Tender For Provision Of Otm Accommodation Of Fd Hosp At Saugor Mil Stn.
BOQ
| Sl. No. | Item Description |
| 1 | Note:-1. Please refer schedule 'A' notes before quoting the tender. 2. Amount of schedudle of credit shall be deducted offline by department . |
| 2 | GENERAL SUMMARY |
| 3 | Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’ Part-I (Ref prepriced schedule attached seperately) |
| 4 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART- II (INTERNAL WATER SUPPLY WORKS) as listed in Schedule ‘A’ Part- II (Ref prepriced schedule attached seperately) |
| 5 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-III (INTERNAL ELECTRIFICATION WORKS ) as listed in Schedule ‘A’ Part -III (Ref prepriced schedule attached seperately) |
| 6 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-IV (EXTERNAL WATER SUPPLY WORKS ) as listed in Schedule ‘A’ Part -IV (Ref prepriced schedule attached seperately) |
| 7 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-V (EXTERNAL ELECTRIC SUPPLY WORKS ) as listed in Schedule ‘A’ Part -V (Ref prepriced schedule attached seperately) |
| 8 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-VI (ROAD, PATH AND CULVERT WORKS) as listed in Schedule ‘A’ Part-VI (Ref prepriced schedule attached seperately) |
| 9 | Lump sum price worked out by the contractor for SCHEDULE 'A' PART-VII (AREA DRAINAGE WORKS) as listed in Schedule ‘A’ Part-VII (Ref prepriced schedule attached seperately) |
| 10 | Lump sum price worked out by the contractor for SCHEDULE 'A' PART-VIII (SEWAGE DISPOSAL WORKS) as listed in Schedule ‘A’ Part-VIII (Ref prepriced schedule attached seperately) |
| 11 | Lump sum price worked out by the contractor for SCHEDULE 'A' PART- IX (FENCING, GATE, SECURITY WALL and COMPOUND WALL WORKS) as listed in Schedule ‘A’ Part-IX (Ref prepriced schedule attached seperately) |
| 12 | Lump sum price worked out by the contractor for SCHEDULE 'A' PART-X (LIGHTNING PROTECTION WORKS) as listed in Schedule ‘A’ Part-X (Ref prepriced schedule attached seperately) |
| 13 | Lump sum price worked out by the contractor for SCHEDULE 'A' PART- XI (FLAME PROOF LIGHT WORKS) as listed in Schedule ‘A’ Part-XI (Ref prepriced schedule attached seperately) |
| 14 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-XII (CONDUIT FOR TV & TELEPHONE EXTERNAL SERVICES WORKS) as listed in Schedule ‘A’ Part-XII (Ref prepriced schedule attached seperately) |
| 15 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-XIII (RAIN WATER HARVESTING WORKS) as listed in Schedule ‘A’ Part-XIII (Ref prepriced schedule attached seperately) |
| 16 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART-XIV (GREEN BUILDING NORMS (GRIHA) (SOLAR PV SYSTEM) WORKS) as listed in Schedule ‘A’ Part-XIV (Ref prepriced schedule attached seperately) |
| 17 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – XV ( DEMOLITION / DISMANTLING WORKS) as listed in Schedule ‘A’ Part- XV (Ref prepriced schedule attached seperately) |
| 18 | Lump sum price worked out by the contractor for SCHEDULE ‘A’ PART – XVI (EXCAVATION, EARTH WORK & SITE CLEARANCE WORKS) as listed in Schedule ‘A’ Part-XVI (Ref prepriced schedule attached seperately) |
| 19 | SCH 'A' Pt - XVII (MISCELLANEOUS ITEMS) |
| 20 | INTERNAL ELECTRIFICATION WORKS NOTE:- For items of INTERNAL ELECTRIFICATION WORKS notes given at the beginning of Sch ‘A’ Part-III ( INTERNAL ELECTRIFICATION WORKS ) shall also be applicable. |
| 21 | Supply and fixing study lamp wall mouned type upon table including LED lamp 9 watt for study lamp fitting complete all as specified and directed. |
| 22 | S&F Wall mounted air circulator copper wound, double ball bearing of size 600 mm, 220-240 volts, air delivery not less than 250 CMM & power consumption not more than 200 watt, metal body painted with metallic powder coated anti corrosion paint alongwith necessary fixing arrangement and connecting cable from ceiling rose complete all as specified and directed. |
| 23 | EXT WATER SUPPLY WORKS NOTE:- For items of EXT WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-IV (EXT WATER SUPPLY WORKS) shall also be applicable. |
| 24 | Supply, laying, connecting, jointing and testing Centrifugally cast (spun) 100mm dia ductile iron pressure pipe ISI Marked conforming to IS-8329-2000 ( Reaffirmed -2005 Edition 4.1 ) of following size with socket spigot ends, suitable for \\"Push on Joints ( Tyton Joint )\\" each standard working lengths supplied with rubber gaskets duly ISI marked for water supply, Class K-9 with socket with cement mortar lining inside and metallic Zinc coating with finishing layer of bituminous paint on outside the pipe with out polythylene sleeves but including \\"Push on Joint\\" supplied with ISI Marked EPDM rubber gasket conforming to IS-5382-1985 ( reaffirmed-2003 ) laid in trenches complete all as specified and directed |
| 25 | Supply, laying, connecting, jointing and testing centrifugally cast (Spun) 80mm dia Ductile iron Pressure pipe ISI Marked conforming to IS-8329-2000 ( Reaffirmed -2005 Edition 4.1 ) of following size with socket spigot ends, suitable for \\"Push on Joints (Tyton Joint )\\" each standard working lengths supplied with rubber gaskets duly ISI marked for water supply, Class K-9 with socket with cement mortar lining inside and metallic Zinc coating with finishing layer of bituminous paint on outside the pipe with out polythylene sleeves but including \\"Push on Joint\\" supplied with ISI Marked EPDM rubber gasket conforming to IS-5382-1985 ( reaffirmed-2003 ) laid in trenches complete all as specified and directed. |
| 26 | M&L for bends (any type, radius and angle) tapers and y type, (straight, bends increasing, decreasing or double socket etc.( Tee pieces single branch, 'Y' junction, double branch, cross (all socketed or socket and spigot) collars caps and plugs complete all as specified and directed. |
| 27 | M&L for construction of brick masonry valve pit chamber of size 1200 x 1200 x 1000mm including necessory earth work, PCC, copings plastering on internal surfaces of valve pit. Framed work for the valve pit chamber cover made of MS sheet 3mm thick conforming to Fe410-o and Fe 310-o, angle of size 40 x 40 x 5mm including welding, cutting, hinges locking arrangement complete and applying two coats synthetic enamel paint over a coat of red oxide primer on the valve pit cover complete all specified and directed. |
| 28 | M&L for construction of brick masonry valve pit chamber of size 900 x 900 x 1000mm including necessory earth work, PCC, copping, plastering on internal surface of valve pit. Framed work for the valve pit chamber cover made of MS sheet 3mm thick confirming to Fe410-o and Fe 310-o, angle of size 40 x 40 x 5mm including welding, cutting, hinges locking arrangement complete and applying two coats synthetic enamel paint over a coat of red oxide primer on the valve pit cover complete all specified and directed |
| 29 | EXTERNAL ELECTRIC SUPPLY WORKS NOTE:- For items of EXTERNAL ELECTRIC SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-V ( EXTERNAL ELECTRIC SUPPLY WORKS) shall also be applicable. |
| 30 | Taking down old unsv LT cable of any size complete all as specified and directed. |
| 31 | S&F for supply, install, connecting and commissioning of CPRI approved main LT distribution panel board ( MAIN LT PANEL 1 ) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer, prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole,200 Amps,25 kA at 415V with rupturing capacity 25 KA-01Nos (B) OUTGOING(i) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated Aluminium busbar, for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 100 Amps with rupturing capacity 25 KA-01 Nos(v) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 16 KA-02 Nos(vi) MCB, 4 POLE of capacity 32 AMPS,10 kA - 02 Nos(vii) 3 phase street light timer of capacity 5 KW at 415V - 01 Nos |
| 32 | M&L for supply, install, connecting and commissioning of CPRI approved main LT distribution panel board (LT PANEL 1) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer, prewired with suitable size of copper cable/insulated copper strip including PCC work and iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 125 Amps with rupturing capacity 36 KA-01Nos(B) OUTGOING(i) Digital Multifunction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated copper busbar, for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 100 Amps with rupturing capacity 16 KA-01 Nos(v) MCB SPN of capacity 32 AMPS - 02 |
| 33 | M&L for supply, install, connecting and commissioning of CPRI approved main LT distribution panel board (LT PANEL 2) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 100 Amps with rupturing capacity 36 KA-01Nos (B) OUTGOING(i) Digital Multifunction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated copper busbar, for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 16 KA-01 Nos(v) MCB SPN of capacity 32 AMPS,10 kA - 02 Nos |
| 34 | M&L for supply, install, connecting and commissioning of CPRI approved main LT distribution panel board MAIN LT PANEL 2) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 300 Amps with rupturing capacity 36 KA-01Nos (B) OUTGOING(i) Digital Multifunction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated aluminium busbar, for three phases and neutral -01 set(iv) MCCB, 4 POLE of capacity 250 AMPS, 25 kA at 415V = 01 Nos(v) MCCB, 4 POLE of capacity 63 AMPS, 10 kA at 415V = 02 Nos |
| 35 | M&L for supply, install, connecting and commissioning of CPRI approved main LT distribution panel board (LT PANEL 3) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 250 Amps with rupturing capacity 36 KA-01Nos(B) OUTGOING(i) Digital Multifunction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated copper busbar, for three phases and neutral -01 set(iv) MCCB, 4 Pole,415V, 50HZ 63 Amps with rupturing capacity 16 KA-02 Nos(v) MCCB 4 Pole of capacity 40 AMPS,10 kA at 415V = 01 Nos(vi) MCB SPN of capacity 32 AMPS = 02 Nos |
| 36 | M&L for supply, install, connecting and commissioning of CPRI approved main LT distribution panel board (LT PANEL 4) , outdoor type, both side openable including locking arrangement with sliding door bolt , cubical type, 3 phase, 4 wire, 415V, factory made free standing, floor mounting, dust and vermin proof, cubical type, fabricated from 3.15 mm thick MS sheet with anticorrosive coating and finally epoxy polyster powder coating of flint grey shade fully compartmentalised design with 4 Nos insulated bus bar each made of high conductivity aluminium of size not less than 1.25 times of main incomer prewired with suitable size of copper cable/insulated copper strip including PCC work and Iron work for fixing arragement at site suitable earth strips conforming to IS, cable glands, lugs etc suitable for and comprising of the following.(A) INCOMING(i) MCCB, 4 Pole, 415V, 50HZ 63 Amps with rupturing capacity 10 KA-01Nos(B) OUTGOING(i) Digital Multifuction meter with selector switch and three current transformers of suitable ratio and capacity -01 Set(ii) LED type Phase indicator lamps for three phases set of three - 01 set(iii) Busbar chamber having insulated copper busbar, for three phases and neutral -01 set(iv) MCB, 4 Pole,415V, 50HZ 40 Amps with rupturing capacity 16 KA-02 Nos(v) MCB SPN of capacity 32 AMPS = 02 Nos |
| 37 | S&F junction box single pole and neutral enclosure compression gland 2 with connector and clamp for pole mounting with two nos of nut bolt and washers and socket complete of size not less than 12 \\" x 10\\" x4\\" complete all as specified and directed by Engr-in-Charge . |
| 38 | S&F tubes galvanised 40mm bore light grade ISI Marked bent to shape of bracket 1.2 mtr in length for mounting of street light fitting and fixed to pole with clamps, nut bolts and washerand applying two coats synthetic enamel paint over a coat primer on steel surfaces including preparation complete all as specified and directed. |
| 39 | S&F HT cable route indicator made of RCC M15 (Nominal Mix) type B0 (using 12.5mm graded crushed stone aggregate) of size 200mm(Length) x 200mm (Width) x 1200mm (Height) duly painted with cement base and written in white colour with lettering MES HT cable/HT Straight joint using two coats of synthetic enamel paint in black colour and including neccesary earthwork and excavation, embedded in PCC M15 (Nominal Mix) type B1 (using 20mm graded crushed stone aggregate) of size 400mm x 400mm x 300mm complete all as specified and directed. |
| 40 | ROAD, PATH AND CULVERTS WORKS NOTE:- For items of Road, Path and Culverts notes given at the beginning of Sch ‘A’ Part-VI ( Road, Path and Culverts) shall also be applicable. |
| 41 | M&L for thermo plastic center or edge line marking (reflective type) of 3mm thickness of uniform finishing with machine conformiong to BS 3262 (Part-I) 1989 read with most specification of 803 clause 4.2.1 and 4.2.2 on bituminous surface in white/yellow/red colour and super imposed with glass slam beats confirming to BS 6088 and most specification 803 clause 4.3.3 including cleaning of surface by removing all dust, dirt oil grease etc inclduing removing of existing marking with spirit/keroscene/gas burner or mechanically on bituminous surface complete all as specified and directed. |
| 42 | SEWAGE DISPOSAL NOTE:- For items of Sewage Disposal notes given at the beginning of Sch ‘A’ Part-VIII ( Sewage Disposal) shall also be applicable. |
| 43 | S&F HDPE double wall corrugated sewage pipe 150mm internal bore SN-8 ISI Mark as per IS: 6908 Part II 2013 laid in trenches joined and tested as per manufacturer's instructions complete all as specified and directed. |
| 44 | (CONDUIT FOR TV & TELEPHONE WIRING WORKS) NOTE:- For items of CONDUIT FOR TV & TELEPHONE WIRING WORKS notes given at the beginning of Sch ‘A’ Part-XII ( CONDUIT FOR TV & TELEPHONE WIRING WORKS) shall also be applicable. |
| 45 | S&F RJ 11 telephone socket with shutter, 1 module including modular cover plate, metal flush box (16 gauge) concealed in wall/roof complete all as specified and directed. |
| 46 | S&F RJ 45 computer jack with cat No 6 socket, 1 module including modular cover plate, metal flush box (16 gauge) concealled in wall/roof complete all as specified and directed. |
| 47 | RAIN WATER HARVESTING WORKS NOTE:- For items of RAIN WATER HARVESTING WORKS notes given at the beginning of Sch ‘A’ Part-XIII (RAIN WATER HARVESTING WORKS) shall also be applicable. |
| 48 | M&L for soakage well including excavation in ordinary soil, foundation in PCC 1:3:6, well of honeycombed and solid, M-25 concrete, including intercepting chamber, screen chamber, brick in cement mortar, RCC cover slab in M-25/SFRC, interconnecting pipes of RCC/ DWC with fittings, brick bats complete of size (3.60mm dia x 4.50m effective depth) complete all as specified and directed. |
| 49 | M&L for soakage well including excavation in ordinary soil, foundation in PCC 1:3:6, well of honeycombed and solid, M-25 concrete, including intercepting chamber, screen chamber, brick in cement mortar, RCC cover slab in M-25/SFRC, interconnecting pipes of RCC/ DWC with fittings, brick bats complete of size (3.60mm dia x 6.00m effective depth) complete all as specified and directed. |
| 50 | GREEN BUILDING NORMS (GRIHA) (SOLAR PV SYSTEM) WORKS NOTE:- For items of GREEN BUILDING NORMS (GRIHA) (SOLAR PV SYSTEM) WORKS notes given at the beginning of Sch ‘A’ Part-XIV ( GREEN BUILDING NORMS (GRIHA) (SOLAR PV SYSTEM)) WORKS shall also be applicable. |
| 51 | Design,Supply, install, testing and commissioning of ON Grid connected roof top solar generation system of capacity not less than 40 KWp AC capacity all as specified in PS and directed as per PS clause and specification as follows (for (For Single ORs Living)):- |
| 52 | (A) Supply, Installation, testing and commissioning of not less than 40 KWp SPV system comprising of latest specification DCR solar photo voltic modules/array of high efficiency made of mono crystalline silicon solar PV cells with supply and fix of terminal box on the module having provision for opening & replacing the cable etc.as per IEC. The general features of PV modules shall be as given below :-(a) The module shell be made up mono crystalline silicon cells.(b) The interconnected cells shall be laminated in vacuum to withstand adverse environmental conditions. (c) The module frame is made of corrosion resistant materials, preferably having aluminium anodized finish. (d) The minimum clearance between the lower edge of the modules & the developed ground level shall be 300 mm. (e) Surge arresting devices to be provided at junction box and module shall be provided with bypass diode.(f) The SPV module must be IEC 61215, IEC 61730 part I & part II, IEC 61701 certified from any of the accredited certifying agencies. (g) Each solar PV module must be warranted by manufacturer at least 90% rated power at the end of 10 years & 80% at the end of 25 years. Note: Qty of PV module shall be decided as per OEM recommendation, design and layout drawing submitted to department duly approved by GE. |
| 53 | Note:- (i) Makes of panel provided shall be as per MNRE specification/ standard and registered in ALMM. (ii) 5% spare qty of modules shall be provided by the contractor for repair / replacement purpose. (iii) Addln module shall be provided / installed by the contractor to meet specified power output incase if the same not achived during testing and commissioning without any extra cost. (iv) Each PV module used in any solar power project must use a RF identification tag. The following information must be mentioned in the RFID used on each module:-(v) Name of the manufacturer of PV Module(vi) Name of the Manufacturer of Solar cells(vii) Month and year of the manufacture for solar cells and the module(viii) Country of origin (Make in INDIA only) (ix) I-Vcurve for the module(x) Wattage, Im, Vm and FF for the module(xi) Unique Serial No and Model No of the module(xii) Date and year of obtaining IEC PV module qualification certificate(xiii) Name of the test lab issuing EC certificate(xiv) Other relevant information on traceability of solar cells & module. |
| 54 | (B) Module Mounting Structure (MMS) :-Supply & fixing of the anti-corrosive factory made Gl structure on the RCC Roof for fixing of PV modules by fixing of suitable size fastner, spring washer, nuts & bolt. The minimum thickness of galvanization & mounting steel structure shall be as per IS 47592 & IS 2061-1992 respectively withstand the wind load of 180 Km/hr. as per IS 875. The array structure shall be fixed properly using maintenance free earthing kit. Note:- (i)The total load for roof top SPV should be less than 60 Kg/m2. (ii) The design of module mounting structure complying load withstand as per relevant IS alongwith fixing arrangement on roof shall be submitted by the contractor duly vetted from IIT/NIT/Govt Engg college for approval by GE. (iii) The material shall be corrosion resistant and electrolyticaly compatible with material used in module frame. (iv)The fasteners should be of stainless steel and should allow easy replacement of any module. (v) The minimum clearance of the structure from the roof level should be 300 mm. Please Enable Macros to View BoQ information |
| 55 | (B) Module Mounting Structure (MMS) :-Supply & fixing of the anti-corrosive factory made Gl structure on the RCC Roof for fixing of PV modules by fixing of suitable size fastner, spring washer, nuts & bolt. The minimum thickness of galvanization & mounting steel structure shall be as per IS 47592 & IS 2061-1992 respectively withstand the wind load of 180 Km/hr. as per IS 875. The array structure shall be fixed properly using maintenance free earthing kit. Note:- (i)The total load for roof top SPV should be less than 60 Kg/m2. (ii) The design of module mounting structure complying load withstand as per relevant IS alongwith fixing arrangement on roof shall be submitted by the contractor duly vetted from IIT/NIT/Govt Engg college for approval by GE. (iii) The material shall be corrosion resistant and electrolyticaly compatible with material used in module frame. (iv)The fasteners should be of stainless steel and should allow easy replacement of any module. (v) The minimum clearance of the structure from the roof level should be 300 mm. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jun 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysJul 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender