Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #55942394

Tender For Periodical Services For Painting Of Various Buildings, Security Wall Maintenance Of Sewage Networks, Compound Wall, Security Wall At Khojatoli, Maintenance Of Storm Water Drains, Damages Barbed Wire, Concertina Coil, Footpath At Namkum And

Issued by Statutory Bodies & Commissions/Committees · Ranchi, Jharkhand
Tender Value
33 Lakhs
Estimated cost
Bid Submission
14 Jul 2026
1 days left
EMD
66000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Periodical Services For Painting Of Various Buildings, Security Wall Maintenance Of Sewage Networks, Compound Wall, Security Wall At Khojatoli, Maintenance Of Storm Water Drains, Damages Barbed Wire, Concertina Coil, Footpath At Namkum And Maintenance Of Unsv Point Wiring Security Light At Namkum And Khojatoli Under Ge Ranchi

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-Jul-2026

BOQ

Name of Work:- PERIODICAL SERVICES FOR PAINTING OF VARIOUS BUILDINGS, SECURITY WALL MAINT OF SEWAGE NETWORKS, COMPOUND WALL, SECURITY WALL AT KHOJATOLI, MAINT OF STORM WATER DRAINS, DAMAGES BARBED WIRE, CONCERTINA COIL, FOOTPATH AT NAMKUM AND MAINT OF UNSV POINT WIRING SECURITY LIGHT AT NAMKUM AND KHOJATOLI UNDER GE RANCHI
Sl. No. Item Description
1M & L preparing old decorated surfaces, plastered or unplastered and applying one coat of white wash on walls of buildings Complete..
2Description all as per item No 1 above but two coat of white (lime) wash as required basis complete.
3Description all as per item No 1 above but on ceiling.
4Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc
5M & L rendering 15 mm thick in CM 1:6 in on surface of walls and finished even and fair (without using extra cement) in patches.
6M & L rendering 5 mm thick in CM 1:4 in on surface of ceiling and finished even and fair (without using extra cement)
7M & L preparation of new plastered surfaces of walls and applying two coats of oil bound distemper on walls , white or tinted over a coat of chalk whiting, complete all as specified & directed
8M & L preparation of new plastered/untreated surfaces and applying two coats of white wash on ceiling surfaces complete all as specified & directed.
9M & L preparation of old decorated surfaces and applying one coat of oil bound distemper on walls including filling of holes and make good , white or tinted complete as directed by EIC.
10Description all as per item No 09 above but but on ceiling
11M & L preparation of old decorated surfaces of any description by washing, rubbing down and applying two coats of oil bound distemper on walls by including filling holes and make good, white or tinted complete as directed.
12M & L preparation of old painted wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint),any colour as directed.
13Description all as per item No 12 but wooden surfaces of any description n.exc 10 cm width or girth when unconnected with other painting or when painted in different tint
14M & L preparation of old painted surfaces of steel work of any description, not otherwise described, over 10 CM width or girth and applying one coat of synthetic enamel paint, any colour as directed
15Description all as per item No 14 but steel surfaces of any description n.exc 10 cm width or girth when unconnected with other painting or when painted in different tint
16M&L for preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm width or girth and change of existing colour including removal of scaled paint where ever required and applying two coats of synthetic enamel paint complete all as specified and as directed
17M&L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and change of existing colour including removal of sclaed paint and applying two coats of synthetic enamel paint over a coat of red oxide primer for change of existing colour complete all as specified and as directed.
18Writing letters or figures( Block, Roman, Italic or Indian) n exc 30 CM high complete all as specified and as directed.
19Stops, Commas, Short lines, Dashes, Hyphen, Brackets etc complete all as specified and as directed.
20M&L wall care putty 2mm thick including necessay preparation or already prepared surface complete all as specified and directed.
21M & L for repairing broken edges of chajja's, roof projection, Fascias etc . In small widths/depths ( exposed area not exc 0.16 Sqm ) by breaking the cracked/loose portion and filling with Cement Mortar / Plain Cement Concrete 1:2:4 ,Type B-0 , using 12.5 mm Crushed stone aggregates , over GI wire mesh, giving a coat of anti corrosive paint to exposed Reinforcement and using coat of anti corrosive paint to exposed Reinforcement and using chemical for bonding old and new concrete/plaster and finishing with CM 1:3 plastering, incl 2 coats of white wash to match the exisitng surfaces incl removing debris , necessary scaffolding , etc all as specified and directed. Note : (i) Reinforcement & formwork shall be provided if necessary. (ii) Necessary scafolding & safty measure upto (G+1) 8m height of Bldgs also incl in rope.
22Description all as per ser item No 21 above herein before but exposed area exc 0.16 Sqm but not exc 0.5 Sqm
23Demolition of Cement concrete of any description and in any position not otherwise specifically provided for
24M&L for 75 mm thich PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed
25Material & labour for prepolished chequered cement concrete tiles 30cmx30cmx20-25mm thick set, jointed and pointed in neat cement slurry in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified & directed.
26Dismantling of Stone sett paving laid dry or laid dry and pointed of any description or thickness in floors,apron complete all as specified,
27M&L prepolished Machine pressed precast concrete coloured Inter locking paver block of any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment over sand cushion & laid over sub base all as specified and directed.
28Description all as per item No 27 above but expect tiles
29M & L Sand filling under floors including watering and consolidation
30M&L Cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in levelling course, coping, window cill etc complete.
31Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete.
32M&L brick work with sub class 'B' brick straight or curved on plan exc 6m means radius build in cement mortar 1:6
33Dismantling fencing wire mash any type and size
34Dismantling posts/pillers or struts (Wood, Steel, or RCC) any section, including taking out embedded portion post embeded in concrete and making good disturbed ground.
35Excavating in post holes Hard/dense soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface
36M&L PCC 1:3:6 type C2 using 40 mm graded stone aggr as in foundation filling and mass concrete complete all as specified.
37S&F Galvanized 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type or standard rails straining balte, including securing or tying at crassing with provision of Galvanised mils steel wire staple pine etc as directed (each line wire to be mesured)
38S&F MS angle iron posts and struts in fencing/gates including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming
39S & F only Mild steel in flat, round bars, in available lengths quality con-forming to Fe- 290 (Gde E- 165)
40Supply only 3.15mm dia GI wire 108x108 mm mesh (chain link fencing) made up to mattresses or cages lapped wired and laid in position including closing and tied with posts properly comlete all as directed.
41Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire
42S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut exc 5 cm long but n exc 150 mm & dia of neck 11 to 15mm Complete
43M&L for preparation of new steel surafces of any description not otherwise described , not exc 10 cm width or girth , priming with a coat of red oxide primer and applyinng 2 coats of synthetic enamel paint of approved shade all as specified and directeed by EIC
44Preperation of newly steel surface of any description ,not otherwise described over 10cm witdth or girth and applying two coat of synthetic enamel paint over a coat of pink primer all as spd and directed
45Cleaning of blockage of Indian / european type WC up to first manhole and making the drain pipe of any dia fully functional by flushing with water to entire satisfaction of Engr-in-Charge including disposal of sludge outside the periphery of defence land at his own arrangement where sanitary hazards do not take place as per directions/ instructions of civil authority and burried in excavated pits complete all as specified and directed. Note:- Unit rate quoted by tenderer shall include clearing blockage, taking out sludge(liquid/semi liquid/solid ) , excavation of borrow pits for dumping sludge ,removing including loading/unloading and transportation etc.
46Cleaning of blockage of Floor/Nahni/vermin trap of Kitchen/Bathroom/basin/sink/urinal etc upto & including gully trap by using hand pump with bucket or manually by rodding till clear flow of water is observed and removing the deposited sludge/solid/liquid material outside MD land, complete all as specified.
47Cleaning of blockage of under ground sewer lines of any dia of pipe including manholes, gully traps etc. by means of cleaning by roding from manholes to manholes / inspection chamber to manholes / gully trap to inspection chamber and flushing after cleaning, taking out sludge collected in manholes, removing & depositing the same outside the periphery of defence land in the pit at a minimum distance of 50 m from nearby living accn and covering the sludge in pit with earth and finally spraying unslaked lime, dry, around the manholes and cover the pit, complete all as specified and directed.Note:-Cost of Taking out sludge, transporting of sludge out side the defence land, earth work & deposition in the pit with & including removing of surbs, grass, small roots etc around manhole, inspection chamber etc where required is deemed to be included in the unit rate to be quoted by tenderer.
48Cleaning of blockage of under ground sewer lines of any dia of pipe by breaking / puncturing of pipe line including excavation in type of soil to depth upto 3mtr deep, removing the blockage and making good the pipe line bedding, relaying of pipe and making good the earth excavated incl redressing complete all as specified and directed.
49Opening of cover (of any description and size) of septic tanks and soakage well/ pits, desludging/ dewatering of septic tanks and soakage well/pits of any size and depth by manually operated machine (where approach for vehicle is not feasible) making it fully functional and removing sludge outside the periphery of defence land at his own arrangement at a minimum distance of 50 m from nearby living accn and burring in excavated pits including spraying of lime over returning filling of sand and covering the same including refixing covers after cleaning complete all as specified and all as directed by Engr-in-Charge. Note: Unit rate quoted by tenderer shall include taking out sludge from septic tank and soakage well/pits in ground with pit by excavation of borrow pits for dumping sludge, removing including loading/unloading and transportation etc.
50Opening of cover (of any description and size) of septic tanks and soakage well/ pits, desludging/ dewatering of septic tanks and soakage well/pits of any size and depth by mechanical pumping truck mounted (having minimum storage capacity of 2500 ltrs) making it fully functional and removing sludge outside the periphery of defence land at his own arrangement at a minimum distance of 500 m from nearby living accn and burring in excavated pits including spraying of lime over returning filling of sand and covering the same including refixing covers after cleaning complete all as specified and all as directed by Engr-in-Charge. Note: Unit rate quoted by tenderer shall include taking out sludge from septic tank and soakage well/pits in ground with pit by excavation of borrow pits for dumping sludge, removing including loading/unloading and transportation etc.
51Cutting and demolition of exising SGSW sewer pipe in damaged portion alongwith concrete bedding including removing unsv materials from site as directed and providing PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and including packing under and haunching against the sides of pipe with PCC 1:3:6 type C-2 using 40 mm graded stone aggregate for 110 mm internal dia of sewer line, complete all as specified and directed.Note:- Earthwork like excavation, returning filling and removal required for the repair of said work shall be inclussived in the rate quoted by the contractor
52Cutting and demolition of exising SGSW sewer pipe in damaged portion alongwith concrete bedding including removing unsv materials from site as directed and providing PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and including packing under and haunching against the sides of pipe with PCC 1:3:6 type C-2 using 40 mm graded stone aggregate for 150 mm internal dia of sewer line, complete all as specified and directed.Note:- Earthwork like excavation, returning filling and removal required for the repair of said work shall be inclussived in the rate quoted by the contractor
53Repairs to Rat / mouse holes to the faces / surfaces of manhole by making good to wall surface, benching, drains / channel etc of sectional area not exc 150sqcm each and depth n.exc 25cm each and filling the same with plain cement Concrete 1:2:4 type-B-1 (using 20mm graded crushed stone aggregate) and finished the surfaces even and fair, complete all as specified and directed.
54Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as specified and directed.
55M&L for Precast reinforced cement concrete (1:2:4) using 20mm graded crushed stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, shelves and similar articles with plain fair faces including chamfers, weatherings, throating etc. and setting in cement mortar (1:6) including necessary form work complete all as specified and directed by Engineer-in-Charge.Note:- Reinforecement shall be measured & paid seperately under relevent item.
56S&F TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia, complete all as specified and directed.
5775mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors fixed in repair all as specified and directed.
5875mm bore PVC (SWR) bends any radius fixed in floor in repair
5975mm bore PVC (SWR) junction single, (Single T) equal or unequal fixed in repair
60110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with GI/Alu clamps fixed in repair all as specified and directed.
61110 mm bore PVC (SWR) bends any radius fixed in repair all as specified and directed.
62110mm bore PVC (SWR) vent cowl fixed in repair all as specified and directed
63M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:4), finished even and fair all as specified and directed.
64M & L for preparing new plastered surfaces of wall and applying two coat of Cement base paint all as specified and directed.
65M & L for preparing old plastered surfaces of wall and applying one coat of Cement base paint all as specified and directed.
66Demoliton of cement concrete in ground floor paving n exc 15cm thickness ( below or above ground level ) complete and debris throwing out side of premises all as specified and directed.
67M&L Cement concrete in in eight,copings, kneelers, apex stones, bed plates, kerbs (1:2:4) type B-1( 20 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismi cand other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in eight,copings, kneelers, apex stones, bed plates, kerbs icluding necessary formwork.
68M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:4), finished even and smooth (Without using extra cement ) complete all as specified and directed.including scafolding up to G+3 story bldg, etc complete.complete.
69M & L preparation of new plastered surfaces of walls/chajja/lintel and applying two coats of cement based paint white or tinted over a coat of alkali resistant primer complete as specified and directed.
70M & L complete removal of existing treatment on wall and applying one coat of Cement base paint all as specified and directed.
71M&Lcomplete removal of existing treatmenton wall and applying two coat of cement paint on Complete removal of existing old surfaces on wall , etc complete all as specified and directed.
72M&L in repair type C1 1:3:6(20mm graded aggregate) precast cement concrete in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham fers, weatherings, throat- ing etc. and setting in mortar 1:4 complete with joints to match all as spd and direcetd
73M&Lin repair Type B0 1:2:4 (12.5mm graded aggregate) precast cement concrete louvres and jallies, 25mm thick (mea sured solid), including all mould (Pre cast frame shall be measured separately and paid) set in cement mortar 1:4 all as spd and direceted.
74M&L PCC (1:2:4) type B1 using 20mm graded stone aggregate in coping etc, including weathering slightly rounded champers angle forming channels & form work
75M&L Cement concrete in surface channels and drains 1:3:6 type C-2 (40mm graded aggregate)as finished the surface even & fair complete all as specified
76M&L forming fair finished drain or channel, 30 cm inner girth, cement concrete finished even and smooth, using extra cement including forms moulds etc.
77Demolition of reinforced cement concrete of any description in any position not otherwise described complete.
78M&L pre cast RCC (1:1.5:3) type A-1 as in manhole cover, drain cover and set in cement mortar (1:4) including necessary formwork complete.
79M&L mild steel TMT bar 10mm dia and over cut length cut to length bent to shape required including cranking bending and binding with MS wire not less than 0.9mm dia or securing clips
80Taking down copper/aluminum pt wiring (light fan, socket or power) complete including fittings such as switch, sockets, c/rose, pendents, regulators, sockets, light fittings, wooden boards, bell push, call bell, regulators etc (credit scheduled for above items should be made as per condition separately) and making good to disturbed wall and surface complete all as specified.
81M&L for concealed conduit Point wiring with 1.5 Sq mm multistranded copper conductor FRLSH PVC insulated and unsheathed cable ISI Marked & drawing in and including non-metallic PVC conduit 20 mm bore medium grade & ISI marked on walls/ceilings/steel frame structure (with necessary arrangement as required at site) including cutting chasing for wiring , pinning in making good & finishing of disturbed surfaces,white wash matching with the existing surface colour & including all conduit fittings, clamps, gutties etc. Point to be for one light controlled by one switch , bell point controled by one bell point and fan point or one fan point controlled by one switch and regulator each including provision of new pressed steel terminal boxes not less then 1.6 mm thick; with provision of new 3 mm thick plastic laminated sheet of and PVC insulated stranded copper continuous earth wire 1.5 Sqmm size FRLS to common earth and connecting to earth dolly, complete all as specified and directed. (Switch/socket, regulators shall be measured & paid for separately). Note- All the wires will be used with approved colour coding and as directed by Engr in-charge.
82Description all as per item 81 above but for 2 pin socket outlet 5 amp on the same board contraolled by separate switch complete all as specified.
83Description all as per item 81 above but for 2 pin socket outlet 5 amp independent but not below the main board In the same vertical plane complete all as specified.
84Description all as per item 81 above but with 2.5 sqmm copper conductor for 15 amp switch socket outlet combination n1. including 1.5 sqmm copper earth wire complete all as specified..
85M&L for PVC casing & Caping Point wiring with 1.5 Sq mm multistranded copper conductor FRLSH PVC insulated and unsheathed cable ISI Marked & drawing in and including in PVC casing & caping & ISI marked on walls/ceilings/steel frame structure (with necessary arrangement as required at site) including cutting chasing (if required) for wiring , pinning in making good & finishing of disturbed surfaces,white wash matching with the existing surface colour & including all in PVC casing & caping fittings, clamps, gutties etc. Point to be for one light controlled by one switch , bell point controled by one bell point and fan point or one fan point controlled by one switch and regulator each including provision of new pressed steel terminal boxes not less then 1.6 mm thick; with provision of new 3 mm thick plastic laminated sheet of and PVC insulated stranded copper continuous earth wire 1.5 Sqmm size FRLS to common earth and connecting to earth dolly, complete all as specified and directed. (Switch/socket, regulators shall be measured & paid for separately). Note- All the wires will be used with approved colour coding and as directed by Engr in-charge.
86Description all as per item 85 above but for 3 pin socket outlet 5 amp on the same board contraolled by separate switch complete all as specified.
87Description all as per item 85 above but for 3 pin socket outlet 5 amp independent but not below the main board In the same vertical plane complete all as specified.
88Description all as per item 85 above but with 2.5 sqmm copper conductor for 15 amp switch socket outlet combination n. including 1.5 sqmm copper earth wire complete all as specified..
89M&L for replacement of switch piano flush button type 6 Amp 240 Volt one way single pole complete all as specified.
90M&L for replacement of switch piano flush button type 15 Amp 240 Volt one way single pole complete all as specified.
91M&L for replacement of bell push button type 5/6 Amp 240 Volt one way single pole complete all as specified.
92Supply and fixing Socket outlet 2 in 1, 3 pin, 5A complete all as specified.
93Supply and fixing Socket outlet 2 in 1, 5 pin, 15/16A complete all as specified.
94Supply and fixing electronic double space rotary step fan 5 speed socket type regulator 120- 280 Volts complete all as specified.
95Supply and fixing ceiling rose surface bakelite 3 terminals 65 x 50mm
96S & F LED light fitting,4 feet ,1x20 watt 230 Volt, 6500k slim body with reflector,drivers,LEDs Astra is a surface & wall mounted LED batten anodized AL housing complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting.Make- Jaquar Cat No BTI -WHTLTBL01X020XC/CG Cat NO TCS-109-20-65-SL-DP-NWH /Bajaj BCLSB20WH.
97S & F LED light fitting,2 feet ,1x10 watt 230 Volt, 6500k slim body with reflector,drivers,LEDs Astra is a surface & wall mounted LED batten anodized AL housing complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting.Make- Phillips Cat No BN012CLED10CWPSU/Crompton Cat NO LCTLN-10-65-NW /Bajaj BCLSB10WH.
98M&L for sheet metal enclosure MCB DB, SPN, 240 volts, 12 way, double door type grouting in wall in CM, making good of disturbed surfaces and matching with existing and electrical connections complete.
99Supply and fixing for sheet metal enclosure MCB DB, IP-43, SPN, 240 volts ,8 way, double door type grouted in wall in cement mortar 1:3 and making electrical connection, complete all as specified and directed and including taking down old DBs and take to schedule of credit.
100Supply and fixing MCB SP, 6 to 32 Amps, 240 volts, 10 KA, 'C' Curve characteristics, including taking out old unserviceable MCB/Isolator, electrical connections and removal from the site complete all as specified and directed.
101Supply and fixing MCB SPN,32 Amps, 240 volts, 10 KA 'C' Curve characteristics, including taking out old unserviceable Isolator & electrical connection and removal from the site complete all as specified and directed.
102Supply and fixing MCB SPN,40 to 63 Amps, 240 volts, 10 KA 'C' Curve characteristics, including taking out old unserviceable Isolator & electrical connection and removal from the site complete all as specified and directed. Make- Legrand/ABB/Indo Asian (optipro).
103Supply and fixing in replacement of TPN Vertical Type Distribution Board, IP-43 protection, fitted with bus bars, neutral links, blanking plates (with out MCCB), 415 volts, 4 way double door type, grouted in wall in cement mortar 1:3 and making good of disturbed surface and matching with existing surface, complete all as specified and directed and including taking down old DBs and take to schedule of credit.
104Supply and fixing in replacement of MCCB, 4P, rated current 100 Amp, breaking capacity 16/18 kA thermal magnetic type and making electrical connection, complete all as specified and directed and including taking down old mccb and take to schedule of credit.
105Supply and fixing sub-main wiring with two single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 2.5 Sq mm drawing in & including medium grade PVC conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 2.5 Sq mm but green in colour for earth DBs and boxes with proper thimbles connecting up and taking down old submain wiring complete all as specified and directed.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM).
106Supply and fixing sub-main wiring with two single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 4 Sq mm drawing in & including medium grade PVC concealed conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 4.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed,.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM).
107Supply and fixing sub-main wiring with two single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 6 Sq mm drawing in & including medium grade PVC concealed conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 6.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM).
108S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
109S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity not less than 25 watts with pre wired, and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
110S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity not less than 45 watts with pre wired, and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
111S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity not less than 60 watts with pre wired, and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge.
112S & F for Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed.
113S & F of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed including taking down old fitting.Make- Phillips/CG/Havells/Bajaj.
114Supply and fixing LED building Security Light Fittings 35 watts of turbo street lights are made up of pressure die cast housing with integrated lenses and high power LED's with IP66 protection. Efficacy ≥ 100LPW and other connected accessories including service bracket of GI pipe 25/32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers as per required at site and making electrical connection with Copper wire 2 core of 1 Sqmm and taking down old unserviceable light any capacity any type complete all as specifiedcomplete all as specified and directed and including taking down old fitting.Make- Phillips/CG/Havells/Bajaj
115Description all as per Item No 114 here in before but capacity 60 watt complete all as specified and directed.
116M & L for XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 sqmm 4 core complete all as specified and directed including taking down old unserviceable cable. NOTE: (i) Earth work shall be measured and paid separately.
117Supply and fix in repairs LED bollard of capacity 10 watt with robust design efficient light distributions die cast powder coated housing with PC diffuser and IP 65 protection with necessary accessories, nuts, bolts, washers complete all as specified and directed.Make- Phillips/CG/Havells/Bajaj.
118Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft /loose soil all as directed.
119Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25 cm all as directed.
120Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
121Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed.(Note: Thickness after punning shall be measured for payment) all as specified and directed.
122M&L for laying bricks 'B' class over a cable (Width wise) old liad dried complete all as specified and directed.
123Demolition of Cement concrete of any description and in any position not otherwise specifically provided for
124M&L for 75 mm thich PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55942394
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 33 Lakhs
LAST DATE 14-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Periodical Services For Painting Of Various Buildings, Security Wall Maintenance Of Sewage Networks, Compound Wall, Security Wall At Khojatoli, Maintenance Of Storm Water Drains, Damages Barbed Wire, Concertina Coil, Footpath At Namkum And Maintenance Of Unsv Point Wiring Security Light At Namkum And Khojatoli Under Ge Ranchi
Basic Detail
Tender No 8200/1716/E8
Bidding Type Tender
Location
City Ranchi
State Jharkhand
Key Dates
Publish Date 09 Jul 2026
Submission Date 14 Jul 2026
Open Date 21 Jul 2026
Finance
Tender Value 33 Lakhs
Tender Fee 500
EMD 66000
Exemption Available
Document List
97c8590d-179b-4ea3-ab60-a3c6e239c1b8.html
BOQ_863921.xls
Tender1716.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Jul 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

97c8590d-179b-4ea3-ab60-a3c6e239c1b8.html

xls

BOQ_863921.xls

pdf

Tender1716.pdf

pdf

Tendernotice_1.pdf