| 1 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as specified. |
| 2 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sq.m on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 3 | Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in hard/ dense soil complete all as specified and as directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm. Soft/loose soil. |
| 5 | Removing excavated material not exceeding 50 m and depositing where directed at a level n exc. 1.5m above the starting poin soft/loose soil complete all as specified and as directed. |
| 6 | M&L Cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 7 | M&L Providing cement concrete in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 4028, water troughs and the like including weathering, slightly rounded or chamfered angle and throating, as directed type B0 1:2:4(12.5 mm graded aggregate) including necessary formwork complete all as specified and as directed. |
| 8 | Material and labour for RCC Design mix M25 (using 20 mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams ,plinth beam ,bases for column; basement slabs, complete all as specified and as directed. |
| 9 | Material and labour for RCC Design mix M25 (using 20 mm graded crushed stone aggregate) as Slabs supported on walls, beams and columns, in floors, roofs, landing balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 10 | Material and labour for RCC Design mix M25 (using 20 mm graded crushed stone aggregate) as Beams, Cantilever,Lintel above 1.5m complete all as specified and as directed. |
| 11 | Material and labour for RCC Design mix M25 (using 20 mm graded crushed stone aggregate) as in Columns, pillars, piers posts and struts complete all as specified and as directed. |
| 12 | Material and labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape reqired including cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips |
| 13 | Material and labour for Mild steel TMT bars 8 mm dia , cut to length, bent to shape reqired including cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips . |
| 14 | M&L Brick work with sub class B brick straight or curved on plan not exceeding 6m mean radius , built in cement mortar 1:6 complete all as specified and as directed. |
| 15 | M&L Brick work with sub class B brick in half brick wall , built in cm 1:4 complete all as specified and as directed. |
| 16 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. Rough finished surfaces of concrete flat. |
| 17 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mmthick (Horizontal or sloping) Rough finished surfaces of concrete flat complete all as specified and as directed. |
| 18 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilivers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Rough finished surfaces of concrete flat complete all as specified and as directed. |
| 19 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions Rough finished surfaces of concrete flat complete all as specified and as directed. |
| 20 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide flat complete all as specified and as directed. |
| 21 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 22 | Supply and fixed factory made solid panel PVC door shutler 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered WiUl hea moulded plain colour PVC 'C' chrume having a PVC sheet sh'ip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side & as gap insert for top rail & bottom rail Panelling of plain colour PVC sheet to be fitted in the M.S. fraine welded / sealed to the stiles & rails with suitable PVC shee beading, and joined together with solven cement, suppling & fixing in the frame a site as per specification & drawing complete all as specified and as directed. |
| 23 | S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed. |
| 24 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed. |
| 25 | S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 26 | S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed. |
| 27 | Supply and fixed Butt Hinges 100 mm long, mild steel and fixed complete all as specified and as directed. |
| 28 | Supply & fix sheet glass, selected quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 29 | M & L for cement concrete 1:4:8, type D-2 (using 40 mm nominal size graded crushed stone aggregate) 75 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. |
| 30 | M & L for cement concrete 1:2:4 type B-1 (using 20 mm nominal size graded crushed stone aggregate) as in floor 40 mm thick finished even and smooth using extra cement complete all as specified and directed. |
| 31 | M & L for cement concrete 1:2:4 type B-0 (using 12.5 mm nominal size graded crushed stone aggregate) as in floor 25 mm thick finished even and smooth using extra cement complete all as specified and directed. |
| 32 | Material and labour for 75 mm thick cement concrete, 1:3:6, type C-2 (40 mm graded crushed stone aggregate) as in plinth protection/ subbase/ flooring including necessary formwork complete all as specified and as directed. |
| 33 | Material and labour for Non - skid Ceramic white tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement to match existing surface including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 34 | M&L Glazed ceramic tiles in vertical surface of size 450 mm x 300 mm x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the existing surface including 10 mm thick backing coat in cement mortar 1:6 comlete all as specified and as directed. |
| 35 | Material and labour for 10 mm thick rendering on fair faces of brick work or concrete in cement mortar 1:6 finished the surface even and smooth without using extra cement complete all as specified and as directed. |
| 36 | Material and labour for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces in two layer (10 mm + 5 mm ) top coat mix with WPC as per manufacturer instruction finished the surface even and smooth without using extra cement complete all as specified and as directed. Note:- WPC shall be measured and paid separatly. |
| 37 | Material and labour for 5 mm thick rendering in cement mortar 1:3 as on concrete surfaces of ceiling of roof , chajja as in ceiling finished the surface even and smooth without ussing extra cement complete all as specified and as directed. |
| 38 | M&L for preparing the new plastered surfaces and applying two coats of oil bound distemper over a coat Primer on Ceiling complete all as specified and direcrted. |
| 39 | M&L for preparing the new plastered surfaces and applying two coats of cement base paint on walls complete all as specified and directed. |
| 40 | M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed |
| 41 | Supply only liquid water proofing compound confirming to IS 2645: 2003 complete all as specified and as directed. |
| 42 | M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and providing 10 mm thick cement plaster in CM (1:4) using water proofing compound @ 3 % by weight of cement for filling depression if any to receive water proofing treatment and providing APP modified bituminous membrane water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.6 kg/sqm ± 5% per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/Sqm by the same membrane manufacture of density at 25 C, 0.87-0.89 kg/litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane torch application method overlap while torching shall be 75 mm on length and 100 mm width side, all angles & bituminous should sealed with extra care to ensure full bondage all joints including for applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed by Engineer-In-charge (Note : WPC shall be measured and paid separately) |
| 43 | S&F 20 mm Gun-metal globe or gate valves, with iron wheel headt screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 44 | S&F 25 mm Gun-metal globe or gate valves, with iron wheel headt screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 45 | S&F 20 mm Ball brass valves. high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 46 | S&F 25 mm Ball brass valves. high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed. |
| 47 | Supply and fixed PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 48 | Supply and fixed PVC (SWR) pipes 75 mm, single socketed, with rubber ring joints fixed to walls complete all as specified and as directed. |
| 49 | Supply and fixed PVC (SWR) floor trap 75mm, plain with grating includ ing jointing with solvent cement complete all as specified and as directed. |
| 50 | S & F wash basins, vitreous china, white, flat back, size 580 mm X 450 mm (for hospital use) with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed. |
| 51 | S & F vitreous china urinals, bowl (angle back) without flushing rim of size 450 mm X 350 mm X 275 mm with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed. |
| 52 | S&F Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified. |
| 53 | S & F vitreous china squatting pan, 'Orissa\\" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 54 | S & F 10 litres cap PVC, valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete. |
| 55 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 56 | S & F stainless steel soap dish weight not less than 150 gm each fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 57 | S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 1000 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes all as specified and as directed. |
| 58 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 59 | M & L for hardcore (broken stone or boulders) of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed. |
| 60 | Supplying and laying ,16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 61 | Supplying and laying 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 62 | Cutting chases, pinning in brick work making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth |
| 63 | S&F bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified and directed |
| 64 | S&F bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 20 mm bore and fixed complete all as specified and directed |
| 65 | S&F Pillar taps 15mm, cast copper alloy, with capstan heads, chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed complete all as specified and directed |
| 66 | S&F 15 mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed but fancy type, chromium plated |
| 67 | M & L for chequered cement concrete tiles, cast in rubber mould, glossy finish of approved colour, general purpose, double layer, size 30 cm X 30 cm X 25 mm thick, with mixture of white and grey cement in equal proportions and pigments, set, jointed and pointed in neat cement slurry in floor including laying over 20 mm thick bedding of cement mortar 1:6 complete all as specified and as directed. |
| 68 | M&L for 32 mm bore low density polythelene pipes (LDPE) with fittings of pressure rating 6 Kgf / Sqcm fixed to walls or in floors etc complete all as specified and directed. |
| 69 | Supply and fixed PVC connections 15 mm size with PTMT nuts of length 450mm fixed complete all as specified and directed. |
| 70 | Supply and fixed PVC (SWR) branch piece double (double y) equal unequal suitable for PVC SWR of pipe 75mm dia complete all as specified and directed |
| 71 | S&F PVC (SWR) branch piece single (single y) equal unequal suitable for PVC SWR of pipe 110 mm dia complete all as specified and directed |
| 72 | S&F PVC (SWR) Junction single (single T) equal unequal suitable for PVC SWR of pipe 75mm dia complete all as specified and directed |
| 73 | S&F PVC (SWR) Junction single (single T) equal unequal suitable for PVC SWR of pipe 110 mm dia complete all as specified and directed |
| 74 | S&F 110 mm dia PVC (SWR) vent cowl complete all as specified and as directed. |
| 75 | Supply and fixeed 75mm PVC (SWR) vent cowl complete all as specified and as directed. |
| 76 | S&F 75mm PVC (SWR) bends any radius complete all as specified and as directed. |
| 77 | S&F 110mm PVC (SWR) WC connector bent type complete all as specified and as directed. |
| 78 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil for foundation etc or for shaft, wells, manholes etc complete all as specified and directed. |
| 79 | M&L Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortar 1:4 complete all as specified and as directed. |
| 80 | M&L Loose filling with Broken bricks of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed. |
| 81 | M&L for rendering 15 mm thick in cement mortar 1:4 on brick work or concrete surface of walls finished even and smooth without using extra cement complete all as specified and directed. |
| 82 | M&L pre cast RCC (1:2:4) type B1 using 20 mm graded stone aggregates for cover slab of manhole/soak pit etc set in cement mortar 1:4 complete all as specified and as directed by Engr-in-Charge. |
| 83 | M & L for concrete bed to drain pipes of internal diameter 150 mm, in cement concrete 1:3:6, type C-2 (using 40 mm nominal size graded crushed stone aggregate) including packing under and haunching against the sides of pipes complete all as specified and as directed. |
| 84 | S&F Reinforced concrete pipes 150mm , class NP3, laid and jointed complete with collars complete all as specified and directed. |
| 85 | M & L for Conventional type LLDPE septic Tank designed to carry sweage and sullage water, excation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 10 Users complete all as specified and directed. |
| 86 | M & L for Machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and grainite finish polishing inclding 20mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 87 | M&L for Machine cut Pre polished Kota stone slab flooring 15-18mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and grainite finish polishing as in risers of steps, skirting, dado etc including 10 mm thick backing coat in cement mortar 1:3 complete all as specified and as directed. |
| 88 | M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and as directed. |
| 89 | Excavation in post holes (or similar holes) each n. exc 0.5 cu.m, getting out, returning filling in and well ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n exc 50 m and making good surface in any type of soil complete all as specified |
| 90 | M&L for cement concrete 1:2:4 type B-2 (40 mm graded aggre-gate) as in foundation filling and mass concrete complete all as specified and as directed. |
| 91 | Material and labour for steel work of grade-3 as per IS 10748 in tubular trusses including special shaped washer etc. complete using ERW or HRIW welded tubes conforming to IS 1161: 2014 (Yst 240 Grade) complete all as specified and directed. |
| 92 | S & F hot rolled medium and high tensile structural steel of Fe-290 (Gde E 165 conforming to IS 2062: 2011 as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed. |
| 93 | S & F hot rolled medium and high tensile structural steel of grade E 250 quality A conforming to IS 2062: 2011 as in rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed. |
| 94 | S & F mild steel screw bolts (machine made), diameter of neck 11 to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10 cm but not exceeding 15 cm long complete all as specified and as directed. |
| 95 | S & F hot rolled medium and high tensile structural steel of grade E165, Fe-290 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. |
| 96 | S & F expanded metal not exceeding 4 Kg per square metre, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified and as directed. |
| 97 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed |
| 98 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 99 | M&L for preparation of new or previously untreated steel surfaces of any description over 10 Cm width and girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer |
| 100 | Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 101 | Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 102 | S&F sinks made of stainless steel sink of size overall size 495mm x 420mm and bowl size 410mm x 330mm x 160mm made up with 1mm thick SS-304 grade steel with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, complete all as specifiedand as directed. |
| 103 | S & F grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and as directed. |
| 104 | M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLHS in and in PVC casing & caping of suitable size duty ISI marked with all necessary fittings for mounting of modular switches/sockets including 1.5 sq mm FRLHS PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light/ceiling fan/exhaust fan controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 complete all as specified and directed by Engr- in-charge. |
| 105 | All as per item No. 1 above but 3 pin 5 amps socket out let point with the same board with other switches with cables of 1.5 Sqmm size complete all as specified and directed. |
| 106 | S/F sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls complete for 4 modules complete all as specified and directed. |
| 107 | -do- all as per item No 04 above but for 6 modules complete all as specified and directed. |
| 108 | S/F ceiling rose, 3 ph plastic round PVC/polycarbonate isolated body for mounting ceiling fan/exhaust fan/light fittings complete all as specified and directed. |
| 109 | S/F modular cover plate with frame for fixing of modular switches/sockets for 4 modules complete all as specified and directed. |
| 110 | -do- all as per item No. 07 above but for 6 modules complete all as specified and directed. |
| 111 | S/F switch piano modular flush type 5/6 Amps 230V AC complete one way complete all as specified and directed. |
| 112 | S&F modular socket 6A out let 2/3 pin 5 Amps flush type complete all as specified and directed. |
| 113 | S & F surface and wall mounted LED batten 4feets with 1x20W indoor decorative luminaries with and including electronic driver and 1x20W LED lamp,pre wired including necessary electric connection copper flexible PVC cable of 0.5 sqmm 3 core not more than 1m in length from ceiling rose to light fittings complete all as specified and directed. |
| 114 | S & F surface and wall mounted LED batten 2 feets with 1x10W indoor decorative luminaries with and including electronic driver and 1x10W LED lamp,pre wired including necessary electric connection copper flexible PVC cable of 0.5 sqmm 3 core not more than 1m in length from ceiling rose to light fittings complete all as specified and directed. |
| 115 | S&F sheet metal enclosure for DB's when MCBs to be used 4 way single pole and neutral double door with 200 amps rated bus bar complete including connection all as specified. |
| 116 | S&F MCB 6 to 32 amps single pole amp rating 240V, 10KA breaking capacity 'C' Curve complete all as specified. |
| 117 | S&F MCB DP 40 amps 240 volts 10KA breaking capacity 'C' Curve complete all as specified. |
| 118 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 6 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. |
| 119 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers |
| 120 | Supply and laying DWC 50mm pipe SN8 laid in trenches for protection of cable all as specified and directed by the Engr-in-Charge. |
| 121 | Materials and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4.0mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed. |
| 122 | M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm FRLH/S in and including concealed PVC conduit 20/25 mm dia medium duty ISI marked with all necessary fittings for mounting of modular switches/sockets including 1.5 sq mm FRLH/S PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light/ceiling fan/exhaust fan controlled by one switch complete including cutting, chasing the surface and then making good the same in CM 1:3 complete all as specified and directed by Engr- in-charge. |
| 123 | M & L for 40mm bore GI tubes light grade for cable protection inside in walls making good surface with all fixing accessoires (clamps, nut, bolt and washer etc) complete all as specified and directed. Make Jindal/Tata/Nezone |
| 124 | Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. Please Enable Macros to View BoQ information |