Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE 300X300X12 |
| 2 | EARTHING SUPPORT COIL TYPE |
| 3 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 4 | 100X50X60MM GI CHANNEL FOR STRAIGHT CROSS ARM 1.4 MTR EACH 3 NOS EACH ON PIN POINT POLE FOR CANTILEVER ARRANGEMENT & 6 NOS EACH FOR CP ARRANGEMENT ON CANTILEVER ARRANGEMENT |
| 5 | MOUNTING GI CHANNEL 75X40X6 - 1.4 MTR LONG 1 NO EACH FOR PIN POINT POLE & 2 NOS EACH FOR CP ARRANGEMENT @ 6.8 KG/MTR FOR SUPPORTING THE CANTILEVER ARRANGEMENT |
| 6 | CANTILEVER ANGLE FOR SUPPORTING CANTILEVER ARRANGEMENT 50X50X6 MM GI ANGLE (1 MTR LONG 13 NOS) @ 4.5 KG/MTR |
| 7 | GI BACK CLAMP CROSS ARM |
| 8 | 11 KV XLPE COVERED CONDUCTOR 55 SQMM AAA |
| 9 | DISC INSULATOR (B&S) 45 KN POLYMER |
| 10 | TENSION ASSEMBLY WEDGE TYPE WITH ANCHORING CLAMP FOR 11 KV COVERED CODUCTOR |
| 11 | IPC FOR COVERED CONDUCTOR 11 KV 55 SQMM |
| 12 | 11 KV PIN INSULATOR POLYMER |
| 13 | NON METALLIC TIES 11 KV FOR COVERED CONDUCTOR |
| 14 | MECHANICAL CONNECTOR WITH HEAT SHRINK SLEEVE FOR 11 KV 55 SQMM AAA COVEREC CONDUCTOR |
| 15 | HT STAY SET COMPLETE |
| 16 | HT STAY INSULATOR |
| 17 | HT STAY CLAMP (1.95 KG/PAIR) |
| 18 | 7/10 GI STAY WIRE |
| 19 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 20 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 21 | DANGER BOARD |
| 22 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 23 | GI NUTS BOLTS AND WASHERS |
| 24 | BLACK PAINT |
| 25 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 26 | SUNDRIES |
| 27 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE |
| 28 | EARTHING COLL SUPPORT |
| 29 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR -2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 30 | TOP PRESSURE GI CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 31 | AB SWITCH MOUNTING GI CHANNEL 100X50X6 MM CHANNEL EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 32 | AB SWITCH SIDE SUPPORT CHANNEL 100X50X6 MM 9.2 KG/MTR EACH CHANNEL LENGTH 0.35 MTR 2 NOS CHANNEL REQUIRED |
| 33 | CHANNEL SUPPORT FOR DOWN PIPE 75X40X6 MM 6.8 KG/MTR EACH CHANNEL LENGTH 0.8 MTR 1 NOS CHANNEL REQUIRED |
| 34 | GI CHANNEL FOR SUPPORTING DP ARM 75X40X6 MM 2.8 MT LONG 2 NOS 6.8 KG/MTR |
| 35 | BRACING ANGLE 50X50X6 MM GI ANGLE 4 MTR LONG 2 NOS 4.5 KG/MTR |
| 36 | DISC INSULATOR (B&S) 45 KN |
| 37 | TENSION ASSEMBLY WEDGE TYPE WITH ANCHORING CLAMP FOR 11 KV COVERED CODUCTOR |
| 38 | MECHANICAL CONNECTOR WITH HEAT SHRINK SLEEVE FOR 11 KV 55 SQMM AAA COVEREC CONDUCTOR |
| 39 | 11 KV PIN INSULATOR POLYMER |
| 40 | NON METALLIC TIES 11 KV FOR COVERED CONDUCTOR |
| 41 | 11 KV AB SWITCH 3 POLE 400 A |
| 42 | 11 KV LIGNTHING ARRESTER 9 KV 10 KA |
| 43 | IPC FOR COVERED CONDUCTOR 11 KV 55 SQMM |
| 44 | HT STAY SET COMPLETE |
| 45 | HT STAY INSULATOR |
| 46 | HT STAY CLAMP(1.95KG/MTR) |
| 47 | 7/10 SWG STAY WIRE |
| 48 | DANGER BOARD |
| 49 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 50 | GI PIPE EARTHING 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG |
| 51 | 50X6 MM GI FLAT FOR EARTHING 2.36 KG/MTR 2.5 MTR FOR MESH FORMATION AND 2.5 MTR FOR RAISING 5X2.36 |
| 52 | BACK CLAMP FOR DANGER BOARD 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH FOR EACH BACK CLAMP |
| 53 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) 4 PC/SUPPORT |
| 54 | GI, NUTS, BOLTS & WASHER |
| 55 | BLACK PAINT |
| 56 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 57 | SUNDRIES |
| 58 | 300 KG 9 MTR LONG PSC POLE |
| 59 | RCC BASE PLATE |
| 60 | EARTHING OF SUPPORT (COIL TYPE) |
| 61 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 62 | 100X50X6 MM CHANNEL FOR STRAIGHT CROSS ARM 1.2 MTR EACH 16 NO & 0.2 MTR LONG 16 NO (4 CUT POINT) & (02 NO TAPPING POPINT ) @ 9.2 KG/MTR |
| 63 | 11 KV V CROSS ARM 10.2 KG EACH WITH GALVANIZATION |
| 64 | GI BACK CLAMP FOR 11 KV V CROSS ARM |
| 65 | 11 KV F CLAMP 2.9 KG EACH WITH GALVANIZATION |
| 66 | 11 KV PIN INSULATOR POLYMER |
| 67 | 55 SQMM AAA CONDUCTOR |
| 68 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 69 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 70 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 71 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 72 | HT STAY SET COMPLETE |
| 73 | HT STAY INSULATOR |
| 74 | HT STAY CLAMP(1.95 KG/MTR) |
| 75 | 7/10 SWG STAY WIRE |
| 76 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 77 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 78 | DANGER BOARD |
| 79 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 80 | GI NUTS BOLTS WASHERS |
| 81 | BLACK PAINT |
| 82 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 83 | SUNDRIES |
| 84 | 300 KG 9 MTR LONG PSC POLE |
| 85 | RCC BASE PLATE |
| 86 | EARTHING OF SUPPORT (COIL TYPE) |
| 87 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 88 | TOP PRESSURE CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 89 | TRANSFORMER MOUNTING GI CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 90 | AB SWITCH & HG FUSE MOUNTING GI CHANNEL 75X40X6 MM 2.8 MTR LONG 4 NOS @6.8 KG/MTR |
| 91 | CANTILEVER GI CHANNEL FOR SUPPORTING AB SWITCH ARM 75X40X6 MM 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 92 | CANTILEVER ANGLE FOR SUPPORTING AB SWITCH ARM 50X50X6 MM GI ANGLE 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 93 | TRANSFORMER BELTING GI ANGLE 50X50X6 MM 2.8 MTR LONG 2 NOS @4.5 KG/MTR WITH SIDE ANGLE TOTAL 7 MTR |
| 94 | ANGLE FOR MOUNTING LT DISTRIBUTION BOX 50X50X6 MM GI ANGLE 1 MTR EACH LONG 2 NOS @4.5 KG/MTR |
| 95 | AB SWITCH SIDE SUPPORT CHANNEL 100X50X6 MM 9.2 KG/MTR EACH CHANNEL LENGTH 0.35 MTR 2 NOS CHANNEL REQUIRED |
| 96 | CHANNEL SUPPORT FOR DOWN PIPE 75X40X6 MM 6.8 KG/MTR EACH CHANNEL LENGTH 0.8 MTR 1 NOS CHANNEL REQUIRED |
| 97 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 98 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 99 | 11 KV AB SWITCH 3 POLE (200 AMP) |
| 100 | 11 KV HG FUSE 3 POLE (200 AMP) |
| 101 | LIGHTNING ARRESTER(9 KV,10 KA) |
| 102 | HT STAY SET COMPLETE |
| 103 | HT STAY INSULATOR |
| 104 | HT STAY CLAMP(1.95 KG/MTR) |
| 105 | 7/10 SWG STAY WIRE |
| 106 | GI PIPE EARTHING 40 MM DIA MEDIUM GAUGE 3 MTRS LONG |
| 107 | 25X4 MM GI FLAT(NEUTRAL) |
| 108 | 25X6 MM GI FLAT |
| 109 | 55 SQMM AAAC |
| 110 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 111 | GI NUTS,BOLTS,WASHERS |
| 112 | 100 KVA 11/0.4 KV AL TRANSFORMER BIS ENERGY LEVEL -II |
| 113 | LT DISTRIBUTION BOX WITH MCCB, ALUMINIUM BUSBAR FOR 2 BAY WITH KITKAT FUSE FOR 100 KVA SUBSTATION |
| 114 | 1CX185 SQMM LT XLPE CABLE ARMOURED @ 15 MTR EACH |
| 115 | DANGER BOARD |
| 116 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 117 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 118 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 119 | BLACK PAINT |
| 120 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 121 | SUNDRIES |
| 122 | 8 MTR LONG 200 KG PSC POLE |
| 123 | RCC BASE PLATE |
| 124 | EARTHING SUPPORT COIL TYPE |
| 125 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 126 | LT STAY SET COMPLETE |
| 127 | LT STAY INSULATOR |
| 128 | LT STAY CLAMP |
| 129 | 7/12 SWG STAY WIRE |
| 130 | (3X95+1X70+1X16)SQMM AB CABLE |
| 131 | 1X35+1X25 SQMM AB CABLE |
| 132 | POLE CLAMP FOR EYE HOOK (ON EXIXTING HT POLE 13 NOS +9 NOS NEW LT LINE WITH 8 MTR PSC POLE) |
| 133 | DEAD END CLAMP FOR EYE HOOK |
| 134 | SUSPENSION CLAMP WITH EYE HOOK |
| 135 | DANGER BOARD |
| 136 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 137 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 138 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 139 | GI NUTS BOLTS AND WASHERS |
| 140 | BLACK PAINT |
| 141 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 142 | SUNDRIES |
| 143 | 75X40X6 MM GI CHANNEL STRIGHT CROSS ARM 3 MTR LONG 2 NOS @ 6.8 KG/MTR FOR SP ROAD CROSSING GUARDING |
| 144 | NO-6,N0-8,NO-10 GI WIRE (DIA 4.8 MM) FOR GAURDING |
| 145 | 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG |
| 146 | 25X6 MM GI FLAT FOR EARTHING 1.2 KG/MTR |
| 147 | GI NUTS,BOLTS ,WASHER |
| 148 | EYE HOOK FOR CRADLE GUARD |
| 149 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 150 | CONCRETING OF 11 MTR WPB POLE IN RATIO 1:1.5:3 =0.45 CUM @ 6648.85 =0.45X6648.85=RS 2991.98 |
| 151 | CONCRETING OF 9/8 MTR PSC POLE IN RATIO 1:1.5:3 =0.375 CUM @ 6648.85 =0.375X6648.85=RS 2493.32 |
| 152 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 153 | MATERIALS FOR MASSIONARY WORK FOR EARTHPIT, CHARCOAL,SALT ETC INCLUDING CONSTRUCTION OF EARTHING CHAMBER (2\\"X2\\") & RCC SLAB COVER |
| 154 | CONSTRUCTION OF BOUNARY WALL BOUNDARY FOR FENCING OF DPM S/S IN THE SIZE OF 3X3 MTR @7300.12 /RM CONSIDERING HEIGHT ABOVE GROUND LEVEL-1.65 MTR & BELOW GROUND DEPTH 1.2 MTR INCLUDING THE COST OF FABRICATION INSTALLATION OF MS GATE (1.5X1.65) AS PER MAIL RECEIVED FROM NEP DEPT |
| 155 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 156 | DISMANTLING OF 9/11 MTR JOIST /WPB POLE 116X100 MM (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 157 | DIAMANTLING OF VARIOUS SIZE OF LT AB CABLE FROM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 158 | DIAMANTLING OF ACSR/AAA 34/55 SQMM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 159 | DISMANTLING OF EXISTING 11/0.4 KV ,33/0.4 KV THREE PHASE DISTRIBUTION TRANSFORMER BELOW 100 KVA INCLUDING REMOVAL OF HT/LT LEADS ,EARTH CONNECTIONS AND UNLOADING BY CRANE IF REQUIRED SCOPE OF WORK ALSO INCLUDES LOADING,TRANSPORTATION,UNLOADING AND STAKING AT A PROPER PLACE IN SAFE POSITION/SITE STORE. |
| 160 | DISMANTLE OF STEEL STRUCTURE LINES & SUBSTATION |
| 161 | DISMANTLING OF EXISTING 11/33 KV GO/AB SWITCH/ISOLATOR/DD FUSE/FUSE SET INCLUDING REMOVEL OF ALL ELECTRIC /EARTH CONNECTIONS LOADING,TRANSPORTATION,UNLOADING AND STAKING AT A PROPER PLACE IN SAFE POSITION/SITE STORE. |
| 162 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE |
| 163 | SURVEY & DIGITIZATION OF NEW DSS AND ITS INTERNALS INCLUDINGS ATTIBUTES |
| 164 | 9 MTR LOG 300 KG PSC POLE DUE TO ROAD CROSSING |
| 165 | RCC BASE PLATE |
| 166 | EARTHING SUPPORT COIL TYPE |
| 167 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 168 | 100X50X60MM GI CHANNEL FOR STRAIGHT CROSS ARM 1.4 MTR EACH 2 NOS EACH FOR CP ARRANGEMENT |
| 169 | 11 KV V CROSS ARM 10.2 KG EACH WITH GALVANIZATION |
| 170 | GI BACK CLAMP FOR V CROSS ARM |
| 171 | 11 KV F CLAMP 2.9 KG EACH WITH GALVANIZATION |
| 172 | 11 KV PIN INSULATOR POLYMER |
| 173 | 55 SQMM AAA CONDUCTOR |
| 174 | DISC INSULATOR (B&S) 45 KN POLYMER |
| 175 | H W FITTINGS B&S 2 BOLTED |
| 176 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 177 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 178 | HT STAY SET COMPLETE |
| 179 | HT STAY INSULATOR |
| 180 | HT STAY CLAMP (1.95 KG/PAIR) |
| 181 | 7/10 GI STAY WIRE |
| 182 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 183 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 184 | DANGER BOARD |
| 185 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 186 | GI NUTS BOLTS AND WASHERS |
| 187 | BLACK PAINT |
| 188 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 189 | SUNDRIES |
| 190 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE 300X300X12 |
| 191 | EARTHING OF SUPPORT (COIL TYPE) |
| 192 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 193 | 100X50X6 MM CHANNEL FOR STRAIGHT CROSS ARM 1.2 MTR EACH 16 NO & 0.2 MTR LONG 16 NO (4 CUT POINT) & (02 NO TAPPING POPINT ) @ 9.2 KG/MTR |
| 194 | 11 KV V CROSS ARM 10.2 KG EACH WITH GALVANIZATION |
| 195 | GI BACK CLAMP FOR 11 KV V CROSS ARM |
| 196 | 11 KV F CLAMP 2.9 KG EACH WITH GALVANIZATION |
| 197 | 11 KV PIN INSULATOR POLYMER |
| 198 | 55 SQMM AAA CONDUCTOR |
| 199 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 200 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 201 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 202 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 203 | HT STAY SET COMPLETE |
| 204 | HT STAY INSULATOR |
| 205 | HT STAY CLAMP(1.95 KG/MTR) |
| 206 | 7/10 SWG STAY WIRE |
| 207 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 208 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 209 | DANGER BOARD |
| 210 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 211 | GI NUTS BOLTS WASHERS |
| 212 | BLACK PAINT |
| 213 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 214 | SUNDRIES |
| 215 | 300 KG 9 MTR LONG PSC POLE |
| 216 | RCC BASE PLATE |
| 217 | EARTHING OF SUPPORT (COIL TYPE) |
| 218 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 219 | TOP PRESSURE CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 220 | TRANSFORMER MOUNTING GI CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 221 | AB SWITCH & HG FUSE MOUNTING GI CHANNEL 75X40X6 MM 2.8 MTR LONG 4 NOS @6.8 KG/MTR |
| 222 | CANTILEVER GI CHANNEL FOR SUPPORTING AB SWITCH ARM 75X40X6 MM 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 223 | CANTILEVER ANGLE FOR SUPPORTING AB SWITCH ARM 50X50X6 MM GI ANGLE 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 224 | TRANSFORMER BELTING GI ANGLE 50X50X6 MM 2.8 MTR LONG 2 NOS @4.5 KG/MTR WITH SIDE ANGLE TOTAL 7 MTR |
| 225 | ANGLE FOR MOUNTING LT DISTRIBUTION BOX 50X50X6 MM GI ANGLE 1 MTR EACH LONG 2 NOS @4.5 KG/MTR |
| 226 | AB SWITCH SIDE SUPPORT CHANNEL 100X50X6 MM 9.2 KG/MTR EACH CHANNEL LENGTH 0.35 MTR 2 NOS CHANNEL REQUIRED |
| 227 | CHANNEL SUPPORT FOR DOWN PIPE 75X40X6 MM 6.8 KG/MTR EACH CHANNEL LENGTH 0.8 MTR 1 NOS CHANNEL REQUIRED |
| 228 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 229 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 230 | 11 KV AB SWITCH 3 POLE (200 AMP) |
| 231 | 11 KV HG FUSE 3 POLE (200 AMP) |
| 232 | LIGHTNING ARRESTER(9 KV,5 KA) |
| 233 | HT STAY SET COMPLETE |
| 234 | HT STAY INSULATOR |
| 235 | HT STAY CLAMP(1.95 KG/MTR) |
| 236 | 7/10 SWG STAY WIRE |
| 237 | GI PIPE EARTHING 40 MM DIA MEDIUM GAUGE 3 MTRS LONG |
| 238 | 25X4 MM GI FLAT(NEUTRAL) |
| 239 | 25X6 MM GI FLAT |
| 240 | 55 SQMM AAAC |
| 241 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 242 | GI NUTS,BOLTS,WASHERS |
| 243 | 25 KVA 11/0.4 KV AL TRANSFORMER BIS ENERGY LEVEL -II |
| 244 | LT DISTRIBUTION BOX WITH MCCB, ALUMINIUM BUSBAR FOR SINGLE BAY WITH KITKAT FUSE FOR 25 KVA SUBSTATION |
| 245 | 1CX70 SQMM LT XLPE CABLE UN ARMOURED @ 10 MTR EACH |
| 246 | DANGER BOARD |
| 247 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 248 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 249 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 250 | BLACK PAINT |
| 251 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 252 | SUNDRIES |
| 253 | 300 KG 9 MTR LONG PSC POLE |
| 254 | 8 MTR LONG 200 KG PSC POLE |
| 255 | RCC BASE PLATE |
| 256 | EARTHING SUPPORT COIL TYPE |
| 257 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 258 | LT STAY SET COMPLETE |
| 259 | LT STAY INSULATOR |
| 260 | LT STAY CLAMP |
| 261 | 7/12 SWG STAY WIRE |
| 262 | 1X35+1X25 SQMM AB CABLE |
| 263 | POLE CLAMP FOR EYE HOOK |
| 264 | DEAD END CLAMP FOR EYE HOOK |
| 265 | SUSPENSION CLAMP WITH EYE HOOK |
| 266 | DANGER BOARD |
| 267 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 268 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 269 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 270 | GI NUTS BOLTS AND WASHERS |
| 271 | BLACK PAINT |
| 272 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 273 | SUNDRIES |
| 274 | 75X40X6 MM GI CHANNEL STRIGHT CROSS ARM 3 MTR LONG 2 NOS @ 6.8 KG/MTR FOR SP ROAD CROSSING GUARDING |
| 275 | NO-6,N0-8,NO-10 GI WIRE (DIA 4.8 MM) FOR GAURDING |
| 276 | 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG |
| 277 | 25X6 MM GI FLAT FOR EARTHING 1.2 KG/MTR |
| 278 | GI NUTS,BOLTS ,WASHER |
| 279 | EYE HOOK FOR CRADLE GUARD |
| 280 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 281 | CONCRETING OF 11 MTR WPB POLE IN RATIO 1:1.5:3 =0.45 CUM @ 6648.85 =0.45X6648.85=RS 2991.98 |
| 282 | CONCRETING OF 9/8 MTR PSC POLE IN RATIO 1:1.5:3 =0.375 CUM @ 6648.85 =0.375X6648.85=RS 2493.32 |
| 283 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 284 | MATERIALS FOR MASSIONARY WORK FOR EARTHPIT, CHARCOAL,SALT ETC INCLUDING CONSTRUCTION OF EARTHING CHAMBER (2\\"X2\\") & RCC SLAB COVER |
| 285 | CONSTRUCTION OF BOUNARY WALL BOUNDARY FOR FENCING OF DPM S/S IN THE SIZE OF 3X3 MTR @7300.12 /RM CONSIDERING HEIGHT ABOVE GROUND LEVEL-1.65 MTR & BELOW GROUND DEPTH 1.2 MTR INCLUDING THE COST OF FABRICATION INSTALLATION OF MS GATE (1.5X1.65) AS PER MAIL RECEIVED FROM NEP DEPT |
| 286 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 287 | DIAMANTLING OF VARIOUS SIZE OF LT AB CABLE FROM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 288 | DIAMANTLING OF ACSR/AAA 34/55 SQMM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 289 | DISMANTLING OF EXISTING 11/0.4 KV ,33/0.4 KV THREE PHASE DISTRIBUTION TRANSFORMER BELOW 100 KVA INCLUDING REMOVAL OF HT/LT LEADS ,EARTH CONNECTIONS AND UNLOADING BY CRANE IF REQUIRED SCOPE OF WORK ALSO INCLUDES LOADING,TRANSPORTATION,UNLOADING AND STAKING AT A PROPER PLACE IN SAFE POSITION/SITE STORE. |
| 290 | DISMANTLE OF STEEL STRUCTURE LINES & SUBSTATION |
| 291 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE |
| 292 | SURVEY & DIGITIZATION OF NEW DSS AND ITS INTERNALS INCLUDINGS ATTIBUTES |
| 293 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE 300X300X12 |
| 294 | EARTHING SUPPORT COIL TYPE |
| 295 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 296 | 100X50X60MM GI CHANNEL FOR STRAIGHT CROSS ARM 1.4 MTR EACH 3 NOS EACH ON PIN POINT POLE FOR CANTILEVER ARRANGEMENT & 6 NOS EACH FOR CP ARRANGEMENT ON CANTILEVER ARRANGEMENT |
| 297 | DISC INSULATOR (B&S) 45 KN POLYMER |
| 298 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 299 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 300 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 301 | 11 KV PIN INSULATOR POLYMER |
| 302 | 55 SQMM AAA CONDUCTOR |
| 303 | HT STAY SET COMPLETE |
| 304 | HT STAY INSULATOR |
| 305 | HT STAY CLAMP (1.95 KG/PAIR) |
| 306 | 7/10 GI STAY WIRE |
| 307 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 308 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 309 | DANGER BOARD |
| 310 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 311 | GI NUTS BOLTS AND WASHERS |
| 312 | BLACK PAINT |
| 313 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 314 | SUNDRIES |
| 315 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE 300X300X12 |
| 316 | EARTHING OF SUPPORT (COIL TYPE) |
| 317 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 318 | TOP PRESSURE CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 319 | TRANSFORMER MOUNTING GI CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 320 | AB SWITCH & HG FUSE MOUNTING GI CHANNEL 75X40X6 MM 2.8 MTR LONG 4 NOS @6.8 KG/MTR |
| 321 | CANTILEVER GI CHANNEL FOR SUPPORTING AB SWITCH ARM 75X40X6 MM 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 322 | CANTILEVER ANGLE FOR SUPPORTING AB SWITCH ARM 50X50X6 MM GI ANGLE 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 323 | TRANSFORMER BELTING GI ANGLE 50X50X6 MM 2.8 MTR LONG 2 NOS @4.5 KG/MTR WITH SIDE ANGLE TOTAL 7 MTR |
| 324 | ANGLE FOR MOUNTING LT DISTRIBUTION BOX 50X50X6 MM GI ANGLE 1 MTR EACH LONG 2 NOS @4.5 KG/MTR |
| 325 | AB SWITCH SIDE SUPPORT CHANNEL 100X50X6 MM 9.2 KG/MTR EACH CHANNEL LENGTH 0.35 MTR 2 NOS CHANNEL REQUIRED |
| 326 | CHANNEL SUPPORT FOR DOWN PIPE 75X40X6 MM 6.8 KG/MTR EACH CHANNEL LENGTH 0.8 MTR 1 NOS CHANNEL REQUIRED |
| 327 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 328 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 329 | 11 KV AB SWITCH 3 POLE (200 AMP) |
| 330 | 11 KV HG FUSE 3 POLE (200 AMP) |
| 331 | LIGHTNING ARRESTER(9 KV,5 KA) |
| 332 | HT STAY SET COMPLETE |
| 333 | HT STAY INSULATOR |
| 334 | HT STAY CLAMP(1.95 KG/MTR) |
| 335 | 7/10 SWG STAY WIRE |
| 336 | GI PIPE EARTHING 40 MM DIA MEDIUM GAUGE 3 MTRS LONG |
| 337 | 25X4 MM GI FLAT(NEUTRAL) |
| 338 | 25X6 MM GI FLAT |
| 339 | 55 SQMM AAAC |
| 340 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 341 | GI NUTS,BOLTS,WASHERS |
| 342 | 100 KVA 11/0.4 KV AL TRANSFORMER BIS ENERGY LEVEL -II |
| 343 | LT DISTRIBUTION BOX WITH MCCB, ALUMINIUM BUSBAR FOR 2 BAY WITH KITKAT FUSE FOR 100 KVA SUBSTATION |
| 344 | 1CX185 SQMM LT XLPE CABLE ARMOURED @ 15 MTR EACH |
| 345 | DANGER BOARD |
| 346 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 347 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 348 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 349 | BLACK PAINT |
| 350 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 351 | SUNDRIES |
| 352 | 10 MTR LONG 330 KG PSC POLE |
| 353 | RCC BASE PLATE |
| 354 | EARTHING SUPPORT COIL TYPE |
| 355 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 356 | LT STAY SET COMPLETE |
| 357 | LT STAY INSULATOR |
| 358 | LT STAY CLAMP |
| 359 | 7/12 SWG STAY WIRE |
| 360 | (3X50+1X35)SQMM AB CABLE |
| 361 | POLE CLAMP FOR EYE HOOK |
| 362 | DEAD END CLAMP FOR EYE HOOK |
| 363 | DANGER BOARD |
| 364 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 365 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 366 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 367 | GI NUTS BOLTS AND WASHERS |
| 368 | BLACK PAINT |
| 369 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 370 | SUNDRIES |
| 371 | 75X40X6 MM GI CHANNEL STRIGHT CROSS ARM 3 MTR LONG 2 NOS @ 6.8 KG/MTR FOR SP ROAD CROSSING GUARDING |
| 372 | NO-6,N0-8,NO-10 GI WIRE (DIA 4.8 MM) FOR GAURDING |
| 373 | 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG |
| 374 | 25X6 MM GI FLAT FOR EARTHING 1.2 KG/MTR |
| 375 | GI NUTS,BOLTS ,WASHER |
| 376 | EYE HOOK FOR CRADLE GUARD |
| 377 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 378 | CONCRETING OF 11 MTR WPB POLE IN RATIO 1:1.5:3 =0.45 CUM @ 6648.85 =0.45X6648.85=RS 2991.98 |
| 379 | CONCRETING OF 10 MTR PSC POLE IN RATIO 1:1.5:3 =0.415 CUM @ 6648.85 =0.415X6648.85=RS 3759.27 |
| 380 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 381 | MATERIALS FOR MASSIONARY WORK FOR EARTHPIT, CHARCOAL,SALT ETC INCLUDING CONSTRUCTION OF EARTHING CHAMBER (2\\"X2\\") & RCC SLAB COVER |
| 382 | CONSTRUCTION OF BOUNARY WALL BOUNDARY FOR FENCING OF DPM S/S IN THE SIZE OF 3X3 MTR @7300.12 /RM CONSIDERING HEIGHT ABOVE GROUND LEVEL-1.65 MTR & BELOW GROUND DEPTH 1.2 MTR INCLUDING THE COST OF FABRICATION INSTALLATION OF MS GATE (1.5X1.65) AS PER MAIL RECEIVED FROM NEP DEPT |
| 383 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 384 | DISMANTLING OF 9/11 MTR JOIST /WPB POLE 116X100 MM (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 385 | DIAMANTLING OF VARIOUS SIZE OF LT AB CABLE FROM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 386 | DIAMANTLING OF ACSR/AAA 34/55 SQMM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 387 | DISMANTLING OF EXISTING 11/0.4 KV ,33/0.4 KV THREE PHASE DISTRIBUTION TRANSFORMER BELOW 100 KVA INCLUDING REMOVAL OF HT/LT LEADS ,EARTH CONNECTIONS AND UNLOADING BY CRANE IF REQUIRED SCOPE OF WORK ALSO INCLUDES LOADING,TRANSPORTATION,UNLOADING AND STAKING AT A PROPER PLACE IN SAFE POSITION/SITE STORE. |
| 388 | DISMANTLE OF STEEL STRUCTURE LINES & SUBSTATION |
| 389 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE |
| 390 | SURVEY & DIGITIZATION OF NEW DSS AND ITS INTERNALS INCLUDINGS ATTIBUTES |
| 391 | 300 KG 9 MTR LONG PSC POLE |
| 392 | 8 MTR LONG 200 KG PSC POLE |
| 393 | RCC BASE PLATE |
| 394 | EARTHING SUPPORT COIL TYPE |
| 395 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 396 | LT STAY SET COMPLETE |
| 397 | LT STAY INSULATOR |
| 398 | LT STAY CLAMP |
| 399 | 7/12 SWG STAY WIRE |
| 400 | (1X35+1X25)SQMM AB CABLE |
| 401 | (3X35+1X25)SQMM AB CABLE |
| 402 | POLE CLAMP FOR EYE HOOK |
| 403 | DEAD END CLAMP FOR EYE HOOK |
| 404 | SUSPENSION CLAMP WITH EYEHOOK |
| 405 | DANGER BOARD |
| 406 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 407 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 408 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 409 | GI NUTS BOLTS AND WASHERS |
| 410 | BLACK PAINT |
| 411 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 412 | SUNDRIES |
| 413 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 414 | CONCRETING OF 9/8 MTR PSC POLE IN RATIO 1:1.5:3 =0.375 CUM @ 6648.85 =0.375X6648.85=RS 2493.32 |
| 415 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 416 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 417 | DIAMANTLING OF VARIOUS SIZE OF LT AB CABLE FROM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 418 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE |
| 419 | 300 KG 9 MTR LONG PSC POLE |
| 420 | RCC BASE PLATE |
| 421 | EARTHING SUPPORT COIL TYPE |
| 422 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 423 | 100X50X60MM GI CHANNEL FOR STRAIGHT CROSS ARM 1.2 MTR EACH 4 NOS FOR 1 NO CUT/TAPPING POINT |
| 424 | 11 KV V CROSS ARM 10.2 KG EACH WITH GALVANIZATION |
| 425 | GI BACK CLAMP FOR V CROSS ARM |
| 426 | 11 KV PIN INSULATOR POLYMER |
| 427 | 11 KV XLPE COVERED CONDUCTOR 55 SQMM AAA |
| 428 | DISC INSULATOR (B&S) 45 KN POLYMER |
| 429 | TENSION ASSEMBLY WEDGE TYPE WITH ANCHORING CLAMP FOR 11 KV COVERED CODUCTOR |
| 430 | IPC FOR COVERED CONDUCTOR 11 KV 55 SQMM |
| 431 | NON METALLIC TIES 11 KV FOR COVERED CONDUCTOR |
| 432 | MECHANICAL CONNECTOR WITH HEAT SHRINK SLEEVE FOR 11 KV 55 SQMM AAA COVEREC CONDUCTOR |
| 433 | HT STAY SET COMPLETE |
| 434 | HT STAY INSULATOR |
| 435 | HT STAY CLAMP (1.95 KG/PAIR) |
| 436 | 7/10 GI STAY WIRE |
| 437 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 438 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 439 | DANGER BOARD |
| 440 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 441 | GI NUTS BOLTS AND WASHERS |
| 442 | BLACK PAINT |
| 443 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 444 | SUNDRIES |
| 445 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE 300X300X12 |
| 446 | EARTHING OF SUPPORT (COIL TYPE) |
| 447 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 448 | TOP PRESSURE CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 449 | AB SWITCH MOUNTING GI CHANNEL 75X40X6 MM 2.8 MTR LONG 2 NOS @9.2 KG/MTR |
| 450 | AB SWITCH SIDE SUPPORT CHANNEL 100X50X6 MM 9.2 KG/MTR EACH CHANNEL LENGTH 0.35 MTR 2 NOS CHANNEL REQUIRED |
| 451 | CHANNEL SUPPORT FOR DOWN PIPE 75X40X6 MM 6.8 KG/MTR EACH CHANNEL LENGTH 0.8 MTR 1 NOS CHANNEL REQUIRED |
| 452 | GI CHANNEL FOR SUPPORTING DP ARM 75X40X6 MM 2.8 MTR LONG 2 NOS @ 6.8 KG/MTR |
| 453 | BRACING ANGLE 50X50X6 MM GI ANGLE 4 MTR LONG 2 NOS @4.5 KG/MTR |
| 454 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 455 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 456 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 457 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 458 | 11 KV PIN INSULATOR POLYMER |
| 459 | 11 KV AB SWITCH 3 POLE (400 AMP) |
| 460 | LIGHTNING ARRESTER(9 KV,10 KA) |
| 461 | HT STAY SET COMPLETE |
| 462 | HT STAY INSULATOR |
| 463 | HT STAY CLAMP(1.95 KG/MTR) |
| 464 | 7/10 SWG STAY WIRE |
| 465 | DANGER BOARD |
| 466 | GI BARBED WIRE ANTICLIMBING DEVICE 3 KG PER SUPPORT |
| 467 | GI PIPE EARTHING 40 MM DIA MEDIUM GAUGE 3 MTRS LONG |
| 468 | 50X6 MM GI FLAT FOR EARTHING ,2.36 KG/MTR 2.5 MTR FOR MESH FORMATION & 2.5 MTR FOR RAISING |
| 469 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 470 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 471 | GI NUTS,BOLTS,WASHERS |
| 472 | BLACK PAINT |
| 473 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 474 | SUNDRIES |
| 475 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE 300X300X12 |
| 476 | EARTHING OF SUPPORT (COIL TYPE) |
| 477 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 478 | TOP PRESSURE CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 479 | GI CHANNEL FOR SUPPORTING DP ARM 75X40X6 MM 2.8 MTR LONG 2 NOS @ 6.8 KG/MTR |
| 480 | BRACING ANGLE 50X50X6 MM GI ANGLE 4 MTR LONG 2 NOS @4.5 KG/MTR |
| 481 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 482 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 483 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 484 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 485 | 11 KV PIN INSULATOR POLYMER |
| 486 | HT STAY SET COMPLETE |
| 487 | HT STAY INSULATOR |
| 488 | HT STAY CLAMP(1.95 KG/MTR) |
| 489 | 7/10 SWG STAY WIRE |
| 490 | DANGER BOARD |
| 491 | GI BARBED WIRE ANTICLIMBING DEVICE 3 KG PER SUPPORT |
| 492 | GI PIPE EARTHING 40 MM DIA MEDIUM GAUGE 3 MTRS LONG |
| 493 | 50X6 MM GI FLAT FOR EARTHING ,2.36 KG/MTR 2.5 MTR FOR MESH FORMATION & 2.5 MTR FOR RAISING |
| 494 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 495 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 496 | GI NUTS,BOLTS,WASHERS |
| 497 | BLACK PAINT |
| 498 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 499 | SUNDRIES |
| 500 | 300 KG 9 MTR LONG PSC POLE |
| 501 | 10 MTR LONG 330 KG PSC POLE |
| 502 | RCC BASE PLATE |
| 503 | EARTHING OF SUPPORT (COIL TYPE) |
| 504 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 505 | 100X50X6 MM CHANNEL FOR STRAIGHT CROSS ARM 1.2 MTR EACH 16 NO & 0.2 MTR LONG 16 NO (4 CUT POINT) & (02 NO TAPPING POPINT ) @ 9.2 KG/MTR |
| 506 | 11 KV V CROSS ARM 10.2 KG EACH WITH GALVANIZATION |
| 507 | GI BACK CLAMP FOR 11 KV V CROSS ARM |
| 508 | 11 KV F CLAMP 2.9 KG EACH WITH GALVANIZATION |
| 509 | 11 KV PIN INSULATOR POLYMER |
| 510 | 55 SQMM AAA CONDUCTOR |
| 511 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 512 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 513 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 514 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 515 | HT STAY SET COMPLETE |
| 516 | HT STAY INSULATOR |
| 517 | HT STAY CLAMP(1.95 KG/MTR) |
| 518 | 7/10 SWG STAY WIRE |
| 519 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 520 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 521 | DANGER BOARD |
| 522 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 523 | GI NUTS BOLTS WASHERS |
| 524 | BLACK PAINT |
| 525 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 526 | SUNDRIES |
| 527 | 10 MTR LONG 330 KG PSC POLE |
| 528 | RCC BASE PLATE |
| 529 | EARTHING OF SUPPORT (COIL TYPE) |
| 530 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 531 | PRESSURE CHANNEL 100X50X6 MM EACH 1.2 MTR LONG 2 NOS (@9.2 KG/MTR) WITH GALVANIZATION |
| 532 | TRANSFORMER MOUNTING BRACKET 65X65X6 MM SUITABLE FOR 16KVA 11/0.23 KV TRANSFORMER EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 533 | AB SWITCH MOUNTING BRACKET 75x40x6 MM 6 MTR 6.8 KG /MTR |
| 534 | CANTILEVER GI CHANNEL FOR SUPPORTING AB SWITCH ARM 50X40X6 MM 3.5 MTR LONG 4.5 KG/MTR WITH GALVANIZATION |
| 535 | HORN GAP FUSE MOUNTING CHANNEL 75X40X6 MM 2.2 MTR 6.8 KG/MTR WITH GALVANIZATION |
| 536 | 11 KV DISC INSULATOR T&C TYPE 45KN POLYMER |
| 537 | HARD WARE FITTINGS T&C TYPE 45KN (2 BOLTED) |
| 538 | 11 KV AB SWITCH 2 POLE |
| 539 | 11 KV HG FUSE 2 POLE |
| 540 | LIGHTNING ARRESTER(9 KV,10 KA) |
| 541 | HT STAY SET COMPLETE |
| 542 | HT STAY INSULATOR |
| 543 | HT STAY CLAMP(1.95 KG/MTR) |
| 544 | 7/10 SWG STAY WIRE |
| 545 | GI PIPE EARTHING 40 MM DIA MEDIUM GAUGE 3 MTRS LONG |
| 546 | 25X4 MM GI FLAT(NEUTRAL) |
| 547 | 25X6 MM GI FLAT |
| 548 | 55 SQMM AAAC |
| 549 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 550 | GI NUTS,BOLTS,WASHERS |
| 551 | LT DISTRIBUTION BOX WITH MCCB, ALUMINIUM BUSBAR FOR SINGLE BAY WITH KITKAT FUSE FOR 16 KVA SUBSTATION |
| 552 | 2CX16 SQMM LT PVC CABLE UNARMOURED |
| 553 | DANGER BOARD |
| 554 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 555 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 556 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 557 | BLACK PAINT |
| 558 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 559 | SUNDRIES |
| 560 | 300 KG 9 MTR LONG PSC POLE |
| 561 | 8 MTR LONG 200 KG PSC POLE |
| 562 | RCC BASE PLATE |
| 563 | EARTHING SUPPORT COIL TYPE |
| 564 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 565 | LT STAY SET COMPLETE |
| 566 | LT STAY INSULATOR |
| 567 | LT STAY CLAMP |
| 568 | 7/12 SWG STAY WIRE |
| 569 | (1X35+1X25)SQMM XLPE AB CABLE |
| 570 | POLE CLAMP FOR EYE HOOK |
| 571 | DEAD END CLAMP FOR EYE HOOK |
| 572 | SUSPENSION CLAMP WITH EYE HOOK |
| 573 | DANGER BOARD |
| 574 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 575 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 576 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 577 | GI NUTS BOLTS AND WASHERS |
| 578 | BLACK PAINT |
| 579 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 580 | SUNDRIES |
| 581 | 75X40X6 mm GI CHANNEL STRIGHT CROSS ARM 1.5MTR LONG 04 NOS (@ 6.8 KG/MTR) FOR ROAD CROSSING GUARDING |
| 582 | 75X40X6 mm GI CHANNEL STRIGHT CROSS ARM 3.2MTR LONG 02 NOS (@ 6.8 KG/MTR) FOR DP ROAD CROSSING GUARDING |
| 583 | NO-6,N0-8,NO-10 GI WIRE (DIA 4.8 MM) FOR GAURDING |
| 584 | 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG |
| 585 | 25X6 MM GI FLAT FOR EARTHING 1.2 KG/MTR |
| 586 | GI NUTS,BOLTS ,WASHER |
| 587 | EYE HOOK FOR CRADLE GUARD |
| 588 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 589 | CONCRETING OF 11 MTR WPB POLE IN RATIO 1:1.5:3 =0.45 CUM @ 6648.85 =0.45X6648.85=RS 2991.98 |
| 590 | CONCRETING OF 10 MTR PSC POLE IN RATIO 1:1.5:3 =0.415 CUM @ 6648.85 =0.415X6648.85=RS 3759.27 |
| 591 | CONCRETING OF 9/8 MTR PSC POLE IN RATIO 1:1.5:3 =0.375 CUM @ 6648.85 =0.375X6648.85=RS 2493.32 |
| 592 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 593 | MATERIALS FOR MASSIONARY WORK FOR EARTHPIT, CHARCOAL,SALT ETC INCLUDING CONSTRUCTION OF EARTHING CHAMBER (2\\"X2\\") & RCC SLAB COVER |
| 594 | SUPPLY AND ERECTION OF GI FENCING WITH GATE AS PER STANDARD SPECIFICATION .PROVIDING & FIXING GALVANIZED STEEL CHAIN LINK FENCING WITH 75X75 MM MESH SIZE 4 MM DIA MESH WIRE CONFORMING TO IS:2721 , GI STRIPES WIRE 2.5 MM DIA WITH TYING WIRE 6 MM DIA MILD GI STEEL INCLUDING PROVIDING 25 MMX4.75 MM GI STRETCHER BARS EYE BOLTS STRAINERS, RING NUTS, HAIR PINS, STAPLES OF 3.5 MM WIRE, CLEATS OF GI ANGLE 75X60X6 MM , MS DROPPERS 25 MMX4.75 MM WITH 38 MM X4.85 MM HALF ROUND STAPLES. |
| 595 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 596 | DIAMANTLING OF VARIOUS SIZE OF LT AB CABLE FROM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 597 | DIAMANTLING OF ACSR/AAA 34/55 SQMM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 598 | DISMANTLING OF EXISTING 11/0.4 KV ,33/0.4 KV THREE PHASE DISTRIBUTION TRANSFORMER BELOW 100 KVA INCLUDING REMOVAL OF HT/LT LEADS ,EARTH CONNECTIONS AND UNLOADING BY CRANE IF REQUIRED SCOPE OF WORK ALSO INCLUDES LOADING,TRANSPORTATION,UNLOADING AND STAKING AT A PROPER PLACE IN SAFE POSITION/SITE STORE. |
| 599 | DISMANTLE OF STEEL STRUCTURE LINES & SUBSTATION |
| 600 | DISMANTLING OF 11/33 KV GO/AB SWITCH/ISOLATOR/DD FUSE/FUSE SET INCLUDING REMOVAL OF ALL ELECTRIC /EARTH CONNECTIONS/ LOADING , TGRANSPORTATION, UNLOADING AND STAKING AT A PROPER PLACE IN SAFE POSITION / BA SITE STORE |
| 601 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE |
| 602 | SURVEY & DIGITIZATION OF NEW DSS AND ITS INTERNALS INCLUDINGS ATTIBUTES |
| 603 | WPB 160X152 MM POLE 13 MTR LONG 30.44 KG/MTR |
| 604 | EARTHING SUPPORT COIL TYPE |
| 605 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 606 | TOP CHANNEL 100X50X6 MM 9.2 KG/MTR EACH CHANNEL LENGTH 3.5 MTR 2 NOS CHANNEL REQUIRED |
| 607 | DOUBLE POLE BELTING CHANNEL 75X40X6 MM 6.8 KG/MTR EACH CHANNEL LENGTH 3.5 MTR 4 NOS CHANNEL REQUIRED |
| 608 | 50X50X6 MM GI BRACING ANGLE 4.5 KG/MTR EACH ANGLE LENGTH 5.5 MTR 2 NOS ANGLE REQUIRED |
| 609 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .280 MTR LENGTH |
| 610 | GI NUTS BOLTS AND WASHERS OF DIFFERENT SIZE |
| 611 | DANGER BOARD |
| 612 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 613 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 614 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 615 | 148 SQMM AAA CONDUCTOR |
| 616 | 33 KV PIN INSULATOR POLYMER |
| 617 | HW FITTINGS (B&S) 120 KN 4 BOLT |
| 618 | DISC INSULATOR (B&S) 120 KN POLYMER |
| 619 | PG CLAMP FOR AAA CONDUCTOR |
| 620 | HT STAY CLAMP (1.95 KG/PAIR) |
| 621 | HT STAY SET COMPLETE |
| 622 | HT STAY INSULATOR |
| 623 | 7/8 GI STAY WIRE |
| 624 | LIGHTNING ARRESTER 30KV 10 KA STATION CLASS CLASS -2 |
| 625 | 40MM NOMINAL DIA BORE GI PIPE MEDIUM GAUGE EARTHING DEVICE WITH 3 MTR LONG |
| 626 | 25X6 MM GI FLAT FOR EARTHING |
| 627 | BLACK PAINT |
| 628 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 629 | SUNDRIES |
| 630 | WPB 160X152 (30.44 KG/MTR) 13 MTR WITH BASE PLATE 300X300X12 |
| 631 | EARTHING OF SUPPORT (COIL TYPE) |
| 632 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 633 | 33 KV V CROSS ARM GI 22 KG EACH |
| 634 | TOP BRACKET 100X50X6 MM GI CHANNEL 2 KG EACH |
| 635 | GI BACK CLAMP FOR 33 KV V CROSS ARM |
| 636 | 33 KV PIN INSULATOR POLYMER |
| 637 | GI NUTS BOLTS WASHER |
| 638 | DANGER BOARD |
| 639 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 640 | GI BARBED WIRE ANTICLIMBING DEVICE 3 KG PER SUPPORT |
| 641 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 642 | BLACK PAINT |
| 643 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 644 | SUNDRIES |
| 645 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE 300X300X12 |
| 646 | EARTHING OF SUPPORT (COIL TYPE) |
| 647 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 648 | 100X50X6 MM CHANNEL FOR STRAIGHT CROSS ARM 1.2 MTR EACH 16 NO & 0.2 MTR LONG 16 NO (4 CUT POINT) & (02 NO TAPPING POPINT ) @ 9.2 KG/MTR |
| 649 | 11 KV PIN INSULATOR POLYMER |
| 650 | 55 SQMM AAA CONDUCTOR |
| 651 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 652 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 653 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 654 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 655 | HT STAY SET COMPLETE |
| 656 | HT STAY INSULATOR |
| 657 | HT STAY CLAMP(1.95 KG/MTR) |
| 658 | 7/10 SWG STAY WIRE |
| 659 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 660 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 661 | DANGER BOARD |
| 662 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 663 | GI NUTS BOLTS WASHERS |
| 664 | BLACK PAINT |
| 665 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 666 | SUNDRIES |
| 667 | 300 KG 9 MTR LONG PSC POLE |
| 668 | 8 MTR LONG 200 KG PSC POLE |
| 669 | RCC BASE PLATE |
| 670 | EARTHING SUPPORT COIL TYPE |
| 671 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 672 | LT STAY SET COMPLETE |
| 673 | LT STAY INSULATOR |
| 674 | LT STAY CLAMP |
| 675 | 7/12 SWG STAY WIRE |
| 676 | (3X35+1X25)SQMM XLPE AB CABLE |
| 677 | POLE CLAMP FOR EYE HOOK |
| 678 | DEAD END CLAMP FOR EYE HOOK |
| 679 | SUSPENSION CLAMP WITH EYE HOOK |
| 680 | DANGER BOARD |
| 681 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 682 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 683 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 684 | GI NUTS BOLTS AND WASHERS |
| 685 | BLACK PAINT |
| 686 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 687 | SUNDRIES |
| 688 | 75X40X6 MM GI CHANNEL STRIGHT CROSS ARM 3 MTR LONG 2 NOS @ 6.8 KG/MTR FOR SP ROAD CROSSING GUARDING |
| 689 | NO-6,N0-8,NO-10 GI WIRE (DIA 4.8 MM) FOR GAURDING |
| 690 | 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG |
| 691 | 25X6 MM GI FLAT FOR EARTHING 1.2 KG/MTR |
| 692 | GI NUTS,BOLTS ,WASHER |
| 693 | EYE HOOK FOR CRADLE GUARD |
| 694 | GAURDING CROSS ARM 75X40X6 MM GI CHANNEL 3.5 MTR LONG 4 NOS FOR 33 KV LINE |
| 695 | NO-6,N0-8,NO-10 GI WIRE (DIA 4.8 MM) FOR GAURDING FOR 33 KV LINE |
| 696 | 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG FOR 33 KV LINE |
| 697 | 25X6 MM GI FLAT FOR EARTHING 1.2 KG/MTR FOR 33 KV LINE |
| 698 | GI NUTS,BOLTS ,WASHER FOR 33 KV LINE |
| 699 | EYE HOOK FOR CRADLE GUARD FOR 33 KV LINE |
| 700 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 701 | CONCRETING OF 13 MTR WPB POLE IN RATIO 1:1.5:3 =0.55 CUM @ 6648.85 =0.45X6648.85=RS 3656.87 |
| 702 | CONCRETING OF 11 MTR WPB POLE IN RATIO 1:1.5:3 =0.45 CUM @ 6648.85 =0.45X6648.85=RS 2991.98 |
| 703 | CONCRETING OF 9/8 MTR PSC POLE IN RATIO 1:1.5:3 =0.375 CUM @ 6648.85 =0.375X6648.85=RS 2493.32 |
| 704 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 705 | MATERIALS FOR MASSIONARY WORK FOR EARTHPIT, CHARCOAL,SALT ETC INCLUDING CONSTRUCTION OF EARTHING CHAMBER (2\\"X2\\") & RCC SLAB COVER |
| 706 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 707 | DISMANTLING OF 9/11 MTR JOIST /WPB POLE 116X100 MM (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 708 | DIAMANTLING OF VARIOUS SIZE OF LT AB CABLE FROM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 709 | DIAMANTLING OF ACSR/AAA 34/55 SQMM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 710 | DIAMANTLING OF ACSR/AAA80/100/148 SQMM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 711 | DISMANTLE OF STEEL STRUCTURE LINES & SUBSTATION |
| 712 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE |
| 713 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE 300X300X12 |
| 714 | EARTHING OF SUPPORT (COIL TYPE) |
| 715 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 716 | 100X50X6 MM CHANNEL FOR STRAIGHT CROSS ARM 1.2 MTR EACH 16 NO & 0.2 MTR LONG 16 NO (4 CUT POINT) & (02 NO TAPPING POPINT ) @ 9.2 KG/MTR |
| 717 | 11 KV PIN INSULATOR POLYMER |
| 718 | 55 SQMM AAA CONDUCTOR |
| 719 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 720 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 721 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 722 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 723 | HT STAY SET COMPLETE |
| 724 | HT STAY INSULATOR |
| 725 | HT STAY CLAMP(1.95 KG/MTR) |
| 726 | 7/10 SWG STAY WIRE |
| 727 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 728 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 729 | DANGER BOARD |
| 730 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 731 | GI NUTS BOLTS WASHERS |
| 732 | BLACK PAINT |
| 733 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 734 | SUNDRIES |
| 735 | 75X40X6 MM GI CHANNEL STRIGHT CROSS ARM 3 MTR LONG 2 NOS @ 6.8 KG/MTR FOR SP ROAD CROSSING GUARDING |
| 736 | NO-6,N0-8,NO-10 GI WIRE (DIA 4.8 MM) FOR GAURDING |
| 737 | 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG |
| 738 | 25X6 MM GI FLAT FOR EARTHING 1.2 KG/MTR |
| 739 | GI NUTS,BOLTS ,WASHER |
| 740 | EYE HOOK FOR CRADLE GUARD |
| 741 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 742 | CONCRETING OF 11 MTR WPB POLE IN RATIO 1:1.5:3 =0.45 CUM @ 6648.85 =0.45X6648.85=RS 2991.98 |
| 743 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 744 | MATERIALS FOR MASSIONARY WORK FOR EARTHPIT, CHARCOAL,SALT ETC INCLUDING CONSTRUCTION OF EARTHING CHAMBER (2\\"X2\\") & RCC SLAB COVER |
| 745 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 746 | DIAMANTLING OF ACSR/AAA 34/55 SQMM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 747 | DISMANTLE OF STEEL STRUCTURE LINES & SUBSTATION |
| 748 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE |
| 749 | 300 KG 9 MTR LONG PSC POLE |
| 750 | RCC BASE PLATE |
| 751 | EARTHING OF SUPPORT (COIL TYPE) |
| 752 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 753 | TOP PRESSURE CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 754 | TRANSFORMER MOUNTING GI CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 755 | AB SWITCH & HG FUSE MOUNTING GI CHANNEL 75X40X6 MM 2.8 MTR LONG 4 NOS @6.8 KG/MTR |
| 756 | CANTILEVER GI CHANNEL FOR SUPPORTING AB SWITCH ARM 75X40X6 MM 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 757 | CANTILEVER ANGLE FOR SUPPORTING AB SWITCH ARM 50X50X6 MM GI ANGLE 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 758 | TRANSFORMER BELTING GI ANGLE 50X50X6 MM 2.8 MTR LONG 2 NOS @4.5 KG/MTR WITH SIDE ANGLE TOTAL 7 MTR |
| 759 | ANGLE FOR MOUNTING LT DISTRIBUTION BOX 50X50X6 MM GI ANGLE 1 MTR EACH LONG 2 NOS @4.5 KG/MTR |
| 760 | AB SWITCH SIDE SUPPORT CHANNEL 100X50X6 MM 9.2 KG/MTR EACH CHANNEL LENGTH 0.35 MTR 2 NOS CHANNEL REQUIRED |
| 761 | CHANNEL SUPPORT FOR DOWN PIPE 75X40X6 MM 6.8 KG/MTR EACH CHANNEL LENGTH 0.8 MTR 1 NOS CHANNEL REQUIRED |
| 762 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 763 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 764 | 11 KV AB SWITCH 3 POLE (200 AMP) |
| 765 | 11 KV HG FUSE 3 POLE (200 AMP) |
| 766 | LIGHTNING ARRESTER(9 KV,5 KA) |
| 767 | HT STAY SET COMPLETE |
| 768 | HT STAY INSULATOR |
| 769 | HT STAY CLAMP(1.95 KG/MTR) |
| 770 | 7/10 SWG STAY WIRE |
| 771 | GI PIPE EARTHING 40 MM DIA MEDIUM GAUGE 3 MTRS LONG |
| 772 | 25X4 MM GI FLAT(NEUTRAL) |
| 773 | 25X6 MM GI FLAT |
| 774 | 55 SQMM AAAC |
| 775 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 776 | GI NUTS,BOLTS,WASHERS |
| 777 | 25 KVA 11/0.4 KV AL TRANSFORMER BIS ENERGY LEVEL -II |
| 778 | LT DISTRIBUTION BOX WITH MCCB, ALUMINIUM BUSBAR FOR SINGLE BAY WITH KITKAT FUSE FOR 25 KVA SUBSTATION |
| 779 | 1CX70 SQMM LT XLPE CABLE UN ARMOURED @ 10 MTR EACH |
| 780 | DANGER BOARD |
| 781 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 782 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 783 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 784 | BLACK PAINT |
| 785 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 786 | SUNDRIES |
| 787 | 300 KG 9 MTR LONG PSC POLE |
| 788 | RCC BASE PLATE |
| 789 | EARTHING OF SUPPORT (COIL TYPE) |
| 790 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 791 | 100X50X6 MM CHANNEL FOR STRAIGHT CROSS ARM 1.2 MTR EACH 16 NO & 0.2 MTR LONG 4NO (1 CUT POINT) & @ 9.2 KG/MTR |
| 792 | 11 KV V CROSS ARM 10.2 KG EACH WITH GALVANIZATION |
| 793 | GI BACK CLAMP FOR 11 KV V CROSS ARM |
| 794 | 11 KV F CLAMP 2.9 KG EACH WITH GALVANIZATION |
| 795 | 11 KV PIN INSULATOR POLYMER |
| 796 | 55 SQMM AAA CONDUCTOR |
| 797 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 798 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 799 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 800 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 801 | HT STAY SET COMPLETE |
| 802 | HT STAY INSULATOR |
| 803 | HT STAY CLAMP(1.95 KG/MTR) |
| 804 | 7/10 SWG STAY WIRE |
| 805 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 806 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 807 | DANGER BOARD |
| 808 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 809 | GI NUTS BOLTS WASHERS |
| 810 | BLACK PAINT |
| 811 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 812 | SUNDRIES |
| 813 | 75X40X6 MM GI CHANNEL STRIGHT CROSS ARM 3 MTR LONG 2 NOS @ 6.8 KG/MTR FOR SP ROAD CROSSING GUARDING |
| 814 | NO-6,N0-8,NO-10 GI WIRE (DIA 4.8 MM) FOR GAURDING |
| 815 | 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG |
| 816 | 25X6 MM GI FLAT FOR EARTHING 1.2 KG/MTR |
| 817 | GI NUTS,BOLTS ,WASHER |
| 818 | EYE HOOK FOR CRADLE GUARD |
| 819 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 820 | CONCRETING OF 9/8 MTR PSC POLE IN RATIO 1:1.5:3 =0.375 CUM @ 6648.85 =0.375X6648.85=RS 2493.32 |
| 821 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 822 | MATERIALS FOR MASSIONARY WORK FOR EARTHPIT, CHARCOAL,SALT ETC INCLUDING CONSTRUCTION OF EARTHING CHAMBER (2\\"X2\\") & RCC SLAB COVER |
| 823 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 824 | DIAMANTLING OF ACSR/AAA 34/55 SQMM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 825 | DISMANTLING OF EXISTING 11/0.4 KV ,33/0.4 KV THREE PHASE DISTRIBUTION TRANSFORMER BELOW 100 KVA INCLUDING REMOVAL OF HT/LT LEADS ,EARTH CONNECTIONS AND UNLOADING BY CRANE IF REQUIRED SCOPE OF WORK ALSO INCLUDES LOADING,TRANSPORTATION,UNLOADING AND STAKING AT A PROPER PLACE IN SAFE POSITION/SITE STORE. |
| 826 | DISMANTLE OF STEEL STRUCTURE LINES & SUBSTATION |
| 827 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE |
| 828 | SURVEY & DIGITIZATION OF NEW DSS AND ITS INTERNALS INCLUDINGS ATTIBUTES |
| 829 | 300 KG 9 MTR LONG PSC POLE |
| 830 | RCC BASE PLATE |
| 831 | EARTHING OF SUPPORT (COIL TYPE) |
| 832 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 833 | TOP PRESSURE CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 834 | TRANSFORMER MOUNTING GI CHANNEL 100X50X6 MM EACH 2.8 MTR LONG 2 NOS (@9.2 KG/MTR) |
| 835 | AB SWITCH & HG FUSE MOUNTING GI CHANNEL 75X40X6 MM 2.8 MTR LONG 4 NOS @6.8 KG/MTR |
| 836 | CANTILEVER GI CHANNEL FOR SUPPORTING AB SWITCH ARM 75X40X6 MM 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 837 | CANTILEVER ANGLE FOR SUPPORTING AB SWITCH ARM 50X50X6 MM GI ANGLE 1 MTR LONG 2 NOS 6.8 KG/MTR |
| 838 | TRANSFORMER BELTING GI ANGLE 50X50X6 MM 2.8 MTR LONG 2 NOS @4.5 KG/MTR WITH SIDE ANGLE TOTAL 7 MTR |
| 839 | ANGLE FOR MOUNTING LT DISTRIBUTION BOX 50X50X6 MM GI ANGLE 1 MTR EACH LONG 2 NOS @4.5 KG/MTR |
| 840 | AB SWITCH SIDE SUPPORT CHANNEL 100X50X6 MM 9.2 KG/MTR EACH CHANNEL LENGTH 0.35 MTR 2 NOS CHANNEL REQUIRED |
| 841 | CHANNEL SUPPORT FOR DOWN PIPE 75X40X6 MM 6.8 KG/MTR EACH CHANNEL LENGTH 0.8 MTR 1 NOS CHANNEL REQUIRED |
| 842 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 843 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 844 | 11 KV AB SWITCH 3 POLE (200 AMP) |
| 845 | 11 KV HG FUSE 3 POLE (200 AMP) |
| 846 | LIGHTNING ARRESTER(9 KV,5 KA) |
| 847 | HT STAY SET COMPLETE |
| 848 | HT STAY INSULATOR |
| 849 | HT STAY CLAMP(1.95 KG/MTR) |
| 850 | 7/10 SWG STAY WIRE |
| 851 | GI PIPE EARTHING 40 MM DIA MEDIUM GAUGE 3 MTRS LONG |
| 852 | 25X4 MM GI FLAT(NEUTRAL) |
| 853 | 25X6 MM GI FLAT |
| 854 | 55 SQMM AAAC |
| 855 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 856 | GI NUTS,BOLTS,WASHERS |
| 857 | 25 KVA 11/0.4 KV AL TRANSFORMER BIS ENERGY LEVEL -II |
| 858 | LT DISTRIBUTION BOX WITH MCCB, ALUMINIUM BUSBAR FOR SINGLE BAY WITH KITKAT FUSE FOR 25 KVA SUBSTATION |
| 859 | 1CX70 SQMM LT XLPE CABLE UN ARMOURED @ 10 MTR EACH |
| 860 | DANGER BOARD |
| 861 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 862 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 863 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 864 | BLACK PAINT |
| 865 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 866 | SUNDRIES |
| 867 | 300 KG 9 MTR LONG PSC POLE |
| 868 | 8 MTR LONG 200 KG PSC POLE |
| 869 | RCC BASE PLATE |
| 870 | EARTHING SUPPORT COIL TYPE |
| 871 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 872 | LT STAY SET COMPLETE |
| 873 | LT STAY INSULATOR |
| 874 | LT STAY CLAMP |
| 875 | 7/12 SWG STAY WIRE |
| 876 | (1X35+1X25)SQMM XLPE AB CABLE |
| 877 | (3X35+1X25) SQMM LT XLPE AB CABLE |
| 878 | POLE CLAMP FOR EYE HOOK |
| 879 | DEAD END CLAMP FOR EYE HOOK |
| 880 | SUSPENSION CLAMP WITH EYE HOOK |
| 881 | DANGER BOARD |
| 882 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 883 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 884 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 885 | GI NUTS BOLTS AND WASHERS |
| 886 | BLACK PAINT |
| 887 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 888 | SUNDRIES |
| 889 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 890 | CONCRETING OF 9/8 MTR PSC POLE IN RATIO 1:1.5:3 =0.375 CUM @ 6648.85 =0.375X6648.85=RS 2493.32 |
| 891 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 892 | MATERIALS FOR MASSIONARY WORK FOR EARTHPIT, CHARCOAL,SALT ETC INCLUDING CONSTRUCTION OF EARTHING CHAMBER (2\\"X2\\") & RCC SLAB COVER |
| 893 | CONSTRUCTION OF BOUNDARY WALL FOR FENCING OF DPM S/S IN THE SIZE OF 3X3 MTR @7300.12/RM CONSIDERING HEIGHT ABOVE GROUND LEVEL-1.65 MTR & BELOW GROUND DEPTH 1.2 MTR INCLUDING THE COST OF FABRICATION INSTALLATION OF MS GATE(1.5X1.65) MTR |
| 894 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 895 | DISMANTLING OF EXISTING 11/0.4 KV ,33/0.4 KV THREE PHASE DISTRIBUTION TRANSFORMER BELOW 100 KVA INCLUDING REMOVAL OF HT/LT LEADS ,EARTH CONNECTIONS AND UNLOADING BY CRANE IF REQUIRED SCOPE OF WORK ALSO INCLUDES LOADING,TRANSPORTATION,UNLOADING AND STAKING AT A PROPER PLACE IN SAFE POSITION/SITE STORE. |
| 896 | DISMANTLE OF STEEL STRUCTURE LINES & SUBSTATION |
| 897 | DIAMANTLING OF VARIOUS SIZE OF LT AB CABLE FROM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 898 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE |
| 899 | WPB 160X152 (30.44 KG/MTR) 11 MTR WITH BASE PLATE 300X300X12 |
| 900 | EARTHING OF SUPPORT (COIL TYPE) |
| 901 | NO-8 GI WIRE DIA 4.6 MM 0.131KG/MTR - 2MTR EACH POLE CONNECTING POLE WITH EARTHING |
| 902 | 100X50X6 MM CHANNEL FOR STRAIGHT CROSS ARM 1.2 MTR EACH 16 NO & 0.2 MTR LONG 4NO (1 CUT POINT) & @ 9.2 KG/MTR |
| 903 | 11 KV V CROSS ARM 10.2 KG EACH WITH GALVANIZATION |
| 904 | GI BACK CLAMP FOR 11 KV V CROSS ARM |
| 905 | 11 KV F CLAMP 2.9 KG EACH WITH GALVANIZATION |
| 906 | 11 KV PIN INSULATOR POLYMER |
| 907 | 55 SQMM AAA CONDUCTOR |
| 908 | 11 KV DISC INSULATOR B&S TYPE 45KN POLYMER |
| 909 | HARD WARE FITTINGS B&S TYPE 45KN (2 BOLTED) |
| 910 | PG CLAMP FOR 55 SQMM AAA CONDUCTOR |
| 911 | FISH PLATE 50X8 MM 3.14 KG/MTR EACH .28 MTR LENGTH |
| 912 | HT STAY SET COMPLETE |
| 913 | HT STAY INSULATOR |
| 914 | HT STAY CLAMP(1.95 KG/MTR) |
| 915 | 7/10 SWG STAY WIRE |
| 916 | GI BARBED WIRE ANTICLIMBING DEVICE |
| 917 | BACK CLAMP FOR BARBED WIRE ANTICLIMBING DEVICE 25X3 MM FLAT 0.59 KG/MTR FLAT OF 0.510 MTR LENGTH |
| 918 | DANGER BOARD |
| 919 | BACK CLAMP FOR DANGER PLATE 25X3 MM FLAT, 0.59 KG/MTR FLAT OF 0.510 MTR |
| 920 | GI NUTS BOLTS WASHERS |
| 921 | BLACK PAINT |
| 922 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 923 | SUNDRIES |
| 924 | 300 KG 9 MTR LONG PSC POLE |
| 925 | 8 MTR LONG 200 KG PSC POLE |
| 926 | RCC BASE PLATE |
| 927 | EARTHING SUPPORT COIL TYPE |
| 928 | NO-8 GI WIRE (DIA 4.6MM) 0.131 KG/MTR 2 MTR FOR CONNECTING POLE WITH COIL EARTHING |
| 929 | LT STAY SET COMPLETE |
| 930 | LT STAY INSULATOR |
| 931 | LT STAY CLAMP |
| 932 | 7/12 SWG STAY WIRE |
| 933 | (1X35+1X25)SQMM XLPE AB CABLE |
| 934 | POLE CLAMP FOR EYE HOOK |
| 935 | DEAD END CLAMP FOR EYE HOOK |
| 936 | SUSPENSION CLAMP WITH EYE HOOK |
| 937 | DANGER BOARD |
| 938 | BACK CLAMP FOR DANGER BOARD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 939 | ANTICLIMBING DEVICE (GI BARBED WIRE 3 KG PER SUPPORT) |
| 940 | BACK CLAMP FOR ACD (25X3 MM GI EARTH FLAT 0.59 KG/MTR & 0.51 MTR FOR EACH BACK CLAMP) |
| 941 | GI NUTS BOLTS AND WASHERS |
| 942 | BLACK PAINT |
| 943 | YELLOW COLOUR PAINT FOR BACKGROUND |
| 944 | SUNDRIES |
| 945 | 75X40X6 MM GI CHANNEL STRIGHT CROSS ARM 3 MTR LONG 2 NOS @ 6.8 KG/MTR FOR SP ROAD CROSSING GUARDING |
| 946 | NO-6,N0-8,NO-10 GI WIRE (DIA 4.8 MM) FOR GAURDING |
| 947 | 40 MM NOMINAL BORE GI PIPE (MEDIUM GAUGE) EARTHING DEVICE WITH 3 MTR LONG |
| 948 | 25X6 MM GI FLAT FOR EARTHING 1.2 KG/MTR |
| 949 | GI NUTS,BOLTS ,WASHER |
| 950 | EYE HOOK FOR CRADLE GUARD |
| 951 | STAY CONCRETING IN RATIO 1:2:4 AS PER TPSODL SPECIFICATION AND DRAWING =0.2 CUM @6500 |
| 952 | CONCRETING OF 11 MTR WPB POLE IN RATIO 1:1.5:3 =0.45 CUM @ 6648.85 =0.45X6648.85=RS 2991.98 |
| 953 | CONCRETING OF 9/8 MTR PSC POLE IN RATIO 1:1.5:3 =0.375 CUM @ 6648.85 =0.375X6648.85=RS 2493.32 |
| 954 | COUPING OF POLES IN RATI 1:1.5:3=0.1125 CUM @6648.85 =0.1125X6648.85=RS 748.00 |
| 955 | MATERIALS FOR MASSIONARY WORK FOR EARTHPIT, CHARCOAL,SALT ETC INCLUDING CONSTRUCTION OF EARTHING CHAMBER (2\\"X2\\") & RCC SLAB COVER |
| 956 | DISMANTLING OF 9/8 MTR PSC POLE (SERVICABLE POLE AFTER DIGGING THE PIT AND TAKING OUT THE POLE ,TRANSPORTATION AND STACKING THE POLE AT A PROPER PLACE IN SAFE POSITION WITH IN 10 KM /SITE STORE AND REFILLING THE PIT WITH LOOSE EARTH AND RAMMING INCLUDING REMOVAL AND DISPOSAL OF MALBA AT PROPER LOCATION AS PER INSTRUCTION OF EIC |
| 957 | DIAMANTLING OF ACSR/AAA 34/55 SQMM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 958 | DISMANTLE OF STEEL STRUCTURE LINES & SUBSTATION |
| 959 | DIAMANTLING OF VARIOUS SIZE OF LT AB CABLE FROM OVER HEAD LINE ,RECOILING,LOADING TRANSPORTATION,UNLOADING AND STAKING AT PROPER PLACE IN SAFE POSITION/BA SITE STORE |
| 960 | SURVEY OF INCREMENTAL/DELTA NETWORK AND ASSETS CHANGES OF 11 KV & LT NETWORK AND UPDATION IN GESW DATABASE.N:B:. Salvage Value @ 8% to be deducted from the Contractor's Bill. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail