| 1 | Labour only for servicing, cleaning of indoor/outdoor unit of AC's split type of capacity 1.5/2 TR including oiling, greasing of fan motor, replacement of air filter as required and checking of electronic circuit for smooth functioning by highly skilled technician /helper as recommended by OEM complete all as specified and as directed by Engr-in-Charge. |
| 2 | All as per item No 1 above but for window AC of capacity 1.5/2 TR complete all as specified and as directed. |
| 3 | Supply and fixing PVC pipe size 20mm dia including bends, elbows, socket etc fixed to wall by clamps, brackets, saddles etc complete all as specified and as directed by Engr-in-charge. |
| 4 | Supply & fixing in replacement of starting relay suitable for 1.5 TR/2TR capacity AC complete all as specified and as directed. make: Classic/Renutrol |
| 5 | S&F in replacement of over load protector suitable for 1.5/2.0 TR capacity complete all as specified and as directed. Make: Classic/Renutrol |
| 6 | Supply only in replacement of starting capacitor 60+6/ 60 mfd suitable for 1.5 ton capacity/AC complete all as specified and as directed. make Tesla/Usha/GDR/Tibcon/EPCOS |
| 7 | Supply only in replacemernt of capacitor 55+6/ 55 mfd suitable for 1.5 ton capacity AC complete all as specified and as directed. Make: Usha/Asian/Tibcon/EPCOS |
| 8 | All as per item No 7 above but 50+6/ 50 mfd suitable for 1.5 ton capacity complete all as specified and as directed. |
| 9 | All as per item No 7 above but 45+6/ 45 mfd suitable for 2.0 ton capacity complete all as specified and as directed. |
| 10 | All as per item No 7 above but 36+6/ 36 mfd suitable for 2.0 ton capacity complete all as specified and as directed. |
| 11 | All as per item No 7 above but 1/2 to 6 mfd suitable as per site requirement complete all as specified and as directed. |
| 12 | S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity /Window AC complete all as specified and directed. |
| 13 | S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity Split AC complete all as specified and directed. |
| 14 | S&F in replacement of thermostate switch suitable1.5/2 Ton capacity AC complete all as specified and directed. |
| 15 | S&F in replacement of front grill suitable for 1.5/2.0 TR capacity of window AC complete all as specified and as directed. |
| 16 | All as per item No 15 above but base plate suitable for 1.5/2.0 TR capacity of window AC complete all as specified and as directed. |
| 17 | S&F in replacement of metal clad socket 20 Amp complete all as specified and as directed. Make:- Crompton/Havells |
| 18 | All as per item No 17 above but metal clad plug complete all as specified and as directed. Make Crompton/Havells/Philips |
| 19 | Taking out unserviceable fan-cum-blower motor and M&L for rewinding and repairing of fan-cum-blower motor of window tpe AC 1.5/2.00 TR capacity with supper enamelled copper winding wire of existing gauge complete all as specified and as directed by Egnineer-in-charge. |
| 20 | All as per item No 19 above but fan motor for split type AC 1.5/2.0 TR complete all as specified and as directed. |
| 21 | All as per item No 19 above but blower motor for split type AC 1.5/2.0 TR complete all as specified and as directed. |
| 22 | S&F new reciprocating type compressor of capacity 1.5 TR in replacement to unserviceable compressor complete all as specified and as directed. Make:- Emerson copeland/Tecumesh /Carrier. Note:- Charging of gas shall be paid separately under respective item. |
| 23 | All as per item No 22 above but capacity 2.0 TR complete all as specified and as directed. |
| 24 | S&F new fan-cum-blower motor with propeller, fan blade, rubber seal, holding clamps nuts & bolts for 1.5/2 TR window AC in replacemnt to unserviceable motor complete all as specified and as directed. Make:- AUE/ANU/GE Motors/Marathan |
| 25 | S&F new blower blade for 1.5/2 TR window AC in replacement of old unserviceable fan blade complete all as specified and as directed. |
| 26 | S&F new fan blade for 1.5/2 TR window/split AC in replacement of old unserviceable fan blade complete all as specified and as directed. |
| 27 | S&F new blower for 1.5/2 TR split AC in replacement of old unserviceable blower complete all as specified and as directed. |
| 28 | Supply & charging the refrigerant gas R-22 to window/split type AC upto 2 TR capacity including test complete all as specified and as directed. |
| 29 | Supply & charging the refrigerant gas R-410A to split type AC upto 2 ton capacity including testing complete all as specified and as directed. |
| 30 | Supply & charging the refrigerant gas R-32 to split type AC upto 2 ton capacity including testing complete all as specified and directed. |
| 31 | Supply & fix in replacement sheet metal single pole and neutral enclosure with a two pin and earth plug and socket compelte with one signle pole MCB 20 Amps complete all as specified and as directed. Make:- Havells/Crompton |
| 32 | Supply & fixing in replacement of compressor of water cooler of capacity 150/180 Ltrs of any type complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F new rotary type compressor of capacity 1.5 TR suitable for working on R-22 Refrigerant in replacement to unserviceable compressor complete all as specified and as directed. make:- Mitsubhishi/Tech mesh product/LG Hitach Note:- Charging of gas shall be measured and paid separately under respective item. |
| 34 | All as per item No 33 above but 2.0 TR complete all as specified and as directed. |
| 35 | S&F new rotary type compressor of capacity 1.5 TR sunitable for working on R-410 A refrigerant in replacment to unserviceable compressor complete all as specified and as directed. Make: Mitsubishi/Techmesh/LG/HiTachi/Carrier Note:- Charging of gas shall be measured and paid separately under respective item. |
| 36 | All as per item No 35 above but capacity 2.0 TR complete all as specified and as directed. |
| 37 | S&F inverter type compressor of capacity 1.5 TR for R-32 Refrigerant of any type complete all as specified and as directed. |
| 38 | All as per item No 37 above but 2.0 TR complete all as specified and as directed. |
| 39 | Supply & fix in replacement new inverter type PCB card suitable for 1.0/1.5/2. 0 TR capacity of split ACs including suitable for invertor AC's of said capacity complete all as specified and as directed. |
| 40 | M&L for repairing of inverter PCB card suitable for 1.5/2 TR capacity of split AC's complete all as specified and as directed. |
| 41 | M&L for repairing of PCB card suitable for 1.5/2 TR capacity of split AC's complete all as specified and directed. |
| 42 | Supply & fixing in replacement new swing motor suitable for 1.5/2.0 TR capacity of window/Split AC complete all as specified and as directed. |
| 43 | Supply & fixing in replacemnt of PVC drain pipe 15mm dia with fittings and fixing accessories complete all as specified and as directed. |
| 44 | S&F reverse valve suitable for split type AC 1.5/2.0 TR including additional copper tubing of any size brazing work, presure testing dehydration gas charging upto required level and necessray modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and as directed. |
| 45 | S&F condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR window type AC suitable for working on R-22 Refrigerant in replacement of old unserviceable condenser complete all as specified and as directed. Note:- Supply and filling of refrigerant gas shall be measured and paid separately under respective item of this BOQ. |
| 46 | All as per item No 45 above but split type AC's complete all as specified and as directed. |
| 47 | S&F condensor with copper tubing and aluminium fins suitabel for 1.5/2.0 TR window type AC suitable for working on R-410A refriegrant in replacement of old unserviceable condenser complete all as specified and as directed. Note:- Supply & filling of refrigerant gas shall be measured and paid separately under respective item of this BOQ. |
| 48 | All as per item No 47 above but split type AC's complete all as specified and as directed. |
| 49 | Taking out old perished insulation and M&L for insulating the suction and discharge copper tubing from in door unit to outdoor unit of split type Acs of capacity 1.5/2.0 TR capacity with neoprene foam sleeves incuding sealing by applying adhesive tape fo brown or white colour to avoid minimum contact with atmosphere complete all as specified and as directed. |
| 50 | Taking out old unserviceable copper tubing and M&L for suction and discharge copper tubing in replacement of size 1/2 inch and 1/4 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 1.5 TR capacity including soldering and braizing complete all as specified and as directed. Note:- Suction and discharge copper tubing together shall be measured as one unit of running metre. |
| 51 | All as per item No 50 above but copper tubing size 5/8 inch and 3/8 inch dia and 0.5mm thickness complete all as specified and as directed. |
| 52 | Taking out old unserviceable suction line valve assy of size 1/2\\" dia from outdoor unit of split tpe AC and S&F new suction including soldering and braizing complete all as specified and as directed. |
| 53 | Description all as per ser item No 52 above but discharge valve assy size 3/8\\" dia complete all as specified and as directed. |
| 54 | S&F PVC flexible pipe inclusive of all clamps (40mm, 32mm, 28mm, 16mm, 10mm), tie belt (10inch, 12 inchs) and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed. |
| 55 | S&F in replacement electric cables PVC insulated rubber sheathed circular multistranded copper conductor of size 2.5sqmm 4 core complete all as specified and as directed. Make:- National/Havells/Kalinga/Plaza |
| 56 | S&F in replacement electric cables PVC insulated rubber sheathed circular multistranded copper conductor of size 4 sqmm 4 core complete all as specified and as directed. Make:- National/Havells/Kalinga/Plaza |
| 57 | S&F AC stand wall mounted/floor mounted type suitable for existing type/Model of AC's complete all as specified and as directed by Engr-in-charge. |
| 58 | M&L for shifting of window/split AC's from existing loaction into new location dismantling of window/split AC's with electrical connection carefully and transported to New location as directed by the Engr-in-charge and cutting of window grill /brick wall including making good patches both the location & servicing of said AC's including point wiring suitable for window/split AC's not less than 2.5 sqmm complete all as specified and as directed. Note:- Copper conductor and fixing of ply for window AC's remaining area complete all as specified and directed by Engineer-in-charge. |
| 59 | S&F condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR split type AC suitable for working on R-32 Refrigerant in replacement of old unserviceable condenser complete all as specified and as directed. Note:- Supply and filling of refrigerant gas shall be measured and paid separately undrer respective item of this BOQ. |
| 60 | M&L for one 3 pin socket outlet 15 amps independent with cables of size 4 Sqmm in PVC conduit complete all as specified and directed by Enginer-in-charge. |
| 61 | Supply & fix in replacement of indoor unit suitbale existing type capacity of split AC's complete all as specified by Engr-in-charge (1.5/2TR) Make: Voltas/LG/Hi-Tachi |
| 62 | Supply & fix in replacement of outdoor unit suitbale existing type capacity of split AC's complete all as specified by Engr-in-charge (1.5/2TR) Make: Voltas/LG/Hi-Tachi |
| 63 | DESERT COOLERM&L for cleaning of water tank of desert coolers and cleaning of side panels with steel wire brush, scrapping old paint from complete desert cooler externally and internally and painting of the same with synthetic enamel paint (ash/hammerton epint) one coat extrernally with spray painting and one coat of water resistance paint inside over a suitable primer coat including replacement of internal wiring of suitable size complete all as specified and directed. |
| 64 | Taking down existing unserviceable fan copper motor assembly complete with blades mounting frame leg with rubber bush from desert coolers and S&F motor assembly complete with blades, mounting frames legs with rubber bus for desert cooler of capacity 3000/4000/50000 cum hrs and testing complete all as specified and directed by Engineer-in-charge. Make:- Usha, Crompton, Khaitan. |
| 65 | M&L for replacement of unserviceable /burnt submersible pump for desert cooler suitable for operation on 230 volts AC supply of capacity 18 watt complete all as specified and directed by Engineer-in-charge. Make:- USHA, Crompton, Khaitan. |
| 66 | Taking out with nylon threads suitable for any make of desert cooler and S&F wood wool pads with nylon threads suitable for any make of desert cooler having minimum maximum capacity 3000 cum/hr to 5000 cum hrs incuding S&F iron with PVC insulated protective guards for holding the wood pads firmly complete all as specified and as directed. |
| 67 | S&F in replacement of desert cooler body of capacity 4000 cum/hrs made out of galvanized iron sheets with bottom tank of 18 gauges, top cover of 20 gauge and side panels of 23 gauge GI sheet duly fitted with 1/3\\" thick wood wool pads including heavy duty 22 gauge frame grill burried with two nos piano type switches 5 amps complete all as specified and as directed. |
| 68 | All as per item No 67 above but 3000 cum/hr capacity complete all as specified and as directed. |
| 69 | S&F in replacement side panels for desert cooler of capacity 3000 cum/hr made with 22 gauge GI sheet as per existing size complete all as specified and as directed. |
| 70 | S&F in replacement side panels for desert cooler of capacity 4000 cum/hrs made with 22 gauge GI sheet as per existing size complete all as specified and as directed. |
| 71 | S&F in replacement side panels for desert cooler of capacity 5000 cum/hrs made with 22 gauge GI sheet as per existing size complete all as specified and as directed. |
| 72 | S&F in replacement of PVC water distribution system of desert coolers complete with PVC elbow, PVC pipe heavy duty 15mm dia complete all as specified and as directed. |
| 73 | S&F in replacement of three speed selector switch complete with knob of approved make for desert cooler complete ISI mark complete all as specified and as directed. |
| 74 | S&F in replacement of 15mm float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed. (Minimum wt 142 gms). Make: Prayag/Polytuff |
| 75 | Taking out the existing desert cooler from ground/1st floor for repairs & fixing only of desert cooler at ground/1st floor after servicing/repair at required position as including painting complete of existing MS angle iron stand as per existing colour all as directed and complete all as specified and directed. |
| 76 | S&F in replacement of damaged/rusted front grill suitable for 3000 to 4000 CFM capacity desert cooler made out of GI sheet of 20 gauge heavy duty complete with knob to separate the shutter and S&F one piano type switch and one three speed selector switch complete all as specifie and directed by Engineer-in-charge. |
| 77 | S&F in replacement electric cable PVC insulated rubber sheathed circular multistranded copper conductor of size 1.00 sqmm 3 core complete all as specified and as directed. Make:- National /Havells/Kalinga/Plaza. |
| 78 | S&F GI tubing 15mm bore in ground/1st floor with its connected fittings such as the elbows, nipple etc complete all as specified and as directed. |
| 79 | S&F in replacement of PTMT stop cock 15mm complete all as specified and as directed. Make: Prayag/Polytuff |
| 80 | S&F in replacement of PVC connection of size 15mm, 600mm long complete all as specified and as directed. Make:- Prayag/Polytuff |
| 81 | S&F in replacement of PVC connection of size 15mm, 900mm long complete all as specified and as directed. make:- Prayag/Polytuff |
| 82 | S&F in replacment of switch piano tyype 5 Amp complete all as specified and as directed. Make:- Anchor/Kinjal/Sanico |
| 83 | S&F in replacement of plug top 5 Amps complete all as specified and as directed. Make:- Anchor/Kinjal/Sanico |
| 84 | All as per item No 83 but 15 Amps complete all as specified and as directed. Make:- Anchor/Jindal/Sanico |
| 85 | VOLTAGE STABILIZER M&L for opening, dismantling, tracing the faults, repairing, servicing and re-assembling the voltage stabilizer suitable for 230 volts 50 Hz, AC supply single phase of capacity 4/5KVA complete all as specified and directed by Engineer-in-Charge. |
| 86 | S &F in replacement of new voltage stablizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 to 250 volt with output voltage stablizer at 230 V with accuracy of +2.5% & capacity 5KVA complete all as specified and directed by Engineer-in-Charge. |
| 87 | REFRIGERATOR S&F in replacemnt compresor 1/8 HP suitable for refrigerator of capacity 165 to 200 ltr. The work includes taking out the defective compresor and testing on completion complete all as specified and directed by Engineer-in-Charge. Make:- Techumesh/LG/Whirlpool. Note:- (a) Charing of gas R-134 shall be paid separately under respective item. |
| 88 | Description all as per ser item No 87 above but refigerator capacity 220 to 320 ltrs complete all as specified and directed by Engineer-in-Charge. |
| 89 | S&F in replacement of evaporator cooling coil of rferigerant 165 to 200 ltrs capacity complete all as specifed and as directed by Egnineer-in-charge. |
| 90 | S&F in replacement of evaporator cooling coil of refrigerant 220 to 320 ltrs capacity complete all as specified and as directed. |
| 91 | S&F in replacement of relay box type/open type suitable for 1/6 to 1/8 HP refrigerator of any make & size complete all as specified and directed by Engineer-in-Charge. Make:- Hitech/Renturol |
| 92 | S&F in replacement of overload protector suitable for refrigerator of any make & size complete all as specified and directed. |
| 93 | Taing out existing old rusted bottom body and frame door from refrigerator & M&L reparing of any size & capacity or referigerator body bottom and frame door with mild steel flat, angle iron & plain GI sheet of existing gauge by electric welding incuding preparation of surface and painting with spray paint on steel and iron surface of approved make complete all as specified and directed. |
| 94 | M&L for two coats of spray painting of refrigerator of any size make with synthetic enamel paint (GUCCO Delux paint) over existing surface. The work includes surface preparation filling of damaged portion complete all as specified and directed |
| 95 | Taking out burnt defective compressor 1/3 HP from deep freezer of capacity 425 ltr & S&F new compresor 1/3 HP capacity suitable for deep freezers 425 ltrs capacity of make Kelvinator/Ashoka including dehydrating of system and charging of comp oil & refeigerant gas complete all as specified and directed. Make:- Kirloskar/Techumesh |
| 96 | S&F in replacemernt of thermostatic switch for refrigerator of any make and 165 to 320 ltrs capacity complete all as specified and directed by Engineer-in-Charge. |
| 97 | Spply & fixing in replacemnet door gasket suitable for refrigerator of capacity 165/200 ltr single door complete all as specified and directed by Engineer-in-Charge. |
| 98 | Supply & fix in replacemnt door gasket suitable for refrigerator of capacity 286/300 ltrs single door complete all as specified and directed by Engineer-in-Charge. |
| 99 | Supply & charging the refrigerant gas R-134A in refrigerator of capacity 200 to 320 ltrs including testing complete all as specified and directed. |
| 100 | Supply & charging the refrigerant gas R-134A in deep freezerr of capacity 200 to 425 ltrs including testing complete all as specified and directed. |
| 101 | WATER COOLER Servicing and cleaning of water cooler 40 to 80 ltf capacity form inside and outside with potassium permagnate including servicing of fan motor, condensoer, fan balde and its connected water and refrigerant fitting and testing water tank leakage complete all as specified and directed Note:- S&F of spare parts required for smooth fuctioning of the machine shall be measured and paid for separately under respective items. |
| 102 | Description all as per item No 101 above but capacity 120 to 150 lts complete all as specified and directed. |
| 103 | S&F new compressor in replacement suitabel for 40 to 80 ltrs capacity water coolers any make. Re-fixing on its original position and testing for smooth functioning complete all as specified and directed. Note:- Supply & charging of gas R-22/R-1348 shall be measured and paid separately under respective item. |
| 104 | Description all as per item No 103 above but capacity 120 to 150 ltrs complete all as specified and directed. |
| 105 | M&L for charging refrigerant gas R-22 in the water cooler of any make 40 to 80 ltrs capacity including testing and detecting leakage with nitrogen gas and vaccum the system complete all as specified and directed by Engineer-in-charge. |
| 106 | Description all as per ser item No 105 above but capacity 110 to 150 Ltrs complete all as specified and directed. |
| 107 | M&L for charging refrigerant gas R-134A in the water cooler of any make of capacity 40 to 80 ltrs including testing and detecting leakage with nirogen gas and vaccum the system complete all as specified and directed by Engineer-in-charge. |
| 108 | Description all as per ser item No 107 above but capacity 120 to 150 ltrs complete all as specified and directed. |
| 109 | S&F in replacement of overload relay box type of make Shriram/Renutrol suitable for water cooler complete all as specified and as directed by Engineer-in-charge. |
| 110 | S&F in replacement of thermostat switch make Danfoss/Renutrol suitable for water cooler of any make and size complete all as directed by Engineer-in-charge |
| 111 | S&F in replacement of starting relay suitable for water cooler of make Usha/Sriram/Renutrol/Classic complete all as specified and directed. |
| 112 | S&F in replacement of overload relay of make Classic/Renutrol No 1022/522 complete all as specified and as directed. |
| 113 | M&L for spray painting of water cooler of any make and capacity 40 to 80 ltrs as per existing colour after scraping the old damaged paint, making good to the disturbed surface to match with the existing surface and shade with synthetic enamel paint complete all as specified and as directed. |
| 114 | Description all as per ser item No 113 above but capacity 120 to 150 ltr complete all as specified and directed. |
| 115 | S&F in replacement of defective push cook 15mm dia chromium plated heavy duty suitable for water cooler of any make complete all as specified and as directed by Engineer-in-charge. |
| 116 | S&F in replacement of PVC float valve assembly 15mm dia for water cooler of any make 40 to 80 ltrs capacity complete all as specified and directed. |
| 117 | S&F in replacement of PVC float valve assembly 15mm dia for water cooler of any make 120 to 150 ltrs capacity complete all as specified and directed. |
| 118 | S&F in replacement of running capacitor 25 mfd complete all as specified and as directed by Engr-in-Charge. Make:- Usha/Tibcon/Havells |
| 119 | M&L in replacement of water cooler base including fabrication with angle iron frame, bottom base MS sheet of 15 gauge including welding brazing replacement of MS hinge half swing of top cover, top gasket all as per site requirement incuding paitning over a coat of red oxide primer complete all as specified and as directed by Enginer-in-charge. |
| 120 | S&F new fan motor suitable for water cooler of capacity 40 to 80 ltrs complete all as specified and as directed. |
| 121 | Description all as per ser item No 120 above but capacity 120 to 150 ltrs complete all as specified and directed. |
| 122 | S&F in replacement of aluminium fan blade suitable for 40 to 80 ltrs of water cooler complete all as specified and directed. |
| 123 | Description all as per ser item No 122 above but capacity 120 to 150 ltrs complete all as specified and directed. |
| 124 | S&F in repalcement of condenser copper tubing with aluminium fins suitable for 40 to 80 ltr capacity water cooler complete all as specified and directed. |
| 125 | Description all as per ser item No 124 above but capacity 120 to 150 ltrs complete all as specified and directed. |
| 126 | M& for rewinding and repairing of fan motor suitable for water cooler of capacity 40 to 80 ltrs of any size with super enamelled copper conductor of existing gauge complete all as specified and as directed. |
| 127 | Description all as per ser item No 126 above but capacity 120 to 150 ltrs complete all as specified and directed. Please Enable Macros to View BoQ information |