| 1 | Taking down ceiling fans of any size, cleaning, oiling and greasing throughly and spray painting with super enamelled paint (white) and refixing at the existing site/rooms and connected with 0.5 sqmm PVC insulated overall PVC sheathed three core PVC flexible copper cable from ceiling rose to fan etc complete all as specified and directed. |
| 2 | Taking down exhaust fans of any size, cleaning, oiling and greasing throughly and spray painting with super enamelled paint (existing color) and refixing at the existing site/rooms and connected with 1.00 sqmm PVC insulated overall PVC sheathed three core PVC flexible copper cable from ceiling rose to fan etc complete all as specified and directed. |
| 3 | Supply, assembling, hanging, fixing & testing ceiling fans complete with blades, down rods, electronic regulator and all strandard accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) incl marking the MES Number and making connection with PVC insulated & sheathed 1.00 sqmm three core flexible copper multistranded conductor cable form ceiling rose to fan, dismantling of old ceiling fans of any sizes and deposited to MES store yard complete all as specified and directed by Engr-in-ChargeNote :- (i) The font, style and place of writing MES number with synthetic enamel paint shall be as directed by EIC |
| 4 | All as per item No. 3 above but for exhaust fan of size 450mm sweep heavy duty metal body copper winding motor complete as specified and directed. |
| 5 | All as per item No.3.0 above but for exhaust fan of size 300mm sweep heavy duty metal body copper winding motor complete as specified and directed. |
| 6 | All as per item No. 3 above but for exhaust fan PVC body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete as specified and directed. |
| 7 | All as per item No. 3 above but for exhaust fan PVC body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete as specified and directed. |
| 8 | All as per item No. 3 above but for exhaust fan metal body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete as specified and directed. |
| 9 | S&F in replacement of condenser carrier clip (PVC) in built connector two way fixed with screw on down rod or housing complete all as specified and directed. |
| 10 | S&F in replacement of upper set of clips for down rod with rubber Bush (Garari) including set of nut bolts and washer, pin complete all as specified and directed. |
| 11 | S&F in replacement of rubber bush (Garari) for mounted at upper side of down rod clip complete all as specified and directed. |
| 12 | S&F in replacement gun metal bush self lubricated for ceiling fan of size 1200mm/1400mm complete all as specified and directed |
| 13 | S&F in replacement 2 Core Flexible Copper Wires and Cables 40/76 stranded 1100 Volt PVC insulated cable complete all as specified and directed. |
| 14 | S&F in replacement fan capacitor, 230 Volts, 2.5 MFD capacity (ISI Marked), complete all as specified and directed. |
| 15 | S&F in replacement fan capacitor, 230 Volts, 3.15 MFD capacity (ISI Marked), complete all as specified and directed. |
| 16 | S&F in replacement ball bearing, of size 6202'ZZ' make NBC/ SKF/TATA complete all as specified and directed. |
| 17 | S & F in replacement PVC Canopy for ceiling fan of any size, complete all as specified and directed. |
| 18 | Supply and fixing in replacement Exhaust fan metal blade duly painted suitable for 380mm/250mm sweep complete all as specified and directed . |
| 19 | Supply and fixing in replacement outer flap cover suitable for 300 mm / 250 mm sweep sheet type exhaust fan complete all as specified and directed. |
| 20 | S&F in replacement of fan blade suitable for 1200mm sweep ceiling, fan complete with new screws Complete all as specified and directed. |
| 21 | S&F in repair five Stepped type electronic fan regulator, flush type 120 watt, 240 Volt 50 Hz AC, on existing phenolic laminated sheet, complete all as specified and directed. |
| 22 | Taking down old unserviceable LED light fitting of any description and in any position complete all as specified and directed. |
| 23 | Supply and fixing LED lights fitting 4 feet, 20W, 220V, AC decorative box type with driver, holder including LED tube light including connection with three core flexible copper conductor cable of suitable size from ceiling rose, having luminaire output not less than 2000 lumens complete all as specified and directed. |
| 24 | S&F in replacement 2 feet, 10 watt, 220 volt AC mirror type decorative LED light fitting with high output diffuser, holder & LED lamp including connection with three core flexible copper conductor cable of suitable size from ceiling rose, having luminaire out put not less than 1000 lumens complete all as specified and directed. |
| 25 | S&F in replacement of Reserve Plus Rechargeable emergency Inverter LED Batten, 20 Watt Compact 4-feet LED tubelight, cool day light, having minimum 4 hrs back up time, battery capacity 5200 mAh and luminaire out put not less than 2000 lumen complete all as specified and directed. |
| 26 | S&F in repair of SP MCB 32 Amp, 240 Volt, 'C' curve, 10 KA complete all as specified and directed. |
| 27 | S&F in repair of MCB, SPN 40-63 Amp, 240 Volt, 'C' curve, 10 KA, complete all as specified and directed. |
| 28 | S&F in repair hylam sheet cover of size 125 mm x 125 mm x 3mm thick complete all as specified and directed.(Note : Desired size cutting for any number of switchs/sockets/fan regulators nut including washers & re-fixing shall be included) |
| 29 | All as per item No.27 above but for size 200 mm x 125 mm. |
| 30 | All as per item No.27 above but for size 225 mm x 270 mm |
| 31 | S&F in repair ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed. |
| 32 | S&F in repair Switch Piano Flush type 6 Amp single pole one way complete all as specified and directed |
| 33 | S&F in repair 6 Amp, 5/3 Pin socket complete all as specified and directed |
| 34 | S&F in repair 16 Amp, one way switch, complete all as specified and directed |
| 35 | S&F in repair 16 Amp, 5 Pin socket complete all as specified and directed |
| 36 | S&F in repair 15/16 Amp, 3 Pin plug top complete all as specified and directed |
| 37 | S&F in repair 5/6 Amp, 3 Pin plug top complete all as specified and directed |
| 38 | S&F of oscillating Wall Mount fan, of size 400 mm sweep with copper winding motor, single phase, AC supply, 230 V power consumption not more than 60 Watt, 3 blades, 3 speed, Switch Push Button type, with and including MS clamp etc for fixing suitable for dining room, home office, kitchen & living room, complete incl marking the MES number, dismantling of old ceiling fans of any sizes and deposited to MES store yard complete all as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |