| 1 | Electrification |
| 2 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 3 | OD185199/2025-2026:Supply, conveyance installation testing and commissioning the light fittings of 1200 mm commercial LED integrated batten made of extruded Aluminum body and polycarbonate diffuser complete with all accessories etc. 1x 18 w LED fitting with electronic driver, Aluminum heat sink, 4000 K ,50000 Burning Hrs, flicker free , efficiency 2100 lumen efficiency suitable for continuous operation with THD less than 10%, power factor greater than 0.98, RoHS compliant, etc fittings directly fixed on wall or ceiling with factory made steel clamp to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. .. Philips make model no. Smart Bright essential BN170 C LED20S-6500 L120 PSU or it's equivalent. |
| 4 | OD105820/2025-2026:Supply and renewal of cotter pin for ceiling fan condenser in the place of damaged ones as required. |
| 5 | OD105817/2025-2026:Supply and renewal of 2.5 mfd ceiling fan condenser in the place of damaged ones and giving connections as required. |
| 6 | OD185587/2025-2026:Supply Conveyance, installation, testing and commissioning of 6W LED bulk head fittings suitable for surface and wall mounting output greater than 115 lumen/W 6500 K with IP 66 protection and IK09 protection with power factor greater than 0.95 at full load, internal surge protection up to 4 KV,and corrosion proof LM6 grade pressure die cast aluminum body & poly carbonate diffuser cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. including fixing as required Philips endura or its equivalent |
| 7 | OD105816/2025-2026:Supply and fixing 200 mm plastic shade. |
| 8 | OD105813/2025-2026:S u p p l y , c o n v e y a n c e , installation, testing and commissioning of 10W LED mirror lamp complete with all accessories and lamps etc. and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.(K Lite 1597 or equivalent make ) |
| 9 | OD108953/2025-2026: Supply, conveyance, installation, testing and commissioning of ceiling fans of the Usha make 1250 mm or its equivalent make sizes using standard accessories, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1250mm sweep - ceiling fan complete with 300mm down rod , canopies, shackles and blades working on 230V single phase AC 380 rpm , 85 watt Usha Bloom Daffodil Goodbye Dust Ceiling Fan 1250mm, Sparkle Golden and Brown or its equivalent make |
| 10 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 11 | OD107887/2025-2026:Charges Painting of stiff (fan/tube) in installed position with one or more coats of Brush painting with synthetic enamel paint of approved brand and Colour as required. |
| 12 | OD105801/2025-2026:Supply and fixing 20 A, HRC Fuse Base with HRC Fuse link |
| 13 | OD125007/2025-2026: Supply & fixing the 63, HRC Fuse Base with HRC Fuse link having connection etc as required |
| 14 | OD125008/2025-2026:Supply and fixing 32, HRC Fuse Base with HRC Fuse link |
| 15 | OD108954/2025-2026:Dismantling existing ordinary type tube from fittings and Supply,Conveyance,installation, testing and commissioning of 1x18W LED pre-wired G13 base with extruded LED Tube poly carbonate body (cool white at 6500 K temprature ) 1200 mm, T8 I, 18 w with nominal system level lumen pakage of 2100 Lumen having effiency of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accradation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. .( Make -Philips/Equivalent) |
| 16 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 17 | 1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 18 | OD105803/2025-2026:Supply and fix E-22/E-27 Type 9W LED bulb 3000 K in Existing angle / straightbrass lined skirt type, Bakelite batten holder etc. as required. |
| 19 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 20 | 1.59:Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required. |
| 21 | 90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 22 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 23 | 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 24 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 25 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 26 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 27 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 28 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 29 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 30 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 31 | 90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator |
| 32 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top |
| 33 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 34 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 35 | 1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 36 | 1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 37 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 38 | OD185630/2025-2026:Supply of Distilled/Deionized Lead acid battery water (5 Liter Bottle) |
| 39 | 1.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 40 | OD185639/2025-2026:Refilling of FIRE EXTINGUISHER 6 kg :- Renewing powder and Cartridge of 6kg Fire extinguisher if it failed in pressure test, including replacing cartridge, dry chemical powder and painting the shell with postoffice red synthetic enamel paint, , new labeling and fitted in the same location as required. |
| 41 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 42 | 1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module |
| 43 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 44 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 45 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 46 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 47 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 48 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 49 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 50 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 51 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 52 | 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 53 | 90.14.28.1:S & F Motor starters of the following ratingsSingle phase DOL starters for 0.25HP to 3HP motor |
| 54 | OD105811/2025-2026:Labour charges for the maintenance of Electrical installation including attending petty repairs , cleaning, of light fittings ,ceiling fan and exhaust fan ,checking all electrical connection in the DB and switch board. |
| 55 | OD108184/2025-2026:Supply and replacing of Auto Cut-Off Thermostat/electric Water Heater Geyseras required |
| 56 | OD108185/2025-2026:Supply and replacing of damaged 2000 W Heating coil suitable for water Heater, Geyser and giving connection etc as required |
| 57 | OD108201/2025-2026:Providing and fixing brass bib cock of approved quality 20 mm nominal bore etc as required . |
| 58 | OD108203/2025-2026:Annual Maintenance and servicing of 1/2/3 TR, 240/415V Air Conditioner Units (Vertical and Wall/Floor Mounting type Split Air Conditioner Units covering all routine and preventive maintenance, attending to all breakdowns and rectifying the defects if any (excluding the cost of spare). The cleaning and servicing of IDU and ODU includes 1no. water servicing using chemicals, water pump etc. and 3 nos. Air servicing using cleaning materials and pressure air pump etc. The operating status of the units should be regularly monitored and intimated to the department staff in charge and the Air conditioner Units should be maintained in proper working condition through out the period of contract |
| 59 | OD108167/2025-2026:Supply and filling Refrigerant Gas R22/32/410Afor AC compresser |
| 60 | OD108235/2025-2026:Supply Installation testing and commissioning of ODU Sensers Unit for 1.5 TON Air conditioner. |
| 61 | OD108248/2025-2026:Supply Installation testing and commissioning of Outdoor PCB Unit for 1.5 TON Air conditioner. |
| 62 | OD108271/2025-2026:Supply and Renewing of Fuel Filter for 40 KVA Diesel Generator Set etc as required. |
| 63 | OD108272/2025-2026:Supply and Renewing of Fuel Filter for 20/25 KVA Diesel Generator Set etc as required. |
| 64 | OD108273/2025-2026:Supply and Renewing of Oil Filter for 40 KVA Diesel Generator Set etc as required. |
| 65 | OD108274/2025-2026:Supply and Renewing of Oil Filter for 20/25 KVA Diesel Generator Set etc as required. |
| 66 | OD108277/2025-2026:Supply and Renewing of Engine Oil for Diesel Generator Set etc as required. |
| 67 | OD108278/2025-2026:Supply and Renewing of Coolant for 20/25/40 KVA Diesel Generator Set etc as required. |
| 68 | OD105802/2025-2026:Charges for dismantling tube light/ceiling fan/wall fan and conveyance to sectionstore etc as required. |
| 69 | OD181060/2025-2026:Supply Installation Testing and Commissioning of AQUATEX TEXMO Make 1.5HP / 1.1 KW, Type ACSN 1140 ISI , Single phaseCentrifugal mono Block pump set working with 240 V 2900 RPM , 50 HZ , ACsupply etc as required. |
| 70 | OD181113/2025-2026:Supply and fixing 50 mm Dutron Kanaflex Hose etc as required |
| 71 | OD181125/2025-2026:Supply and fixing 50 mm CI Foot Valve etc as required |
| 72 | OD181132/2025-2026:Supply and fixing of Hose Collar Steel 50mm using suitable items as required . |
| 73 | OD181133/2025-2026:Supply and fixing 50 mm Hose Clip screw type etc as required. |
| 74 | OD181142/2025-2026:Supply and fixing of 40mm dia. GI bend ( medium class ) using suitable items etc as required . |
| 75 | OD181176/2025-2026:Supply and fitting of Barrel nipple GI 25 mm x 9 inch ISI etc as required. |
| 76 | OD181177/2025-2026:Supply and fitting of 40 mm X 25 mm GI TEE ISI etc as required. |
| 77 | OD181183/2025-2026:Supply and fixing 32 mm Threaded type Ball Valve UPVC etc as required. |
| 78 | OD181088/2025-2026:Supply and fixing 50 mm MTA PVC supreme PN 16 etc as required. |
| 79 | OD181095/2025-2026:Supply and providing motor pump set cover etc. as required. Please Enable Macros to View BoQ information |