 MLD |
| 712 | Cost of 2 MLD treatment plant |
| 713 | Add for capacity above 2 MLD upto 3 MLD |
| 714 | Cost of 3 MLD treatment plant |
| 715 | Conventional Water Treatment Plant M1033 |
| 716 | Designing (aesthetically), providing constructing and commissioning Conventional Water Treatment Plant consisting of all Civil, Mechanical and Electrical works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing antitermite treatment to entire structure below ground level, mechanical and electrical components of various sub-works as given below, including necessary hydraulic testing, structural testing, equipment testing and trial run for a period of 3 months, etc. complete as directed by Engineer-in-charge (turn-key job). |
| 717 | Aeration Fountain- Plan are a not less than 0.625 square metre per MLD |
| 718 | Ventury Flume - With necessary devices, consisting of simple mechanical indicator. (Pedestal type gauge) |
| 719 | Flash Mixer-Rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec -1, vane mixer type conforming to I.S. 7090 of 1985. |
| 720 | Flocculator โ Conforming to I.S.7208-1974 (Type-C) with detention period of 30 minutes. |
| 721 | Clarifier - Horizontal flow circular tank, detention period 2-5 hours, overflow rate 30 cubic metre per square metre per day (to be specified), Weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to I.S. No. 10313-1982. |
| 722 | Rapid Sand Filter sand Filter House-Filter designed for filteration rate of 5,000 litres per square metre per hour, minimum 2 beds for plant upto 10 MLD, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width. |
| 723 | FilterSand-Effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75M, free board 50cm, gravel 0.45M in depth, sand and gravel conforming to I.S. 8491 (i)-77, back wash by air wash, stand ard appurtenances (to be specified), rate of flow controller, filter gauge, sand expansion gauge, etc. |
| 724 | Wash Water Tank-Capacity to be specified and suitable to supply water to wash 2 filter units at a time where the units are 4 or more. |
| 725 | Wash Water Pumps- Capacity to fill water tank in 1 hour with 100% standby. |
| 726 | Air Blowers-Capable of delivering 600 LMP per square metre of free air, of filter area at 0.4kg / sqcm at the under drains (100% standby). |
| 727 | Chemical House in Two Storeys |
| 728 | Ground floor to accommodate 7 days' alum requirement and sundry storage. |
| 729 | First floor to accommodate alum and lime tanks. etc. |
| 730 | Solution tanks-Minimum 3 tanks (one for preparation, second for dosing and third as standby), each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30M, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device (constant head device, strength of solution upto 10% only) conforming to I.S. 9222 Part-I 1979. |
| 731 | Pure Water Sump and Sump House. |
| 732 | Capacity of sump โ One hour of designed flow. |
| 733 | Pump House- Pump house of required size over the sump or by the side. |
| 734 | Store House-Suitable for alum storage of three months' requirement in monsoon with 10% extra capacity for other sundry articles. |
| 735 | Vacuum feed type Chlorinators- Make tobe approved by MJP. |
| 736 | Conforming to I.S. 10533 - A Part-II 1983 |
| 737 | Rate for withdrawal |
| 738 | Temperature Kg. of Chlorine discharge Degree 'C' per day (Cylinders) |
| 739 | 45 67 Tonnes |
| 740 | 10 6.35 9.50 110 |
| 741 | 15 10.75 16.10 130 |
| 742 | 20 14.50 21.24 254 |
| 743 | 27&Above 18.70 28.12 315 |
| 744 | Chlorinator equipment and container room to conform to I.S. 10553 Part-I 1983. |
| 745 | 100% standby shall be provided. |
| 746 | By pass arrangements - C.I. or M.S. pipes. |
| 747 | Disposal of waste from WTP: Safe disposal arrangement to near by Nala including cost of pipe |
| 748 | For WTP of Capacity 30 MLD and more additional arrangement for backwash water recycle shall be provided, including sump, pupming machinary,rising main etc complete |
| 749 | Drainage arrangements โ RCC pipes up to plot boundary. |
| 750 | Electrical installation โ Both internal and external including entire plant area. |
| 751 | Laboratory equipment โAs per requirement (to be specified during tendering). |
| 752 | Sanitary blocks โ Carpet area -15 square metre minimum upto 25 Mld and 25 square metre above 25 Mld. |
| 753 | Administrative block and internal road-To accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and WBM road to connect all units from main gate of plot. |
| 754 | Rates given below are inclusive of up lift pressure if any and dewatering during entire work. |
| 755 | All pipes condutes channels with20%overloading |
| 756 | These rates are applicable for seismic zones 2, 3 and 4. |
| 757 | All RCC structures shall be constructed in M-300. |
| 758 | Note: Conditions from Sr. No. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants (proposed). |
| 759 | Conventional Water Treatment Plant |
| 760 | Above 3 MLD to Upto 5 MLD |
| 761 | Cost of 5 MLD treatment plant |
| 762 | Add for capacity above 5MLD upto 10 MLD |
| 763 | Cost of 10 MLD treatment plant |
| 764 | Add for capacity above 10 MLD upto 20 MLD |
| 765 | Cost of 20 MLD treatment plant |
| 766 | Add for capacity above 20 MLD upto 50 MLD |
| 767 | Cost of 50 MLD treatment plant |
| 768 | Add for capacity above 50 MLD upto 100 MLD |
| 769 | Cost of 100 MLD treatment plant |
| 770 | Add for capacity above 100 MLD |
| 771 | GPT/HYGPT : Drilling by Rotary drill machine of size 300mm & 400mm dia with T.C. drill bit for tubewells in all kinds of soil including moorum, hard soil, soil mixed with pebbles, shingles, compacted soil, clay, soft and decomposed rock etc, up to 60 meters depth including reaming to facilitate smooth lowering of casing pipe etc. as per specification and direction of E/I (Basic rates) M1034 |
| 772 | 300 mm dia for GPT |
| 773 | 400 mm dia for HYGPT |
| 774 | HYDT : Cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH Rig machine, all complete including supplying all materials, tools, drilling rig, Air Compressor and equipments, as well as fuel, lubricants and cost of transportation of Rig machine and other vehicles up to the site (Basic rates) M1035 |
| 775 | From 0-50 meter |
| 776 | From 51-125 meter |
| 777 | MS Pipe M1036 |
| 778 | Supplying all tools, tackles & lowering of 200 mm dia MS ERW casing pipe of 6mm wall thickness including welding charges, cost of pipe etc . all complete job (Basic rates) |
| 779 | Supplying all materia;ls, labours, tools & equipments for fitting & fixing 200mm dia MS cap over casing pipe complete job (Basic rates) |
| 780 | DT : Basic rates for 125/115 mm dia Drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig Machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and dirrection of Engineer Incharge (Basic rates) M1037 |
| 781 | Drillig upto 30 mtr Depth below G. L. in Rural Area |
| 782 | Drilling beyond 31 mtr upto 60 mtr below G. L. in Rural Area |
| 783 | Trenchless M1038 |
| 784 | Installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation ,shoring / strutting etc manual shielded excation ,lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering -in - charge all complete exept the cost of the pipe average cover of 1.5 depth below GI ( upto 100 meter installation length ) |
| 785 | from 900 mm to 1000 mm dia |
| 786 | In Soft soil |
| 787 | In Hard soil |
| 788 | In sandy Soil |
| 789 | In Stone Soil |
| 790 | from 1000 mm to 1200 mm dia |
| 791 | In Soft soil |
| 792 | In Hard soil |
| 793 | In sandy Soil |
| 794 | In Stone Soil |
| 795 | Above 1200 mm to 1500 mm dia |
| 796 | In Soft soil |
| 797 | In Hard soil |
| 798 | In sandy Soil |
| 799 | In Stone Soil |
| 800 | Installation of product pipe by Auger Boring method including making of entry and exit pits all related civil works like excavation ,shoring /strutting etc shielded excavation ,through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering -in - charge all complete exept the cost of the pipe average cover of 1.5 depth below GI ( upto 100 meter installation length ) |
| 801 | upto 300 mm dia |
| 802 | In Soft soil |
| 803 | In Hard soil |
| 804 | In sandy Soil |
| 805 | In Stone Soil |
| 806 | Above300 mm to 450 mm dia |
| 807 | In Soft soil |
| 808 | In Hard soil |
| 809 | In sandy Soil |
| 810 | In Stone Soil |
| 811 | Above 450 mm to 600 mm dia |
| 812 | In Soft soil |
| 813 | In Hard soil |
| 814 | In sandy Soil |
| 815 | In Stone Soil |
| 816 | Above 600 mm to 900 mm dia |
| 817 | In Soft soil |
| 818 | In Hard soil |
| 819 | In sandy Soil |
| 820 | In Stone Soil |
| 821 | Installation of product pipe by Guided Auger Boring method including making of entry and exit pits all related civil works like excavation ,shoring /strutting etc shielded excavation ,through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering -in - charge all complete exept the cost of the pipe average cover of 1.5 depth below GI ( upto 100 meter installation length ) |
| 822 | upto 300 mm dia |
| 823 | In Soft soil |
| 824 | In Hard soil |
| 825 | In sandy Soil |
| 826 | In Stone Soil |
| 827 | Above300 mm to 450 mm dia |
| 828 | In Soft soil |
| 829 | In Hard soil |
| 830 | In sandy Soil |
| 831 | In Stone Soil |
| 832 | Above 450 mm to 600 mm dia |
| 833 | In Soft soil |
| 834 | In Hard soil |
| 835 | In sandy Soil |
| 836 | In Stone Soil |
| 837 | Above 600 mm to 900 mm dia |
| 838 | In Soft soil |
| 839 | In Hard soil |
| 840 | In sandy Soil |
| 841 | In Stone Soil |
| 842 | Providing and Supplying ISI Mark CI/ D/F reflux valves ( Non return Valves ) of following dia inspection charges unloading from railway wagon ,loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per IS 5312 Part I (1984) M1039 |
| 843 | Without byepass arrangement - PN-1 |
| 844 | 50 MM |
| 845 | 65 MM |
| 846 | 80 MM |
| 847 | 100 MM |
| 848 | 125 MM |
| 849 | 150 MM |
| 850 | 200 MM |
| 851 | 250 MM |
| 852 | 300 MM |
| 853 | 350 MM |
| 854 | 400 MM |
| 855 | 450 MM |
| 856 | 500 MM |
| 857 | 600 MM |
| 858 | 700 MM |
| 859 | 750 MM |
| 860 | 800 MM |
| 861 | 900 MM |
| 862 | 1000 MM |
| 863 | 1100 MM |
| 864 | 1200 MM |
| 865 | With byepass arrangement - PN-1 |
| 866 | 50 MM |
| 867 | 65 MM |
| 868 | 80 MM |
| 869 | 100 MM |
| 870 | 125 MM |
| 871 | 150 MM |
| 872 | 200 MM |
| 873 | 250 MM |
| 874 | 300 MM |
| 875 | 350 MM |
| 876 | 400 MM |
| 877 | 450 MM |
| 878 | 500 MM |
| 879 | 600 MM |
| 880 | 700 MM |
| 881 | 750 MM |
| 882 | 800 MM |
| 883 | 900 MM |
| 884 | 1000 MM |
| 885 | 1100 MM |
| 886 | 1200 MM |
| 887 | Without byepass arrangement - PN-1.6 |
| 888 | 50 MM |
| 889 | 65 MM |
| 890 | 80 MM |
| 891 | 100 MM |
| 892 | 125 MM |
| 893 | 150 MM |
| 894 | 200 MM |
| 895 | 250 MM |
| 896 | 300 MM |
| 897 | 350 MM |
| 898 | 400 MM |
| 899 | 450 MM |
| 900 | 500 MM |
| 901 | 600 MM |
| 902 | With byepass arrangement - PN-1.6 |
| 903 | 50 MM |
| 904 | 65 MM |
| 905 | 80 MM |
| 906 | 100 MM |
| 907 | 125 MM |
| 908 | 150 MM |
| 909 | 200 MM |
| 910 | 250 MM |
| 911 | 300 MM |
| 912 | 350 MM |
| 913 | 400 MM |
| 914 | 450 MM |
| 915 | 500 MM |
| 916 | 600 MM |
| 917 | Providing double flange sluice valve ( Size 50 mm to 1200 mm ) confirming for IS - 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . |
| 918 | With byepass arrangement - PN-1 |
| 919 | 50 MM |
| 920 | 65 MM |
| 921 | 80 MM |
| 922 | 100 MM |
| 923 | 125 MM |
| 924 | 150 MM |
| 925 | 200 MM |
| 926 | 250 MM |
| 927 | 300 MM |
| 928 | 350 MM |
| 929 | 400 MM |
| 930 | 450 MM |
| 931 | 500 MM |
| 932 | 600 MM |
| 933 | 700MM |
| 934 | 750 MM |
| 935 | 800 MM |
| 936 | 900 MM |
| 937 | 1000 MM |
| 938 | 1100 MM |
| 939 | 1200MM |
| 940 | Without byepass arrangement - PN-1 |
| 941 | 50 MM |
| 942 | 65 MM |
| 943 | 80 MM |
| 944 | 100 MM |
| 945 | 125 MM |
| 946 | 150 MM |
| 947 | 200 MM |
| 948 | 250 MM |
| 949 | 300 MM |
| 950 | 350 MM |
| 951 | 400 MM |
| 952 | 450 MM |
| 953 | 500 MM |
| 954 | 600 MM |
| 955 | 700MM |
| 956 | 750 MM |
| 957 | 800 MM |
| 958 | 900 MM |
| 959 | 1000 MM |
| 960 | 1100 MM |
| 961 | 1200MM |
| 962 | Providing double flange sluice valve confirming for IS - 2906 / 14846 including worn gear as per test pressure stailess steel spindle , caps transportation etc. all complete FOR Rateincluding all taxes . . |
| 963 | Without byepass arrangement - PN-1.6 |
| 964 | 50 MM |
| 965 | 65 MM |
| 966 | 80 MM |
| 967 | 100 MM |
| 968 | 125 MM |
| 969 | 150 MM |
| 970 | 200 MM |
| 971 | 250 MM |
| 972 | 300 MM |
| 973 | 350 MM |
| 974 | 400 MM |
| 975 | 450 MM |
| 976 | 500 MM |
| 977 | 600 MM |
| 978 | 700MM |
| 979 | 750 MM |
| 980 | 800 MM |
| 981 | 900 MM |
| 982 | 1000 MM |
| 983 | 1100 MM |
| 984 | 1200MM |
| 985 | With byepass arrangement - PN-1.6 |
| 986 | 50 MM |
| 987 | 65 MM |
| 988 | 80 MM |
| 989 | 100 MM |
| 990 | 125 MM |
| 991 | 150 MM |
| 992 | 200 MM |
| 993 | 250 MM |
| 994 | 300 MM |
| 995 | 350 MM |
| 996 | 400 MM |
| 997 | 450 MM |
| 998 | 500 MM |
| 999 | 600 MM |
| 1000 | Design and Supply of V -wire screen laterals suitable for infiltration Galleryas per site condition and detail provided End connection suitable flange excluding taxes and transportation . M1040 |
| 1001 | Dia - 06 inch ( 150 mm ) |
| 1002 | ID - 153 mm OD -167 mm |
| 1003 | Screen thickness - 07 mm |
| 1004 | Slot - 1.00 mm |
| 1005 | MOC - Low Carbon Galvenised steel |
| 1006 | Length - 5 mtr. |
| 1007 | Dia - 08 inch ( 200 mm ) |
| 1008 | ID - 205 mm OD -221mm |
| 1009 | Screen thickness - 08 mm |
| 1010 | Slot - 1.00 mm |
| 1011 | MOC - Low Carbon Galvenised steel |
| 1012 | Length - 5 mtr. |
| 1013 | Dia - 10 inch ( 250 mm ) |
| 1014 | ID - 256 mm OD -276mm |
| 1015 | Screen thickness - 10 mm |
| 1016 | Slot - 1.00 mm |
| 1017 | MOC - Low Carbon Galvenised steel |
| 1018 | Length - 5 mtr. |
| 1019 | Dia - 12 inch ( 300 mm ) |
| 1020 | ID - 306 mm OD -326 mm |
| 1021 | Screen thickness - 10 mm |
| 1022 | Slot - 1.00 mm |
| 1023 | MOC - Low Carbon Galvenised steel |
| 1024 | Length - 5 mtr. |
| 1025 | Dia - 14 inch ( 350 mm ) |
| 1026 | ID - 338 mm OD -363 mm |
| 1027 | Screen thickness - 12.5 mm |
| 1028 | Slot - 1.00 mm |
| 1029 | MOC - Low Carbon Galvenised steel |
| 1030 | Length - 5 mtr. |
| 1031 | Supplying all materials, labours, equipments for lowering 125mm dia blue UPVC casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site (Basic Rate). M1041 |
| 1032 | Supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction E/I (Basic Rate). M1042 |
| 1033 | Supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of E/I (Basic Rate). M1043 |
| 1034 | Supplying labour and equipments including 125mm dia G.I. Cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction E/I (The cap will be the property of department) (Basic Rate). M1044 |
| 1035 | Supplying all materials, labours, equipments for constructing P.C.C. (1:2:4) circular platform around drilled tube well including 12mm thick cement plaster (1:4) with neat cement punning over exposed surface as per UNICEF design, etc. all complete including carriage of materials (Basic Rate). M1045 |
| 1036 | Supplying all materials, labours and equipments for constructing P.C.C. (1:2:4) drain as per UNICEF design etc. all complete including carriage of materials (Basic Rate). M1046 |
| 1037 | Supplying extra Deep well Hand Pump Complete sets with Cylinder Assembly & Connecting Rod (12 Pcs) as per IS : 15500 Part-2/2004 (Basic Rate). M1047 |
| 1038 | Supply of 200mm dia x 3.00m long UPVC casing pipe conferming to IS : 12818 : 2016 (CML No. 5543459) latest revision including carrigae (Basic Rate). M1048 |
| 1039 | Supply of 200mm dia ribbed Screen pipe conferming to IS : 12818 : 2016 (CML No. 5543459) latest revision including carrigae (Basic Rate). M1049 |
| 1040 | Supply of 125mm dia ribbed Screen pipe conferming to IS : 12818 : 2016 (CML No. 5543459) latest revision including carrigae (Basic Rate). M1050 |
| 1041 | Supplying all tools, equipments and labour and lowering 32 mm dia medium quality G.I. pipe in drilled tube well in 3 Mtrs. Length all complete as per dirction E/I including carriage of materials (Basic Rate). M1051 |
| 1042 | Supplying all tools, Labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of E/I including carriage of materials (Basic Rate).M1052 |
| 1043 | Supplying all materials, labours and fixing India mark II Hand Pump with all accessories all complete job as per direction of E/I including carriage of materials (Basic Rate). M1053 |
| 1044 | Design, Supply, Installation testing & Commissioning of packaged water treatment plants (Unconventional type) of different capacity with (20 hours operation) comprising of lamella clarifier, Static Mixture Flocculation Tank (SMET), Multi grade filter (MGF) with best quality filter media, Lime/ coagulant/polymer dosing system hypo chloride dosing system, Raw water feed pump/clear water transfer pump (either or), sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with MCB panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratory facility should be from a reputed manufacturer/ authorized distribution / authorized dealer conforming to relevant IS codes and certified by ISO-9001-2008 & 14001, It also include cost of civil foundation, including clarified water tank internal connecting pipe line from Raw Water inlet to CWR and applying internal epoxy paint on the supply equipment All the prices are exclusive of GST, Allied structure/items which are site specific such as external electrification, approach road, foot Bridge, cofferdam, compound wall, SCADA and automation, CWR pumps etc are to be considered extra. M1054 |
| 1045 | PUMPS M1055 |
| 1046 | Supplying 100 mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/ noryl impeller. Motor suitable for working on 415V+10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/ fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/ double run shall be provided with each pump. |
| 1047 | Submersible Pump set 100 mm dia (with Polypropylene/ Noryl Impeller) up to 20 stages |
| 1048 | 1 H.P. |
| 1049 | 1.5 HP |
| 1050 | 2.5 HP |
| 1051 | 3.0 HP |
| 1052 | 4.0 HP |
| 1053 | 5.0 HP |
| 1054 | Supply rate should be increased by Rs 200/- per stage for pump with more than 20 stages |
| 1055 | Submersible Pump 150 mm dia (with Bronze impeller) up to 8 stages |
| 1056 | 1.5 HP |
| 1057 | 2.0 HP |
| 1058 | 3.0 HP |
| 1059 | 4.0 HP |
| 1060 | 5.0 HP |
| 1061 | 6.0 HP |
| 1062 | 7.5 HP |
| 1063 | Supply rate should be increased by Rs 600/- per stage for pump with more than 8 stages |
| 1064 | Submersible Pump 150 mm dia (with Bronze Impeller) up to 12 stages |
| 1065 | 8.0 HP |
| 1066 | 9.0 HP |
| 1067 | 10.0 HP |
| 1068 | 11.0 HP |
| 1069 | 12.5 HP |
| 1070 | 15.0 HP |
| 1071 | Supply rate should be increased by Rs 600/- per stage for pump with more than 12 stages |
| 1072 | Submersible Pump 150 mm dia (with Bronze Impeller) up to 20 stages |
| 1073 | 17.5 HP |
| 1074 | 20.0 HP |
| 1075 | 25 HP |
| 1076 | 1) Supply rate should be increased by Rs 600/- per stage for pump with more than 20 stages for Bore well only. |
| 1077 | For other use 200 mm dia pump shall be preferred over 150 mm dia with more than 20 stage pump. |
| 1078 | 2) For 150 mm dia energy efficient pumps add as below |
| 1079 | a. up to 8 stages :- 3% on supply rate |
| 1080 | b. up to 12 stages :- 4% on supply rate |
| 1081 | c. up to 15 stages :- 5% on supply rate |
| 1082 | PRESSURE GAUGE M1056 |
| 1083 | Providing fabricating, testing and commisioning pressure vessel fabricating in M.S plate on providing foundation including epoxy paint |
| 1084 | Pressure gauge (100 mm dia) |
| 1085 | Pressure gauge (150 mm dia) |
| 1086 | Vacuum / Combination gauge |
| 1087 | Supplying Vacuum Gauge/ Combination gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. pipe. |
| 1088 | Vacuum / Combination gauge โ 100 mm dia |
| 1089 | Vacuum / Combination gauge โ 150 mm dia |
| 1090 | Lifting Equipment M1057 |
| 1091 | Chain pulley Block |
| 1092 | Supplying triple spur gear type chain pulley block suitable for capacity as below with 3 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark. |
| 1093 | 1 Tonne Capacity |
| 1094 | 2 Tonne Capacity |
| 1095 | 3 Tonne Capacity |
| 1096 | Hand operated Circular or Rectangular Travelling Crane (Single Girder) |
| 1097 | Supplying Single Girder Hand Operated Circular/ Rectangular Travelling Crane with 6 m lift complete with chain pulley block ISI marked and travelling trolley both tested for 50% overload including arrangement for longitudinal travel / circular travel and cross travel with wheel, hand chain, etc complete. |
| 1098 | 3 Tonne Capacity |
| 1099 | Up to 5 m span |
| 1100 | Above 5 m up to 6 m span |
| 1101 | Above 6 m up to 8 m span |
| 1102 | 5 Tonne Capacity |
| 1103 | Up to 5 m span |
| 1104 | Above 5 m up to 6 m span |
| 1105 | Above 6 m up to 8 m span |
| 1106 | Above 8 m up to 10 m span |
| 1107 | Electric Operated Circular or Rectangular Travelling Crane (Single Girder) |
| 1108 | Supplying single girder Electrically Operated Rectangular Over head Travelling Crane with 6 m lift complete with wire rope hoist, class II duty, all three motions electrically operated by suitable rating motor IP 54, control panel and down pendant control block. |
| 1109 | 5 Tonne Capacity |
| 1110 | Above 6 m up to 8 m span |
| 1111 | Above 8 m up to 10 m span |
| 1112 | 7.5 Tonne Capacity |
| 1113 | Above 6 m upto 8 m span |
| 1114 | Above 8 m up to 10 m span |
| 1115 | 10 Tonne Capacity |
| 1116 | Above 6 m up to 8 m span |
| 1117 | Above 8 m up to 10 m span |
| 1118 | Square Bar / Rail |
| 1119 | Providing, erecting and fixing square bar of EN 8 as rail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and โJโ bolts. |
| 1120 | 50 X 50 mm (EN 8) |
| 1121 | 40 X 40 mm (EN 8) |
| 1122 | Lightening Arrester, AB Switch, Insulators M1058 |
| 1123 | Lightening Arrestor |
| 1124 | Supplying, erecting approved make thyrite type Lightening Arrestor suitable for H.T. supply with necessary ancillary material complete on provided cross arm and connected to overhead line. |
| 1125 | Suitable for 11 kV Supply, Distribution class |
| 1126 | Suitable for 22 kV Supply, Distribution class |
| 1127 | Suitable for 33 kV Supply, Station class |
| 1128 | Disc Insulator |
| 1129 | Supplying, erecting porcelain Disc Type Insulators with hardware fittings suitable for H.T. overhead line complete erected with nuts and bolts on provided cross arm |
| 1130 | Suitable for 11KV line |
| 1131 | Suitable for 33KV line |
| 1132 | Pin Insulator |
| 1133 | Supplying, erecting porcelain Pin Type Insulators with hardware fittings suitable for H.T. overhead line complete erected with nuts and bolts on provided cross arm |
| 1134 | Suitable for 11KV line |
| 1135 | Suitable for 33KV line |
| 1136 | Air break switch without Earth switch |
| 1137 | Supplying, erecting approved make H.T. outdoor type gang operated air break triple pole switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground with necessary clamps |
| 1138 | Suitable for 11KV line |
| 1139 | Rocking / Tilting type |
| 1140 | Rotating type |
| 1141 | Suitable for 33KV line |
| 1142 | Rocking / Tilting type |
| 1143 | Rotating type |
| 1144 | Air break switch with Earth switch |
| 1145 | Supplying, erecting approved make H.T. outdoor type gang operated air break triple pole switch with earth switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground with necessary clamps |
| 1146 | Suitable for 11KV line |
| 1147 | Rotating type |
| 1148 | Suitable for 33KV line |
| 1149 | Rotating type |
| 1150 | Drop out Fuse (channel mounted) |
| 1151 | Supplying, erecting approved make out door type Drop out fuse channel type with insulator complete with fuse holders fuse barrel with metal fittings, fuse element, with working current up to 50 Amp, capacity complete erected on provided cross arm, each set comprising 3 units |
| 1152 | Suitable for 11 KV line |
| 1153 | Suitable for 33 KV line |
| 1154 | Horn gap fuse (channel mounted) |
| 1155 | Supplying, erecting approved make out door type Horn gap type fuse with insulator, fuse element, with working current up to 50 Amp, capacity complete erected on provided cross arm, each set comprising 3 units |
| 1156 | Suitable for 11 KV line |
| 1157 | Suitable for 33 KV line |
| 1158 | TRANSFORMER M1059 |
| 1159 | Power Transformer (with off load Tap changer) Any ISI Mark |
| 1160 | Supplying outdoor type copper wound transformer continuously rated for 3Ph, 50 Hz, at full load and temp. rise not exceeding 450 C by thermometer in oil and 500 C by the resistance in winding after continuous run at full load rating, the transformer should have oil immersed winding having vector group DY11, HT side connected in delta and LT side connected in star with neutral brought out connected to provide separate earthing. The Transformer shall have power terminal arrangement, bushing/ cable end box on HT side and cable end box on LT side. 2 Nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The transformer should have following standard fittings. Transformer shall be latest manufacturing standards as per amended IS specifications and the load & No load losses shall be limited to the values given below or as per IS or Norms issued by SEB which ever are lower- |
| 1161 | 1. Oil conservator with filling hole with cap and plain oil level gauge. |
| 1162 | 2. Silica gel dehydrating breather charged with silica gel. |
| 1163 | 3. Oil drain valve |
| 1164 | 4. Oil filter valve |
| 1165 | 5. Lifting eyes/ hooks |
| 1166 | 6. Two earthing terminals |
| 1167 | 7. Diagram and rating plate |
| 1168 | 8. Air vent |
| 1169 | 9. Explosion vent |
| 1170 | 10. 100mm dia thermo meter with thermometer pocket |
| 1171 | 11. Four bi directional plain roller. |
| 1172 | Power Transformer 11000/433 volts With off load Tap Changer โ 12.5% to +2.5% in steps of 2.5% as per BIS Level-2. |
| 1173 | 63 KVA ( No load loss 180w and load loss 1235w) |
| 1174 | 100 KVA (No load loss 260w and load loss 1760w) |
| 1175 | 160KVA (No load loss 260w and load loss 1760w) |
| 1176 | 200KVA(No load loss 500w and load loss3000w) |
| 1177 | 250KVAA(No load loss 550w and load loss3600w) |
| 1178 | 315KVA (No load loss 580w and load loss 4200w) |
| 1179 | 400 KVA (No load loss 715w and load loss 5000w) |
| 1180 | 500 KVA (No load loss 850w and load loss 5800w) |
| 1181 | 630 KVA (No load loss 1000w and load loss 7000w) |
| 1182 | 750 KVA (No load loss 1500w and load loss 8000w) |
| 1183 | Power Transformer (with on load Tap changer) |
| 1184 | Supplying outdoor type copper wound transformer continuously rated for 3Ph, 50 Hz, at full load and temp. rise not exceeding 450 C by thermometer in oil and 500 C by the resistance in winding after continuous run at full load rating, the transformer should have oil immersed winding having vector group DY11, HT side connected in delta and LT side connected in star with neutral brought out connected to provide separate earthing. The Transformer shall have power terminal arrangement, bushing/ cable end box on HT side and cable end box on LT side. 2Nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. The transformer should have following standard fittings. The OLTC should be suitable for minimum 50 operations per day. Transformer shall be latest manufacturing standards as per amended IS specifications and the load & No load losses shall be limited to the values given below or as per IS or Norms issued by SEB which ever are lower- |
| 1185 | 1. Oil conservator with filling hole with cap and plain oil level gauge. |
| 1186 | 2. Silica gel dehydrating breather charged with silica gel. |
| 1187 | 3. Oil drain valve |
| 1188 | 4. Oil filter valve |
| 1189 | 5. Lifting eyes/ hooks |
| 1190 | 6. Two earthing terminals |
| 1191 | 7. Diagram and rating plate |
| 1192 | 8. Air vent |
| 1193 | 9. Explosion vent |
| 1194 | 10. 100mm dia thermo meter with thermometer pocket |
| 1195 | 11. Four bi directional plain roller. |
| 1196 | 12. Buchholz relay |
| 1197 | 13. Resistance Temp. detector |
| 1198 | 14. Marshalling box |
| 1199 | 15. Automatic Voltage Regulator (AVR) |
| 1200 | 16. Remote Tap Changing Controller (RTCC) |
| 1201 | Transformer 11000/433 volts With on load Tap Changer โ 15% to +5% in steps of 1.25% with RTCC, AVR and marshalling box and other specification as per BIS Level-2. |
| 1202 | 750 KVA |
| 1203 | 1000 KVA |
| 1204 | 1250 KVA |
| 1205 | 1600 KVA |
| 1206 | 2000 KVA |
| 1207 | Motors M1060 |
| 1208 | Foot Mounted Motors TEFC 1500 RPM |
| 1209 | Supplying Foot Mounted TEFC 1500 RPM, squirrel cage induction motor, conforming to IS 325 having continuous rating suitable for operation at 415 volts +/-10%, 3 Phase, 50 HZ +/-3% with โFโ class insulation temperature rise limited to class โBโ insulation. Motors conform to IS-12615 with efficiency level IE3 and provided with enclosure protection class IP-55. |
| 1210 | 15 KW (20 HP) |
| 1211 | 18.5 KW ( 25 HP) |
| 1212 | 22 KW ( 30 HP) |
| 1213 | 30 KW ( 40 HP) |
| 1214 | 37 KW ( 50 HP) |
| 1215 | 45 KW ( 60 HP) |
| 1216 | 55 KW ( 75 HP) |
| 1217 | 75 KW ( 100 HP) |
| 1218 | 90 KW ( 120 HP) |
| 1219 | 110 KW ( 150 HP) |
| 1220 | 132KW(180HP) |
| 1221 | 160KW( 215 HP) |
| 1222 | 250KW (335 HP) |
| 1223 | Foot Mounted Motor TEFC 1500 RPM |
| 1224 | 0.75 KW(1HP) |
| 1225 | 1.1 KW ( 1.5 HP) |
| 1226 | 1.5 KW ( 2 HP) |
| 1227 | 2.2 KW ( 3 HP) |
| 1228 | 3.7 KW ( 5 HP) |
| 1229 | 5.5 KW ( 7.5 HP) |
| 1230 | 7.5 KW ( 10 HP) |
| 1231 | 9.3 KW ( 12.5 HP) |
| 1232 | 11 KW ( 15 HP) |
| 1233 | Aluminium Cable M1061 |
| 1234 | CABLE |
| 1235 | Aluminium conductor three core, XLPE / PVC insulated & armoured cable . |
| 1236 | Supplying XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner. |
| 1237 | 3 core 2.5 sq mm |
| 1238 | 3 core 4 sq mm |
| 1239 | 3 core 6 sq mm |
| 1240 | 3 core 10 sq mm |
| 1241 | 3 core 16 sq mm |
| 1242 | 3 core 25 sq mm |
| 1243 | 3 core 35 sq mm |
| 1244 | 3 core 50 sq mm |
| 1245 | 3 core 70 sq mm |
| 1246 | 3 core 95 sq mm |
| 1247 | 3 core 120 sq mm |
| 1248 | 3 core 150 sq mm |
| 1249 | 3 core 185 sq mm |
| 1250 | 3 core 240 sq mm |
| 1251 | 3 core 300 sq mm |
| 1252 | 3 core 400 sq mm |
| 1253 | Aluminium conductor 3.5 core, XLPE / PVC insulated & unarmoured cable |
| 1254 | Supplying XLPE / PVC insulated, unarmoured cable 1100 V grade with ISI mark Three and half core, stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner. |
| 1255 | 3.5 core 25 sq mm |
| 1256 | 3.5 core 35 sq mm |
| 1257 | 3.5 core 50 sq mm |
| 1258 | 3.5 core 70 sq mm |
| 1259 | 3.5 core 95 sq mm |
| 1260 | 3.5 core 120 sq mm |
| 1261 | 3.5 core 150 sq mm |
| 1262 | 3.5 core 185 sq mm |
| 1263 | 3.5 core 240 sq mm |
| 1264 | 3.5 core 300 sq mm |
| 1265 | 3.5 core 400 sq mm |
| 1266 | HT Aluminium three core 3.3 KVE cable XLPE insulated |
| 1267 | Supplying HT Aluminium three core cable XLPE insulated ,insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.) cores laidup inner sheath of PVC tape ,galvanised steel flat strip armoured,and overall PVC sheathed cable conforming to IS :7098 /II/85 with latest amendments |
| 1268 | 3 core 35 sq mm |
| 1269 | 3 core 50 sq mm |
| 1270 | 3 core 70 sq mm |
| 1271 | 3 core 95 sq mm |
| 1272 | 3 core 120 sq mm |
| 1273 | 3 core150sq mm |
| 1274 | 3 core 185 sq mm |
| 1275 | 3 core 240sq mm |
| 1276 | 3 core 300 sq mm |
| 1277 | 3 core 400 sq mm |
| 1278 | HT Aluminium three core 6.6 KV(UE)/11KV E cable XLPE insulated |
| 1279 | Supplying HT Aluminium three core cable XLPE insulated ,insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.) cores laidup inner sheath of PVC tape ,galvanised steel flat strip armoured,and overall PVC sheathed cable conforming to IS :7098 /II/85 with latest amendments |
| 1280 | 3 core 35 sq mm |
| 1281 | 3 core 50 sq mm |
| 1282 | 3 core 70 sq mm |
| 1283 | 3 core 95 sq mm |
| 1284 | 3 core 120 sq mm |
| 1285 | 3 core150sq mm |
| 1286 | 3 core 185 sq mm |
| 1287 | 3 core 240sq mm |
| 1288 | 3 core 300 sq mm |
| 1289 | 3 core 400 sq mm |
| 1290 | HT Aluminium three core 11KV(UE) cable XLPE insulated |
| 1291 | Supplying HT Aluminium three core cable XLPE insulated ,insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.) cores laidup inner sheath of PVC tape ,galvanised steel flat strip armoured,and overall PVC sheathed cable conforming to IS :7098 /II/85 with latest amendments |
| 1292 | 3 core 35 sq mm |
| 1293 | 3 core 50 sq mm |
| 1294 | 3 core 70 sq mm |
| 1295 | 3 core 95 sq mm |
| 1296 | 3 core 120 sq mm |
| 1297 | 3 core150sq mm |
| 1298 | 3 core 185 sq mm |
| 1299 | 3 core 240sq mm |
| 1300 | 3 core 300 sq mm |
| 1301 | 3 core 400 sq mm |
| 1302 | Aluminium conductor three core, XLPE / PVC insulated & unarmoured cable . |
| 1303 | Supplying XLPE / PVC insulated, unarmoured cable 1100 V grade with ISI mark Three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner. |
| 1304 | 3 core 4 sq mm |
| 1305 | 3 core 6 sq mm |
| 1306 | 3 core 10 sq mm |
| 1307 | 3 core 16 sq mm |
| 1308 | 3 core 25 sq mm |
| 1309 | 3 core 35 sq mm |
| 1310 | 3 core 50 sq mm |
| 1311 | 3 core 70 sq mm |
| 1312 | 3 core 95 sq mm |
| 1313 | 3 core 120 sq mm |
| 1314 | 3 core 150 sq mm |
| 1315 | 3 core 185 sq mm |
| 1316 | 3 core 240 sq mm |
| 1317 | 3 core 300 sq mm |
| 1318 | 3 core 400 sq mm |
| 1319 | Copper Cable M1062 |
| 1320 | CABLE |
| 1321 | 3 Core PVC insulated, PVC sheathed copper conductor flat submersible cable . |
| 1322 | Supplying , Flat flexible submersible cable with, copper conductor, PVC insulated, and PVC sheathed . |
| 1323 | 3 core 1.5 sq mm |
| 1324 | 3 core 2.5 sq mm |
| 1325 | 3 core 4 sq mm |
| 1326 | 3 core 6 sq mm |
| 1327 | 3 core 10 sq mm |
| 1328 | 3 core 16 sq mm |
| 1329 | 3 core 25 sq mm |
| 1330 | 3 core 35 sq mm |
| 1331 | Copper conductor three core, XLPE / PVC insulated & unarmoured cable . |
| 1332 | Supplying XLPE / PVC insulated, unarmoured cable 1100 V grade with ISI mark Three core, solid / stranded copper conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner. |
| 1333 | 3 core 1.5 sq mm |
| 1334 | 3 core 2.5 sq mm |
| 1335 | 3 core 4 sq mm |
| 1336 | 3 core 6 sq mm |
| 1337 | 3 core 10 sq mm |
| 1338 | 3 core 16 sq mm |
| 1339 | 3 core 25 sq mm |
| 1340 | 3 core 35 sq mm |
| 1341 | 3 core 50 sq mm |
| 1342 | 3 core 70 sq mm |
| 1343 | 3 core 95 sq mm |
| 1344 | Copper conductor 3.5 core, XLPE / PVC insulated & armoured cable . |
| 1345 | Supplying XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner. |
| 1346 | 3.5 core 1.5 sq mm |
| 1347 | 3.5 core 2.5 sq mm |
| 1348 | 3.5 core 4 sq mm |
| 1349 | 3.5 core 6 sq mm |
| 1350 | 3.5 core 10 sq mm |
| 1351 | 3.5 core 16 sq mm |
| 1352 | 3.5 core 25 sq mm |
| 1353 | 3.5 core 35 sq mm |
| 1354 | 3.5 core 50 sq mm |
| 1355 | 3 .5 core 70 sq mm |
| 1356 | 3.5 core 95 sq mm |
| 1357 | 3.5 core 120 sq mm |
| 1358 | 3 .5 core150sq mm |
| 1359 | 3.5 core 185 sq mm |
| 1360 | 3.5 core 240sq mm |
| 1361 | 3.5 core 300 sq mm |
| 1362 | 3.5 core 400 sq mm |
| 1363 | copper conductor 3.5 core XLPE/PVC unarmoured |
| 1364 | Supplying XLPE / PVC insulated, unarmoured cable 1100 V grade with ISI mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner. |
| 1365 | 3.5 core 25 sq mm |
| 1366 | 3.5 core 35 sq mm |
| 1367 | 3.5 core 50 sq mm |
| 1368 | 3.5 core 70 sq mm |
| 1369 | 3.5 core 95 sq mm |
| 1370 | 3.5 core 120 sq mm |
| 1371 | 3.5 core150sq mm |
| 1372 | 3.5 core 185 sq mm |
| 1373 | 3.5 core 240sq mm |
| 1374 | 3.5 core 300 sq mm |
| 1375 | 3.5 core 400 sq mm |
| 1376 | Copper conductor three core, XLPE / PVC insulated & armoured cable . |
| 1377 | Supplying XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Three core, solid / stranded copper conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete in an approved manner. |
| 1378 | 3 core 1.5 sq mm |
| 1379 | 3 core 2.5 sq mm |
| 1380 | 3 core 4 sq mm |
| 1381 | 3 core 6 sq mm |
| 1382 | 3 core 10 sq mm |
| 1383 | 3 core 16 sq mm |
| 1384 | 3 core 25 sq mm |
| 1385 | 3 core 35 sq mm |
| 1386 | 3 core 50 sq mm |
| 1387 | 3 core 70 sq mm |
| 1388 | 3 core 95 sq mm |
| 1389 | 3 core 120 sq mm |
| 1390 | 3 core 150sq mm |
| 1391 | 3core 185 sq mm |
| 1392 | 3 core 240 sq mm |
| 1393 | 3 core 300 sq mm |
| 1394 | 3 core 400 sq mm |
| 1395 | FOOT VALVE M1063 |
| 1396 | Foot valve |
| 1397 | Supplying C.I. foot valve having single leather flap and gunmetal seating. Valve shall be fixed on suction side of pump as per requirement including jointing material and hardware. |
| 1398 | Flanged type |
| 1399 | 50 mm |
| 1400 | 65 mm |
| 1401 | 80 mm |
| 1402 | 100 mm |
| 1403 | 125 mm |
| 1404 | 150 mm |
| 1405 | Air Circuit Breaker M1064 |
| 1406 | ACB breaking capacity 50kA Thermal Magnetic Manual draw Out type 3 pole |
| 1407 | 1000A |
| 1408 | 1250A |
| 1409 | 1600A |
| 1410 | 2000A |
| 1411 | STARTER M1065 |
| 1412 | D.O.L. starter with SS Enclosure with 380/415 Volt coil |
| 1413 | 7.5 H.P. |
| 1414 | 10 H.P. |
| 1415 | Supplying Fully automatic star delta starter to operate induction motor working on 415v,3phase,50 hz with no volt coil, Over load element, ON-OFF push buttons, with necessary materials and connected to supply, etc complete starter with original sheet steel encloser |
| 1416 | F.A.S.D starter |
| 1417 | 10.0 H.P. |
| 1418 | 15 H.P. |
| 1419 | 20 H.P. |
| 1420 | 25 H.P. |
| 1421 | 35 H.P. |
| 1422 | 40 HP |
| 1423 | 50 HP |
| 1424 | 75 H.P. |
| 1425 | 100 H.P. |
| 1426 | 125 H.P. |
| 1427 | 150 H.P. |
| 1428 | 250 H.P. |
| 1429 | Servo Controlled Automatic Voltage Stabilizer M1066 |
| 1430 | Providing, erecting Servo Controlled Automatic Voltage stabiliser suitable for out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer (air/oil cooled) as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user's controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incoming and out going cable should be provided. All three phases shall be independently monitored and corrected. Following protections and indications shall be incorporated๔ Over Voltage / Under Voltage๔ Single Phasing๔ Cut off contactor with electronic output sensing unit |
| 1431 | Servo Controlled Automatic Voltage Stabiliser(Out put 415 +/-1%) Input 150 to 450 Volt |
| 1432 | 20 kVA Air cooled |
| 1433 | 25 kVA Air cooled |
| 1434 | 30 kVA Air cooled |
| 1435 | 40 kVA Air cooled |
| 1436 | 50 kVA Oil cooled |
| 1437 | 60 kVA Oil cooled |
| 1438 | 75 kVA Oil cooled |
| 1439 | 100 kVA Oil cooled |
| 1440 | 125 kVA Oil cooled |
| 1441 | Servo Controlled Automatic Voltage Stabiliser (Out put 415 +/-1%) Input 280 to 460 Volt |
| 1442 | 15 KVA Air cooled |
| 1443 | 20 KVA Air cooled |
| 1444 | 25 KVA Air cooled |
| 1445 | 30 KVA Air cooled |
| 1446 | 40 kVA Air cooled |
| 1447 | 50KVA Air cooled |
| 1448 | 60 KVA Oil cooled |
| 1449 | 75KVA Oil cooled |
| 1450 | 100 KVA Oil cooled |
| 1451 | 125 kVA Oil cooled |
| 1452 | 150 KVA oil cooled |
| 1453 | 200KVA oil cooled |
| 1454 | 250KVA oil cooled |
| 1455 | 300 KVA oil cooled |
| 1456 | 400 KVA oil cooled |
| 1457 | Termination Kit M1067 |
| 1458 | Providing and errecting IN-DOOR type termination kit, for 3.3kV/ 6.6 kV / 11kV/ 22kV/33kV XLPE Screened 3 core cable |
| 1459 | IN-DOOR Termination KIT for 3.3kV(E/UE) / 6.6 kV(E) XLPE 3 core cable |
| 1460 | 25-50 mm2 |
| 1461 | 70-120 mm2 |
| 1462 | 150-185 mm2 |
| 1463 | 240-400 mm2 |
| 1464 | OUT-DOOR Termination KIT for 3.3(E/UE)/6.6 KV(E) XLPE 3 core cable |
| 1465 | 25-50 mm2 |
| 1466 | 70-120 mm2 |
| 1467 | 150-185 mm2 |
| 1468 | 240-400 mm2 |
| 1469 | Straight through Joint for 3.3KV(E/UE)/ 6.6 KV(E) XLPE 3 core cable |
| 1470 | 25-50 mm2 |
| 1471 | 70-120 mm2 |
| 1472 | 150-185 mm2 |
| 1473 | 240-300 mm2 |
| 1474 | IN DOOR Termination KIT for 11KV(E) XLPE Screened 3 core cable |
| 1475 | 25-50 mm2 |
| 1476 | 70-120 mm2 |
| 1477 | 150-185 mm2 |
| 1478 | 240-400 mm2 |
| 1479 | OUT DOOR Termination KIT for 11KV(E) XLPE Screened 3 core cable |
| 1480 | 25-50 mm2 |
| 1481 | 70-120 mm2 |
| 1482 | 150-185 mm2 |
| 1483 | 240-400 mm2 |
| 1484 | Straight through Joint for 11 KV(E) XLPE Screened 3 core cable |
| 1485 | 25-50 mm2 |
| 1486 | 70-120 mm2 |
| 1487 | 150-185 mm2 |
| 1488 | 240-300 mm2 |
| 1489 | IN DOOR Termination KIT for 22KV(E) XLPE Screened 3 core cable |
| 1490 | 25-50 mm2 |
| 1491 | 70-120 mm2 |
| 1492 | 150-185 mm2 |
| 1493 | 240-400 mm2 |
| 1494 | OUT DOOR Termination KIT for 22KV(E) XLPE Screened 3 core cable |
| 1495 | 25-50 mm2 |
| 1496 | 70-120 mm2 |
| 1497 | 150-185 mm2 |
| 1498 | 240-400 mm2 |
| 1499 | Straight through Joint for 22 KV(E) XLPE Screened 3 core cable |
| 1500 | 25-50 mm2 |
| 1501 | 70-95 mm2 |
| 1502 | 120-150 mm2 |
| 1503 | 185-240 mm2 |
| 1504 | 300-400 mm2 |
| 1505 | IN DOOR Termination KIT for 33KV(E) XLPE Screened 3 core cable |
| 1506 | 25-50 mm2 |
| 1507 | 70-95 mm2 |
| 1508 | 120-185 mm2 |
| 1509 | 240-400 mm2 |
| 1510 | OUT DOOR Termination KIT for 33 KV(E) XLPE Screened 3 core cable |
| 1511 | 25-50 mm2 |
| 1512 | 70-95 mm2 |
| 1513 | 120-185 mm2 |
| 1514 | 240-400 mm2 |
| 1515 | Straight through Joint for 33 KV(E) XLPE Screened 3 core cable |
| 1516 | 35-70 mm2 |
| 1517 | 95-150 mm2 |
| 1518 | 185-300 mm2 |
| 1519 | 400 mm2 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 ยท All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail