| 1 | Power Fencing |
| 2 | OD268344/2025-2026:Supply and installation of a professional-grade Power fence energizer suitable for perimeter security. The energizer shall operate on a 12 V DC standard battery-powered input with a maximum input current of 1.0 ampere. Output energy : 5 joule, output voltage: minimum 10 kV (10,000 V DC). pulse duration: maximum 0.9 seconds (1 Hz) with a pulse interval of not more than 1.3 seconds or better. The system shall provide effective protection coverage up to 4,000 meters. The operating temperature range shall be from 10 °C to 50 °C.The energizer shall be equipped with smart safety features including fence tampering, short circuit,fence fault detection with hooter alarm indication and low battery level indication. The unit shall be housed in a weather-resistant casing suitable for continuous outdoor operation. Certifications: ISI certified and compliant with applicable Standards. Warranty: 3 years On site.Preferred Make ISI approved models. |
| 3 | OD268896/2025-2026:Supply and installation of 12V 150Ah/C20 Tubular battery including battery stand for keeping battery.Warranty : 3 years onsite.Preferred Make: Exide, Amaron. |
| 4 | OD268932/2025-2026:Supply and installation of Compatible 12 V, up to 10 amps automatic float/boost battery charger for charging above battery including charging cable and Digital Volt meter. Warranty 3 yearsPreferred Make: Exide or Equivalent. |
| 5 | OD268990/2025-2026:Supply and installation of lead-out cable and connectors with double-insulated inner conductor, hot-dip galvanized, capable of withstanding voltages up to 15 kV . |
| 6 | OD268995/2025-2026:Supply and installation of Fence Cut Out /Disconnection Switch from battery for power fence isolation having highly visible on/off position. |
| 7 | OD270450/2025-2026:Supply and fixing of fitting accessories for laying of fence wire on poles, including C-type aluminium alloy permanent wire tighteners conforming to IG-643 with a minimum mechanical strength of 500 N (minimum quantity 90 numbers), reel insulators (minimum quantity 1,300 numbers), and corner/strain insulators (minimum quantity 125 numbers). All insulators shall be manufactured from high-quality industrial plastic. Reel insulators shall be made of virgin polypropylene plastic, rated for 15 kV, UV-stabilized, and designed to allow proper rainwater run-off. All accessories shall be installed as per site conditions and layout. |
| 8 | OD269348/2025-2026:Supply and installation of corner posts made of 50 mm (2 inch) GI pipe, Class B, conforming to ISI standards, with punched holes to facilitate fence wire fixing, up to 1.50 meters in length, installed as per site conditions. |
| 9 | OD270538/2025-2026:Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of min 1500mm length , having a diameter of 14.2mm with copper bonding thickness of 250 microns as per UL 467. The rod must be having corrosion test, peel off test for uniform coating, 180 degree bend test with out peeloff of copper bonding. Exothermic welded Clamp for clamping as suggested as per NBC 2016. Ordinary Stainless steel/Copper alloy universal clamps are not recommended. . Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances. The mineral compound is required to have minimum 5 Kg of the total composite. The compound should be chemically inert and needs to submit Govt approved Indian labs test certificate. FRP Earth electrode inspection chamber with weight bearing capacity of 60KN. The dimension shall be 290mmx 290mmx 209mm. Govt approved Indian labs test certificate required. Approved Make: Cape, Erico, Furse, OBO. |
| 10 | OD270540/2025-2026:Providing and fixing 4.00 mm dia pure copper wire on surface or in recess for fence earthing as required. |
| 11 | OD271241/2025-2026:Supply and Installation of necessary Electrical accessories for the distribution of KSEB Power for battery charging in to in a structured way, using 2.5 Sqmm Multi Strand Wire, 16Amps Switch Socket /MCCB Combined with Porcelain Junction Box for displays as per site condition ,Electrical PVC boxes etc. as per the site condition. |
| 12 | OD271242/2025-2026:Supply and laying of flexible 25 mm HDPE / PVC pipe conforming to IS 4984, including all required accessories, laid in trench or on surface. |
| 13 | OD271243/2025-2026:Demolishing the concrete/removing interlock/cutting the tar, for doing excavation of trench in soft soil, depth up to 1.2 m and breadth up to 0.25m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering ,disposal of surplus excavated soil as directed, within a lead of 50 metres for laying armored cables and making good the damages and concreting/refixing the interlock/ cement concrete at the top in the ratio1:3:6 ( 1cement:3 coarse:6 sand). |
| 14 | OD271342/2025-2026:Supply and installation of Warning sign board made of polyethylene with high-visibility (H.V.) safety sign and statutory colours. |
| 15 | OD285222/2025-2026:Supply and installation of Lightning diverter kit for power fencing including Suitable copper rod earthing. |
| 16 | OD285716/2025-2026:Supply and laying of 12 SWG 2.642 mm stainless steel (Grade 304 or better)/ACSR high-tensile fencing wire on 6 lines of power fencing, to be installed for a minimum length of 187 meters per line over 187 existing poles, as per site conditions. This includes scaffolding charges and a complete tool kit with wire tightener, handle twisting tool, pliers, and double-ended spanner for clamp tightening, etc.Preferred make: ISI marked (IS 6911 standards). |
| 17 | OD285723/2025-2026:Supply and laying of 14 SWGstainless steel (Grade 304 or better)/ACSR binding wire on 6 lines of power fencing, to be installed over 187 existing poles, as per site conditions. Preferred make: ISI marked (IS 6911 standards). Please Enable Macros to View BoQ information |