| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: MILITARY ENGINEERING SERVICES (GE (SOUTH) UDHAMPUR) NAME OF WORK : REPAIR/ MAINTENANCE OF CERTAIN PART OF GEYSERS AND ALLIED WORKS UNDER GE (SOUTH) UDHAMPUR Contract No: CA NO : GE/S(U)-62/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Point wiring for one light/ fan/bell point controlled by one switch using 4.0 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in existing conduit of any size/makeas per site requirement,(size not less than 20mm dia) medium grade with Modular sunken boxe, PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 4.0 Sq mm as earth wire stranded and conected to earth dolly as specified. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish. |
| 3 | Point wiring for one light/ socket point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in concealed conduit of any size/makeas per site requirement,(size not less than 20mm dia) medium grade with Modular sunken boxe, PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly as specified. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish. |
| 4 | All as per srl item No 1 but in concealed conduit including PVC insulated PVC unsheathed 4.0 sq mm earth wire and connected to earth dolly. |
| 5 | All as per srl item No 2 but in casing capping including PVC insulated PVC unsheathed 4.0 sq mm earth wire and connected to earth dolly. |
| 6 | Supply & Fixing of 25A MCB Protected Heavy Duty AC Box with 16A Plug top for AC, Refrigerator, Geyser, Industrial Use complete all as specified and directed. Make: Havells / Finolex / Polycab. |
| 7 | Supply & Fixing of SS connection heavy duty (steel reinforced type) connecting with two Nos of brass adopter and nylon washer of size 450 mm long suitable for geyser and including all fixing accessories complete all as specified and directed. |
| 8 | Supply & Fixing of SS connection heavy duty (steel reinforced type) connecting with two Nos of brass adopter and nylon washer of size 300 mm long suitable for geyser and including all fixing accessories complete all as specified and directed. |
| 9 | Supply & Fixing of assy/Apparatus plate heavy duty 18 SWG with rubber gasket of suitable size for 25/35/50 Ltr cap 9/6 holes geyser of any make complete all as specified and directed. |
| 10 | Supply & Fixing of Heating element any type (i.e Cup/ threaded/triangular) 2.0 KW, 220/230 volts (ISI marked) complete all as specified and directed. |
| 11 | Supply of Heating element complete set for Havells geyser of 2.0 KW, 220/230 volts (ISI marked) complete all as specified and directed. |
| 12 | Supply & Fixing of Heating element complete set for Bajaj Calanta geyser of 2.0 KW, 220/230 volts (ISI marked) complete all as specified and directed. |
| 13 | Supply of Heating element complete set for Racold geyser of 1.5 KW, vertical plate type/horizontal triangular type 220/230 volts (ISI marked) complete all as specified and directed. |
| 14 | Supply & Fixing of thermostat ranging 60 degree to 90 degree adjustable type, long, Operative on 250 Volts complete all as specified and directed. |
| 15 | Supply of Element holding clamp suitable for geyser of cap 25/35/50 ltr.complete all as specified and directed. |
| 16 | Supply & Fixing of stainless steel inner tank Capacity 25 Ltrs heavy duty (Approx height 304 mm) with SS 304 Grade complete all as specified and directed. |
| 17 | Supply & Fixing of stainless steel inner tank capacity 35 ltr heavy duty (Approx height 396 mm) with SS 304 Grade complete all as specified and directed please. |
| 18 | Supply & Fixing of indicator lamp, round/square, green /red as per requirement complete all as specified and directed. |
| 19 | Supply & Fixing of PVC insulated Top plug 3 pin 15 Amp (ISI Marked) complete all as specified and directed. Make- Havells/Anchor/as equivalent |
| 20 | Supply & Fixing of glass wool for Geyser of any Make for capacity 25/35/50 ltrs complete all as specified and directed. |
| 21 | GI Fastner bolts including nuts washer off sizes 4/6 Inch suitable for fixing of any capacitty geysers as required at ite to the entire satisfaction of Engineer-in-Charge. |
| 22 | Supply & Fixing PVC Copper cable flexible 3 core round heavy duty size 4 Sqmm suitable for geyser any capacity to the entire satisfaction of Engineer-in-Charge. |
| 23 | Repair/Replacement 05 star rated vertical type electric water heater storage type with steel inner tank and heating element up to 2KW tank capacity 25 litre complete with all accessories such as safety valave thermostate NRV connection piece etc complete all as specified and directed by EIC.Note: Sample of Geyser shall be approved by GE and 01 sample shall be kept in GE office and payment of same shall be released after 100% installation. |
| 24 | Repair/Replacement 05 star rated vertical type electric water heater storage type with steel inner tank and heating element up to 2KW tank capacity 25 litre with digital temperature display complete with all accessories such as safety valave thermostate NRV connection piece etc complete all as specified and directed by EIC.Note: Sample of Geyser shall be approved by GE and 01 sample shall be kept in GE office and payment of same shall be released after 100% installation. |
| 25 | Repair/Replacement 05 star rated vertical type electric water heater storage type with steel inner tank and heating element up to 3KW tank capacity 35 litre complete with all accessories such as safety valave thermostate NRV connection piece etc complete all as specified and directed by EIC. |
| 26 | S & F 1 Ltr Instant Water heater with SS Tank and copper heating element with all accessories complete all as specified and directed by EIC.Note:- Sample of Geyser shall be approved by GE and 01 sample shall be kept in GE office and payment of same shall be released after 100% installation. |
| 27 | Supply & Fixing of bolts, nut, washers and wall fasteners 4\\" long 8mm dia for Geysers complete all as specified and directed. |
| 28 | S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2.5 Sqmm in existing concealed /on wall conduit/casing capping 25mm dia including PVC insulated copper conductor cable 2.5 Sq mm as earth lead all as specified. |
| 29 | S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 1.5 Sqmm in existing concealed /on wall conduit/casing capping 25mm dia including PVC insulated copper conductor cable 1.5 Sq mm as earth lead all as specified. |
| 30 | Switch - socket combination 15 Amps, multipurpose complete all as specified and directed. |
| 31 | Switch modular type, 1 module, type 20 Amps 230 volts one way complete all as specified and directed. |
| 32 | Socket outlet, modular type, 2 module, 2-in-1, 20 Amps combined complete all as specified and directed. |
| 33 | S&F Switch piano, flush type single pole, one way 5 Amp 230 V, 50 Hz, AC , complete all as specified and directed by Engr In charge |
| 34 | S&F Switch piano, flush type single pole, one way 15 Amp 230 V, 50 Hz, AC , complete all as specified and directed by Engr In charge |
| 35 | S & F 3 Ltr Instant Water heater with SS Tank and copper heating element with all accessories complete all as specified and directed by EIC.Note:- Sample of Geyser shall be approved by GE and 01 sample shall be kept in GE office and payment of same shall be released after 100% installation. |
| 36 | MCB Single Pole and neutral 240 Volt any rating from 32 Amps with rupturing capacity 10 KA including complete all as specified and directed. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |