| 1 | BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: PROVN OF DEFICIENT LIVING IN ACCOMODATION AT AF STN JORHAT Contract No: CE(AF)SZ/JOR/ OF 2026-27 File No: 88685/JOR/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | SCHEDULE \\"A\\" Part - I (BUILDINGS/STRUCTURES WORK)Construction of single living accn with permanent specification for Sgt and equivalent 32 Nos (01 block of G+1) complete all as specified and as shown in drawing. |
| 3 | SCHEDULE \\"A\\" Part - I (BUILDINGS/STRUCTURES WORK)Construction of car parking shed with permanent specification for 06 Nos car (01 block ) complete all as specified and as shown in drawing. |
| 4 | SCHEDULE \\"A\\" Part - I (BUILDINGS/STRUCTURES WORK)Construction of scooter parking shed with permanent specification for 26 Nos scooter (01 block ) complete all as specified and as shown in drawing. |
| 5 | SCHEDULE \\"A\\" PART- II (SITE CLEARENCE, DEVELOPMENT & EARTHWORK) Details of prepriced Schedule is given in tender documents |
| 6 | SCHEDULE \\"A\\" PART- III(INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 7 | SCHEDULE \\"A\\" PART- IV(INTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 8 | SCHEDULE \\"A\\" PART- V(SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents. |
| 9 | SCHEDULE \\"A\\" PART- VI(FENCING AND GATE)Details of prepriced Schedule is given in tender documents |
| 10 | SCHEDULE \\"A\\" PART- VII(AREA DRAINAGE)Details of prepriced Schedule is given in tender documents |
| 11 | SCHEDULE \\"A\\" PART- VIII(ROAD, PATH & CULVERT)Details of prepriced Schedule is given in tender documents |
| 12 | SCHEDULE \\"A\\" PART- IX(EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents |
| 13 | SCHEDULE \\"A\\" PART- X(EXTERNAL ELECTRIC SUPPLY)Details of prepriced Schedule is given in tender documents |
| 14 | SCHEDULE \\"A\\" PART- XI(COOLING APPLIANCES)Details of prepriced Schedule is given in tender documents |
| 15 | SCHEDULE \\"A\\" PART- XII(HOT WATER SUPPLY)Details of prepriced Schedule is given in tender documents |
| 16 | SCHEDULE \\"A\\" PART- XIII(DISMANTLING/DEMOLITION)(E/M PORTION)Details of prepriced Schedule is given in tender documents |
| 17 | SCHEDULE \\"A\\" PART -XIV (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only. |
| 18 | INTERNAL ELECTRIFICATIONS&F Modular type MCB protected Socket Box having metal flush box with PVC cover plate with one single pole MCB 20 Amps and One 20 A 3 pin Power Socket with 3 Pin 20 A Plug Top, complete all as specified and directed.Note : One Switch of 20A to be fixed outside bathroom/kitchen etc. to control the Power Point and switch cost will be paid seperately. |
| 19 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connected to board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:2:4) type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I (2009) complete all as specified and directed.Note: Cost of GI wire earth lead of 4 mm dia from earth electrode to test point upto 7.5 metre shall deemed be included in the quoted rates. |
| 20 | INTERNAL WATER SUPPLYSupply and fixing angle cock 15mm bore, cast copper alloy chromium plated with long shank and cup, fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe, complete all as specified and as directed. |
| 21 | Supply and fixing shower rose 15 mm bore, cast copper alloy chromium plated with long shank and cup, fancy type, of min length 300 mm, complete all as specified and as directed. |
| 22 | SEWAGE DISPOSALM&L for RCC Septic tank designed to carry sewage and sullage water, with upflow fillter, excavation in any type of soil, PCC (1:4:8) below foundation, RCC M-30 Design Mix in walls , base slab , baffle walls and roof slab including beams etc with vent shaft , manhole openings with cover connection etc.,complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users, complete all as specified and as directed. |
| 23 | M&L for soakage wells excavation, in any type of soil, foundation in PCC (1:3:6), walls of honey combed masonry with top ring of M-30 concrete including intercepting chamber and screen chamber made of brick masonary in M-30/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia X 3.0 M effective depth, complete all as specified and as directed. |
| 24 | EXTERNAL WATER SUPPLYM&L for construction of brick masonary valves pit of internal dimensions 1000mm x 1000 mm x 1000 mm complete and fabrication of 3.0 mm thick MS sheet cover and angle iron frame made out of 40mm x 40mm x 6mm MS angle iron and one side provided with hinge with locking arrangment & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and as directed. |
| 25 | M&L for construction of brick masonary valves pit of internal dimensions 600mm x 600 mm x 600 mm complete and fabrication of 3.0 mm thick MS sheet cover and angle iron frame made out of 40mm x 40mm x 6mm MS angle iron and one side provided with hinge with locking arrangment & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and as directed. |
| 26 | EXTERNALELECTRIC SUPPLYM&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and galvanised iron strip of size 32 x 6mm as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connected to board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC (1:2:4) type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I (2009) complete all as specified and directed.Note: Cost of galvanised iron strip of size 32 x 6mm from earth electrode to test point upto 7.5 metre shall deemed be included in the quoted rates. |
| 27 | Labour only for horizontal boring for passing protection pipe up to 40-100mm bore (dia), under road /foot path, not exc. 10.00 mtr in a single length, complete all as specified and as directed. Note : Pipe to be measured and paid separately. |
| 28 | Design, supply, erection, testing and commissioning KIOSK outdoor type LT feeder pillar box, platform mounted, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Copper bus bar for distribution system and type tested at CPRI, fabricated in factory having modern fabrication and testing facility which includes seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings (FD PANEL SGT SINGLE LIVING ACCN).BUS BARS AND INTERNAL CONNECTIONS : The bus bars shall be made of Copper, duly insulated with 1100 Volts grade standard colour coded PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP/SMC/DMC material. All phase bars and as well as the neutral bars also shall be of size 25mm x 5mm For all internal connections from main bus bars to switch gears shall be carried out with 1100 Volts grade FR PVC insulated copper wire of suitable size but not less than 1.5 times current carrying capacity of individual switch gears. |
| 29 | (Item Sl No 23 Contd......)The extended bars from switch gears to cable alley (for terminating the LT UG aluminium cables) shall be made of aluminium bars having suitable cross sectional area but not less than 1.5 times current carrying capacity of individual switch gears, they shall be duly insulated with 1100 volts grade standard colour coded PVC sleeves, 2 Nos Earthing terminating points shall be provided in the side wall as per standard practice.PROVISION FOR CABLE ENTRY :- The provision for cable entry/exit shall be provided in the bottom for both incoming and outgoing cables.CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.(a) INCOMING: MCCB 63 Amp, 25 KA 4 pole 415 Volt -1No(b) OUTGOING: (i) MCCB 63 Amp, 16 KA 4 pole 415 Volt -2 Nos (ii) SPN 20 AMPS, 10 KA - 3 Nos(iii) TPN 20 Amps, 10 KA - 01 No.(iv) Contactor TPN AC1 rating 20 Amps - 01 No.(v) Digital time switch with astronomical function - 01 No.INDICATING DEVICE (i) LED indicating lamps for main supply and out going indicating 'R, Y, B'(ii) Instrument fuse holder, fused 20 amps(iii) Volt meter 0-500 V digital with selector switch(iv) Digital Ammeter of range 0-125 Amps and 125/5 amps with CTs ratio and selector switch |
| 30 | S&F cable junction box 200X160X98 mm in size made out of thermoplastic sheet having IP 65 protection for outdoor installation fixed with 4 way backelite cable terminals incl 03 Nos polymade gland with check nut fixed on poles with flate iron clamp of size 25 X 3 mm nuts , bolts, washer etc incl applying two coat synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed |
| 31 | M&L for Lightning arresters HT 11 KV expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp complete all as specified and as directed. |
| 32 | COOLING APPLIANCESSupply and fixing Voltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 130V to 290 V with output voltage stabilzed at 230 V with accuracy of ± 2.5 % of capacity 1 KVA, complete all as specifed and as directed. |
| 33 | Note:- Schedule of credit (Sch 'A' Part- XV) amount of Rs 32,314.10 shall be deducted from the total quoted amount of BOQ. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |