| 1 | Supply, laying, testing & commissioing of 10 Sqmm 2 core size XLPE insulated, PVC sheathed, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 Part I marked, suitable for LT 1100 Volt system,laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe including jointing & testing and taking down old U/S cable complete all as specified and as directedNote :- Excavation, earth work ,cable protection , sand fillings shall be measured and paid separately under respective items of schedule. |
| 2 | All as per Ser No 1 above but size 10 sqmm 4 core |
| 3 | All as per Ser No 1 above but size 16 sqmm 4 core |
| 4 | All as per Ser No 1 above but size 25 sqmm 4 core |
| 5 | All as per Ser No 1 above but size 35 sqmm 3.5 core |
| 6 | All as per Ser No 1 above but size 50 sqmm 3.5 core |
| 7 | All as per Ser No 1 above but size 70 sqmm 3.5 core |
| 8 | All as per Ser No 1 above but size 120 sqmm 3.5 core |
| 9 | All as per Ser No 1 above but size 150 sqmm 3.5 core |
| 10 | Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole as a foundation or in any situation complete all as specified. |
| 11 | Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole by demolition of existing /broken coping or in any situation complete all as specified. |
| 12 | Excavation in trenches in soft/ loose soil n.exc 1.5mtr wide and not exc 1.5mtr in depth and getting out complete all as specified. |
| 13 | All as per item No 12 here in before but exc 1.5 mtr in depth complete all as specified. |
| 14 | M&L for tibba sand locally available sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed. |
| 15 | M&L for laying jodhpur stone quarry stone slab cover 25 to 30cm in width, 60cm long and 40 to 50 mm thick laid in trenches and abutting each other with gap between adjacent slab not exceeding 10mm over sand covered under ground cables complete all as specified. |
| 16 | Returning, filling, in including spreading, leveling , watering and well ramming in layers n.exc 25 cm in soil complete all as specified. |
| 17 | Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified. |
| 18 | Supply and fixing in replacement GI Pipe light grade 80 mm dia with necessary accessories/ fittings bracing with pole/wall by FI clamps for cable protections/pole for crossing of culverts/nallah and all as specified and directed sizes:- |
| 19 | All as per ser item No 18 above but of size 50 mm dia |
| 20 | All as per ser item No 18 above but of size 40 mm dia |
| 21 | M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified. |
| 22 | Arranging fault locating machine to locate the fault in underground elect power cables of any length and any type of 1100 Volts grade LT cable and pin point the fault and testing of the cable after locating fault and cutting the cable at fault to check healthiness of cable before and after including excavation and earth work in any type of soil complete all as specified. |
| 23 | Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 16- 35 Sqmm x 3.5 core/4 core complete all as specified. |
| 24 | All as per ser item No 23 above but of size 50-70 Sqmm x 3.5 core |
| 25 | All as per ser item No 23 above but of size 95-120 Sqmm x 3.5 core |
| 26 | All as per ser item No 23 above but of size 150-185 Sqmm x 3.5 core |
| 27 | All as per ser item No 23 above but of size 240-300 Sqmm x 3.5 core |
| 28 | Supply, fixing and testing end joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade 10-35 Sqmm x 3.5 core complete all as specified. |
| 29 | All as per ser item No 28 above but of size 50-70 Sqmm x 3.5 core |
| 30 | All as per ser item No 28 above but of size 95-120 Sqmm x 3.5 core |
| 31 | All as per ser item No 28 above but of size 150-185 Sqmm x 3.5 core |
| 32 | All as per ser item No 28 above but of size 240-400 Sqmm x 3.5 core |
| 33 | Material and labour for disconnecting power supply from LT ACB of cap. 800/1000/1500 Amps for repair works , taking out trolly unit & complete servicing of the same through decarbonising , cleaning the male /female isolating contacts, lubricating moving part , cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, tightening all nuts and bolts of entire trolley, checking proper operation of trolly all as directed, inserting trolley inside and testing and putting on load complete all as specified. |
| 34 | Supply and fixing in replacement of manual on load change over switch 4 pole, 415 Volts 50 Hz 100 Amps with sheet steel enclosure mounted on wall or fixing in existing panel with all fixing arrangement complete all as specified. |
| 35 | All item as per Ser No 34 above but of 160 Amps Capacity |
| 36 | All item as per Ser No 34 above but of 250 Amps Capacity |
| 37 | All item as per Ser No 34 above but of 400 Amps Capacity |
| 38 | S&F in replacement of MCCB,4 pole 100 Amp 16 KA , suitable for 415 volts, 50HZ 3 Phase, with adjustable Thermal & fixed magnetic,, over load and short circuit setting on LT panel/feeder pillar complete all as specified. |
| 39 | All as per ser item No 38 above but of capacity 125 Amps,4pole 415 volts 25 KA |
| 40 | All as per ser item No 38 above but of capacity 160 Amps,4pole 415 volts 36KA |
| 41 | All as per ser item No 38 above but of capacity 200 Amps,4pole 415 volts 36KA |
| 42 | All as per ser item No 38 above but of capacity 250 Amps,4pole 415 volts 36KA |
| 43 | All as per ser item No 38 above but of capacity 315 Amps,4pole 415 volts 36KA |
| 44 | All as per ser item No 38 above but of capacity 400 Amps,4pole 415 volts 36KA |
| 45 | All as per ser item No 38 above but of capacity 630 Amps,4pole 415 volts 50KA Please Enable Macros to View BoQ information |
| 46 | All as per ser item No 38 above but of capacity 630 Amps,4pole 415 volts 50KA Please Enable Macros to View BoQ information |