Housing Urban and Rular Development Local Bodies Closing in 2 days TDR #55941549

Tender For Elecrical Work For Nkda Unit Office At Action Area-Iiie, New Town, Kolkata Under Nkda

Issued by Local Bodies · AA-III New Town, Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Jul 2026
2 days left
EMD
16000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
AA-III New Town, Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Elecrical Work For Nkda Unit Office At Action Area-Iiie, New Town, Kolkata Under Nkda

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Jun-2026 CORRIGENDUM-I Date 27-Jun-2026
2 29-Jun-2026 CORRIGENDUM-II Date 01-Jul-2026
3 22-Jun-2026 CORRIGENDUM-I Date 27-Jun-2026
4 02-Jul-2026 CORRIGENDUM-III Date 04-Jul-2026
5 07-Jul-2026 CORRIGENDUM-IV Date 11-Jul-2026

BOQ

Name of Work:- Elecrical work for NKDA unit office at Action Area-IIIE, New Town, Kolkata under NKDA
Sl. No. Item Description
1Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provisionfor earthing attachment (A) 4 way
2Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection, A) 100A FP
3B) 63A FP
4Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection, A) 6-32 A SP
5B) 63A FP
6Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. A) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
7B) 2 x 56/0.3 (4 sqmm) + 1 x 22/0.3 (1.5 sqmm)
8Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required, a) 3 x 84/0.3 (6 sqmm) + 2 x 56/0.3 (4 sqmm) ECC
9Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface], Average run 5 mtr
10Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] A) On Board.
11B) Average run 1.5 mtr
12Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. Connections with PVC Cu wire and earth continuity wire etc.
13Supply and fixing of Endural LED Bulk head Pressure Die cast housing LED Bulkhed with IP66 protection and IK09 impact resistane suitable for surface and wall mounted applications on ceiling fitting on wall / ceiling by screw etc. 10 watt LED Make (cromption, Havells, Panasonic)
14Supply of 6watt LED surface mounted down light
15Supply of 12watt LED surface mounted down light
16Supply of 10watt LED Mirror light
17Supply and fixing of philips soft glow office compliant fully defussed recessed mounted (2' X 2') false ceiling based LED light including connection by 1.5 Sq mm cu wire, 36 watt (Make: Philips, Panasonic, Bajaj)
18Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.
19Supply and delivery of 230 Volt. 50 Hz, Heavy duty Metal 12\\" Exhaust Fan
20Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 cm (12\\")
21Fixing only louver shutter/cowl on wall with necy. bolts & nuts(6 mm dia x 62 mm long)
22Supply and delivery of 1200 mm sweep, 1 phase, 60/70 watt, 5 star and having 300 mm down rod, 1.1mm thick alluminium bled, conforming IS 374, 2mm shank thickness ceilling fan of following make Havells/Crompton Greaves Make (60 watt):
23Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
24Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve)and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
25Supply of 2.0Ton Split Type Inverter Air condition Machine. (Mistubishi electric RJS22VF/ Mitsubisi Heavy SRK 24YYM-w6/O General ASGG24CPAB-B (R32) 3/4 Star
26Supply of1.5 Ton Split Type Inverter Air condition Machine. (Mistubishi electric RJS18VF/ Mitsubisi Heavy SRK 18VXP-w6/O General ASGG18CPAB-B (R32) 8 Star
27SITC including vaccumiazation and Nitrozen of testing of following nominal size of soft/hard drawn copper refregerent piping for packge / VRV/VRF/RAC system complete with fitting, with adjustable rig type hanger support, jointing / brazing including accessories, insulated with XLPE class-O tubular insulation / with clas-O closed cell elastometric nitrile rubber tubular sleeves section of specified thickness as given below for suction and liquied lines, all accessories as per specification etc. as required
285/8\\" (15.88 mm) ( softdrawn) cu,pipes ( as per standard BS864 or ANSIB16.22) mm inclu 19 mm thick insulator
293/8\\" (9 mm) ( softdrawn) cu( as per standard BS864 or ANSIB16.22 mm inclu 19 mm thick insulator
301/4\\" (6.4 mm) ( softdrawn) cu, ( as per standard BS864 or ANSIB16.22) mm inclu 19 mm thick insulator
31supply and laying 25 mm PVC Pipe (heavy tupe) for water drainage with 6 mm thick nitrial rubber insulation with propper spport & brackt as per directionMake: Suprime / Oriplast)
32Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
33Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
34Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages No. 8 SWG
35S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)
36Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works
37Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55941549
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 11-07-2026
Authority
Authority Name New Town Kolkata Development Authority
Work Description Tender for Elecrical Work For Nkda Unit Office At Action Area-Iiie, New Town, Kolkata Under Nkda
Basic Detail
Tender No NOTICE INVITING ONLINE ITEM RATE TENDER NO. WBNKDA/ 100 /EE-E/ 2025-26 (2nd Call)
Bidding Type Tender
Location
City AA-III New Town, Kolkata
State West Bengal
Key Dates
Publish Date 07 Jul 2026
Submission Date 11 Jul 2026
Open Date 13 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 16000
Exemption Not Available
Document List
7afdbce2-ed4b-40a1-b08d-07248dbe84b8.html
BOQ_2524393.xls
Tendernotice_1 (12).pdf
Tendernotice_100Call2UnitOffice.pdf
WBF2911.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jun 27, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 01, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 27, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 04, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 11, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Jul 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Jul 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

7afdbce2-ed4b-40a1-b08d-07248dbe84b8.html

xls

BOQ_2524393.xls

pdf

Tendernotice_1 (12).pdf

pdf

Tendernotice_100Call2UnitOffice.pdf

pdf

WBF2911.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders