| 1 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft&loose soil all as directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick with soils complete all as specified and as directed. |
| 3 | Removing of excavated material (soil) to distance not exc. 50 metres and deposited where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed. |
| 4 | Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified & directed.(Note: Thickness after punning shall be measured for payment ) all as specified and directed. |
| 5 | Supplying & laying reinforced precast concrete cable cover, class HV,Type 1, flat, size 300 mm x 180 mm x 40 mm abetting Each other with gap between adjacent slab not exceeding 10mm over under cable for protection all as specified and directed. |
| 6 | Dismantling and Taking down old unserviceable existing cable any type any size complete |
| 7 | Supply, lay, test and commissioning of XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HTUG), 11000 volts grade with stranded aluminium conductor of size 3 core 95 Sqmm ( Earthed) including takingout existing unserviceable cable all as specified and as directed.Note - Rates are included with Megger testing of Cable. |
| 8 | Material and labour for cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. |
| 9 | Supply and fix HT 11KV outdoor type Gang operated air break switch of rating upto 200 amps, vertical mounted fixed complete with 9 insulators including , operating rod of 25mm dia medium garde GI tubing of suitable length, operating handle with locking arrangement fixed to pole with suitable size of MS clamps to be operated from ground level, provn of insulated connected leads of connections with required accessories complete all as specified and directed |
| 10 | S & F Lightning arrester suitable for 11 KV, expulsion type, confirming to IS- 3070 part-I of 1985 complete with all fittings transmission class, discharge capacity of 65 KA compplete all as specified and directed. Please Enable Macros to View BoQ information |