| 1 | SITC Geyser | Supply installation commissioning and testing of electric water heater storage vertical type BEE 5 star rated 25 ltr capacity 230 volts AC 50 Hz comprising of high voltage heating element for instant heating extra thick SS inner tank of superior 304 grade rust shock proof ABS outer body non ferrous pressure plate with and including provision of 04 Nos grouting bolts suitably flush to wall or any other surfaces and connection pipe for hot and cold water supply 25 ltr BEE 5 Star rated complete stranded copper conductor cable flexible chord complete all as specified and as directed. |
| 2 | M and L Gi Tubing | M L for GI water tubing medium grade 15 mm dia fixed on wall with all fittings and fixtures complete all as specified and directed. |
| 3 | s and f stop valve | S F stop valve but fancy type chromium plated screwed down CP of size 15 mm fancy type complete all as specified and directed. |
| 4 | m and l bib tap | M L bib taps cast copper alloy with butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed for bib tap 15 mm dia fancy type all as specified and directed. |
| 5 | m and l point wiring | M L for point wiring complete for one power point for one metal plug socket for AC or one socket for geyser point on independent board with 4.0 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR LS cable 1100 volts grade ISI marked with proper colour coding drawn through and including non metallic rigid PVC medium grade conduit not less than 20mm dia and conduit accessories ISI marked concealed in wall fixed to roof ceiling etc including provision of 4.0 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR LS ISI marked as earth continuity conductor connected to common earth duly including cutting chases of existing wall for conduits and fixing for Metal Plug and socket boxes and making good to the disturbed surface of wall floor and matching with existing specifications. Connection of cable with MCBs or bus bar shall be done through proper size copper brass thimbles. |
| 6 | s and f epoxy powder enclosure | S F epoxy powder coated sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts C Series current carrying capacity 10 KA incl necessary connection complete all as specified and directed. |
| 7 | s and f mcb distribution board | S F MCB distribution boards DBs with sheet metal enclosure double door IP 43 protection 240 Volts 8 way single pole and neutral with 200 Amps rated copper bus bar as per OEM neutral link earth link earthing studs suitable for fixing MCBs without MCBs fixed flush to wall other surface complete all as specified and directed. |
| 8 | m and l earthing | M L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground Earth pit not less than 1.25M deep below normal ground level with top edge of the plate not less than 1.5m below normal G.L. Connected to a galvanized earth lead wire 4mm by means of nut bolt check nut and washers including necessary excavation and earth work in choorose soil GI protection pipe light grade 15mm bore for protecting GI wire mesh funnel alternate layer of charcoal dust and salt CC pit 1 3 6 type C1 using 20mm graded stone aggregate and 50mm thick RC 1 2 4 type B0 using 20mm graded stone aggregate covering 0.7m dia MS TMT bars 80mm C C both ways complete all as specified and shown in Electrical plate No.3 SSR part 1 and connected to the earth point and testing complete including taking out the old one complete all as specified and directed by Engr in Charge. |
| 9 | excavation | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation of poles stays cables etc and getting out in any type of soil. |
| 10 | returning filling | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm. |
| 11 | removing excavated material | Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting level. |
| 12 | m and l for sand cushioning | M L for sand cushioning in cable trenches over under the cable with river washed coarse sand as per standard practice with proper compaction complete all as specified and directed by Engr in Charge. Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part I |
| 13 | supply and laying brick protection | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common burnt clay building bricks sub class B old size brick and flat and width wise along the axis of the trench complete all as specified and directed by Engr in Charge. |
| 14 | s and f gi tubing | Supply and fixing 40 mm dia GI tubing medium grade ISI marked laid in trenches laid under floor for protection of cable including all fittings such as elbow bends etc and short length complete all as specified and directed. |