| 1 | Demolition of brick work or stone/ boulder masonary, kerb stone, built in cement mortar including all quoins arches pillars etc, complete all as specified & directed. |
| 2 | Demolition of cement concrete in ground floors and paving (un reinforced) n exc. 15 cm. thickness, below or above ground level, complete all as specified & directed. |
| 3 | Demolition of cement concrete (reinforced) of any description and in any position, all as specified & directed. |
| 4 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, all as specified & directed. |
| 5 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified & directed. |
| 6 | Dismantling fencing wire mesh, any type complete all as specified and directed. |
| 7 | Dismantling of galvanised barbed wire of any description or in any positon complete and removing from site, all as specified & directed. |
| 8 | M&L for Brick work in cement mortar 1: 4, using sub class ‘B’ bricks, straight or curved on plan exc. 6m mean radius complete all as specified and as directed. |
| 9 | M&L for Brick work in cement mortar 1: 4, using sub class ‘B’ bricks, straight or curved on plan exc. 6m mean radius but except brick, i.e. using serviceable bricks obtained from demolition, complete all as specified and as directed. |
| 10 | M&L Plain Cement concrete in surface channels and drains Type B2 1:2:4 40mm graded aggregate complete all as specified and driected. |
| 11 | M & L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 12 | M&L for RCC M-20 (Nominal mix) as beams,cantilevers,bressummers, lintels over 1.5 m span and similer work complete all as specified and as directed. |
| 13 | M&L for RCC M-20 (Nominal mix) as Columns,pillars, piers,posts and struts and similer work complete all as specified and as directed. |
| 14 | M&L for RCC M-20 (Nominal mix) as in foundation ,including rafts, footing foundation beams, plinth beams for columns. etc complete all as specified. |
| 15 | M&L for Formwork to sides of concrete foundation, footings bases of columns, raft and raft beams, plinth beams and similae work vertical or to batter complete with Rough finished flat surfaces complete all as specified. |
| 16 | M&L for Form work to side pillars, post, strust, pier, columns and similar works squar or rectangular rough finished flat surfaces to concrete. |
| 17 | M&L for Form work to sides and soffits of floor or roof beams , haunchings, girders , bressummers, lintels, cantilevers, shelves including sup- posts, overhangs, etc. also splays between floors and beams, etc including rough finished to concrete surfaces. |
| 18 | M & L TMT steel bars 10mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping to columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia, all as specified and directed. |
| 19 | M & L TMT steel bars 5 mm dia and over upto 10 mm dia as in stirrups spacers and binders , cut to length bent to shape required, including cranking, bending spirally for hooping ,hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia, all as specified and directed. |
| 20 | Excavation in post holes for any type of soil each n.exc 0.5 Cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 2Cum watering out rawing and removing surplus soil to a distance n.exc 50m and making good. |
| 21 | M&L cement concrete type C2 (1:3:6) 40mm graded aggregate) in foundation, filling and mass concrete. Complete all as specified & directed. |
| 22 | Supply only Chain link MS galvanisd fencing, any size or type wieght n exc 4.00 kg per Sqm complete all as specified and directed. |
| 23 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 24 | S & F Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing ro any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc, as directed (each line wire to be measured) complete all as specified and directed. |
| 25 | M&L flat iron fillets fixed to the fencing posts incl all necessary drilling bolting or riveting etc and similar work conforming ot Fe 410-0 grade E 250 quality A. complete all as specified and directed. |
| 26 | S&F 10 mm dia Mild screw bolts machine made) with hexagonal or square heads at one end and screwed the other, or screwed on both ends each screwed end to be fitted with washers and one hexagonal or square nut but length of bolt exc 10cm but n exc 15cm long. |
| 27 | S & F MS framed work such as in gate grills, gratings, framed guard bars, angle iron, plate etc and similar work including necessary pintle hinges, stops, welding, riveting, bolting , hold fast , sliding bolt and other necessary fitiings confirming to Fe 410-0 or Fe 310-0, all as directed |
| 28 | S&F 10 mm dia MS round bar fixed to chain link fencing top and bottom complete all as specified and directed. |
| 29 | M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cm 1:6 finished even and smooth with neru finish to plaster work complet all as specified and directed. |
| 30 | M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces in cm 1:4 using Water proofing compound as per manufacturer's instructions finished even and smooth (with out using extra cement) complet all as specified and directed.(WPC measured and paid seperately) |
| 31 | Supply only Integral Water compound liquid, all as specified & directed. |
| 32 | M&L for 75 mm thick PCC 1:4:8 type D-2 using (40mm graded crushed stone aggregate ) as in sub base of floor complete all as specified and directed. |
| 33 | M&L for Precast designer coloured heavy duty full body paving tiles (factory made) of size 300mmx300mm x 10mm, top layer glazed made in any type of cement and pigment, in required patterns as approved by GE in floor etc including set & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:4, complete all as specified & directed. |
| 34 | M&L Chequered cement concrete tiles 20cmx20cmx25mm thick set, jonted and pointed in slurrry in floors with mixture of white & grey cement in equal proportion and no pigment.over and including 15mm thick screed layer in cement mortar 1:4 complete all as specified and direceted. |
| 35 | M&L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 36 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 37 | M&L for Preparation of new steel surface over 10cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed. |
| 38 | M&L for two coat of Apex paint (weather coat exterior paint), (light / dark shed) on new plastered wall through normal application methodology using machinery etc complete upto the height of 7.5 mtr over one coat of alkali resistant primer all as per manufacturers instruction and directed by GE. |
| 39 | M&L for Preparation of old steel surface over 10cm in width or girth and applying two coat of synthetic enamel paint complete all as specified and directed. |
| 40 | M&L for Preparation of old ,plastered or unplastered surfaces including brooming down or steel wire brushing,scrapping down smokesoot,moulds,moss and efflorescent salts and trading oil greasy spots, and applying two coats of Apex paint (weather coat exterior paint) on wall complete all as specified and directed. |
| 41 | M & L 100 mm thick PCC (1:2:4) type B2 using 20 mm graded stone aggregate laid in alternative bays finished the surface even and fair without using extra cement complete all as specified and directed. |
| 42 | M&L for Forming Contration (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound (1Bitumen: 3 Sand) Grade A complete all as specified and direcetd. |
| 43 | M&L for Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) CM 1:6 in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional arean exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops complete all as specified and directed. |
| 44 | M & L for Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded granite stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 45 | Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed. |
| 46 | All as per Srl item No.1 above but depth exc 1.5m and not exc. 3.0m deep in any type of soil. |
| 47 | Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed. |
| 48 | Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed. |
| 49 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, internal dia of pipe 200mm, complete all as specifed & directed. |
| 50 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, internal dia of pipe 150 mm, complete all as specifed & directed. |
| 51 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, internal dia of pipe100 mm, complete all as specifed & directed. |
| 52 | M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate for 200mm dia bore pipes all as per SSR Part-I specifications, complete all as specified and directed. |
| 53 | M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate for 150mm dia bore pipes all as per SSR Part-I specifications, complete all as specified and directed. |
| 54 | M&L for Concrete bed to 100mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 type D-2 using 40mm graded stone aggregate, and tested,for 100mm dia bore pipes all as per SSR Part-I specifications, complete all as specified and directed. |
| 55 | S&F 200mm diameter DWCPE (SN8) HDPE Pipes laid in trenches on PCC bed including jointing as per manufacturer's instructions and all as specified & directed. (Bedding/Haunching and earthwork paid separately under respective items of schedule) |
| 56 | S&F 150mm diameter DWCPE (SN8) HDPE Pipes laid in trenches on PCC bed including jointing as per manufacturer's instructions and all as specified & directed. (Bedding/Haunching and earthwork paid separately under respective items of schedule) |
| 57 | S&F 100mm diameter DWCPE (SN8) HDPE Pipes laid in trenches on PCC bed including jointing as per manufacturer's instructions and all as specified & directed. (Bedding/Haunching and earthwork paid separately under respective items of schedule) |
| 58 | M & L Cutting into existing manholes for connecting new drains (internal dia of pipe 200mm), including making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required |
| 59 | M & L Cutting into existing manholes for connecting new drains (internal dia of pipe 150mm), including making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required |
| 60 | M & L Cutting salt-glazed stoneware drain pipe in position new drains (internal dia of pipe 100mm), including making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required |
| 61 | M & L PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in benching, water troughs and the like including necessary form work, complete all as specified & directed. |
| 62 | M&L for Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed. |
| 63 | Dismantling water tanks of capacity exc 250 litres but n exc 500 litres, complete all as specified & directed. |
| 64 | Dismantling water tanks of capacity exc 500 litres but n exc 1000 litres, complete all as specified & directed. |
| 65 | S&F Rotational moulded polyethlene water storage tanks , triple layered, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of Capacity 1000 litres including over flow , drain out pipe and all accessories complete all as specified. |
| 66 | S&F Rotational moulded polyethlene water storage tanks , triple layered, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of Capacity 500 litres including over flow , drain out pipe and all accessories complete all as specified. |
| 67 | Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed. |
| 68 | Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed. |
| 69 | S&F Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 70 | S&F Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, bows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, complete all as specified and directed. |
| 71 | Refixing old steel tubing and connections of 20mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed . |
| 72 | Refixing old steel tubing and connections of 15mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed . |
| 73 | S&F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for bore of pipe 20mm, fixed in repairs, complete all as specified & directed. |
| 74 | S&F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for bore of pipe 25 mm, fixed in repairs, complete all as specified & directed. |
| 75 | S&F Vitreous china wash down water closet (Pedestal pattern), white including ‘P’ or ‘S’ trap, plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device fixed with screws of suitable size including making connections to trap and to flush pipe, fixing flushing cistern etc. and making good to floors, fixed in repairs, complete all as specified & directed. |
| 76 | S&F Vitreous chinaware squatting pan, 'Orissa Pattern' size 580mm x 440mm including integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified & directed. |
| 77 | S&F PVC valveless, syphonic action type flushing cistern, 10 litres capacity, plunger type, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long, fixed in repairs, complete all as specified & directed. |
| 78 | S&F Vitreous china wash basin white flat back size 580x450 mm excluding taps waste chain and plug and porcelain stopper but including brackets, fixed in repair, complete all as spd & directed. |
| 79 | S&F PVC (SWR) floor trap , plain with grating including jointing with solvent cement of 75mm outlet dia all as specified |
| 80 | Dismantling of cast iron or reinfored concrete drain pipes, or PVC (SWR) pipe jointed in cement mortar and taking out of trenches, if required, internal dia of pipe75/ 100mm, complete all as specified & directed. |
| 81 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with MS clamps, 110mm bore, complete all as specified and directed. |
| 82 | S&F 110mm bore PVC (SWR) bends any radius, complete all as specified & directed. |
| 83 | S&F PVC (SWR) branch piece, (single Y) equal or unequal 110mm bore all as specified and directed |
| 84 | S&F PVC (SWR) junction single (Single T) equal or unequal, 110mm bore, complete all as specified & directed. |
| 85 | S&F PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified & directed. |
| 86 | S&F PVC (SWR) bends any radius 75mm bore all as specified & directed. |
| 87 | S&F PVC (SWR) branch piece, (single Y) equal or unequal 75mm bore all as specified and directed. |
| 88 | S&F PVC (SWR) junction single (single T) equal or unequal 75mm bore all as specified and directed. |
| 89 | S&F PVC(SWR) vent cowl 75 mm bore all as specified and directed. |
| 90 | Cleaning/ clearing of sewage line (including manholes) of 200mm bore of any description, underground at any depth, removing any type of blockage including desilting, descaling & dechocking of drains as well as manholes with combined high pressure water jetting cum suction (vacuum) type machine mounted on LCV/ HCV and having facilities of high pressure vacuum and provision of hydraulic application through high pressure thermo plastic fibre based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, complete all as specified & directed. |
| 91 | Cleaning/ clearing of sewage line (including manholes) of 100mm to 150mm bore of any description, underground at any depth, removing any type of blockage including desilting, descaling & dechocking of drains as well as manholes with combined high pressure water jetting cum suction (vacuum) type machine mounted on LCV/ HCV and having facilities of high pressure vacuum and provision of hydraulic application through high pressure thermo plastic fibre based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, complete all as specified & directed. |
| 92 | M&L for cleaning of septic tank/soakage pit of any size, type and any depth and removing the sludge/solid content from the septic tank/soakage pit by using honeysucker mechanical method (as per direction by AGE/JE) or any other suitable means at contractors own arrangements including flushing with fresh water and make the septic tank/soakage pit fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and respositioning of the RCC/CI cover slab all as directed by GE. |
| 93 | Desludging / dewatering of septic tanks/ soakage wells including inlet / outlet chambers, including removing out all scum, silt, residual sludge (both organic & inorganic in nature) after plugging the incoming sewage lines through by mannual, all as directed by GE. |
| 94 | Cleaning of blocked WC including and upto first manhole manully and well flushing with clear water, making the seat functional including deposting the sludge in a pit(including digging of pit) not less than 100 mtr away from site of cleaning and covering the deposited sludge with minimum 25cm thick layer of earth and spreading unslacked lime on the pit all as specified and as directed by GE. |
| 95 | Dismantling floor, hearth or wall tiling , terrazzo topping on walls including cement mortar , bedding (but no backing) removing serviceable tiles and rubbish off the premises complete all as specified and directed. |
| 96 | M&L for Non Skid coloured ceramic tiles 300 x 300 x 7 to 8 mm thick in floors etc. Including set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 all as specified and directed. |
| 97 | M&L for Glazed ceramic coloured tiles of size 450X 300X 7mm thick as in vertical surfaces such as skirting, dado, wall etc. Including set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed. |
| 98 | S&F in repairs CP alloy jet spray with flexible pipe n.less than 90 cm long fixed to EWC suitable for 15mm bore complete all as specified and directed. |
| 99 | S&F in repair Hand shower (Health faucet) brass chromium plated including 1.25 meter long easy flex tube of 15mm dia in chrome finish and wall hook, fixed in repair, complete all as specified. |
| 100 | Supply and fixing in repair PVC Waste pipe 32mm bore of required length complete all as specified and as directed. |
| 101 | S&F Looking mirror 600 x 450 x 5mm beveled edge mirror of selected quality glass 5mm thick mounted on 6 mm thick AC building board or commercial ply and fixed to wooden plugs with CP brass screws and cup washers etc, fixed in repairs, complete all as specified. |
| 102 | S&F Tubular towel rail, brass chromium plated, 20 mm dia, D type, 60 cm long between Hangs, fixed in repairs complete all as specified and directed. |
| 103 | S&F in repair stainless steel lock grating plain/hole size 100 mm dia including embeding in tiles with white cement complete all as specified and as directed. |
| 104 | S&F Fancy type Brass CP wash hand basin mixer for mixing hot & cold water, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unions fixed in repairs complete, all as specified. |
| 105 | S&F Stop cock 20 mm cast cooper alloy of screwed down high pressure with crutch or butter fly handle , screwed with ends for iron pipe or unions fixed in repairs. Make ISI marked |
| 106 | S&F Stop cock 15 mm cast cooper alloy of screwed down high pressure with crutch or butter fly handle , screwed with ends for iron pipe or unions fixed in repairs. Make ISI marked |
| 107 | S&F Bib taps 15mm dia cast copper alloy fancy type chromium plated, screwed down for iron pipe or for brass ferrule fixed in repair complete all as specified and directed.(Make : Prayag or equivalent) |
| 108 | S&F Stop valve 15mm dia cast copper alloy chromium plated fancy type with long shank and cup (concealed type) srewed both ends for iron pipe or for union and fixed in repair all as spd & directed |
| 109 | S&F Angle valve 15 mm fancy type, chromium plated 15 mm of cast copper alloy, screwed down for iron pipe ,fixed in repairs complete complete all as specified and directed. |
| 110 | Demolition of cement concrete in and paving (un reinforced) exc. 15 cm. thickness, below or above ground level, including removal of waste from defence land and dumping at a place as specified by civil authorities complete all as specified |
| 111 | M&L for sunken treatment with glass fiber reinforced modified cementitious coating system before the final coat of Latex Shield 2K (or equivalent) complete all as following :-Base Coat : Berger HS Latex plus (or equivalent)consumption base coat : 0.3 kg/m2Reinforcement : Glass fiberSecond and Third coat : Latex sheild 2K (or equivalent)Consumption top coat : 3 kg/m2System reqquirements : density : 2.00 kg/ltr;Compressive strength: 0.5N/mm2Wall penetration through the RCC slab must be sealed using Berger HS Repair (or equivalent).Intersection of base slab with wall must be provided with a 50 mm fillet using Berger HS Latex plus (or equivalent) modified mortar with a bonding coat of Berger HS Latexplus (or equivalent) modified cement slurry upto sft.All depressions, unevenness, surface honeycombng shal be repaired using Berger HS Latex plus (or equivalent) modifiled polymer mortar with a bonding coat of Berger HS latex plus (or equivalent) modified cement slurry.Including cleaning of RCC surface to remove dust, loose paricles, etc with compressed air or any other suitable technique depending on site conditions, grinding aby sharp edges, etc.Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix 'AB' on page no. 90 of tender documents as per Sch 'A' Note No 19 Page No 17). |
| 112 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with water proofing compound tobe finished even and smooth without usingextra cement complete all as specified and as directed (WPC to be measured separately) |
| 113 | Supply only Integral water proofing compound liquid, complete all as specified & directed. |
| 114 | S&F 20mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in as spout pipes to pour out rsidual water out from the treated area, all as specified & directed. |
| 115 | M&L for hard core, of broken bricks broken to gauge n exc 63mm for laying sub base of thickness 150mm complete all as specified and directed. |
| 116 | M&L Cement concrete type D-2 1:4:8 (40mm graded crushed stone aggregate) as in foundations, filling and mass concrete in sub base, complete all as specified & directed. |
| 117 | M&L for 25mm thick PCC (1:2:4) type B1 with 20mm graded aggregate for laying floor tiles, complete all as specified & directed. |
| 118 | M&L for non skid coloured Ceramic tiles 8 to 10 mm thick in light shade (square/ rectangular) polished, area of each tiles exc 0.11 sqm but not exceeding 0.18 sqm, in floors/Skirting etc. Including set, jointed and pointed including tile adhesive anti slip white @1.2kg/sqm thickness upto 8 to 10mm (or equivalent) and epoxy material for sealing of tile joints with Epoxy tile grout(or equivalent) to the floor of toilets and bathroom complete all as specified and directed. Please Enable Macros to View BoQ information |