| 1 | ESTIMATE FOR PROPOSED TOILET & ROAD IN R.S HOSTEL PREMISES UNDER K.U |
| 2 | Earth work in excavation of foundation trenches or drains, in all sort (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. |
| 3 | Earth work in filling in foundation trenches or plinth with good earth,in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of found |
| 4 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 5 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 6 | Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. (a) 1:3:6 proportion |
| 7 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety |
| 8 | Supplying gravels and Labour Cost at site.Gravels Size=53mm to22.40mm(Grade-II) |
| 9 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood , beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work |
| 10 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.II. Other than JSW/JSPL/SHYAM/SRMB.../SSL |
| 11 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth |
| 12 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor |
| 13 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1 : 6 cement mortar wall(b) 20 mm thick plaster |
| 14 | (c) 15 mm thick plaster |
| 15 | (iii) With 1:3 cement mortar(c) 10 mm thick plaster |
| 16 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer |
| 17 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats)i) Standard Quality |
| 18 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative manufacturer's specification and as per direction of the EIC. In Ground |
| 19 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) (a) Normal Acrylic Emulsion |
| 20 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, glazing.(b) Openable steel windows as per IS sizes with side hung shuttersand horizotal glazing bars. [The extra rate admissible for the openable portion only] |
| 21 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall)(ii) 4 mm thick |
| 22 | Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. |
| 23 | PVC Door Shutter-37 mm thick:Supplying fitting and fixing P.V.C. door shutter of approved quality & shade inposition, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C.multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm)wall thickness, the section will have 2nos. built in beads, . Carriage of all materials taxes and all other incidentalcharges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt,door ring etc.In ground floor. |
| 24 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor(b) Area of each tile above 0.09 Sq.m (i) Coloured decorative |
| 25 | (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative |
| 26 | (a) M.S.or W.I. Ornamental grill of approved esign joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor.ii) Grill weighing above 10 kg to 16 Kg./sq.mtr and above |
| 27 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by (Cost of concrete will be paid separately)(a) 40mm X 6mm, 250mm Length |
| 28 | Anodised aluminium barrel / tower / socket bolt (full covered) of approvedmanufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(ii) 75mm long x 10mm dia. bolt. |
| 29 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complet(ii) 100 mm grip x 10 mm dia rod. |
| 30 | (a) Priming one coat on steel or other metal surface with syntheticoil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 31 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary(b) On steel or other metal surface :With other than hi-gloss of approved quality-(iv) Two coats (with any shade except white) |
| 32 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concretestructures etc if necessary and mending good damages including joining withjointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii) 110 mm. Dia. |
| 33 | B) UPVC Fittings:a) Plain Tee(ii) 110 mm. Dia. |
| 34 | d) Shoe |
| 35 | Supplying, fitting and fixing E. W.C. in white ………., nuts etc.(a) With 's' trap (with vent) |
| 36 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C(ii) Plastic (hallow type) white |
| 37 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, approved line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(A) For Exposed Work(a)(ii) 15 mm dia. medium quality |
| 38 | (A) For Exposed Work(c) (ii) 25 mm dia. medium quality |
| 39 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.)(ix) 15 mm dia |
| 40 | (vii) 25 mm dia |
| 41 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe |
| 42 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 43 | Supplying, fitting and fixing liquid soap container.(c) Fibre glass |
| 44 | Supplying, fitting and fixing soap holder.(a) PTMT (Prayag or equivalent) |
| 45 | Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass(ii) 25 mm dia. and 600 mm long |
| 46 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length(b) 110 mm |
| 47 | Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin-charge. (Payment will be made on centre line measurement of the total pipeline including specials.(ii) 110 mm dia. |
| 48 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 49 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 550 mm X 400 mm size |
| 50 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling heavy brass C.P. nut, 15 mm dia.(v) 900 mm long. |
| 51 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C.waste pipe, with PVC coupling at one end fitted with necessary clamps.(iii) 900 mm long |
| 52 | (a)(ii) Chromium plated Bib Cock short body …ESSCO or similar brand. |
| 53 | (d)(i)Chromium plated angular Stop Cock …jaquar or similar brand). |
| 54 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992xxii) 125/110 S Trap with W.C. Ring75 mm |
| 55 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(ii) Plain Tee |
| 56 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(iii) door Tee |
| 57 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(x) Bend 87.5º |
| 58 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per the pit with earth and removing spoils after work complete in all respect with all costs of labour and materialsi) With Pakur variety. (SAIL/TATA/RINL) |
| 59 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials.(i) For 10 usersA) With Pakur variety. (SAIL/TATA/RINL) |
| 60 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(b) 2000 litre capacity |
| 61 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL) |
| 62 | Earth work in excavation of foundation trenches or drains, in all sort (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. |
| 63 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 64 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 65 | Cement concrete with graded jhama khoa (30 mm size) excluding shuttering In ground floor and foundation. (a) 1:3:6 proportion |
| 66 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety |
| 67 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood , beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work |
| 68 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.II. Other than JSW/JSPL/SHYAM/SRMB.../SSL |
| 69 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth |
| 70 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor |
| 71 | (c) 15 mm thick plaster |
| 72 | 18% GST |
| 73 | 1% CESS Please Enable Macros to View BoQ information |