| 1 | Supply and fix in replacement of MCCB, 415V, 3/4 pole fixed type or adjustable thermal setting 16KA, 63 Amps, with suitable existing make and model complete all as specified and as directed. |
| 2 | Supply and fix in replacement of MCCB, 415V, 3/4 pole fixed type or adjustable thermal setting 16KA, 100 Amps, with suitable existing make and model complete all as specified and as directed. |
| 3 | Supply and fix in replacement of MCCB, 415V, 3/4 pole fixed type or adjustable thermal setting 16KA, 125 Amps, with suitable existing make and model complete all as specified and as directed. |
| 4 | Supply and fix in replacement of MCCB, 415V, 3/4 pole, adjustable thermal setting type 36KA, 160 Amps, with suitable existing make and model complete all as specified and as directed. |
| 5 | Supply and fix in replacement of MCCB, 415V, 3/4 pole, adjustable thermal setting type 36KA, 200 Amps, with suitable existing make and model complete all as specified and as directed. |
| 6 | Supply and fix in replacement of MCCB, 415V, 3/4 pole, adjustable thermal setting type 36KA, 250 Amps, with suitable existing make and model complete all as specified and as directed. |
| 7 | Supply and fix in replacement of MCCB, 415V, 3/4 pole, adjustable thermal setting type 36KA, 315/350 Amps, with suitable existing make and model complete all as specified and as directed. |
| 8 | Supply and fix in replacement of MCCB, 415V, 3/4 pole, adjustable thermal setting type 50KA, 400 Amps, with suitable existing make and model complete all as specified and as directed. |
| 9 | Supply and fix in replacement of MCCB, 415V, 3/4 pole, adjustable thermal setting type 50KA, 600-650 Amps, with suitable existing make and model complete all as specified and as directed. |
| 10 | Supply and jointing in replacement of straight through joint, epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes up to 16 Sqmm 3.5/4 core, 1100 volts grade with jointing kit complete all as specified and as directed. |
| 11 | Supply and jointing in replacement of straight through joint, epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 25 Sqmm 3.5/4 core to 50 Sq mm x 3.5 core, 1100 volts grade with jointing kit complete all as specified and as directed. |
| 12 | Supply and jointing in replacement of straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 70 Sqmm x 3.5 core to 120 Sq mm x 3.5 core, 1100 volts grade with jointing kit complete all as specified and as directed. |
| 13 | Supply and jointing in replacement of Straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of sizes from 150 Sqmm x 3.5 core to 185 Sq mm x 3.5 core, 1100 volts grade with jointing kit complete all as specified and as directed. |
| 14 | Supply and jointing in replacement of straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of size 240 sqmm x 3.5 core to 300 sqmm x 3.5 core, 1100 volts grade with jointing kit complete all as specified and as directed. |
| 15 | Supply and jointing in replacement of straight through joint epoxy type for LT cable PVC/XLPE insulated armoured aluminium conductor of size 400 sqmm x 3.5 core to 500 sqmm x 3.5 core, 1100 volts grade with jointing kit complete all as specified and as directed. |
| 16 | Supplying and laying in GI tubing light grade for cable protection in trenches/ duct/ fixing to pole/ wall or in such similar position including taking down existing unserviceable pipe for the following sizes complete all as specified and as directed. |
| 17 | 80 mm dia |
| 18 | 50 mm dia |
| 19 | 40 mm dia |
| 20 | Supply and laying UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100V grade cross sectional for the following sizes laid in trenches /ducts/ fixed to wall/ pole/ inside panel/ drawn through pipe along with cable glands and terminal sockets, including taking down existing unserviceable cable etc complete all as specified and as directed. |
| 21 | 10 Sqmm 2 core |
| 22 | 10 Sqmm 4 core |
| 23 | 16 Sqmm 4 core |
| 24 | 25 Sqmm 3.5 core |
| 25 | 35 Sqmm 3.5 core |
| 26 | 50 Sqmm 3.5 core |
| 27 | 70 Sqmm 3.5 core |
| 28 | 95 Sqmm 3.5 core |
| 29 | 120 Sqmm 3.5 core |
| 30 | 150 Sqmm 3.5 core |
| 31 | 185 Sqmm 3.5 core |
| 32 | 240 Sqmm 3.5 core |
| 33 | 300 Sqmm 3.5 core |
| 34 | 400 Sqmm 3.5 core |
| 35 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth and getting out in soft/loose soil including forming of bottom for laying cable complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Excavation in trenches not exceeding 1.50m wide and exceeding 1.50m not exceeding 3.00m in depth and getting out in soft/loose soil including for laying cable complete all as specified and as directed by Engineer-in-Charge |
| 37 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/dense soil including forming of bottom for laying cable complete all as specified and as directed by Engineer-in-Charge |
| 38 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 39 | Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 40 | Removing excavated material not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point complete all as specified and as directed. Please Enable Macros to View BoQ information |