Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M & L for preparation of old plastered / unplastered surfaces of ceiling including cornices, pilasters, etc and applying one coat of white wash on ceilings complete all as specified and directed. |
| 2 | M & L for preparation of old plastered / unplastered surfaces of walls including cornices, pilasters, etc and applying one coat of white wash on walls complete all as specified and directed. |
| 3 | M & L for preparation of old distempered surfaces of wall by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil bound distemper on walls complete all as specified and directed. |
| 4 | M & L for preparing old existing treatment surfaces on wall and applying one coat of weather proof acrylic based emulsion paint (exterior grade 100% acrylic) over a coat of primer incuding preparation of old surfaces complete all as specified and directed |
| 5 | M & L for preparing old existing treatment surfaces on wall and applying two coat of weather proof acrylic based emulsion paint (exterior grade 100% acrylic) over a coat of primer incuding preparation of old surfaces complete all as specified and directed |
| 6 | M&L for preparation of old painted wooden surface of any description not otherwise described over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 7 | M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 8 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. including raking out jouints, hacking for key, scrubbing down with water etc. complete all as specified and directed |
| 9 | M & L for rendering 10 mm thick in cement mortar 1:6 on fair faces of brick or conrete wall surface, finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for rendering 15 mm thick on fair face of concrete surfaces in cement mortar (1:4), finished even and smooth without using extra cement complete all as specified and directed. |
| 11 | M & L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting (putty) complete all as specified and directed. |
| 12 | M & L for preparing of new plastered surface of wall and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of any tint as approved over one coat of primer applied as per manufactures instruction complete all as specified and directed. |
| 13 | Preparation of new wooden surface of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 14 | M & L for repairing the edge / corner of chajja / roof projection and similar work by removing of plastered width / girth exceeding 15cm and not exc 30cm and making good with 15cm rendering in cement mortar 1:3 to match with existing surfaces complete all as specified and directed. |
| 15 | S & F mild steel hold fast & similar articles confirming to Fe-290 Gde E-165 complete all as specified and directed. |
| 16 | M&L for cement concrete type B1 1:2:4 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, pacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs complete all as specified and directed. |
| 17 | S&F in repairs 20 mm size ball valve high pressure of PTMT with Epoxy Coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minimum weight 20 mm-210 gms) and fly nut complete screwed for iron pipe and fixed complete all as specified and directed. |
| 18 | S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples to aluminium window sliding / fix type or wooden door / window or steel windows including rubber bead joining cleat for fixing in position, complete all as specified and directed. |
| 19 | Taking down chowkats or frames but with shutters (with out taking off shutter from the frames) exc 1.5 sqm n. exc 4 sqm each complete all as specified and directed. |
| 20 | Taking down chowkats or frames n exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 21 | Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS tube supplying and fixing in opening as per specification and drawing in SSR Part-II complete all as specified and directed. |
| 22 | S&F Factory made solid PVC moulded door shutter with partical board core consisting 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in the frame at site as per specification complete all as specified and directed. |
| 23 | S & F factory made single extruded WPC (Wood Polymer Composite) solid door / window / Ceosetory windows & other Frames / Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed.Note : M.S. hold fast / lugs or SS dash fasteners shall be measured and paid separately. |
| 24 | M&L for providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. Note: Stainless steel butt hinges and necessary S.S screws shall be measured and paid separately. |
| 25 | M & L for 2nd class hard wood, solid straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put to gether with glue pinned at joints complete all as specified and directed. |
| 26 | S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 27 | S&F 2nd class hard wood, 30 mm thick, glazed and skeleton shutter, divided into square, with plain, chamfered or rounded mitred and rebated sash bars, any number of panels, prepared to receive glass, gauge etc. edges of frames chamfered or rounded, fitted with cut and mitred beads for securing glass etc. size of members as specified in SSR Part I clause 8.24 (b) kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 28 | S&F butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed. |
| 29 | S&F butt hinges, medium weight, cold rolled, mild steel of size 75 mm complete all as specified and directed. |
| 30 | S&F aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and directed. |
| 31 | S&F aluminium anodised, barrel tower bolts of extruded section with length of bolt 100 mm and fixed complete all as specified and directed. |
| 32 | S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed. |
| 33 | S&F extruded aluminium alloy handles, fabricated type, anodised of size 100 mm complete all as specified and directed. |
| 34 | S&F aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type)of size 300 mm and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 35 | S&F in repair butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed. |
| 36 | S&F in repair butt hinges, medium weight, cold rolled, mild steel of size 75 mm complete all as specified and directed. |
| 37 | S&F in repair aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and directed. |
| 38 | S&F in repair aluminium anodised, barrel tower bolts of extruded section with length of bolt 100 mm and fixed complete all as specified and directed. |
| 39 | S&F in repair extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed. |
| 40 | S&F in repair extruded aluminium alloy handles, fabricated type, anodised of size 100 mm complete all as specified and directed. |
| 41 | S&F in repair aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type) of size 300 mm and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 42 | S&F aluminium anodised frame for doors windows, vantilators one or more rebated including joining cleat for fixing and powder coating of any colour as approved (thickness of powder coating not less than 50 micron) etc complete all as specified and directed. |
| 43 | Supply fabricate & fix in position aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) three track window (two shutters glazed & one shutters wiregauge) with frame, glazed with 5 mm thick tinted glass and, wire gauge with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm including rubber bead joining cleat for fixing in position, concealed type lock for all three shutter, PVC roller etc all as specified below, including taking down old window complete all as specified and directed. (a) Frame (top & side) section shall be of size 92.00 x 31.75 x 1.50 mm (Section No 20831) (b) Frame (bottom) section shall be of size 92.00 x 31.75 x 1.50 mm (Section No 20832) (c) Top & side Members of shutter Section shall be of size 18.00 x 40.00 x 1.55 mm (Section No 20738) (d) Shutter Interlock Section shall be of size 18.00 x 40.00 x 1.45 mm (Section No 20737) (e) Bottom Members of shutter Section shall be of size 18.00 x 40.00 x 1.55 mm (Section No 20736). Note:- Section No given above are of make Jindal. Contractor may provide any make as given in Appx 'B' to PS. |
| 44 | S&F anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handle 2 nos in each door, hinges and anodised aluminium snap beading screws with 5.5mm sheet glass, ordinary quality and glazing with oil putty in suare exc 0.5sqm in each pane complete all as specified and directed. |
| 45 | S&F in repair aluminium (extruded section body), door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed. |
| 46 | S&F in repairs floor door stopper 140 mm cover plate of aluminium alloy body, double leg type with hard rubber shoe fixed to door complete all as specified and directed. |
| 47 | S & F in repairs for 600mm x 450mm x 5mm thick bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 48 | Material & labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. |
| 49 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 50 | Demolition conctete of any description and in any position complete all as specified and directed. |
| 51 | M&L for cement concrete type B-1, 1:2:4 (using 12.5mm graded stone aggregate) 25mm thick as in leveling course of flooring & roof complete all as specified and directed. |
| 52 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortat (1:3) using water proofing compound @ 3% by weight of cement finished even and fair as in sunken floor and wall complete all as specified and directed. |
| 53 | M&L for applying two coats of water proofing coating by using Super Latex manufacured by pidilite industries Ltd or equivalent product manufactured by Sika / Fosroc / Choksey mixed in chemical water and cement ratio as per manufacturer's instructions both on floor as well as on walls of sunken complete all as specified and directed. |
| 54 | M &L for cement concrete type E-2 1:5:10 (using 40mm graded crushed stone aggregate) as in mass filling in sunken floor of toilets and similar work complete all as specified and directed. |
| 55 | Cutting / drilling hole in brick wall / RCC beam or slab exc 300mm deep of WC/bath by mechanical mean and fixing with and including 40mm GI pipe as spouts pipe of require length at site, complete all as specified and directed. |
| 56 | M&L for joint free (edge cut) coloured glazed ceramic tiles 7 mm to 8 mm thick (square / rectangular) polished of size 350 x 250 x 7 mm / 450 x 350 x 7mm as in skirting / dado etc laid over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed. |
| 57 | M&L for non skid, joint free (edge cut) coloured ceramic tiles 7 to 8 mm thick (Square / rectangular) polished area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and directed. |
| 58 | Taking up or down 15 mm bore steel tubing and connections complete all as specified and directed. |
| 59 | Taking up or down 20 mm bore steel tubing and connections complete all as specified and directed. |
| 60 | Supplying and laying of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings such as bends, tee, union etc and connecting to water supply pipe line complete all as specified and directed. |
| 61 | Supplying and laying of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including necessary fittings such as bends, tee, union etc and connecting to water supply pipe line complete all as specified and directed. |
| 62 | S&F in repair 15 mm size bib taps cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for CPVC pipes complete all as specified and directed. |
| 63 | S&F in repair pillar taps cast copper alloy, chromium plated, screwed down high pressure with with long screwed shanks and fly nuts, screwed for CPVC pipe complete all as specified and directed. |
| 64 | S&F in repair 15 mm size angular / stop cock, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed both end for CPVC pipes complete all as specified and directed. |
| 65 | S & F in repairs gun metal gate valve, with iron wheel head screwed both ends for 20 mm bore pipe complete all as specified and directed. |
| 66 | S & F in repairs gun metal gate valve, with iron wheel head screwed both ends for 25 mm bore pipe complete all as specified and directed. |
| 67 | Taking down CI/rain water pipes/PVC pipes (any size or pattern) including all fittings, heads, shoes, bends, swan necks, etc., including cleaning etc complete all as specified and directed. |
| 68 | S&F PVC (SWR) pipes 75 mm dia single socketed, in any length, jointed with solvent cement, fixed on walls or floors with clamp complete all as specified and directed. |
| 69 | S&F PVC (SWR) pipes 110 mm dia single socketed, in any length, jointed with solvent cement, fixed on walls or floors with clamp complete all as specified and directed. |
| 70 | S&F PVC (SWR) bends of 75 mm bore of any radius complete all as specified and directed. |
| 71 | S&F PVC (SWR) bends of 110mm bore of any redius complete all as specified and directed. |
| 72 | S&F PVC (SWR) cowl of 75 mm bore of any radius complete all as specified and directed. |
| 73 | S&F PVC (SWR) cowl of 110mm bore of any redius complete all as specified and directed. |
| 74 | S & F PVC (SWR) branch piece single (single Y) equal or unequal 75 mm bore fixed complete all as specified and directed. |
| 75 | S & F PVC (SWR) branch piece single (single Y) equal or unequal 110mm bore fixed complete all as specified and directed. |
| 76 | S &F PVC (SWR) branch piece, double (double Y) equal or unequal 75 mm bore fixed complete all as specified and directed. |
| 77 | S &F PVC (SWR) branch piece, double (double Y) equal or unequal 110mm bore fixed complete all as specified and directed. |
| 78 | S&F in repair PVC (SWR) floor trap/Nahani trap, plain with grating including jointing with solvent cement, outlet dia 75 mm, including jointing to waste pipe fixed in cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specified and directed. |
| 79 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, plain with grating including jointing with solvent cement, including jointing to waste pipe fixed in cement concrete 1:2:4, type B 1 (using 20 mm graded stone aggregate) complete all as specified and directed. |
| 80 | S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, with plastic water closet seat, white, closed pattern with flat bottom, and cover with aluminised hinging device, including all connections complete all as specified and directed. |
| 81 | S&F in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580 mm x 440 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and directed. |
| 82 | Supply and fix in repair white vitreous China wash hand basin (flat back) of size 550 x 400 mm fixed on and including new brackets complete including screwed for iron pipe, 32 mm size brass chromium plated waste coupling, 750 mm long PVC waste pipe, etc complete all as specified and directed. |
| 83 | Cleaning and removing all scale and dirt etc capacity exc 250 & n exc 500 ltrs from tanks and from mouths of circulating pipes, etc complete all as specified and directed. |
| 84 | Cleaning and removing all scale and dirt etc capacity exc 500 & n exc 1000 ltrs from tanks and from mouths of circulating pipes, etc complete all as specified and directed. |
| 85 | S&F in repair water storage tank covers of any size at any height complete all as specified and directed |
| 86 | S & F in repair 10 Ltr capacity PVC valveless, syphonic action type, flushing cistern low level white with inlet ball valve float and handle including bracket, 32 mm dia pvc flushing pipe complete all as specified and directed. |
| 87 | S& F in repairs brass chromium plated overhead shower 100 mm size with 225 mm arm and flange for 15mm inlet pipe complete all as specified and directed. |
| 88 | S&F in repair health faucet (ABS Body) mild steelchromium plated suitable for 15 mm dia pipe with 125 cm long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 89 | S&F in repair 15mm cold and hot wall mixer brass chromium plated with bend pipe including all accessories complete all as specified and directed. |
| 90 | S& F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 91 | S& F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 92 | S& F in repairs stainless steel grating with or without hole of size 150mm x 150mm fixed with cement complete all as specified and directed. |
| 93 | S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. |
| 94 | S&F in repair 32mm dia waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms) complete all as specified and directed. |
| 95 | S&F in repair 40mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed. |
| 96 | Dismantling water tank of capacity exc 250 and not exc 500 ltrs complete all as specified and directed. |
| 97 | Dismantling water tank of capacity exc 500 and not exc 1000 ltrs complete all as specified and directed. |
| 98 | Supply and fix 500 ltr capacity tripple layer, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fittings such as connection pieces with tank nipple for inlet, outlet and over flow etc complete all as specified and directed. |
| 99 | Supply and fix 1000 ltr capacity tripple layer, Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fittings such as connection pieces with tank nipple for inlet, outlet and over flow etc complete all as specified and directed. |
| 100 | Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point, socket point or power point including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing material for taking credit and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces with distemper/white washing/colour washing as per existing complete all as specified and directed. |
| 101 | Point wiring with PVC insulated and unsheathed multi stranded FRLS copper conductor single core 1.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping/ in conduit with all accessories suitable for modular type fitment including joint boxes, terminal boxes etc complete along with copper earth wire PVC insulated & unsheathed multi stranded (FRLS) copper conductor cable of size 1.5sqmm as continuous earth wire connected to common earth and earth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.Note: Modular metal boxes will be measured & paid seperately. |
| 102 | One Light point /Fan point controlled by one switch |
| 103 | One 3 pin socket outlet 5Amps on the same board with other switches |
| 104 | One 3 pin 5 Amp socket out let controlled by one switch on independent board |
| 105 | One bell /Buzzer point controlled by one bell push 5 amp on the same board with other switches or independent |
| 106 | One light point controlled by two 2-way switch with cable 1.5 sqmm |
| 107 | Point wiring for power point with PVC insulated and unsheathed multi stranded FRLS copper conductor single core 2.5sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping/conduit with all accessories suitable for modular type fitment including joint boxes, terminal boxes etc complete alongwith copper earth wire PVC insulated & unsheathed multi stranded(FRLS) copper conductor cable of size 2.5 sqmm as continuous earth wire connected to common earth and erth dolly complete all as specified and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.Note : Modular metal flush boxes will be measured & paid seperately. |
| 108 | All as per item No 8 above but wiring with 4.0 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 4.0Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as continuous earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. |
| 109 | S & F in repair Switch piano flush type single pole, one way 5 Amp 230 V complete all as specified and directed. |
| 110 | S & F in repair socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed. |
| 111 | S & F in repair switch piano flush type single pole, one way 15 Amp complete all as specified and directed. |
| 112 | S & F in repair socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type complete all as specified and directed. |
| 113 | S & F in repairs switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed. |
| 114 | Supply and fix in repair modular switch socket Combination 16A, 6 pin, 3 module complete all as specified and directed. |
| 115 | Supply and fix in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and as directed. |
| 116 | S & F in repair ceiling rose 2 to 3 terminal PVC / polycarbonate, isolated body type suitable for AC 230 volts complete all as specified and directed. |
| 117 | S & F in repair switch piano type 2 way 5 amp 230 volts complete all as specified and directed. |
| 118 | S & F in repair bell push 5 Amp 230 volts complete all as specified and directed. |
| 119 | S & F in repair bell AC 230 Volts, single pole complete all as specified and directed. |
| 120 | M & L for module cover plate with frame as per site requirement for following module:- |
| 121 | 1 module |
| 122 | 2 module |
| 123 | 3 module |
| 124 | 4 module |
| 125 | 6 module |
| 126 | 8 module |
| 127 | M & L for modular metal flush box as per site requirement. |
| 128 | 1/2 module |
| 129 | 3 module |
| 130 | 4 module |
| 131 | 6/8 module |
| 132 | S&F in repair modular switch 1 way 6 Amp 1 Module complete all as specified and directed. Make :- Legrand Arteor series Cat Part No :-573400 or equivalent make as mentioned in Appx 'B' to PS. |
| 133 | S&F in repair Modular Switch 1 way 16/20 Amp 1 Module complete all as specified and directed. Make :- Legrand Arteor series Cat Part No :-573410 or equivalent make as mentioned in Appx 'B' to PS. |
| 134 | S&F in repair Modular Socket 6A 2/3 Pin universal 2 module complete all as specified and directed. Make : Legrand Arteor series Cat Part No : 573470 or equivalent make as mentioned in Appx 'B' to PS. |
| 135 | S&F in repair modular socket 16A/ 6A 2/3 Pin combined 2 module complete all as specified and directed. Make :- Legrand Arteor series Cat Part No :-573471 or equivalent make as mentioned in Appx 'B' to PS. |
| 136 | S&F in repair modular fan step regulator 100 watt 2 module complete all as specified and directed. Make :- Legrand Arteor series Cat Part No :-573416 or equivalent make as mentioned in Appx 'B' to PS. |
| 137 | S&F in repair Modular Bell push 6A 1 way, 1 Module complete all as specified and directed. Make :- Legrand Arteor series Cat Part No :-573413 or equivalent make as mentioned in Appx 'B' to PS. |
| 138 | S&F in repair energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 20 watt, channel housing & diffuser of length 1200 mm (approx.) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed. |
| 139 | S&F in repair energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 10 watt, channel housing & diffuser of length 600 mm (approx.) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed. |
| 140 | Taking down carefully (copper/aluminum) sub main wiring complete of any type (batten/surface conduit or concealed) for socket point or power point complete with all fittings such as switches sockets pendants etc complete and making good disturbed surface of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surface with distemper white washing/co0lour washing to match with the existing surface complete all as specified and directed. |
| 141 | M&L for sub main wiring using PVC insulated and unsheathed multi stranded FRLS copper conductor cable using approved colour code as per IS drawing in and incl PVC casing and capping of suitable size with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete as specified and as directed of the following sizes of cables:- |
| 142 | Using two single core PVC insulated FRLS cable 4 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 4sqmm copper cable & 1 run of 4 sqmm copper cable and one run of casing & caping shall be measured as one unit |
| 143 | Using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire Note :2runs of 6sqmm copper cable & 1 run of 6.0 sqmm copper cable and one run of casing & caping shall be measured as one unit |
| 144 | Using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable and one run of casing & caping shall be measured as one unit |
| 145 | M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for IP 43 & IP 54, single pole and neutral 250 Volts, flush to wall complete with IP 54 protection complete with taking down old UNSV DB and making good to existing surface all as specified and directed. Make : Legrand Model: IP 54 IK 09 507641 Ekinox or equivalent make as mentioned in Appx 'B' to PS. |
| 146 | S&F in repair MCB single pole & neutral 240 volt C curve 10 KA (32 to 63) Amps capacity IP 20 complete all as specified and directed. |
| 147 | S&F in repair MCB single pole,5 to 30 Amp 240 volt B curve 10 KA, IP 20 complete all as specified and directed. |
| 148 | S&F in repair MCB triple pole,63 Amp 240 volt B curve 25 KA, IP 20 complete all as specified and directed. |
| 149 | Supply only bulb of 10-12 W energy efficient operating voltage 100-300 volts complete all as specified and directed. |
| 150 | M & L for distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4way with 100 Amps rated copper busbar, neutral bar, earth bar and cable ties for cable management, reversible door for IP 43 & IP 54, single pole and neutral 250 Volts, flush to wall complete with IP 54 protection complete with taking down old UNSV DB and making good to existing surface all as specified and directed. |
| 151 | Taking down carefully ceiling fan / exhaust fan / cabin fan / wall mounted fan by disconnecting electric connection for carrying out repairing such as rewinding, replacement of defective spare part, over hauling and painting etc as required and re-fixing in the same position after carry out the repairs works, and connecting complete all as specified and directed.Note:- Repairing such as rewinding, replacement of defective spare part, connecting wire, Over hauling and painting etc will be measured & paid separately under subsequent items. |
| 152 | M & L for rewinding of ceiling fan of size 1200mm sweep of any make by dismantling the ceiling fan, removing shaft ,bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing and reassembling. Providing three core copper cable PVC insulated multi stranded 0.5mm 30cm length for connection of fan from ceiling rose and testing of fan complete all as directed. Rewinding should be carried out for the following size of ceiling fan:- |
| 153 | M & L for rewinding of exhaust fan motor of any make by dismantling the exhaust fan, removing shaft, bearing and bushing, removing the burnt copper winding from the slots, cleaning slot, replacement of defective nut bolts washer etc and rewinding of fan motor using appropriate gauge/size super enameled copper winding wire thermal class-E, including varnishing ,applying cotton tape and reassembling complete. Providing twin core copper cable 30cm length for connection and testing of fan complete all as specified and directed. Rewinding should be carried out for the following size of exhaust fan:- |
| 154 | 300mm sweep |
| 155 | 220/200mm sweep |
| 156 | Supply and fix in repair ball bearing of any size suitable for ceiling fan 1200 mm sweep complete all as specified and directed. |
| 157 | Supply and fix in repair Gun metal bush of any size suitable for ceiling fan of 1200 mm / 1400 mm sweep complete all as specified and directed. |
| 158 | Supply and fix in repair Gun metal bush of any size suitable for exhaust fan 300 / 200 mm sweep complete all as specified and directed. |
| 159 | Supply and fix in repair capacitor 2.5 MFD AC 230 Volt 50 HZ, for ceiling fans complete all as specified and directed. |
| 160 | Supply and fix in repair capacitor 4 MFD AC 230 Volt 50 HZ, of exhaust / bracket fan any size complete all as specified and directed. |
| 161 | Supply and fix in repair bolt, nuts, washer and split pin for the down rod of ceiling fan complete all as specified and directed. |
| 162 | M&L for servicing of geyser electric water heater & storage type any capacity at site including taking down from existing place, checking of thermostat, heating element, opening up and cleaning of the same after replacement of the unserviceable spare parts such as thermostat nut and bolt etc and hanging the same in position and connecting complete all as specified and directed.Note:- Spare parts shall be measured and paid separately under relevant items as supply only. |
| 163 | M&L for Indicator lamp (red, green) including necessary connection in geyser capacity of 25/50 Ltrs complete all as specified and directed. Note:- Rate quoted by tenderer is for each neon lamp. |
| 164 | Thermostat of water heater for 25/50 Ltrs capacity AC 230V. |
| 165 | Water heater heating element for 25/50 Ltrs capacity 1.5 KW. |
| 166 | Supply and fix stainless steel inner tank for 25/50 ltrs capacity |
| 167 | M&L flexible pipe of length not less than 60 cm with washer for hot and cold water for geyser connection. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail