| 1 | Excavation in trenches for laying of GI water tubing etc., getting out in soft/loose soil n.exc 1.5m wide and n.exc 1.5m depth complete all as specified and directed. |
| 2 | Returning, filling in trenches including spreading, leveling, watering and in layers n.exc 25cms thick without damaging pipes/special fittings as in any type of soil complete all as specified and directed. |
| 3 | Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 4 | M & L for every six month Bacteriological/ Chemical water testing analysis reports main pump houses including RO plant. Sample shall be collected by contractor from all sources and testing will be done at Jal Kal Vibhag Nagar Nigam at Govt laboratory and report to be submitted to this office in duplicate copy complete all as specifieds and directed by engineer-in-Charge. |
| 5 | M&L for centrifugally cast (spun) ductile iron pressure pipes 150 mm bore for water with socket & spigot ends confirming to IS 8329/2000 in any length for classification of K7 suitable for rubber gasket push on with cement mortar lining inside the pipe with outside zinc coating as per IS 8329/2000 including taking down old unsv pipes complete all as specified and as directed. |
| 6 | M&L for centrifugally cast (spun) ductile iron pressure pipes 100 mm bore for water with socket & spigot ends confirming to IS 8329/2000 in any length for classification of K suitable for rubber gasket push on with cement mortar lining inside the pipe with outside zinc coating as per IS 8329/2000 including taking down old unsv pipes complete all as specified and as directed. |
| 7 | M&L for cast iron pipe spigot and socketed pipes centrifugally cast class LA in any length laid in trenches including taking down old unserviceable CI pipe complete all as specified and as directed. |
| 8 | All as per Item No 7.00 above but 80 mm dia complete all as specified & directed. |
| 9 | All as per Item No 7.00 above but 100 mm dia complete all as specified & directed. |
| 10 | All as per Item No 7.00 above but 150 mm dia complete all as specified & directed. |
| 11 | Supply and laying in trenches steel water tubing galvanised medium grade and connection including fitting like Tee, Bend, Socket, Elbow, Short pieces connectors, plugs, and unions etc, cutting threading the following sizes all as specified and directed. |
| 12 | All as per Item No 11.00 above but 100 mm dia complete all as specified & directed. |
| 13 | All as per Item No 11.00 above but 80 mm dia complete all as specified & directed. |
| 14 | All as per Item No 11.00 above but 50 mm dia complete all as specified & directed. |
| 15 | All as per Item No 11.00 above but 40 mm dia complete all as specified & directed. |
| 16 | All as per Item No 11.00 above but 25 mm dia complete all as specified & directed. |
| 17 | All as per Item No 11.00 above but 20 mm dia complete all as specified & directed. |
| 18 | Taking down old unserviceable GI pipe and complete all as specified for the following sizes :- |
| 19 | All as per Item No 18.00 above but 100 mm dia complete all as specified & directed. |
| 20 | All as per Item No 18.00 above but 80 mm dia complete all as specified & directed. |
| 21 | All as per Item No 18.00 above but 50 mm dia complete all as specified & directed. |
| 22 | All as per Item No 18.00 above but 40 mm dia complete all as specified & directed. |
| 23 | All as per Item No 18.00 above but 25 mm dia complete all as specified & directed. |
| 24 | All as per Item No 18.00 above but 20 mm dia complete all as specified & directed. |
| 25 | Repair of CI pipe line including excavation for, taking out Joint, burning out/ removing lead joint and refixing pipe/ fitting in original postion realignment to existing CI collars at both ends, testing of leakage and complete of the following size of pipe as specified and directed.NOTE: (i) Cast iron pipe shall be measured and paid separately under relevent items. (ii) Cost of excavation will deemed to be included in the quoted unit rate. |
| 26 | All as per Item No 25.00 above but 80 mm dia complete all as specified & directed. |
| 27 | All as per Item No 25.00 above but 100 mm dia complete all as specified & directed. |
| 28 | All as per Item No 25.00 above but 150 mm dia complete all as specified & directed. |
| 29 | Material and labour for PCC 1:3:6, type C2 using 20mm graded stone aggregate for making good disturbed surfaces road /pavments/ foot paths etc., complete all as specified and directed . |
| 30 | Material and labour for construction of block masonary valve pit complete with PCC 1:3:6 type C1 solid block walling 20cm thick set in CM (1:4) over 100 mm thick PCC 1:4:8 type D2 foundation, 50 mm thick PCC 1:2:4 type B1 coping on the top of wall, rendering 15 mm thick with CM 1:4 on inside and exposed external surfaces up to 150mm below GL, 3 mm thick MS sheet cover, angle iron frame with locking arrangment etc., including dismantling old existing damaged valve pit complete of following sizes all as specified and directed:- |
| 31 | All as per Item No 30.00 above but 0.75m x 0.75m x 0.75m complete all as specified & directed. |
| 32 | All as per Item No 30.00 above but 1.2m x 1.2m x 1.2m complete all as specified & directed. |
| 33 | All as per Item No 30.00 above but 1.5m x 1.5m x 1.5m complete all as specified & directed. |
| 34 | All as per Item No 30.00 above but 2.0m x 2.0m x 2.0m complete all as specified & directed. |
| 35 | Supply and fix for gun metal gate valve (ISI) marked with iron wheel head screwed both ends for iron pipe suitable for following bore of pipe including taking down old existing gate valve complete all as speficied and directed. |
| 36 | All as per Item No 35.00 above but 50 mm bore pipe complete all as specified & directed. |
| 37 | All as per Item No 35.00 above but 40 mm bore pipe complete all as specified & directed. |
| 38 | All as per Item No 35.00 above but 25 mm bore pipe complete all as specified & directed. |
| 39 | All as per Item No 35.00 above but 20 mm bore pipe complete all as specified & directed. |
| 40 | All as per Item No 35.00 above but 15 mm bore pipe complete all as specified & directed. |
| 41 | Taking down old defective non return valve supply and fix non return valve with by pass arrangement working pressure 10 kg per sq cm confirming to IS- 5312 including jointing by means of rubber gasket 3mm thick, MS nut bolt, washers, packing material etc., including testing for following sizes:- |
| 42 | All as per Item No 41.00 above but 150mm dia complete all as specified & directed. |
| 43 | All as per Item No 41.00 above but 100mm dia complete all as specified & directed. |
| 44 | Supply and fixing in repairs of the Three phase submersible pump controllers/ Starter with ML contactor & MN5 relay type MU G-40 FASD fully automatic suitable for 35HP submersible motor, 415V, 50Hz, 3Ph relay range 36-60 Amp, indication offered - ON/ OFF, with voltage and Amp meter complete all specified and as directed. Make: L&T cat part No-CS90908LOTO |
| 45 | Material and labour for disconnecting /removing the old unserviceable starters parts from the panel and supply and fixing faulty contactor with relay for fully automatic star delta starters for AC 415v, 50Hz, 3-phase suitable for 30HP upto 40HP capacity electric motor complete all as specified and directed. |
| 46 | Material and labour Ductile iron/ CI fitting suitable for K9/ K7 such as spigot and socket pipe/ flanged Specials of any dia including taking down of unservicable / damaged specials as required at site all as specified and directed. |
| 47 | Taking down old unserviceable sluice valves and supply and fix new Sluice valve CI body double flanged and drilled conforming to IS-780 of 1980 PN-1.6 including rubber gasket 3 mm thick, stainless steel spindle, iron wheel head and suitable size of nuts bolts and washers complete all as specified for the following sizes. |
| 48 | All as per Item No 47.00 above but Sluice valves 150 mm dia complete all as specified & directed. |
| 49 | All as per Item No 47.00 above but Sluice valves 100 mm dia complete all as specified & directed. |
| 50 | All as per Item No 47.00 above but Sluice valves 80 mm dia complete all as specified & directed. |
| 51 | Repairs to CI sluice valves by taking down worn out unserviceable gland sleeve, check nut spindle, gate etc., and cleaning the valve by removing all scales and reassembling the valve with new packing, nut and bolts complete all as specified and directed for the following diametre:- |
| 52 | All as per Item No 51.00 above but 150mm dia complete all as specified & directed. |
| 53 | All as per Item No 51.00 above but 100mm dia complete all as specified & directed. |
| 54 | All as per Item No 51.00 above but 80mm dia complete all as specified & directed. |
| 55 | Material and labour for purichloro (65 - 70%) calcium based granular disinfected for water treatment more stable than chlorine gas and stronger than bleaching powder and sodium hypochlorite in 45 kg Drum complete all specified and as directed. |
| 56 | Excavating bituminous road appx 1.2 m wide and n.exc 1.5m depth to complete the work at the earliest on highways and main roads for laying/ repair pipes, retuning fillingin and finishing the top surface after laying/repair of pipe work with PCC (1:2:4) type B2 to a minimum depth of 300mm over dry mix concrete (1:4:8) type D2 to a minimum depth of 600mm over rammed earth to suit the site requirement and making good the disturbed surface to match with existing finish complete all as specified and directed. Please Enable Macros to View BoQ information |
| 57 | Excavating bituminous road appx 1.2 m wide and n.exc 1.5m depth to complete the work at the earliest on highways and main roads for laying/ repair pipes, retuning fillingin and finishing the top surface after laying/repair of pipe work with PCC (1:2:4) type B2 to a minimum depth of 300mm over dry mix concrete (1:4:8) type D2 to a minimum depth of 600mm over rammed earth to suit the site requirement and making good the disturbed surface to match with existing finish complete all as specified and directed. Please Enable Macros to View BoQ information |