| 1 | De-watering of septic tanks ,soakage wells,sump , static water tanks and grease trap of any depth, with sewer suction cum jetting machine /super honey sucker machine and draining out the same and taking out thick/solid sludge (sedimented sand sludge/grit ,ash rages , fibres and springe material etc)disposal of sludge/liquid outside MOD land in pit to be dug out side and covering top with a layer of 25 mm thick earth filling compacting and levelling all as specified and directed by Engineer-in-Charge. , complete, all as directed and to the entire satisfaction of Engineer-in-Charge.(i) Digging of pit shall be deemed to be included in unit rate.(ii) Contractor will maintain the hygienic condition in area all the time by taking suitable required measures.(iii)Cost of earth work in the pit is deemed to be included in the unit rate quoted by the tenderer).(iv) Manual cleaning will be done with wirebrush and other tools to remove algae and other greasy material after dewatering in case of static water tank.(v)Main holes before sump shall be blocked properly before cleaning and shall be opened immediately after cleaning. |
| 2 | S&F One piece EWC seat soft closing seat cover fixed in repairs all as required and specified by Engr-in-charge.(Make - Cera , Hindware & Parryware) |
| 3 | S&F One piece EWC seat cistern flushing kit (push button type) in repairs all as required and specified by Engr-in-charge.(Make - Cera , Hindware & Parryware) |
| 4 | Excavation in trenches not exc 1.5m wide and not exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed by . |
| 5 | Returning,filling in trenches including spreading watering and well ramming in layers not exc 25cm thick in soft.loose soil complete all as specified and as directed . |
| 6 | Removing excavated materials to a distance not exc 50m and depositing where directed by EIC at a levlel not exc 1.5 m above the starting point. |
| 7 | Providing PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation complete all as specified and directed. |
| 8 | Demolition of brick work built in cement mortar including all quoins,arches pillars etc all as specified and directed by Engr-in-Ch. |
| 9 | M&L for Brick work built in cement mortar 1:6 using old size sub class \\"B\\" bricks in wall straight or curved on plan exc 6m mean eadius complete all as specified and directed . |
| 10 | M&L for Providing PCC 1:2:4 type B-1 using 20mm graded crushed stone aggragate as in benching & coping including necessary form work complete all as specified and directed .. |
| 11 | Taking down cement plaster of any description on brick walls or concrete surfaecs etc. including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed . |
| 12 | M&L for 15mm thick rendering in cement mortar(1:6) on other than fair face of brick work or concrete surfaces finished surface even and smooth with using extra cement complete all as specified and as directed by EIC. |
| 13 | Material and labour, preparing of newly plastered surfaces of wall and applying two coats of white wash complete all as specified and directed. |
| 14 | Demolition and breaking up drain pipes 150 mm internal dia( SGSW/NP-2 pipe), AC or reinforced concrete set in cement mortar complete all as specified and directed . |
| 15 | Demolition and breaking up drain pipes 200 mm internal dia( SGSW/NP-2 pipe), AC or reinforced concrete set in cement mortar complete all as specified and directed . |
| 16 | M&L for Cement concrete bed to drain pipe and packing under haunching against side of pipes after laying in PCC (1:3:6) type C-2 using 40mm graded stone aggregate for 150mm dia SGSW / RCC NP-2 pipe complete all as secified and directed |
| 17 | M&L for Cement concrete bed to drain pipe and packing under haunching against side of pipes after laying in PCC (1:3:6) type C-2 using 40mm graded stone aggregate for 200mm dia SGSW / RCC NP-2 pipe complete all as secified and directed |
| 18 | M&L for 150mm internal dia Reinforced concrete pipes, class NP2, laidand jointed complete with collars laid in trenches and jointed in cement mortar complete all as specified and directed |
| 19 | M&L for 200mm internal dia Reinforced concrete pipes, class NP2, laidand jointed complete with collars laid in trenches and jointed in cement mortar complete all as specified and directed |
| 20 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Minimum weight 60gms) all as specified and directed by Engineer-in-charge. |
| 21 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for |
| 22 | M&L for providing precast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in precast manhole cover slab,chullah hoods, chajjas and other similar articles with plain faces including necessary form work complete all as specified and as directed |
| 23 | S&F mild steel TMT bars 5 mm dia and over upto 10mm (including 10mm) cut to length bent to shape reqd, incl cranking bending spirally for hooping for col,hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia or securing with clips qty confirming to Fe-410W(Gde- E-250) or Fe-290(Gde-E-165) complete all as specified and as directed. |
| 24 | Cleaning of underground sewage pipe line of 150mm dia including manholes by using suitable measures required as per site condition ( i.e. pressure pump) and taking out all liquid ,solid waste matters,sewage and sludge,night soil refuse etc and burying in a pit to be dug out side the defence land and covering top of pit with earth in layers of 25mm thick ness each complete all as specified and as directed .(The rate shall be deemed to include cleaning of manholes also and the length shall be measured including manholes.) |
| 25 | ditto as per Ser Item No 24 above but 200 mm dia. |
| 26 | Dewatering and cleaning of man hole not exc 1.5 m depth, incl removing solid/liquid waste material from Man hole /tanks/pits by sewer suction machine/Honeysuckers or similar arrangement and depositing off the material to a distance exc. 1000 mtrs all as entirily complete satisfaction of Engineer-in-charge. |
| 27 | Dewatering and cleaning of man hole exc 1.5m depth but not exc 3.00 m depth, incl removing solid/liquid waste material from Man hole /tanks/pits by sewer suction machine/Honeysuckers or similar arrangement and depositing off the material to a distance exc. 1000 mtrs all as entirily complete satisfaction of Engineer-in-charge. |
| 28 | Cutting into existing manholes for connecting new drains 150mm internal dia old pipe and making good to pipe and rendering cutting out existing benching for forming branch channel (1/2 Band to 3/4 section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished, and reforming benching as required all as specified and directed |
| 29 | Cleaning of blocked/chocked gully trap, floor trap,WHB, WC etc upto first man holes of any type and any dia and depth removing the sludge/solid content by mechenical method and cleaning the sewage line upto first manhole by mechanical means at the discretion of the contractor at his own arrangement so as to remove the blockage and making the sewer line/manhole fully functional to the entire satisfaction of Engr In Charge including removing the sludge beyond 50 mtr from bldg and repositioning the manhole cover in position and refixing of grating complete all as specified & directed by Engineer-in- charge. |
| 30 | M&L for Cleaning of blocked manholes of depth not exceeding 1.5 m, of any size, bailing out sludge/foreign matter and removing the same and burying in grounds at depth 1.00Mtr below GL at a distance n.exc 50 Mtr and placing back the manhole cover in original position |
| 31 | All as per item No. 30 above but depth exceeding 1.5 m and not exceeding 3.0 m etc complete all as specified. |
| 32 | S&F 32 mm dia PVC flexible pipe of suitable length for wash hand basin or urinal fixed in repairs complete all as specified and directed.( Make : Prayag , shakti , jainko ) |
| 33 | Taking down eaves gutters and rain water pipe (any size or any pattern) including all fittings, heads, shoes, bends, swan necks etc (measured over all as fixed along the central line over fittings and accessories) complete all as specified and directed by Engineer -in-charge. |
| 34 | M&L for 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches or in floor and in sewage soil waste or in rain water complete all as specified and directed |
| 35 | PVC (SWR) bends 110mmdia radius connected properly to pipes with solvent all required and specified Engr-in-charge. |
| 36 | S&F in repairs Vitreous China urinals, half stall complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement;, flush pipe, grating and Union for discharge pipe including waste pipe and urinal spreader complete all as specified.. |
| 37 | S&F in repair for Vitreous China wash down water closet pan ( pedestal pattern) white ( excluding flushing cistern and flush pipe) including plastic water closet seat closed pattern with flat botton and cover and mild steel chromium plated or aluminized hinging device complete all as specified and directed. |
| 38 | S & F in repair 10 ltrs capacity PVC low level syphonic action type flushing cistern including ball valve, bracket, inlet, outlet, overflow, PVC connection complete. |
| 39 | S & F vitreous china squating pan ''Orissa pattern size 580 x 440mm white with integral foot rest (excluding, flushing cistern and flush pipe) squating pan including connection ''P'' trap and to flushing pipe complete all as specified and directed. |
| 40 | S&F 500 Ltr capacity, Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl dismantling old tank all as specified in SSR Part I. |
| 41 | S&F in repair Vitreous china wash basin white flat back 550 x 400 mm without pedestal , with fitting of PTMT waste coupling suitable size ,PVC waste pipe ,angle iron brackets with painting of brackets etc fixed in repairs complete all as specified and directed. |
| 42 | Dismantling floor,hearth or wall tiling including cement mortar bedding (without backing), removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 43 | M&L for ceramic glazed coloured tiles of size 350x250x7mm/ 450x350x7mm thick joint free on and incl 10mm thick screed bed in cm(1:4)set and jointed in neat cement slurry and pointed in colored cement mixed with pigment to match the colour of tiles on vertical surfaces as cladding ,skirting and dado complete all as specified and directed by Engr-in-charge. |
| 44 | M&L for non skid dark/ coloured ceramic tiles 7 to 8 mm thick joint free (square/rectangular) area of each tile exceeding 0.11 sqm to 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement or clolured cement to match including 15 mm thick screed bed in cm 1:6 complete all as spc. |
| 45 | M & L for 25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 46 | S&F incl taking up and down GI tubing 15mm bore medium grade, fixed to wall/ceiling or floor in concealed pipe work including making good the chases etc in cement mortar(1:3) after fixing of pipe,complete all as specified and directed.(Rates for cutting of chases is included in respective items of taking down).complete all as specified and directed |
| 47 | S&F incl taking up and down GI tubing 20mm bore medium grade, fixed to wall/ceiling or floor in concealed pipe work including making good the chases etc in cement mortar(1:3) after fixing of pipe,complete all as specified and directed.(Rates for cutting of chases is included in respective items of taking down).complete all as specified and directed |
| 48 | S&F in repair Concealed stop cock 15mm bore dia,cast copper alloy, chromium plated screwed down high pressure,with crutch or buterfly handle,screwed both ends for pipes or for unions incl repair to surface to match the existing surface complete all as specified and as directed. |
| 49 | S&F in repair 15mm bib cock,cast copper alloy chromium plated fancy type15mm bore with capstan handle,screwed down,screwed from iron pipe or for brass ferrule, complete all as specified and as directed. |
| 50 | S&F in repair 15 mm bore stop valves/ angle valves fancy type chromium plated screwed dwon high pressure with cruth or butterfly handle for 15 mm dia iron pipe fixed in repairs complete all as directed. |
| 51 | S&F in repair brass chromium plated shower roses with swivel joints, 125 mm size in square with CP long shank arm including fixing to steel pipe or union, complete all as specified and as directed. |
| 52 | S&F in repairs 20 mm float/BALL valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass ferrule complete all as specified and directed by engineer in charge . |
| 53 | S&F in repair 15mm Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm 125gms). |
| 54 | S&F in repair PVC connection pipe ready made for connecting cistern, WHB etc 15mm dia 450 mm long with PTMT nuts, complete all as specified and as directed. |
| 55 | Coupling of PTMT half or full threaded 75/100 mm dia for kitchen sink fixed in repairs complete all as specified and directed. |
| 56 | S&F in 75 mm dia PVC (SWR ) floor trap/ nahani trap with grating, plain with grating including jointing with solvent cement complete all as specified and directed |
| 57 | Demolition of cement concrete ( unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed |
| 58 | S & F in repair PVC (SWR) bend/Door bend any radius for 110 mm bore pipe incl jointing material complete all as specified and directed. |
| 59 | S & F in repair PVC (SWR) junction single, (Single T) equal or unequal for 110mm dia bore complete all as spd and directed by Engr-in-Charge |
| 60 | S & F PVC in repair (SWR) vent cowl equal or unequal for 110mm dia bore complete all as spd and directed by Engr-in-Charge |
| 61 | M & L PVC in repair gully traps square of size 125mm x 110mm including for setting and jointing to drain with CM 1:1 etc complete all as specified & directed. |
| 62 | Note: The Total amount shall subject to adjustment of credit for old Materials as per Schedule of Credit. Please Enable Macros to View BoQ information |