| 1 | Excavation in trenches, n.exc 1.5M wide and not exceeding 1.5M depth for foundation etc or for shaft, wells, cesspits, manhole, pier holes etc n. exc 10 sqm on plan and n. exc 1.5M in depth and getting out in soft/hard soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25cm thick complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Removing excavated material to a distance exc 50M but n. exc 150M and depositing where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed. |
| 4 | M&L for RCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings and pillars upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, with and including use and waste of form work complete all as specified and as directed. |
| 5 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quions/archers etc complete all as specified and as directed. |
| 6 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for keys, scrubbing down with water, etc complete all as specified and as directed. |
| 7 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6mtr mean radius built in CM (1:6) complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for cement concrete (1:4:8) type D2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for 15mm thick rendering of Ready mix plaster of approved make on brick/ concrete surfaces on external walls, fascia, parapet and chajjas, surface finished even and fair including water proofing compound by weight as per manufacturer's instructions, including necessary scaffolding up to (G+3 storey) complete all as specified and as directed. |
| 10 | M&L for preparation of new plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and as directed. |
| 11 | M&L for complete removal of existing treatment of old decorated external surface of walls by electrically operated grinder including necessary scaffolding etc and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and as directed by Engineer - in- charge. |
| 12 | M&L for 18 to 20mm thick granite (of jet black) work (table rubbed and polished ) as in steps, jambs, gate pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. Note:- The cost of rounding nose and make half round shall be deemed to be included in unit rate. |
| 13 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15cm thickness (below or above ground level) complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in floor etc complete all as specified and as directed. |
| 15 | M&L for coloured chequered cement concrete tiles of size (30cm x 30cm) x 25mm thick, set, jointed and pointed in neat cement slurry in floor with and including over 20mm screed bed in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for heavy duty digital parking tiles (30cm x 30cm) x 8 to 10mm thick, set, jointed and pointed in neat cement slurry as in floor with and including over 20mm thick screed bed in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for 60mm thick machine pressed with grey cement and pigment interlocking factory made paver blocks of any size and shape conforming to IS 15658-2006, M-35 set, jointed and pointed in dry sand with and including over 25mm thick sand cushioning complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in kerbs or mud stops, rounded or chamfered edges, etc complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for precast cement concrete louvers and jallies, 55mm thick (measured solid) in PCC (1:2:4) type B0 (using 12.5mm graded stone aggregate) set in cement mortar (1:4) including all mouldings but excluding frame complete all as specified and directed by Engr-in-Charge. |
| 20 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 21 | Excavation in post holes each not exceeding 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with around earth in layers not exceeding 25cm thick, watering and removing surplus spoil to a distance not exceeding 50m and making good surface complete all as specified and as directed. |
| 22 | M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 23 | S&F steel work in tubular/square/rectangular hollow section/angle iron, tee etc. for trusses/ purlins, rafter & sunshade including special shaped washer etc. complete using ERW or induction butt welded tubes using Fe as per IS 4923, Grade YST 310 including necessary machinery for upto 10m height structure complete all specified and as directed. |
| 24 | S&F MS angle iron as in fencing posts, struts & \\"Y\\" angle holes drilled in for securing wire including cutting top to shape & with flat iron for securing wire mesh including all necessary drilling, bolting or riveting, weldings etc Fe-290 grade 165, complete all as specified and as directed. |
| 25 | Dismantling CGI corrugated steel sheeting any gauge thickness including Nainital or similar pattern roof coverings, complete all as specified and as directed by Engineer-in-charge. |
| 26 | S&F 0.50mm thick Pre-painted galvalume aluminium Zinc coating steel GI based corrugated sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self taping screws complete all as specified and as directed. |
| 27 | M&L for preparation of new steel and iron surface of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 28 | M&L for applying two coat of synthetic enamel paint on old concrete surfaces or kerb stone of any description over 10cm girth or width including necessary preparation complete all as specified and as directed. |
| 29 | S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 30 | S&F in repair galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and as directed. Note:- Each line of wire shall be measured. |
| 31 | S&F in repair concertina coil fencing with punched tape of 900mm dia, centre core wire shall be minimum 2.5mm dia of mild steel wire conforming to IS 280-2006, galvanised coating of steel concertina coil conforming to the requriments as laid down for medium coated wire in IS 4826, Hot dipped galvanised coating of round steel wires concretina coil shall be fixed in diamond shape with the help of dovetail two handle and spikes shall be fixed in diamond shape with help of dovetail two handle and spikers shall be fixed at both end of coil, minimum straight length of the wire 150 RM of 10 RM of work, minimum weight 13.5 Kg for 10 RM of work i.e. 90 gm per RM of wire complete as specified and as directed. |
| 32 | M&L washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed. Note:- Payment for providing grooves shall be made separately. |
| 33 | Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |