| 1 | Demolition of (unreinforced) cement concerete in ground floors and paving not exceeding 15 cm thickness (below or above GL), complete all as specified and directed. |
| 2 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 4 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 5 | Taking down old pointing, mud plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. including removing of debrie, complete all as specified and directed. |
| 6 | 100 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in sub base, floorings, pavings and similar work complete all as specified and directed. |
| 7 | Fine dry river sand filling under floors, watering, levelling and consolidating complete all as specified and directed. |
| 8 | Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 80mm thickness M-40 grade with grey cement and pigment complete all as specified and directed. |
| 9 | Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment complete all as specified and directed. |
| 10 | Plain cement concrete M-15 (Nominal mix) type B1 (1:2:4) (using 20 mm graded crushed stone aggregate) as in floorings etc., complete all as specified and directed. |
| 11 | Forming contraction (Dummy) joints 75 mm deep x 10 mm wide, filled with sealing compound grade 'A', complete all as specified and directed. |
| 12 | 50mm thick PCC (1:2:4) type B-2 using 40 mm graded crushed stone aggregate as in sub bases, floorings, pavings and similar work complete all as specified and directed. |
| 13 | Cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in cills/ coping/ edging bed blocks including haunching form work, weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and directed. |
| 14 | Plain Cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. |
| 15 | Cement concrete type C-2 1:3:6 (40mm graded crushed stone aggregates) in foundation filling and mass concrete complete all as specified and directed . |
| 16 | Walling of random rubble stone masonry, well bonded, bedded and solidly hearted built in cement mortar 1:6, brought up to courses, complete all as specified and directed. |
| 17 | Pre-cast cement concrete, 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in bond stone set in cement mortar 1:6 and finishing exposed surfaces including necessary form work, complete all as specified and directed. |
| 18 | Raised pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified and directed. |
| 19 | PVC (SWR) pipe 110mm bore single socketed in any length as in weep holes complete all as specified and directed. |
| 20 | Extra for forming fair finished channel or drain of 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred stopped ends etc., complete all as specified and directed. |
| 21 | Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 etc complete all as specified and directed. |
| 22 | 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished even and fair, complete all as specified and directed. |
| 23 | Mild steel TMT bars of Fe 500 or Fe 500D, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed. |
| 24 | MS round bar 6 mm to 8 mm dia cut to length bent to shape required including cranking, bending, hooking ends and binding with MS wire (annealed) not less than 0.9 mm dia, complete all as specified and directed. |
| 25 | Stairs (framed) including stringers, treades, landing,balusters, hand rails etc. including cleats, brackets, Fe 410-W (grade E-250) quality 'A',etc complete all as specified and directed. |
| 26 | Precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded crushed stone aggregate as in drain cover slab set in cement mortar 1:4 including necessary formwork, complete all as specified and directed. |
| 27 | Formwork to sides of concrete foundation, drain wall side etc and similar works fair finished flat surface of concrete complete all as specified and directed. |
| 28 | Dismantling posts or struts embedded in concrete, brick work, masonry, etc. (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground all as specified and directed. |
| 29 | Mild Steel work as in fencing posts and struts fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming toFe-290 grade E-165, complete all as specified and directed. |
| 30 | Mild steel screw bolts (machine made) dia of neck 11 mm to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but not exc. 10 cm long complete all as specified and directed. |
| 31 | Dismantling of fencing wire mesh (Chain link fencing) any type of size complete all as specified and directed. |
| 32 | Supply only chain link MS galvanized fencing, mesh size 50 mm x 50 mm, dia of wire 4mm, of any type complete all as specified and as directed.Note: Weight of chain link shall be ascertained by a BOO to be ordered by the AGE (I). |
| 33 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 34 | Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali, resistant primer complete all as specified and directed. |
| 35 | Preparation of new steel surfaces of any description, over 10 cm in width or girth and applying two coat of synthetic enamal paint and over a coat of red oxide primer complete all as specified and directed. |
| 36 | Preparation of new steel surfaces of any description not exc 10 cm in width or girth not otherwise described and applying two coat of synthetic enamel paint over one coat of red oxide primer. Please Enable Macros to View BoQ information |