Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #55928188

Tender For Special Repair To Address Seepage Issues In Tower Sm-392 At Goswami Enclave Under Ge (Awc) Mhow

Issued by Statutory Bodies & Commissions/Committees · GE (AWC) Mhow, Madhya Pradesh
Tender Value
30.39 Lakhs
Estimated cost
Bid Submission
09 Jul 2026
4 days left
EMD
60780
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
GE (AWC) Mhow → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Special Repair To Address Seepage Issues In Tower Sm-392 At Goswami Enclave Under Ge (Awc) Mhow

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 02-Jul-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-Jul-2026

BOQ

Name of Work:- SPL REAPAIR TO ADDRESS SEEPAGE ISSUES IN TOWER SM-392 AT GOSWAMI ENCLAVE UNDER GE (AWC) MHOW
Sl. No. Item Description
1M & L for repair to sunken floor by provide water proofing treatment to sunken floor surfaces of RCC slab by the following specifications as specified and directed :- (a) Provide PCC 1 : 1.5 : 3 type A with using 12.5mm graded stone aggregate in slope of average thickness 50mm on sunken floor slab mixed with and including integral water proofing compound manufactured by Dr FIXIT or equivalent as approved, finish the surface even & smooth without using extra cement.(b) Rendering 15mm thick in CM 1:3 mixed with & including integral water proofing compound on sunken floor and sides of (Vertical surface) sunken portion.(c) Applying surfaces of bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm complete. on complete sunken surfaces of floor & wall and provide necessary connections to soil/waste pipe from WC/ nahani trap etc including demolation of old sunken complete all as specified and as directed. (d) Applying a tack coat of Industrial bitumen grade of 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces (1st coat for bonding material below membrane and 2nd coat on top of membrane. Each coat would be paid seperately.) (e) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed. Note : Floor Area shall be measured for payment.
2M & L PCC 1:5:10 type E-2 using 40 mm graded stone aggregate as in mass concrete complete all as specified and directed.
3M & L rendering 10 mm thick on brick wall/cement block wall or concrete surfaces in cement mortar 1:6, surfaces finished even and smooth without using extra cement complete including taking down cement plaster on brick or stone walls/ concrete surface, etc. all as specified and as directed.
4M & L rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceiling surface finish even and smooth without using extra cement including taking down cement plaster on brick or stone walls/ concrete surface, etc. complete all as specified and directed..
5Supply only Integral water proofing compound complete all as specified and directed.
6M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistance primer over a coat of putty complete all as specified and directed.
7M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
8M& L in repair for preparation of surface for application of water based epoxy resin coating of waterproofing for internal wall dampness and filling of cracks and making the surface smooth and finish complete all as specified.Note : (a) Complete removal of treatment/plaster(where needed) on internal walls and preparation of surface for application and making the surface wet .(b) apply first coat of Dr. fixit Dampguard in ratio(1U base:1U hardner:1U water) in one direction and leaving the coat to dry for 6 to 8 hrs.(c) apply second coat of Dr. fixit dampguard in ratio(1U base:1U hardner:1U water) in perpendicular direction to the first coat applied and leaving the surface to dry for 24 hrs. Material: Dr. fixit Dampguard or equivalent.
9Description all as per ser item No. 7.00 above but one coat of white wash on ceiling complete all as specified and as directed.
10M & L for complete removal of existing treatment on walls and evenly applying two coat of oil bound distemper with roller over a coat of putty all as specified and directed.( Note: putty will be measured and paid seperately in relevant item.)
11M&L for applying 1 mm thick wall care putty ( JK / Birla) on wall on internal old/new wall surfaces as per manufacturerer instruction complete all as specified and as directed.
12M & L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm , in floors etc.set jointed in neat cement sluury and pointed in white or coloured cement to match over & incl 15 mm thick screed bed built in CM 1:6, including dismanling floor,hearth or wall tiling including cement mortar bedding (but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
13M&L glazed ceramic coloured tiles size 300mm x 450 mm 6-7 mm thick (Colour and design of tiles as approved by GE) on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, including dismanling floor,hearth or wall tiling including cement mortar bedding (but not backing),removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
14M & L 25 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including finishing surface of concrete topping even and rough complete as in levelling work etc, complete all as specified and directed.
15M & L for provide PVC spout pipe of 25mm bore & 45cm length in sunken floor including cutting holes in brick walls built in cement mortor and making good the dismantled portion in PCC (1:2:4), type B1 with using 20mm graded stone aggregate with wall finish at the disturbed portion of external surfaces complete as directed and specified.
16M & L for cutting holes in brick walls built in cement mortor at the starting point of down take soil/waste pipe at any floor, fill the joint of down take pipe & trap with thick mortor in CM 1:3 and making good the dismantled portion in PCC (1:2:4), type B1 with using 20mm graded stone aggregate with wall finish at the disturbed portion of external surfaces complete as directed and specified.
17S & F in repairs vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of tap, waste fitting etc complete.. Note :- Pillar tap shall be measured as supply only under respective item.
18S & F in repairs of padestal pattern Vitreous china wash down water closet pan white including trap,PVC seat cover white, connection to drain (or out going pipe ) and to flushing pipe antisyphone pipe etc complete.
19S&F in repairs brass chromium plated bib tap for iron pipe of 15mm bore fancy type long body , screwed down high pressure complete all as specified.
20S & F in repair of 15mm bore, 450mm long, PVC connections with brass unions internally threaded both ends complete fixed to iron pipe at both ends complete all as specified and directed.
21S & F in repair of CP fancy type angle valves,cast copper alloy, screwed both ends for iron pipe or for union of 15mm bore complete all as specified and directed.Make: Essco series of Jaquar or equivalent series as per list of makes att.
22S & F in repairs of CP Fancy type shower rose 75 mm dia with 125mm long CP Nipple of approved quality complete all as specified and directed.Make: Essco series of Jaquar or equivalent series as per list of makes att.
23S&F in repair 15 mm bore basin mixture Fancy Type brass chromium plated with capstan heads screwed down high pressure with or without letter ‘HOT’ or ‘COLD’ with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and directed.
24S & F in repair Sink Mixer 15 mm CP Fancy exclusive type as per direction by Engg-in-charge, complete all as specified and directed.
25S & F in repairs of Wall mixture CP hot & cold, 15mm bore, bright finish with three joints screwed the ends for iron pipe and plugging complete all as specified and directed. Make: Essco series of Jaquar or equivalent series as per list of makes att.
26S&F in repairs of health faucet with S.S. flexible pipe of 1.00 metre length including holder complete all as specified and as directed.Make: Essco series of Jaquar or equivalent series as per list of makes att.
27S&F in repairs of fancy type chromium plated two way bib cock of 15mm bore ,screwed for iron pipe or brass ferrule etc complete all as specified and as directed.
28S& F in repairs of sheet glass shelf assembly, approved make, consisting of 5.5mm thick sheet glass shelf 60mm wide with chromium plated bracket guard and railing 500mm long complete all as specified & directed.
29S&F in repairs corner glass shelf 5.5mm thick with aluminium bracket and railing as per sample, complete all as specified and as directed.
30S&F in repairs of Bevelled edge mirror of 5 to 6 mm thick selected quality glass of size 600 x 450 mm mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with Chromium Plated brass screw and cup washers complete complete all as specified & directed.
31S & F in repair of PVC body bathroom cabinet with mirror fancy type made out of 5.5mm thick mirror of size 550 x 450mm complete all as specified and directed.
32S & F in repair of plastic water closet seat cover white closed pattern with flat bottom and cover with mild steel/ chromium plated or aluminised hinging device complete all as specified and directed.
33S & F in repair of flush pipe of polyethylene of low or high density or PVC, 32mm dia for low level flushing cistern/basins complete as complete all as specified and directed.
34Supplying and laying of CPVC pipes 15mm SDR 13.5 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; andcutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girthcomplete all as specified.
35Supplying, fixing, jointing and testing galvanised steel water tubing medium grade with all fittings such as bend, elbow, socket reducer etc fixed to walls and ceilings or laid in floors, complete for the following sizes: -
36(a) 20 mm dia bore
37(b) 25 mm dia
38S&F in repairs 18 mm thick factory made PVC sheet one side pre-laminated sheet kitchen cabinet shutter. The 18mm thick sheet shutter bent at 90 degree and finish all edges at level for marking edge lapping bending for 0.5 mm thick PVC sheet lapping at all four edges using bonding tape etc complete including taking down all as per specified and directed by Engr-in-Charge manufacturers specification, complete all as specified and directed.
39S&F 100mm size MS mat/glossy finish handle complete as specified and directed.
40S&F stainless steel self closing hinge of 75mm size for PVC door shutter complete as specified and directed.
41S&F 50x15mm size magnet door catcher for closing for PVC door shutter complete as specified and directed.
42S&F mild steel drawer cabinet channel for moving the drawer etc complete as specified and directed.
43S&F in repair of stainles steel gratings round type 100mm size of (Min Weight 100 gms) complete all as specified and directed.
44S&Fin repair of PVC valveless, syphonic action type flushing cistern,low/high level white with inlet ball valve float and handle including brackets complete fixrd in repair capacity of flush 10 ltrs complete all as specified and directed.
45S & F in repair of SS waste coupling (Half/Full thread) 32mm complete all as specified and directed.
46S & F in repairs of internal fitting(including syphon, ball valve, lever, rubber cone etc) for single flush cistern complete all as specified and directed.
47Taking up or down steel tubing 15mm bore & connections and S & F GI tubing medium grade with all fittings & fixed complete to walls /ceiling or laid in floors all complete all as specified and directed.
48Taking up or down steel tubing 20mm bore & connections and S & F GI tubing medium grade with all fittings & fixed complete to walls /ceiling or laid in floors all complete all as specified and directed.
49S&F in repair of gun metal gate valves 15 mm with lever arm screwd both ends for iron pipes complete all as specified and directed.
50S & F factory made 100% solid WPC (Wood polymer composite) Door frame 90mm X 45mm (Moulded) single rebated made from wood polymer composite (single extruded process material comparison of virgin PVC polymer of k value 57-60 (Suspension grade), calcium carbonate and natural fibers (Wood powder/rice husk/wheat husk) and Non toxic additives fabricated with meter joints after applying PVC solvent cement & screwed with full body treaded star headed screws having minimum frame density of 750 kg/ cbm, an ISO 9001-2015 certified company , having good screw holding capacity (screw withdrawal strength of (Min 990 N ), minimum compressive strength of 58n/mm2, Modulus of elasticity 900N mm2 and resistance to spread of flame of class A category with property of being Termite/ borer proof , water/ moisture proof and fire retardant & fixed with position with SS dash fasteners / Hold fast of required dia and length , all as per specifications drawings as directed by the Engineer-In-charge ,Material test certificate and authentication should be compulsory provided by the manufacturing company including hold fast or fasteners, complete all as specified and as directed.
51S & F factory made 30 mm thick 100% solid WPC (wood polymer composite) laminated flush door shutter of required size comprising of virgin PVC resin of K value 57-60 ( suspension grade), Calcium carbonate and natural fibers ( Wood powders / rice husk/wheat husk) and non toxic additives made from extension process WPC foam sheet single extruded (Inner) with having minimum density not less than 650 kg kg/cbm, an ISO 9001-2015 certified company , having good screw holding capacity (Screw withdrawal strength of 200 N (Face) & 1100 N (Edge) minimum compissive of 50N/mm2 Modulus of elasticity 850N/mm2 and resistance of spread of flame of class A category property of being Termite/ borer free , water/ moisture proof and fire retardant WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixing stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws , all as per direction of Engineer-In-charge ,Material test certificate and authentication should be compulsory provided by the manufacturing company, complete all as specified and as directed.
52Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each and all as specified and directed.
53S & F in repairs for 100mm long butt hinges medium weight cold rolled mild steel complete all as specified
54S & F in repair aluminium 150 mm long anodised barrel tower bolts with cast or sheet barrel and rolled cast bolts and fixed, complete all as specified and directed.
55S & F in repair 150 mm size aluminium handles cast type, anodisedwith cast or sheet barrel and rolled cast bolts and fixed, complete all as specified and directed.
56S & F in repair 250 mm aluminium , anodised sliding door bolt ISI marked with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast brass and fixed, complete all as specified and directed.
57S&F in repair of 110mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall / floor with clip complete all as specified and directed..
58S&F in repair of 75mm bore of PVC (SWR) pipes single socketed in any length with rubber ring joints laid on wall / floor with clip complete all as specified and directed..
59S&F in repair of PVC ( SWR) bends any radius bore of 110 mm all as specified and directed
60S&F in repair of PVC ( SWR) bends any radius bore of 75 mm all as specified and directed
61S&F in repair of PVC (SWR) branch piece, single (single Y) equal or unequal of bore 75mm all as specified and directed.
62S&F in repair of PVC (SWR) branch piece, single (single Y) equal or unequal of bore 110 mm all as specified and directed.
63S&F in repair of PVC (SWR) junction single, (Single T) equal or unequal of bore 75mm all as specified and directed.
64S&F in repair of PVC (SWR) junction single, (Single T) equal or unequal of bore 110 mm all as specified and directed.
65S&F in repair of PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed.
66S&F in repair of PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement all as specified and directed.
67S&F in repair of Flush pipes to pedestal pan, including all joints all as specified and directed.
68S&F in repair of Flush pipes to squatt pattern closet including all joints and making good to the floor all as specified and directed.
69S&F in repair Cones, India rubber nozzles of W.C. pans all as specified and directed.
70S&F in repair kitchen sink with drainage board made of stainless steel 1.0 mm thick in kitchen with plug , washer and waste including bedding layer in CM (1:6) in wall or including fixing cantilever bracket and connecting union to pipes over all size 915x460 mm bowl size 410x330x160 mm including taking out unserviceable kitchen sink complete all as specified and as directed.
71Cleaning and removing all scale and dirt and elgy using wire/jute from inside of RCC /PVC tanks and connected pipe removing to a distance of not less than 250 mtrs,washing the tank/ipe with bleaching powder solution and finally applying 2% potassium permangnate solution for disinfection,including marking with black/white paint on white/black base on tank \\"Tank cleaned on________Dt________\\" exc 5000 litre & n.exc 10000 litre complete all as specified and directed.
72M & L washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed.Note:- 1. Payment for providing grooves shall be made separately. 2. Work to be executed up to 7 Story building height.
73S&F PVC waste pipe fixed to any type of coupling of 32 mm threaded complete all as specified and directed.
74Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face, complete all as specified and directed.Note: Work to be executed up to 7 Story building height.
75M&L Green marble 18 to 20 mm thick(of any type) work (table rubbed and polished) for wall lining (Veneering to wall) and laid on cill of parapet wall / floor / dado over 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of marble colour as per direction of GE, including demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar, complete all as specified and directed.Note : Cutting of marble are included in this rate.
76Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
77Taking down exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M complete all as specified and as directed.
78Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
79Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed.
80Taking down carefully wall light fitting of any type from wall / roof without disturbing the wall / roof and keeping in safe custody for reuse complete all as specified and directed.Note :- Any damage during taking dwon wiil be rectified by the contractor at his own arrangement.A penalty of Rs 500/- per fitting shall be deducted for any minor damages if any. Major damage is caused wiil be repair & replaced by the contractor at his own cost.
81Taking down carefully geyser froom wall of any height without disturbing the wall / roof and keeping in safe custody for reuse complete all as specified and directed.Note :- Any damage during taking dwon wl be rectified by the contractor at his own arrangement.A penalty of Rs 1500/- per geyser shall be deducted for any minor damages if any. Major damage is caused wl be repaired & replaced by the contractor at his own cost.
82Labour only for point wiring with 1.5 sqmm Inominal cross sectional area) single core, PVC insulted, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through in existing non metalic rigid non metallic PVC conduit (Medium grade) concrealed in wall / ceiling with and including 1.5 sqmm single core PVC insluted, multistraneded unsheathed , FRLSH copper conductor cable as continious earth continuity conductor (green in colour ) all as specirfied and directed for the followoingNote :- All items incorporated will be from taking down items as mentioned in item No 74.00 here in above(Description contd ser item No. 80.01, 80.02, 80.03 separately)
83One light point controlled by one, one way switch 5/6 Amps
84One ex fan point controlled by one, one way 5/6 amps switch
85One 3 pin, 5/6 amps socket outlet point on independent board controlled by one, one way 5/6 amps switch.
86Labour only for point wiring with 2.5 sqmm Inominal cross sectional area) single core, PVC insulted, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through in existing non metalic rigid non metallic PVC conduit (Medium grade) concrealed in wall / ceiling with and including 2.5 sqmm single core PVC insluted, multistraneded unsheathed , FRLSH copper conductor cable as continious earth continuity conductor (green in colour ) all as specirfied and directed for the followoingNote :- All items incorporated will be from taking down items as mentioned in item No 74.00 here in above
87M&L for removing carefully modular metal flush box of any module incl cover plated and cover frames from existing wall by cutting and refixing the same in a level refixing all items obtained from taken down (item No 78.00) such as switches, sockets, fan regujlator, ceiling rose complete incl refixing cover plate and frame incl making good disturbed surface of wall by cement plastering , putty finishing to match with the existing surfaces complete all as specifed and directed.Note:- A penalty of Rs 90/- per fitting shall be deducted for any minor damages if any. Major damage is caused wl be repaired & replaced by the contractor at his own cost. Please Enable Macros to View BoQ information
88M&L for removing carefully modular metal flush box of any module incl cover plated and cover frames from existing wall by cutting and refixing the same in a level refixing all items obtained from taken down (item No 78.00) such as switches, sockets, fan regujlator, ceiling rose complete incl refixing cover plate and frame incl making good disturbed surface of wall by cement plastering , putty finishing to match with the existing surfaces complete all as specifed and directed.Note:- A penalty of Rs 90/- per fitting shall be deducted for any minor damages if any. Major damage is caused wl be repaired & replaced by the contractor at his own cost. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55928188
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30.39 Lakhs
LAST DATE 09-07-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Address Seepage Issues In Tower Sm-392 At Goswami Enclave Under Ge (Awc) Mhow
Basic Detail
Tender No 8953/AWC/MHOW/ OF 2026-27
Bidding Type Tender
Location
City GE (AWC) Mhow
State Madhya Pradesh
Key Dates
Publish Date 02 Jul 2026
Submission Date 09 Jul 2026
Open Date 11 Jul 2026
Finance
Tender Value 30.39 Lakhs
Tender Fee 500
EMD 60780
Exemption Not Available
Document List
1a29ce05-c681-4525-86b1-9e4f834f5041.html
BOQ_863637.xls
listofmake.pdf
Tdocus.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Jul 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Jul 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

1a29ce05-c681-4525-86b1-9e4f834f5041.html

xls

BOQ_863637.xls

pdf

listofmake.pdf

pdf

Tdocus.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders