|
| 1 | Supply of blend of scale cum Corrosion inhibitor 1-Hydroxy Ethylidene-1, 1-Diphosphinic Acid (HEDP) with zinc, Azole, Low molecular weight polymer based on Sulphuric acid – Acrylate and Phosphonobutane tricarboxylic acid (PBTC) for NDCT and IDCT water treatment | Supply of blend of scale cum Corrosion inhibitor 1-Hydroxy Ethylidene-1, 1-Diphosphinic Acid (HEDP) with zinc, Azole, Low molecular weight polymer based on Sulphuric acid – Acrylate and Phosphonobutane tricarboxylic acid (PBTC) for NDCT and IDCT water treatment |
| 2 | Supply of Bio-dispersant as per attached technical specification for NDCT and IDCT water treatment. | Supply of Bio-dispersant as per attached technical specification for NDCT and IDCT water treatment. |
| 3 | Supply of Silica Dispersant as per attached technical specification for NDCT and IDCT water treatment | Supply of Silica Dispersant as per attached technical specification for NDCT and IDCT water treatment |
| 4 | Supply Non-oxidising Biocide (quaternary ammonium comp) as per attached technical specification for IDCT water treatment. | Supply Non-oxidising Biocide (quaternary ammonium comp) as per attached technical specification for IDCT water treatment. |
| 5 | Supply Non-oxidising Biocide (carbamate based comp) as per attached technical specification for IDCT water treatment. | Supply Non-oxidising Biocide (carbamate based comp) as per attached technical specification for IDCT water treatment. |
| 6 | Execution of Dosing, Monitoring and Chemical analysis as per scope of work for Condenser Cooling water and service water chemical Treatment as per attached specification for 4 Nos of Chemist/analyst (Skilled) | Execution of Dosing, Monitoring and Chemical analysis as per scope of work for Condenser Cooling water and service water chemical Treatment as per attached specification for 4 Nos of Chemist/analyst (Skilled) |
| 7 | Execution of Dosing, Monitoring and Chemical analysis as per scope of work for Condenser Cooling water and service water chemical Treatment as per attached specification for 2 Nos of Lab Assistant (Un Skilled) | Execution of Dosing, Monitoring and Chemical analysis as per scope of work for Condenser Cooling water and service water chemical Treatment as per attached specification for 2 Nos of Lab Assistant (Un Skilled) |
| 8 | Execution of Dosing, Monitoring and Chemical analysis as per scope of work for Condenser Cooling water and service water chemical Treatment as per attached specification for One no of Data Operator (Skilled) | Execution of Dosing, Monitoring and Chemical analysis as per scope of work for Condenser Cooling water and service water chemical Treatment as per attached specification for One no of Data Operator (Skilled) |