Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #55942956

Tender for Addition Alteration to Bldg no P-11 & P-13 at 17FBSU, Trivandrum

Issued by Statutory Bodies & Commissions/Committees · Trivandrum, Kerala
Tender Value
75.44 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
1 days left
EMD
1.38 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Trivandrum → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addition Alteration to Bldg no P-11 & P-13 at 17FBSU, Trivandrum

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 25-Jun-2026 82662 Corrigendum BOQ 09-Jul-2026

BOQ

Name of Work:- ADDN/ALTN TO BLDG NO P-11 & P-13 AT 17FBSU, TRIVANDRUM.
Sl. No. Item Description
1Taking down chowkats or frames area n.exc 1.5 sqm each with shutters (without taking off shutter from the frames) complete all as specified & as directed.
2Taking down chowkats or frames area exc 1.5 sqm but n.exc 4 sqm each shutters (without taking off shutter from the frames) complete all as specified & as directed.
3S&F factory made uPVC white Sliding window (area not exceeding 2.00 sqm each) three track made of extruded profiles with wall thickness of 2.3 mm (± 0.2 mm). Window profile with hollow section with multi chamber, Frame (60 mm x 62 mm). sash (42 mm x 67 mm). Sliding Interlock (One vertical length in each shutters) (45.5 mm x 28 mm). Glazing bead (24.5 mm x 16 mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 ±0.2 mm thick galvanized steel frame (30 mm x 21.5 mm), Sash (30 mm x 18 mm), profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners. Hardware : [Touch Lock of zinc alloyed (white powder coated), steel roller system including 5mm thick glazing with selected quality glass, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock.]Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose complete all as specified & as directed.
4All as per item no.3 above but for uPVC window area exceeding 2.00 Sqm each
5S&F factory made uPVC openable window/ ventilator single panel as per following details.(A) Outer frame for double leaf shutter.(B) Openable shutters with suitable hinges for both glazed and gauzed (Wire mesh) shutters. (C) Suitable handles and locking system for shutters.Note:- (i) Size of the uPVC sections shall be as per manufacturers catalogue of Villa windows series of M/s OKOTech or equivalent model of other manufacturers complete all as specified and as directed.(ii) For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. (iii) Rate inclusive of making good jambs and reveals etc
6S&F factory made 30 mm thick flush shutter, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/frame to match complete all as specified & as directed.
7S&F 30 mm thick second class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), square with frame plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters a specified in SSR Part I, Section 8, clause 8.24 (a); complete all as specified & as directed.
8M&L for 2nd class hardwood for Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified & as directed.
9M&L for PCC 1:2:4 Type B1 using (20 mm graded stone aggregate) as in hold fast, plinth courses, string courses, lacing courses, parapets and the like including water toughs and including weathering, slightly rounded or chamfered angles and throating complete all as specified & as directed.
10M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three waystraps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified & as directed.
11S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless-steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified & as directed
12S&F sheet glass ordinary quality 4.8 mm thick area n.exc 0.5 sqm in each pane and glazing with oil putty /glazing clips of any description complete all as specified & as directed.
13S&F Figured glass, pin head type and glazing with oil putty in squares area n.exc 0.5 sqm in each pane complete all as specified & as directed.
14S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40mm fixed with aluminium wire staples or fixing with beads to joinery when fixed in panels of joinery, complete all as specified and as directed.
15S&F factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 42x50 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified and as directed.
16S&F factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel Knob type locking system from inside, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. The panel insertion for door shutter shall be 8 to 10 mm thick uPVC sheet as directed.Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality complete all as specified and as directed. Note:- Rate inclusive of glass pane of 6mm thick/ uPVC panels with suitable thickness.
17M&L for 18/19 mm thick prelaminated marine plywood, High quality BWP Marine grade, prelaminated on both side with decorative choice lamination , fixed with stainless steel screws to frame work as in cupboard shutter, study table etc complete all as specified & as directed.
18S&F 250 mm long Aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy. complete all as specified & as directed.
19S&F 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified & as directed.
20S&F 150 mm long extruded aluminium alloy handles fabricated type anodised complete all as specified & as directed.
21S&F 100 mm long MS butt hinges, medium weight cold rolled complete all as specified & as directed.
22S&F 100 mm Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified & as directed.
23S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor Overall length of cover plate 140 mm complete all as specified & as directed.
24S&F Ball catches with 8 mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified & as directed.
25S&F 40 mm dia, stainless steel cupboard knobs fixed with stainless steel nut, screw and washer of , bright finished complete all as specified & as directed.
26S&F Stainless steel 304 grade cabinet hinges soft close suitable for 16 to 20 mm thick shutter, suitable for 500 mm x 800 mm shutters size as in cupboard, kitchen shutters etc including screws and all fittings necessary complete all as specified & as directed.
27Demolition of Cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified & as directed.
28M&L for roughening surfaces of old concrete floor by picking , sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified & as directed.
29M&L for 75 mm thick 1:3:6 Type C-2 (40 mm graded stone as aggregate) as in plinth protection complete all as specified & as directed.
30M&L for 40 mm thick 1:2:4 Type B-1 (20 mm graded stone as aggregate) as in sub base flooring. complete all as specified & as directed.
31M&L for Non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm, in floors over 15 mm screed bed in CM 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified & as directed.
32M&L for glazed coloured ceramic tiles 450 X 300 X 7 mm thick / 350x250x7 mm as in skirting/ dados, set and jointed in neat cement slurry and pointed in white or coloured cement to match , over 10 mm thick rendering in CM 1:4 etc complete all as specified & as directed.
33Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified & as directed.
34M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-sills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & as directed.
35M&L for Providing and laying 60 mm thick factory made Machine pressed precast concrete interlocking paver block of any shape and size conforming to IS 15658-2006 of 60 mm thickness of M30 grade complete all as specified & as directed.
36M&L for sand filling under precast concrete interlocking paver block including watering and consolidation complete all as specified & as directed.
37M&L for Laying and compacting 200 mm thick (compacted thickness) using kankar or laterite spread rolled and consolidated to gradient and camber required complete all as specified and as directed.
38M&L for pre-cast cement concrete block masonry with solid blocks 1:3:6 Type C1(using 20 mm graded stone aggregate) , exc 10 cm in width and setting in CM 1:6, complete all as specified and as directed.
39Taking down cement plaster any description over wall and ceiling surfaces including at any height complete all as specified and as directed
40M&L for Rendering 15 mm thick in CM 1:4 (mixing with liquid water proofing compound) on block/ brick masonry, finished even and smooth without using extra cement complete all as specified and as directed.
41M&L for Rendering 10 mm thick in CM 1:6 (mixing with liquid water proofing compound) to brick work or concrete surface finished even and smooth with out using extra cement complete all as specified & as directed.
42Supply only Liquid water proofing compound of approved make.
43S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & as directed.
44Dismantling wrought iron or mild steel work of any description complete all as specified & as directed.
45S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified & as directed.
46M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified & as directed.
47M&L for MS Framed work such as guard bars; barred iron doors, gate, ladders, railings, framed cable duct and cover with checker plates etc including proper welding etc complete all as specified & as directed.
48M&L for preparation of new wooden surfaces exceeding 10 cm width or girth and applying Two coats of synthetic enamel paint over a coat of pink primer complete all as specified & as directed.
49M&L for preparing new plastered surface and applying two coats of oil bound distemper on walls over a coat of primer, complete all as specified and as directed.
50M&L for preparation of new plastered surface and apply two coats of weather proof coat paint over a coat of primer incl necessary scaffolding etc complete all as specified and as directed
51M&L for preparing old plastered surface and applying one coats of oil bound distemper on walls etc. complete all as specified and as directed
52M&L for preparation of old wall surfaces and apply two coat of weather proof coat paint including necessary scaffolding etc complete all as specified & as directed.
53M&L for preparing old plastered surface and applying two coats of white wash to ceiling complete all as specified & as directed.
54M&L for preparing new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer etc complete all as specified & as directed.
55M&L for Waterproofing: Providing and application of SmartCare PU Magnum Primer which is a two component water based epoxy primer having high abrasion resistance and hardness which can be applied over slightly damp surfaces which is having a density of 1.05 kg/L, viscosity 900 mPa, adhesion to concrete >3 N/sqm which must be applied with a minimum consumption of 90 g/Sqm. Application of Asian Paints SmartCare PU Aqua over the primed surface with 3 coats with a consumption of 1.8 Kg/Sqm which is a single component water based liquid applied poly urethane coating having tensile strength > 1.5 MPa as per ASTM CD 1475, elongation >450% as per ASTM D 2370, crack bridging ability up to 4 mm as per AS-NZ-4548 and having water impermeability 7bar up to 72hrs as per BS EN 12390-B.
56Application: After application of epoxy primer, first coat of PU Aqua is applied without any dilution followed by application of second and third coat of PU Aqua without dilution, each coat must be kept with application interval of 6-7 hours for curing. For gutters before plastering: Cleaning the area properly. Construction joints/cracks, cutting & making v groove in 20x20 mm, and grouting the points with non-shrink grout powder. Filling the v groove area with polymer based repair mortar. Applying one coat SmartCare Ultrablock 2K in v groove area. Cleaning the surface well with wire brush and remove all loose particles. Provide ponding test to find out any leaking points. If any leaking points –pressure grouting the points Providing and applying first coat, two component high performance polymer modified cementitious waterproofing coating, SmartCare Ultrablock 2K @ 2kg per square meter, having minimum elongation of 200%, tensile strength 1 n/mm2 (as per as tm d412). Providing and applying second coat, two component high performance polymer modified cementitious waterproofing coating, SmartCare Ultrablock 2K , @ 1kg per square meter, having minimum elongation of 200%, tensile strength 1 n/mm2 (as per ASTM D412).For underscreed waterproofing: Applying after completion of necessary surface preparation, Asian Paints SmartCare PU Magnum US, PU Based Liquid applied elastomeric membrane with Hydrocarbon free, Non - Toxic formulation and Root resistance when screed applied with Solids content - 85%. SC PU MAGNUM is a single component liquid polyurethane & cures by reaction with atmospheric moisture to form a tough, elastomeric, waterproof membrane.SC PU MAGNUM is designed for use on horizontal and vertical surfaces, covered by a protective screed or render. Elongation >400 % (ASTM D412); Adhesion-in-peel test >50N (ASTM C836); Recovery from 95% elongation (ASTM D412); Tear resistance 15kN/m (ASTM D624-00); Initial Hardness (Shore A) 60 (ASTM 2240); with Dark green in colour SC PU MAGNUM can be applied by brush, squeegee or roller. It is applied at coverage of 2kg per sqm in 2 coats. The second coat should be applied in perpendicular direction to the first coat. SC PU MAGNUM should be protected from UV light not more than 14 days after application. This can normally be achieved by use of a protective screed.
57For under screed: Providing & applying 2 components, SC ULTRON solvent free, liquid applied elastomeric seamless hybrid Polyurea Polyurethane Membrane, over two component epoxy primer to form a minimum system thickness of 1.5 mm in two alternative coats with a total consumption of 1.5-1.6 kg / m2. The membrane shall have 100% Solids, VOC Free, Tensile strength > 15 Mpa as per ASTM D 412, Elongation > 450% as per ASTM D 412, Static Crack bridging up to 2mm as per ASTM C 836, Shore A Hardness > 85 ASTM D 2240, Puncture Resistance > 1000 N as per ASTM E 154, Water Head Resistance > 7 Bar as per ASTM D 5385.The coating should pass Dynamic Crack Bridging as per EN 1062-7, Method B for 20,000 cycles at -20-degree temperature. Apply primer coat of epoxy primer by roller/ airless spray guideline and coverage @ 5-6 m2/ltr depends on porosity of concrete. Allow to cure for max 5-6 hours.Broadcast anti slip grains of 200-300 micron (dried sand) on wet primer at coverage of 0.8-1 kg/m2 and allow to come to touch dry condition before application of Hybrid Polyurea Coating. Quotation to include surface preparation, Tie Rod fixing, Fillet making etc. Termination of Membrane at 300mm above G.L.-The waterproofing membrane shall be terminated on the vertical surface.Including temporary lifting of Water tanks, Pipe line, cable trays etc . and refixing in same position, Demolition and Removal of finishing material e.g. Weather course, cement plastering, APP membrane, Clay tiles, if any etc cleaning work, removal of loose screed. Rate also include material and labour for Cement plastering in CM 1:3, 15mm thick on RCC roof surface finish even and smooth without using extra cement and with using water proofing compound complete all as specified & as directed.
58S&F Stainless steel sink with draining board, made out of 1.00 mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm fixed in repair.
59S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified & as directed.
60S&F in repair Vitreous China wash down water closet pan (pedestal pattern) EWC, white (excluding flushing cistern and flush pipe) including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified & as directed.
61S&F in repairs 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flush pipe and connection to water closet complete all as specified & as directed.
62S&F in repairs 550x400 mm size Vitreous China wash basin, white, with flat back, excluding taps, waste, chain and plug and porcelain stopper but including brackets and including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, complete all as specified & as directed.
63S&F 32 mm dia bore waste fittings brass chromium plated fixed to wash hand basin with long screwed shanks and fly nuts flange and bedded in run lead cement and other end fixed complete all as specified & as directed.
64S&F in repairs 15 mm bore bib tap brass chromium plated fancy type with crutch or butterfly handle screwed down, screwed both ends for PPR Pipe fixed complete all as specified & as directed.
65S&F in repair PVC floor trap plain with grating incl jointing with solvent cement, dia of outlet 75 mm complete all as specified & as directed.
66S&F in repairs Pillar taps CP brass chromium plated fancy type screwed down high pressure with chromium plated screwed shanks and fly nuts complete screwed for 20 mm bore PPR Pipe fixed complete all as specified & as directed.
67S&F in repairs 25 mm dia stainless steel curtain rod including supporting brackets and end caps/dome complete all as specified & as directed.
68S&F brass CP shower rose 125mm dia with arms 100 mm size fixed to pipe all as in repairs complete all as specified & as directed.
69S&F in repair Stop valves, 20mm dia , fancy type, chromium plated with long shank and cup (concealed type), screwed both ends for iron pipe or for unions and fixed complete all as specified & as directed.
70S&F in repair 20 mm dia tubular towel rail chromium plated, D type, 60cm long between flanges including one pair of brackets complete all as specified & as directed.
71S&F in repairs angle valves 20 mm dia cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified & as directed.
72S&F in repairs Stop valves, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 20 mm pipe or for unions and fixed complete all as specified & as directed.
73S&F in repair 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed complete all as specified & as directed.
74S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified & as directed.
75S&F in repairs Vitreous China urinals full stall type white, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in Cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; including supply and fixing 10 lit PVC valveless, syphonic action type fixing with brackets, flush pipe, grating and Union for discharge pipe complete all as specified & as directed.
76S&F in repairs 75mm PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement as complete all as specified & as directed.
77S&F in repairs 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including short lengths, with all pipe fittings such as ends, elbows, unions, hose clips etc. and fixing to walls etc, complete with saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves and cutting through walls, floors and their making good and also cutting, screwing and waste complete all as specified & as directed.
78S & F in repairs 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including short lengths, with all pipe fittings such as ends, elbows, unions, hose clips etc. and fixing to walls etc, complete with saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves and cutting through walls, floors and their making good and also cutting, screwing and waste all as specified and directed
79S&F in repairs PVC(SWR) bend 110 mm bore complete all as specified & as directed.
80S&F in repairs PVC(SWR) bend 75 mm bore complete all as specified & as directed.
81S&F in repairs PVC(SWR) bend 110 mm bore with access door complete all as specified & as directed.
82S&F in repairs PVC(SWR) vent cowl complete all as specified & as directed.
83S&F in repairs 20 mm bore, 3- layer PPR (Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PPR plain & brass threaded polypropylene random fittings incl taking down the existing pipe complete all as specified & as directed.
84S & F in repair 25 mm bore, 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings incl taking down the existing pipe complete all as specified and as directed
85M&L for Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre.
86M&L for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia. 40mm long complete all as specified & as directed.
87Providing and fixing 10mm thick Plaster of Paris ceiling (Gypsum anhydrous) to flat surface over metal frame work and reinforced with G.I. wire mesh finished with two coats of primer and one coat of white plastic emulsion paint of approved brand complete all as specified & as directed.Note:- GI metal frame work and G.I. wire shall be measured and paid separately)
88S&F in replacement steel chromium plated round grating 100 mm dia., fixed in position in cement mortar (1:3) complete all as specified & as directed.
89M&L for RCC 1:2:4 Type B-1 (using 20 mm graded aggregate) for slab supported on walls, beams, and column in floors, desk slabs and in shelves etc. complete all as specified & as directed.
90Form work to soffits of suspended slabs flat surface of concrete finished rough surfaces of concrete n.exc 200 mm thick, complete all as specified & as directed.
91M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending and binding with and including annealed MS wire not less than 0.90 mm dia complete all as specified & as directed.
92Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise n.exc 100 sqm complete all as specified & as directed.
93Dismantling of Mangalore pattern roofing tiles with ceiling tiles or slate roofing complete all as specified & as directed.
94M&L for Mangalore pattern roof tiles interlocking at side joints laid dry in patches repair of chajja projection as per existing size & shape etc. complete all as specified & as directed. by Engr-in-Charge.
95S&F in repairs for 1000 ltrs capacity white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including tank nipple, float valve etc. as after removing existing water tank complete all as specified & as directed.
96Taking down aluminium/Copper point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, sunken MS boxes etc. removing materials to store for taking credit and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distemper to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified & as directed.
97M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm single core PVC insulated FRLSH cable 1100 Volts grade ISI-694 marked with valid CML No. multistranded copper conductor drawn in and including heavy duty concealed PVC conduit and all conduit accessories (ISI marked) concealed and including provision of 1.5 sqmm PVC insulated copper cable FRLSH ISI marked as earth continuity conductor fabricated branded Modular metal flush box concealed in walls with Modular suitable plate with cover with suitable screws for housing switches socket outlets fan regulators etc. complete all as specified & as directed for One light point controlled by one switch.
98All as per item No 95 here in before but for one ceiling fan/exhaust fan point controlled by one switch/ceiling fan regulator.
99All as per item No. 95 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
100All as per Item No 95 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
101M&L for sub main wiring with PVC insulated unsheathed FRLSH 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC rigid conduit and all accessories fixed concealed to wall/floors along with one run of 4 sqmm PVC insulated unsheathed FRLSH copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor PVC conduit shall be measured as one length including taking down UNSV old wiring.
102M&L for sub main wiring with PVC insulated unsheathed FRLSH 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC rigid conduit and all accessories fixed concealed to wall/floors along with one run of 6 sqmm PVC insulated unsheathed FRLSH copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size.Note: 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor PVC conduit shall be measured as one length including taking down UNSV old wiring.
103S&F in repairs Modular Switch 6 Amps, 1 module, 1 Way complete all as specified and as directed.
104S&F in repairs Modular Switch 6 Amps, 1 module, 2 Way complete all as specified and as directed.
105S&F in repairs Modular socket 6 Amps, 2 module, 2/3 pin multi purpose flush complete all as specified and as directed.
106S&F in repairs Modular Switch 16 Amps, 1 module, 1 Way complete all as specified and as directed.
107S&F in repairs Modular socket 2 module, flush type multi purpose 6A/16A-6 pin combined complete all as specified and as directed.
108S&F in repairs Modular Fan Regulator Step type (360 Degree rotatable), 2 Module 120W complete all as specified and as directed.
109S&F in repairs Ceiling rose 65x50mm surface PVC / Polycarbonate, isolated body with 3 terminals complete all as specified and as directed.
110S&F in repair for AC box Modular socket type with MCB SP 25 Amps 10 KA operating on 240 volts AC with plug top complete all as specified and as directed.
111S&F in repairs Modular white cover plate with frame of 1/2 module complete all as specified and as directed.
112S&F in repairs Modular white cover plate with frame of 3 module complete all as specified and as directed.
113S&F in repairs Modular white cover plate with frame of 4 module complete all as specified and as directed.
114S&F in repairs Modular white cover plate with frame of 6 module complete all as specified and as directed.
115S&F in repairs Modular white cover plate with frame of 8 module complete all as specified and as directed.
116S&F in repairs Modular white cover plate with frame of 12 module complete all as specified and as directed.
117S&F in repairs modular metal flush box of 1/2 module complete all as specified and as directed.
118S&F in repairs modular metal flush box of 3 module complete all as specified and as directed.
119S&F in repairs modular metal flush box of 4 module complete all as specified and as directed.
120S&F in repairs modular metal flush box of 6 module complete all as specified and as directed.
121S&F in repairs modular metal flush box of 8 module complete all as specified and as directed.
122S&F in repairs modular metal flush box of 12 module complete all as specified and as directed.
123Labour only for removing of ceiling fan from ceiling by disconnecting all electric connection and spray painting in situ with one coat of synthetic enamel white paint, filling cavities with filler after cleaning all dust/foreign materials and hanging only after completion of E/M and B&R works and connecting up including provision of three core copper cable of suitable size from ceiling rose or connector to fan and testing complete all as specified and as directed.
124Labour only for removing of exhaust fan metal body AC single phase 230V of size 300/380mm from wall by disconnecting all electric connection and spray painting in situ with one coat of synthetic enamel white paint, filling cavities with filler after cleaning all dust/foreign materials and fixing only after completion of E/M and B&R works with anchor bolt of suitable size and connecting up including provision of three core copper cable of suitable size from ceiling rose or connector to fan and testing, making the surface good with the existing complete all as specified and as directed.
125S&F in repair fancy type angle Lamp holder with metal brass ring and fire retardant Polycarbonate outer housing fascia with back plate suitable for batten fittings alongwith LED bulb of 3/5W complete all as specified and as directed.
126S&F in repair MCB DB with sheet metal enclosure double door type concealed on wall Triple pole and neutral 4 way 415V with 200A rated bus bar complete all as specified and as directed.
127S&F in repair MCB DB with sheet metal enclosure double door type concealed on wall single pole and neutral 12 way 240V with 200A rated bus bar complete all as specified and as directed.
128S&F in repair MCB DB with sheet metal enclosure double door type concealed on wall single pole and neutral 8 way 240V with 200A rated bus bar complete all as specified and as directed.
129S&F in repair MCB DB with sheet metal enclosure double door type concealed on wall single pole and neutral 4 way 240V with 200A rated bus bar complete all as specified and as directed.
130S&F RCBO for earth leakage, overload and short circuit protection 63A , Four pole 300mA complete all as specified and as directed.
131S&F in repair 40 to 100 Amp rating 415V, 10KA 'C' curve miniature circuit breaker (MCB) of Triple pole and Neutral in the MCB DB complete with connection testing and commissioning.
132S&F in repair 5 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole and Neutral in the MCB DB complete with connection testing and commissioning.
133S&F in repair 5 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning.
134M&L for replacing of existing earthing complete by using GI earth plate electrode 60cm × 60cm × 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less 'than 1.5 meters below normal ground level, connected to using GI earth lead of size 4mm dia by means of bolts, nuts, check nuts and washers etc made of galvanised iron and protected by galvanised iron light grade 25 mm bore & 20mm dia galvanised medium grade for watering and including funnel, wire mesh, RCC 1:2:4 cover slab 50 mm thick with re-inforcement of 8 mm TMT bars @ 100mm c/c both directions and PCC chamber with PCC 1:3:6 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m, charcoal, lugs, common salt complete all as specified and as shown on plate No.3 of SSR Part-I . Please Enable Macros to View BoQ information
135M&L for replacing of existing earthing complete by using GI earth plate electrode 60cm × 60cm × 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less 'than 1.5 meters below normal ground level, connected to using GI earth lead of size 4mm dia by means of bolts, nuts, check nuts and washers etc made of galvanised iron and protected by galvanised iron light grade 25 mm bore & 20mm dia galvanised medium grade for watering and including funnel, wire mesh, RCC 1:2:4 cover slab 50 mm thick with re-inforcement of 8 mm TMT bars @ 100mm c/c both directions and PCC chamber with PCC 1:3:6 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m, charcoal, lugs, common salt complete all as specified and as shown on plate No.3 of SSR Part-I . Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55942956
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 75.44 Lakhs
LAST DATE 09-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addition Alteration to Bldg no P-11 & P-13 at 17FBSU, Trivandrum
Basic Detail
Tender No 82662/E8
Bidding Type Tender
Location
City Trivandrum
State Kerala
Key Dates
Publish Date 25 Jun 2026
Submission Date 09 Jul 2026
Open Date 01 Jan 0001
Finance
Tender Value 75.44 Lakhs
Tender Fee 1000
EMD 1.38 Lakhs
Exemption Available
Document List
2d3a80b0-998e-4c57-a2ce-4ccf83672257.html
BOQ_863999.xls
Tenderdocumentsmerged.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Jul 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

2d3a80b0-998e-4c57-a2ce-4ccf83672257.html

xls

BOQ_863999.xls

pdf

Tenderdocumentsmerged.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders