Tender For Repairs And Maintenance Of Street Light, Gate Light And Decorative Light, Pole And Allied Work Under Ge Dehu Road
Tender Value
40 Lakhs
Estimated cost
Bid Submission
02 Jul 2026
0 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehu Road → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs And Maintenance Of Street Light, Gate Light And Decorative Light, Pole And Allied Work Under Ge Dehu Road
BOQ
| Sl. No. | Item Description |
| 1 | Supply, fixing, connecting and testing in replacement integral LED flood light fitting, 50 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass with over voltage protection,short circuit protection ,open circuit protection ,surge protection,,LED CCT is 5700 K and IP-66 as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm complete all as specified and directed . Make:- Crompton/Philips/Havelles |
| 2 | Supply, fixing, connecting and testing in replacement integral LED flood light fitting, 120 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass,individual LEDs with secondary lens optics with IP66 ingress protection ,over voltage protection,short circuit protection ,open circuit protection ,surge protection,LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm complete all as specified and directed . Make:- Crompton/Philips/Havelles |
| 3 | Supply, fixing, connecting and testing in replacement integral LED flood light fitting, 150 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass,individual LEDs with secondary lens optics with IP66 ingress protection , over voltage protection,short circuit protection ,open circuit protection ,surge protection,LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm complete all as specified and directed . Make:- Crompton/Philips/Havelles |
| 4 | Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 60 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass with over voltage protection,short circuit protection ,open circuit protection ,surge protection ,LED CCT is 5700 K and IP-66 as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm complete all as specified and directed . Make:- Crompton/Philips/Havelles |
| 5 | Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 90 watts energy saving & environmental friendly long life versatilepressure die cast aluminium body with clear toughened glass , individual LEDs with secondary lens optics with IP66 ingress protection, over voltage protection,short circuit protection ,open circuit protection ,surge protection,LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm complete all as specified and directed .Make:- Crompton/Philips/Havelles |
| 6 | Supply, fixing, connecting and testing in replacement integral LED Street light fitting, 120 watts energy saving & environmental friendly long life versatile pressure die cast aluminium body with clear toughened glass, individual LEDs with secondary lens optics with IP66 ingress protection , over voltage protection,short circuit protection ,open circuit protection ,external surge protection ,LED CCT is 5700 K as light source suitable making connection with three core PVC insulated and sheathed copper conductor cable of size 1.5/2.5 Sqmm complete all as specified and directed . Make:- Crompton/Philips/Havelles |
| 7 | M&L for preparation of old painted surfaces of steel tubular pole/strut, of any description and in any position 9.00/8.50/11 Mtr height and scrapping of pole with emery paper and applying two coat of aluminium paint on all the metallic surfaces including protection pipe,clamps, GI pipe bracket of street/security light, and pasting reflector tape 3 differnt colour for around the pole with applying one coats of white wash painting on coping of pole and numbering of street poles alongwith Sub station complete all as specified and directed. Make:- Crompton/Philips/Havelles |
| 8 | M&L for preparation of old painted surfaces of PCC pole of any description and in any position 9.00/8.50 Mtr height and scrapping of pole with applying two coat of cement paint on PCC surfaces and applying two coat of aluminium paint on all the metallic surfaces including protection pipe,clamps, GI pipe bracket of security light, and pasting reflector tape 3 differnt colour for around the pole with applying one coats of white wash painting on coping of pole and numbering of street poles alongwith Sub station complete all as specified and directed. Make:- Crompton/Philips/Havelles |
| 9 | Supply and fixing 1.5 SQMM FRLSH PVC insulated three core unsheathed industrial multistrand cable with flame retardent low smoke (FRLSH) properties with flexible bright annealed bare copper conductor for voltage grade upto 1100 V confirming to IS-694:2010 all as specified and directed. Make:- Finolex/Havelles/Polycab |
| 10 | Supply and fixing 2.5 SQMM FRLSH PVC insulated three core unsheathed industrial multistrand cable with flame retardent low smoke (FRLSH) properties with flexible bright annealed bare copper conductor for voltage grade upto 1100 V confirming to IS-694:2010 all as specified and directed. Make:- Finolex/Havelles/Polycab |
| 11 | Supply & Fixing,Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / pipe ducts/drwan through DWC pipe of following sizes incl taking out old U/S cable all as specified and directed. Make:- Finolex/Havelles/Polycab |
| 12 | (a) 4 core 6 Sqmm |
| 13 | (b) 4 core 10 Sqmm |
| 14 | (c) 4 core 16 Sqmm |
| 15 | (d) 3.5 core 25 Sqmm |
| 16 | (e) 3.5 core 50 Sqmm |
| 17 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in soft/loose soil complete all as specified and directed. |
| 18 | Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed. |
| 19 | Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the Starting point all as specified and directed . |
| 20 | Supply and fixing SS nut bolts ,clamp ,screw of different size and sample complete all as specified and directed. |
| 21 | Supply and laying of 63 mm outer dia ,double wall corrugated (DWC) duct pipe conforming to IS 16205 (Part 24) with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection all as specified and as directed. |
| 22 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed Sheet steel enclosure made of rust proof, Electric shock proof, termite proof and FR grade conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.16sqmm) should enough to take: three-phase load of 12KW;contactor Rating 63Amps; MCB(spn) Rating 63Amps including making all connectiuon all as specified and directed by engineer in Charge..MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs(Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. |
| 23 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in sheet steel enclosure made of rust proof, Electric shock proof, termite proof and FR grade conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: Single-phase load of 5KW;contactor Rating 40Amps; MCB(sp) Rating 40Amps including making all connectiuon all as specified and directed by engineer in Charge.MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs(Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. |
| 24 | Supply and erection of steel tubular swaged pole 410 SP 22, 8.5 Mtr long ,swan neck complete with cast iron base plate, finial Taper plug, bolts, nuts, and screws as specified type conforming to IS 2713 complete including 2 coats of aluminium paint over one coat of red oxide zinc chrome primer on external exposed surfaces and 2 coats of black bituminous paint on portion embedded in concrete in internal surfaces of pole including taking out old pole, complete all as specified and directed. |
| 25 | M&L for PCC 1:3:6 type C2 using (40 mm gradded stone aggregate) as in foundation of pole complete all as specified &directed. |
| 26 | M&L for PCC type B-1, 1:2:4 using (20 mm gradded stone aggregate) as in coping, including form work complete all as specified & directed. |
| 27 | M & L for repair of high mast pole of 16 Mtr including servicing of gear box ,servicing of motor and connected accessories all as specified and directed. |
| 28 | Supply & Fixing 10 mm galvanised steel wire rope multi stranded complete all as specified and as directed |
| 29 | S & F Cable Junction Boxes for outdoor installation of size 155 mm x210 mmx92 mm complete with electrolytic aluminum bus bar suitable cable size 10-16 sqmm for 3 phase and neutral fixed on ebonite insulator and one DP 6-32 A complete all as specified and directed. |
| 30 | Supply & Fix in repair bracket for street light fittings made out of 40 mm bore light grade GI tubing 1.5 m long bent to shape inculding fabrication work ,clamp ,nut & bolts and applying two coats of aluminium paint over a coat of red oxide zinc chrome primer repair all as specified and directed. |
| 31 | M&L for street light bracket 1.5 mtr long made out of 50mm dia light grade GI tube one and duly welded with 100mm dia 30 cm long GI tube including provision of 4 Nos holes duly threaded for fixing the bracket on the top of existing poles with complete including arrangment of threding and weldeding work required for fixing of street light fitting complete including taking down U/S bracket all as specified and directed. |
| 32 | Supply & fixing in repair of Contactor- 3/4 Pole,100 Amps/ 65 Amps with replacement of lugs and checking of all connections etc including taking down u/s contactor complete all as specified and directed. |
| 33 | Supply & fixing in repair of Contactor- 3/4 Pole,60 Amps/ 40 Amps with replacement of lugs and checking of all connections etc including taking down u/s contactor complete all as specified and directed. |
| 34 | M & L for DP of 6-32 A ,240 V with breaking capacity 10 KA Conforming to IS/IEC 60898-1:2015 all as specified and directed. |
| 35 | M & L for DP of 40 A ,240 V with breaking capacity 10 KA Conforming to IS/IEC 60898-1:2015 all as specified and directed. |
| 36 | Supply and fix in repair Driver for LED lights as per existing make for the following capacity including taking down U/S driver all as specified and directed :- |
| 37 | (a) Driver for 70/72watts LED |
| 38 | (b) Driver for 90 watts LED |
| 39 | (c) Driver for 120-150 Watts LED |
| 40 | Taking out cable loop after necessary excavation , cutting the burnt out damage end of cable ,refixing the cable providing suitable size of brass cable gland and aluminium lugs complete with all necessary connection with the existing system and refilling of excavated soil making finishing with the existing ground surface for the following sizes:- |
| 41 | (a) 2/3.5/4 core 4 to16 Sqmm |
| 42 | (b) 3.5/4 core 25 to 35 Sqmm |
| 43 | (c) 3.5/4 core 50 Sqmm |
| 44 | (d) 3.5/4 core 70 to 95 Sqmm |
| 45 | M & L for checking & serviceability Street lights/flood lights/tower lights/highmast lights/Garden light etc and found unserviceability during checking as per directed by department ,rectification of fault of Street lights/flood lights/tower lights/highmast lights etc by deploying resource with all tools & plants, telescopic ladder, gaskets safety arrangements and including providing minor materials like insulation tap insulation tap/wire connecter/repairing of junction box with lugs/nut bolts etc by contractor to make light serviceable within same day after receving complaint from department all as specified and directed .(Notes:-Each Job consist of 10 number of complaint ) |
| 46 | Supply and fix LED post top lantern 40 W New generation with IP 65, LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source LED CCT is 5700 K & post top light having inbuilt driver with suitable surge protection. Clear Cover offers bright illumination for different applications complete with all accessories complete all as specified and directed.Make:- Crompton/Philips/Havelles |
| 47 | Supply & Fix 8/9 W LED Bollard fitting of size 600 mm with New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for as light source of size 600 mm complete with all accessories, LED CCT is 5700 K & bollard light having inbuilt driver with suitable surge protection and making suitable foundations as specified.Make:- Crompton/Philips/Havelles |
| 48 | S & F for UPVC pipe 20 mm bore fixed complete to walls, pillar etc., for conduit of wire with all fittings complete & saddling of pipe in pillar with clamp all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayJul 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 day