| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and directed. |
| 2 | Hardcore of broken boulders/stones of guage exc 63mm but n exc. 100mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface,complete all as specified and directed. |
| 3 | 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base for floors, paving etc, finished even and rough complete all as specified and directed. |
| 4 | Machine pressed Concrete interlocking paver block, any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 Grade with gray cement and pigment complete all as specified and directed |
| 5 | Sand filling under floors or in foundations including watering and consolidation , all as specified. |
| 6 | Plain cement concrete type C-1 (1:3:6) using 20mm graded crushed stone aggregate as in seismic and other similar bands, shelves, copings, bed plates, hold fast, plinth courses and the like finished fair & even, including necessary formwork complete all as specified. |
| 7 | Excavating in post holes(or similar holes) each n exc 0.5 cum, getting out, returning, filling in any type of soil complete all as specified and directed. |
| 8 | Providing cement concrete 1:2:4 type B-2 (40mm graded aggregate) as in foundations filling and mass concrete complete all as specified and directed. |
| 9 | Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade ST-240. |
| 10 | Two coats of synthetic enameled paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. |
| 11 | Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 12 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge. |
| 13 | providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate, as in foundations, filling and mass concrete etc., complete all as specified and as directed |
| 14 | Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. |
| 15 | Reinforced cement concrete (M-25 design mix, using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, balconies, roofs, canopies shelves and the like complete all as specified and directed (reinforcement shall be measured and paid for separately). |
| 16 | Form work to soffits of suspended slabs such as roof slabs rough finished surface of concrete flat not exc 200mm thick complete all as specified and directed. |
| 17 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm complete all as specified and directed. |
| 18 | Rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:4 surface finished even and smooth without using extra cement compelte all as specified and directed. |
| 19 | 100mm thick cement concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) as in flooring, finished even and smooth without using extra cement complete all as specified and directed. |
| 20 | 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. |
| 21 | Plain cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in surface channel and drain complete all as specified & directed. |
| 22 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed |
| 23 | Machine cut Kota Stone Slab 20-25mm thick over cement screed bed laid and jointed with grey cement slurry and pointed with grey cement mixed with pigment to match the shade of the slab including rubbing and ploshing complete over and including 15mm thick screed bed in CM 1:6 all as specified and directed. |
| 24 | Green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, complete all as specified and directed. |
| 25 | Brick work with sub class ‘B’ bricks straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed. |
| 26 | Rendering 15mm thick in Cement and Sand mortar 1:4 over fair faces of brick/concrete surfaces ,finished even and smooth without using extra cement, complete all as specified and directed. |
| 27 | Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 28 | Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 29 | Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 30 | Reinforced cement concrete type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span , all as specified and directed. |
| 31 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surface of flat concrete complete all as specified and directed. |
| 32 | Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. |
| 33 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter , all as specified and directed. |
| 34 | Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified & directed. (Stirrups) |
| 35 | Supply only integral water proofing compound (ISI Marked) complete all as specified & directed. |
| 36 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. |
| 37 | Removal of excavated material to distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point in soil, complete all as specified and directed. |
| 38 | 16 to 18mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite incl laid over incl 20mm thick screed bed in CM (1:4) in skirting/ dado all as specified & directed. |
| 39 | 10 to 15mm thick Industrial homogeneous vitrified heavy duty tile, of premium 1st quality of size n exc 0.36 sqm (any colour as approved by Engr-in-charge/GE) over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. (Make- Endura from Jhonson or Equivalent as specified inPS & approved by GE) |
| 40 | Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, of required size (as dircted by Engineer-in-Charge) channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wher ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with required accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of floor or the side of waist slab with suitable arrangement all as specified and directed. |
| 41 | Taking down cement plaster on brick/ stone walls etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed |
| 42 | Demolition of stone slabs and tiles of any description or thickness in floors laid, bedded and pointed in any mortar including disposal of demolished material complete all as specified and directed. |
| 43 | Demolition of brick work masonry, built in cement mortar including dismantling all quions, arches, pillars etc complete all as specified and directed. |
| 44 | Demolition of reinforced concrete such as roofs, flors, beams, staircase, landing, chaffas, facia and similar suspended work (reinforcement cut as required to facilitate demolition) |
| 45 | Wash hand basin, vitreous china, counter top (oval shape) wash basin white, size 550X400mm, excluding taps, waste chain plug and porcelain stopper including waste pipe, waste coupling brackets of suitable size, cutting for and pinning in ends of brackt or erecting stand complete all as specified and directed. |
| 46 | Wall mixer, mix for mixing hot and cold water, brass chromium plated suitable for 15mm bore GI pipe or union, complete all as specified and directed. |
| 47 | PVC (SWR) rain water pipe, 75mm bore, single socketed in any length with rubber ring joints having minimum density 6 Kg/cm2, fixed to floor/walls, fixed as in repair complete all as specified and directed. |
| 48 | 75 mm bore PVC (SWR) bends of any radius, fixed as in repair complete all as specified and directed. |
| 49 | PVC (SWR) floor trap 75mm bore, plain with grating including jointing to waste pipe jointed and setting/fixed in cement concrete type B-1, 1:2:4 , fixed as in repair complete all as specified and directed. |
| 50 | PVC (SWR) junction single, (Single T) equal or unequal for 75mm bore pipe, fixed as in repair complete all as specified and directed. |
| 51 | Rendering 10mm thick on fair faces of brick work surfaces, finished even and smooth in cement mortar (1:6), complete all as specified. |
| 52 | Rendering 10mm thick on fair faces of concrete surface of ceiling in CM 1:3, surface finished even and smooth without using extra cement. |
| 53 | Three coats of white wash on ceiling surfaces including preparation of new plastered surfaces complete all as specified and directed. |
| 54 | Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over and including coat of primer on the surfaces, complete all as specified and directed. |
| 55 | Glazed ceramic coloured printed tiles on vertica surfaces of size 300 x 450 x 7mm set and jointed in neat cement slurry over and including 10mm thick rendering in CM 1:4 for receiving the tiles complete all as specified. |
| 56 | Bib tap brass, fancy type, long body with wall flange, standard chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed as in repairs complete all as specified and directed. |
| 57 | Kitchen sink with drainage board made out of stainless steel sheet 1.0mm thick with plug, washers and wastes, overall size 915 x 460mm, bowl size 410x330x160mm incl fixing cantilever brackets and connection to union, pipe, fixed as in repair complete all as specified and directed. |
| 58 | Factory made 18mm thick solid WPC (Wood Polymer Composite) board of density 650 Kg /cum of one side prelaminated / rigidlam with any colour and other side balancing laminate as in cup board/ kitchen cabinet shutter/ drawer, front shuters, fixed with screws, solvent / adhesive, complete all as specified and directed. |
| 59 | Continuous (piano) hinges, mild steel bright finish, width of flap when open 30mm, complete all as specified and directed. |
| 60 | 150mm long aluminum handle cast type anodized , complete all as specified and directed. |
| 61 | 150mm aluminium anodized barrel tower bolts of extruded section complete all as specified and directed. |
| 62 | 20mm tubes, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors complete including taking out existing pipe complete all as specified and directed. |
| 63 | 15mm tubes, medium grade, galvanized, with and including all fittings and fixed complete to walls ceiling or laid in floors complete including taking out existing pipe complete all as specified and directed. |
| 64 | Cutting chases for concealed piping in brick/stone wall, cutting n.exc 10cm girth, pinning in making good to facing where required and pionting in cement mortar 1:3 complete all as specified and directed. |
| 65 | Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete all as specified and directed. |
| 66 | Supply only prelaminated particle board 7-8 mm thick of size 600 x 600mm, interior grade, preliaminated one side with decorative choice lamination and other side balancing white lamination, fixed with staples as in snap grid complete all as specified and directed. |
| 67 | Mortice lock, verticle type, mild steel, 4 levers, size 100mm, brass body, complete all as specified and directed |
| 68 | Door closer hydraulically regulated aluminum (die cast) body, designation No 3, universal type, suitable for door shutters of 701mm to 850mm in width and of weight between 36 to 60 Kg, fixed complete all as specified and directed. |
| 69 | D' type, 150mm Extruded aluminium alloy handle fabricated type complete all as specified and directed. Please Enable Macros to View BoQ information |