| Sl. No. | Item Description |
| 1 | BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: REPAIR/ MAINT OF 132 MAIN RECEIVING SATATION AND OTHER LOCATIONS UNDER UNDER GE (UTILITIES) UDHAMPUR Contract No: CWE/U(U)-34/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of under ground cable and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed. |
| 4 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 5 | S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS:14930 (Pt-2:200)/IS-16205 Pt-1:2017,IS-16205 Pt-24:2018 for protection of HT cable 120 to 185 sq.mm in under ground complete all as specified & directed by Engineer-in-charge. |
| 6 | Taking proper shut down in writing and Spray painting of transformer at site with one coat of weather proof grey synthetic enamel paint after removing all dust, rust, carbon and oily spots, including well preparation of surfaces and writing /marking SM/MES No as 25mm stencil using white paint complete all as specified including cleaning of temperature gauge and silica gel ,oil temperature level for transformer rating 20 MVA, 132/33 KV complete, all as specified and directed. |
| 7 | All as per Srl item No 5.00 here-in-before but for transformer of rating 250 KVA to 0.415KV voltage level complete, all as specified and directed. |
| 8 | All as per item No. 05.00 but for 145KV potential transformer (132000 V)/ (110V/√3) outdoor type. |
| 9 | All as per item No. 05.00 but for 145KV potential transformer (33 KV)/ (110V/√3) outdoor type. |
| 10 | All as per item No. 05.00 but for 145KV current Transformer 400-200-100 / 1A outdoor type. |
| 11 | All as per item No. 05.00 but for 145KV current Transformer 800-400-200/1A outdoor type |
| 12 | All as per item No. 05.00 but for 33KV current Transformer 400-200-100/1A outdoor type |
| 13 | All as per item No. 05.00 but for 33KV current Transformer 800-400-200/1A outdoor type |
| 14 | All as per item No. 05.00 but for outdoor type Isolater box 145KV/36KV. |
| 15 | Taking down proper shut down from sub station and Scrapping the two pole structure with Emery Paper after that Painting of 33KV HT pole 12m (set of two pole structure including the MS Channel / angle iron) with one coat of Red oxide and after that two coat of Aluminim paint. White washing of foundation and Marking on pole with Glow sign/ Paint sticker showing the Pole no and source of supply complete all as specified and directed. |
| 16 | Repairing / Servicing of potential transformer single phase oil immersed, self cooled, hermetically sealed outdoor type, 145Kv, 50Hz, Ratio (132000 V)/(110/√3) including carrying out following activities complete all as specified and as directed:[a] Checking PT Limb[Ceramic insulator] for any cracks, pitting and burns[b] Cleaning / Decarbonising with CTC[c] Carrying / conducting Ratio Test.[d] Tightening all Primary and Secondary connections.[e] Tightening and fixing basement Nuts & Bolts. |
| 17 | All as per item No. 15.00 but for 36KV potential transformer (33Kv)/ (110V/√3) hermetically sealed. |
| 18 | All as per item No. 15.00 but for 145KV current Transformer 400-200-100 / 1A outdoor type. |
| 19 | All as per item No. 15.00 but for 145KV current Transformer 800-400-200/1A outdoor type |
| 20 | All as per item No. 15.00 but for 33KV current Transformer 400-200-100/1A outdoor type |
| 21 | All as per item No. 15.00 but for 33KV current Transformer 800-400-200/1A outdoor type |
| 22 | Repairing & servicing of 132 KV Isolator & Earth Switch including carrying out following activities complete all as specified and as directed:[a] Cleaning of contact for dust, oxidation & pitting with CTC.[b] Cleaning of all insulators with CTC and observing any cracks and carbon deposits / contents.[c] Repairing, adjusting the rotating arms for perfect operation including lubrication with Petroleum Jelly[d] Repairing / Replacement of Tension Spring in Fixed Contacts.[e] Lubricating of all moving parts for smooth operation.[f] Checking of Auxiliary Contacts and their Calibration[g] Applying Petroleum Jelly to all Electrical Contacts / Moving Contacts.[h] Tightening of all Electrical and Mechanical Connections.Note: The rate quoted is deemed to be inclusive of Consumables like nuts & bolts, washers, petroleum jelly, CTC, T & P etc. complete and necessary safety measures for working in 33 KV Yard. |
| 23 | All as per item No. 21.00 but for 33 KV Isolator & Earth Switch. |
| 24 | Repairs / Servicing of 145KV SF6 circuit breaker out door type with breaking cap 31.5 KA having nominal system voltage 132 KV & rated voltage 145Kv 50Hz, 3 Poles(G.O) out-door interrupting Cap, rated normal current 1250 A, having 2 trip coils auxiliary contacts 12 NO & 12 NC, closing coil 1 No. Arcing time 25 milliseconds, Tripping & closing control circuit voltage 110V DC and spring operated mechanism of ABB make comprising of the following complete all as specified and as directed:[a] Cleaning of Interrupter Limbs for Dust, Oxidising and Decarbonising with CTC.[b] Repair / Servicing of Spring Loaded Operating Mechanism[c] Repair / Servicing of Spring Charging Motor [d] Checking, repairing & servicing of Gearbox, Auxiliary Switches, Spring, Limit Switch etc. complete[e] Checking & Repairing Electrical and Mechanical Operations[f] Checking & Repairing Remote Closing and Tripping of SF6 bracker from Control Panel.[g] Lubrication all Moving Parts with Petroleum Jelly & cleaning all Bushing Insulators with CTC[h] Tightening of all Mechanical Connections of Mechanism[i] Tightening of all HV and LV Connection. Note: Spares required for Servicing / Repairing of SF6 bracker shall be measured and separately under respective items of this BoQ at supply only rates. |
| 25 | Repairs / Servicing of 36KV VCB outdoor type with hallow porcelain insulated porcelain clad VCB having nominal system voltage 33KV highest system voltage 36KV interrupting capacity rated normal current 1250A, frequency 50Hz, short circuit current 25KA, control circuit voltage 110V DC, of ABB make and comprising of the following complete all as specified and as directed:[a] Cleaning of Vacuum Interrupter Limbs for Dust, Oxidising and Decarbonising with CTC.[b] Repair / Servicing of Spring Loaded Operating Mechanism[c] Repair / Servicing of Spring Charging Motor [d] Checking, repairing & servicing of Gearbox, Auxiliary Switches, Spring, Limit Switch etc. complete[e] Checking & Repairing Electrical and Mechanical Operations[f] Checking & Repairing Remote Closing and Tripping of VCB from 33KV Control Panel.[g] Lubrication all Moving Parts with Petroleum Jelly & cleaning all Bushing Insulators with CTC[h] Tightening of all Mechanical Connections of Mechanism[i] Tightening of all HV and LV Connection of VCB. Note: Spares required for Servicing / Repairing of 36 KV Circuit Breaker shall be measured and separately under respective items of this BoQ at supply only rates. |
| 26 | Supply only following spares suitable for 145 KV Outdoor type SF6 Breaker of make:ABB Model No LTB145D1/B complete all as specified & directed:- |
| 27 | Damper suitable for 145 KV Outdoor SF6 Breaker of make ABB cat part No 1HYB300862-A as per existing model complete all as specified & directed. |
| 28 | Tripping latch Assembly for 145 KV Outdoor SF6 Breaker of make ABB cat part No EXIN200410-R1 as per existing model complete all as specified & directed. |
| 29 | Closing latch Assembly for 145 KV Outdoor SF6 Breaker of make ABB cat part No EXIN200416-R1 as per existing model complete all as specified & directed. |
| 30 | Closing coil 110/220V for 145 KV Outdoor SF6 Breaker of make ABB cat part No EXIN400834-R9 as per existing model complete, all as specified and directed. |
| 31 | Triping coil 110/220V for 145 KV Outdoor SF6 Breaker of make ABB cat part No EXIN400833-R9 as per existing model complete all as specified and directed. |
| 32 | Closing Spring Assembly for 145 KV Outdoor SF6 Breaker of make ABB cat part No 1HYB300784-A as per existing model complete all as specified and as directed. |
| 33 | Triping Spring Assembly for 145 KV Outdoor SF6 Breaker of make ABB cat part No 1HYB300785-A as per existing model complete all as specified & directed. |
| 34 | Limit Switch with bracket complete for 145 KV Outdoor SF6 Breaker of make ABB cat part No 1HYBN700023R1 as per existing model complete, all as specified and directed. |
| 35 | Supply only following spares suitable for 36 KV Outdoor Vacuum Circuit Breaker of Make: ABB model No OVB-VBF 36 complete, all as specified and directed by Engr-in-Charge:- |
| 36 | Geared motor for 220-250V DC suitable for 36 KV Outdoor VCBs of ABB cat part No 1VRC007323G0005, as per existing model complete all as specified and directed. |
| 37 | MC open Coil Mo1(220-250V DC/220-250V AC) suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR004289G0007 as per existing model, complete all as specified and directed. |
| 38 | Auxiliary Switch 8NO + 8NC suitable for 36 KV Outdoor VCBs of ABB cat part No 1 VYN301450-041 as per existing model complete, all as specified and directed. |
| 39 | Trip Coil MO2 Assly 48 Vca-Vcc (Addiyional trip) suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR002985G0003 as per existing model complete, all as specified and directed. |
| 40 | Shunt closing release - MC24VDC suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR004291G0001 as per existing model complete, all as specified and directed. |
| 41 | MU Coil Assly (48V AC-DC) Under Voltage suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR004290G0003 as per existing model complete, all as specified and directed by Engr-in-Charge. |
| 42 | MC Closing Coil (220-250VDC/220-250V AC) suitable for 36 KV Outdoor VCBs of ABB cat part No 1VCR004291G0007 as per existing make & Model complete, all as specified and directed. |
| 43 | S & F of Heat shrinkable type end termination joint kit outdoor type suitable for XLPE insulated HT cable 33000 Volts grade of size 400 Sqmm 3 core complete with jointing material and accessories along with testing after jointing including taking out the old unserviceable joint kit complete all as specified and directed. |
| 44 | S & F of HT Cable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor , 33000 volts earthed grade cross sectional area 400 Sqmm 3 core, laid in trenches, through DWC pipe in road crossing, ducts, fixed along poles, complete all as specified and directed. |
| 45 | Taking down HT Cable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor , 33000 volts earthed grade cross sectional area 400 Sqmm 3 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles, complete all as specified and directed. |
| 46 | 1100 Volts PVC insulated FRLS copper conductor control armoured cable shall comply with standards as IS 1554 (part-I and part-II) pvc Insulated heavy duty electric cable, is 5831 PVC insulation and sheath of electric cable, is 8130 conductor for insulated electric cable and cords, is 3961 current rating of cable, IS 502 extended solid dielectric insulated power cable for rated voltage from 1KV to 30KV, IEC 540 and 540A test methods for insulation and sheath of electric cable and cords, IEEE 383 standard for type test for class II electric cable field splices and connections, swedish standard and SS 424 1475 ClassF3 for flammable test, IEC 332-1 test on electric cable under fire condition, IEC 754 -1 test method for acid generation, ASTMD-2863 oxygen index test and temperature index test NEMA WC5 for accelerated water absorption test and dielectric strength retention test construction of cable shall be such that the PVC fillers will be used to provide uniform circular cross section before the inner sheath is applied. All material shall comply the applicable provisions of the test mentions in the specifications mentioned above, current rating and derating factors under normal conditions of installation shall be as per latest amendment IS-3961 (Part-II) the length of the cable shall be supplied in drum length of 500m for all sizes with tolerance of only 5% of ordered quantity of size 2.5 sqmm 7 core armoured complete all as specified and as directed. |
| 47 | Taking down 1100 volts PVC insulated FRLS copper conductor cable of size, 2.5 sqmm 7 core, complete, all as specified and directed. |
| 48 | Supplying and laying synthetic rubber insulating mat conforming to IS: 15652, suitable for working voltage up to 132 kV (Class ‘C’), having anti-skid surface, fire-retardant and moisture-resistant properties, of size 2.0 m × 1.0 m × 3.0 mm thick, including cutting if required and fixing in position by gluing to the surface by means of approved synthetic rubber-based adhesive in front of switchboards, panels, control boards, etc., complete all as specified and as directed by engr- in- charge. |
| 49 | Inspection & visit for checking the fault occured due to rain, heavy wind and any other breakdown related to 132 KV Yard and power house, Rectify the fault at own arrangement and report to JE /Engr in charge after rectifying the fault and proper testing and commissioning of HT line. All minor spare and parts such as nut ,bolts,disc and pin insulator,streching of conductor and all other essential accessories required for fault rectification are included in the quoted rates. Note:- Contrator or his rep shall come to the site of breakdown within one hour of notification of breakdown. In case the rep or contractor shall not come to the site of breakdown and start attending breakdown within 1.00 hour a penalty of Rs 1000 per fault per hour will be imposed over contactor and will be deduct from his dues. |
| 50 | Complete draining out the transformer oil from radiators after closing the inlet valve from main body of 20 MVA power transformer including topping up/filling New transformer oil of good quality having not less than 70 KV dielectric strength, having low viscosity all as specified and directed by Engr-in-Charge. Note: 1)Oil as per IS 335 of 1983 all as specified and testing of Transformer after filling new oil upto 10 Hrs minimum as per entire satisfaciton complete all as specified and directed. 2) dehydration machine and testing kit will be provided by the Dept. but transportation of machine is the responsibility of Contractor without any extra cost to the dept. Sample testing will be carried out in the presence of Engr-in-Charge on site. |
| 51 | Dehydration & filtration of transformer oil in existing transformers installed at site with portable plant to improve the dielectric strength 70 KV at 2.5mm gap using dehydration plant complete, all as specified and directed by Engr-in-Charge.Note:- (a) Qualified technician for Dehydration & filtration of transformer oil shall be deputed. |
| 52 | M&L for rewinding of HT/LT coil conforming to the original winding of the transformer of any make/capacity with super enamelled cooper wire/strip or DPC copper wire of appropriate gauge and turns including allied materials complete, all as specified and directed by Engr-in-Charge. |
| 53 | S & F in replacement silica gel breathers assembly filled with silica gel complete suitable for transformer cap 20 MVA (As per Sample) complete all as specified and directed. |
| 54 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion inclusive of necessary earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover with handle complete as per electrical plate No. 3 of MES SSR Part-I. Note:- All the joints shall be made with welding to get proper conductivity. |
| 55 | 36KV porcelain Post insulator having highest system voltage 36KA. 50Hz short ckt current 25KA, phase to phase distance 1.5M height of insulator 508.00mm used for support ACSR conductor use for interconnection, fixed in repairs, complete all as specified & directed. |
| 56 | 145Kv porcelain Post insulator having highest system voltage 145Kv, 50Hz short circuit current 31.5 KA, phase to phase spacing 3m height of insulator 1460 mm used for support ACSR conductor use for interconnection, fixed in repairs, complete all as specified & directed. |
| 57 | Disc type insulator including its accessories of GI for 33 KV volts grade with three 11 KV insulator in one series. (One unit shall be set of three) fixed in repairs, complete all as specified & directed. |
| 58 | ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps, fixed in repairs, complete all as specified & directed. |
| 59 | Taking out ACB trolley from LT control panel 415 V 3 phase 800 Amp , 50 kA, 4 Pole (Make :- schneider) and cleaning the ACB with CRC removing all dust , carbon etc greasing the mechanical parts gears ,lever charging male female contacts and spring holders and testing and calibration for overload current and fault current complete all as specified and directed. |
| 60 | Material and labour for topping up / filling of SF-6 gas from authorised rep of OEM to achieve required gas pressure & at appropriate level in 145 KV SF6 breaker by opening both cover of breaker and refixing after testing on load, complete all as specified and directed. |
| 61 | Calibration of overcurrent earth fault relay of make Siemens ( model No 7SJ66) as per existing load for earth fault , over current and short circuit ,including setting the relay on required electric load and testing on earth fault and short circuit and over load with the help of relay testing kit for 132KV & 33 KV system complete all as specified and directed. |
| 62 | Filling crushed/broken aggregate of gauge exc 20 mm and not exc 25 mm in layer thickness 150 mm laid in sub station yard, complete all as specified and directed. |
| 63 | Supply and fixing in replecement of 32 Amp,4pole, 110 V DC, 50 Hz Power contactor auxilary contact 2 NO + 2 NC, of coil voltage 110 Volts DC , complete all as specified and directed. |
| 64 | Supply and fixing in replecement of 16 Amp,4pole, 110 V DC, 50 Hz Power contactor auxilary contact 2 NO + 2 NC, of coil voltage 110 Volts DC , complete all as specified and directed. |
| 65 | Supply and fixing in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of Two poles and current carrying capacity upto 5-32 AMP, Complete with connection all as describe by specified & directed. |
| 66 | Supply and fixing in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of four poles and current carrying capacity upto 32 AMP, Complete with connection all as describe by specified & directed. |
| 67 | Supply and fixing in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity upto 5-32 AMP, Complete with connection all as describe by specified & directed. |
| 68 | Supply and fixing in replacement 415V, 10 KA 'C' curve motor protection circuit breaker (MPCB) of Four poles and current carrying capacity upto 200 AMP, Complete with connection all as describe by specified & directed. |
| 69 | Supply and fixing in replacement Push button ( in replacement ) Green colour 'NO', Red colour 'OFF' contact( vasihno make,cat no.2xvaf,flush type) complete all as specified and directed. |
| 70 | Supply & Fix in replacement rechargeable 2 volt 200AH tubular gel VRLA battery cell @C10 at 27º C upto 1.75 E.C.V. complete all as specified & directed by Engr-in-charge Recharging characteristic during operation is as under is as under Recommended parameters for ambienl temperature of 25-30 CCharging Current Maximum - 40AMinimum – 20ABulk Voltage 2.40 ± 0.02 V / cellFloat Voltage 2.28 ± 0.02 V / cellEqualizing Voltage 2.40 ± 0.02 V / cellLoad Reconnect Voltage 2.20 ± 0.02 V / cellLoad Voltage disconnect 1.80 ± 0.02 V / cell |
| 71 | Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 33 KV line, fixed in repairs, complete all as specified & directed. |
| 72 | Material & labour for repair /overhauling/Servicing of OLTC ( On load tap changer ) of 132KV/33 KV Power transformer of capacity 20 MVA at site by carried out following work :-(a) Opening of top plate of OLTC.(b) Draining out of transformers oil from the OLTC. (c) Stoping of leakage of oil from main shaft of OLTC including replacement of oil seal and all gasket of OLTC.(d) Checking /servicing of moving and fixed contact of OLTC and resistence test of contact.(e) Flushing of OLTC assembly with hot new oil and removing of sludge.(f) Filling of new transformer oil in OLTC .(g) Tightening of all tapping leads and connections. (h) Refixing of top plate of OLTC in original position after overhauling.(i) Electrical testing of manual/auto operation of OLTC.Note :- Transformer oil as required shall be measured and paid separately. |
| 73 | Material & labour for repair /servicing of marshalling box panel of 132 KV/33 KV Power transformer of capacity 20 MVA including follwing :-(a) Testing & repair to control wiring.(b) Testing of OTI, WTI , meter matching with OTI, WTI indicator in RTCC panel.(c) Replacement of burned fuse.(d) Repalacement of gaskets & locks including preparation of old painted surfaces of steel by brushing/cleaning stain, greasy spots with thinner etc complete all as specified and directed. |
| 74 | Supply of glyphosate-based herbicide for eradication of grass and unwanted vegetation in electric substation yard, including dilution with water in approved proportion (1:50 to 1:70), application as per manufacturer’s instructions, and complete all as specified and directed by Engineer-in-Charge. |
| 75 | M & L for fixing earth pit chamber identification board made out of 3.15 mm thick mild steel sheet of size 45 cm × 30 cm, fixed on 12 mm dia MS rods (2 Nos.) of 90 cm height, including fixing with nuts & bolts, complete. The board shall be painted with two coats of synthetic enamel black paint over a suitable primer on both sides, including writing of letters (6 cm height) in white paint indicating Earth Pit No., Location, Earthing Test Value and Date, including all materials, labour, tools & plant, transportation and all incidental charges, complete as specified and as directed by Engineer-in-Charge |
| 76 | Repair/maintenance of existing GI plate earthing complete, comprising excavation of earthing pit, taking out and checking of existing GI earth plate, replacement of unserviceable earth plate if required, renewal/replacement of GI Strip, nuts, bolts, washers and clamps, refilling of pit with fresh charcoal/coal and common salt in layers, watering, ramming and backfilling, making good disturbed surface to original condition, cleaning of all contact surfaces and applying anti-corrosive compound, and testing of earth resistance on completion, complete all as specified and as directed.” |
| 77 | Repair to Over Gate Name Board with LED Illuminated Letters, comprising dismantling of damaged/defective portions of existing name board, including replacement/repair of MS frame and MS sheet (minimum 3.15 mm thick), straightening, cutting, welding and grinding; providing and fixing LED based illuminated letters of approved size, font and colour complete with wiring, LED modules, driver, connections and fixing arrangement; renewal of nuts, bolts, washers and welding rods as required; scraping and thorough surface preparation by removing old paint, rust, dirt etc.; applying one coat of red oxide primer and two coats of synthetic enamel paint of approved shade to background surface; including lettering/finishing in contrasting colour, testing of LED system, complete all as specified and as directed by Engineer-in-Charge. |
| 78 | M & L for fixing of VCB panel outgoing feeder name plate (polycarbonate engraved type), comprising supply of approved quality polycarbonate label of suitable size, with feeder name laser engraved in clear bold letters (minimum 10–15 mm height) of approved font and colour; label to be waterproof, heat resistant and non-fading; including cleaning of surface, proper alignment, and fixing with suitable adhesive/fasteners complete all as specified and as directed by Engineer-in-Charge. |
| 79 | M & L for fixing of illuminated Power House building name board in replacement , comprising fabrication of MS frame using suitable angle/box section, cladding with MS sheet (minimum 3.15 mm thick) / ACP sheet as approved, cutting, welding, grinding and making smooth surface; providing and fixing acrylic/ACP letters with LED backlit/front-lit illumination system, including LED modules, driver, internal wiring, connections, and weatherproof housing; carrying out scraping, surface preparation, application of one coat of red oxide primer and two coats of synthetic enamel paint of approved shade to frame/background; fixing in position with suitable supports, nuts, bolts, fasteners and making good all disturbed surfaces; testing and commissioning of complete illumination system, complete all as specified and as directed by Engineer-in-Charge. |
| 80 | S & F of Remote Terminal Unit (RTU) in existing SCADA panel by replacing the unserviceable RTU, complete with all necessary hardware, wiring modifications, configuration, integration with existing SCADA system, communication setup (Modbus/IEC 60870-5-101/104/DNP3), including I/O interfacing (AI, DI, DO), testing of all signals, trial run, and handing over, complete in all respects as specified and as directed by Engineer-in-Charge. |
| 81 | S & F of Power Supply Unit (PSU) in existing SCADA/RTU panel by replacing the unserviceable PSU, suitable for required input and output ratings (e.g., 230V AC to 24V DC), complete with removal of old unit, re-termination of input/output wiring, proper mounting, earthing, and integration with existing system, testing of output voltage and load conditions, trial run and commissioning, complete in all respects as specified and as directed by Engineer-in-Charge. |
| 82 | S & F of terminal blocks in existing SCADA/RTU panel by replacing the damaged/unserviceable terminal blocks, complete with removal of old terminals, re-termination of all field and control wiring, proper ferruling, dressing and identification, ensuring tight connections, checking continuity and insulation, and restoring all circuits to original condition, including testing, trial run and commissioning, complete in all respects as specified and as directed by Engineer-in-Charge. |
| 83 | S & F of Communication Gateway (GTW) in existing SCADA/RTU panel by replacing the unserviceable gateway, suitable for required communication protocols (Modbus RTU/TCP, IEC 60870-5-101/104, DNP3, etc.), complete with removal of old unit, re-termination of communication and power cables, configuration and protocol mapping, integration with existing SCADA system, testing of communication links, data transfer verification, trial run and commissioning, complete in all respects as specified and as directed by Engineer-in-Charge. |
| 84 | Repair of complete Ethernet-based communication network for 132 kV substation, including managed industrial Ethernet switches, routers, optical fiber connectivity (if applicable), and integration with existing SCADA, protection relays, RTU and gateway devices, complete with IP addressing, VLAN configuration, redundancy protocol (RSTP/PRP/HSR), protocol configuration (IEC 61850, IEC 60870-5-104, Modbus TCP), data mapping, network security setup, testing, commissioning and documentation, complete in all respects as specified and as directed by Engineer-in-Charge. |
| 85 | Comprehensive cleaning, inspection, servicing and maintenance of SCADA panel including removal of dust using vacuum/air blower, cleaning of all internal components such as RTU, gateway (GTW), power supply unit (PSU), switches, relays, terminal blocks and wiring, tightening of all electrical connections, checking of earthing, inspection of communication and power cables, verification of indication lamps and alarms, functional checking of all I/O signals, health check of communication network, minor repairs/rectification, and complete testing & restoration of system, including proper reassembly, trial run and handing over, complete in all respects as specified and as directed by Engineer-in-Charge. |
| 86 | Dismantling and taking down the complete high mast tower 30 mtr height by removing bolts and nuts at the bottom with the help of crane and removing the worn out /cut stainless steel GI wire unservicable pulley,shafts checknuts etc including fixing new spares,applying grease, checking and rectifying mechanical and electrical connections and re-erecting the same after making functional of all components complete all as specified and as directed by Engr-in-charge.Note:(i) Necessary Spares shall be measured and paid separately under relevant item/items of the schedule. The rate for minor spares necessary for carryingout the repair work which are all not covered under the schedule shall also deemed to be included the quoted rate.(ii) The rate quoted deemed to be included the rate of all manpower including technicians, crane operator etc. and all tools and plants including crane/motor required to carryout above work.(iii) The light assembly shall also be checked twice in the contract period other than the repairing time by taking down the light assembly from top to bottom and taking up to the original position (i.e. from bottom to top) after completing the repair work if any including checking the serviceability of high mast operating mechanism. |
| 87 | Supply and fix in repair reverse forward switch suitable for existing high mast light tower 30 Mtr height including taking down old and unserviceable R/F switch etc complete all as specified and as directed by Engr-in-charge |
| 88 | Supply and fix galvanised steel wire rope 10 mm dia suitable for existing high mast light tower 30 Mtr height including taking down old rope complete all as specified and as directed by Engr-in-charge. |
| 89 | Supply and fix in repair pulley for geared motor after removing old and unserviceable pulley including applying grease and gear oil for making the high mast functional complete all as specified and as directed by Engr-in-charge |
| 90 | Supply and fix in repairs aviation obstruction light LED comprising aluminium housing with poly carbonate enclosure, 302 members LED are provided complete all as specified and directed by Engr-in-charge. |
| 91 | Supply and fix in repair energy saving rectangular LED flood light fitting 400 Watts, 240 volts AC, cool white colour, CCT 5700°K, CRI>70, THD<10%, system lumens not less than 120 lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection ingress protection, 10 KV external surge protection, efficacy 120 Lm/watt aluminium pressure die cast housing with toughened glass visor, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and directed by Engr-in-charge. |
| 92 | Supply and fix of LED flood light, 150 watt, 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engr-in-Charge.Make-Bajaj Cat Part No. PRAZE F 144L WH NB-A5 TG SD/Philips / Crompton Cat Part No.LLN-150-CDL/60-M or equivalent from the list of make given in particular sepecifivationNote: For item Serial no 75.00 to 76.00 (a) MS clamp,Brackets required for fixing of fitting are inclusive of rate quoted.(b) Necessary grouting/making good on existing surfaces in inclusive of rate quoted.(c) GI pipe of required dimensions if required at site shall be provided by the contractor. |
| 93 | S&F of Steel tubular swaged Ring suitable for 12 m long pole for semi highmast light and for fixing of four nos flood loghts with bolts, nuts and screws, ring made out of ERW MS tubing conforming to IS-2713 including drilling of holes of required size for fixing of brackets , painting the exposed surfaces of ring with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of silver paint on the surface complete all as specified and directed by Engr-in-Charge. |
| 94 | Supply and fixing in replacement of LED light fitting 4 feet 1 x 20 W, 220 V AC Decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed. |
| 95 | Supply and fixing in replacement of LED light fitting mirror type with high output diffuser 2 feet, 1 x 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed. |
| 96 | Supply & Fixing of Building Security LED light with fitting 35 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge. |
| 97 | Supply, fixing, testing and commissioning new display board of size 3 ft × 2 ft made of 3 mm thick ACP sheet with blue background and white coloured letters/text including digital vinyl printing with laminated overlay, complete with all accessories and mounted on two SS pipe poles of 50 mm (2 inch) dia and 8 ft height overall (2 ft embedded in RCC foundation and 6 ft exposed above ground), including PCC foundation, excavation, and ensuring that all text/images are clearly legible and fade-resistant, Letters to be display shall be as specified and directed by Engineer-in-Charge.Notes:Rate of PCC block of mix 1:3:6 type C-2 of size 1 ft × 1 ft × 1.5 ft for grouting of both poles, Excavation, refilling and disposal/removal of surplus earth shall be included in quoated rate. |
| 98 | Supply, fixing, testing and commissioning new display board of size 3 ft × 2 ft made of 3 mm thick Acrylic sheet with LED illumination complete with all accessories and mounted on two SS pipe poles of 50 mm (2 inch) dia and 8 ft height overall (2 ft embedded in RCC foundation and 6 ft exposed above ground), including PCC foundation, excavation, and ensuring that all text/images are clearly legible and fade-resistant, Letters to be display shall be as specified and directed by Engineer-in-Charge.Notes:Rate of PCC block of mix 1:3:6 type C-2 of size 1 ft × 1 ft × 1.5 ft for grouting of both poles, Excavation, refilling and disposal/removal of surplus earth shall be included in quoated rate. |
| 99 | Repairing/servicing of existing 110 Volt DC Float Cum Boost Charger (FCBC) battery charger suitable for control and relay panel installed at 132 kV substation complete, including dismantling, inspection, fault finding, servicing of float/boost charging circuits, rectifier unit, thyristor/SMPS module, control PCB, transformer, voltage/current sensing circuit, indicating lamps, meters, annunciation, relays, contactors, MCCB/MCB, cooling fan, terminal connections and internal wiring, replacement of minor defective components, cleaning, calibration, testing of float and boost operation, output voltage/current setting, charging performance test and commissioning complete all as specified and as directed by Engineer-in-Charge. |
| 100 | Servicing, cleaning, testing and commissioning of existing Remote Tap Changer Control (RTCC) Panel suitable for 20 MVA, 132/33 kV Power Transformer installed at 132 kV Sub Station, comprising checking of AVR relay, tap changer control circuitry, annunciation system, indicating lamps, selector switches, space heater, temperature indicators, mimic indications, wiring terminals, tightening of all electrical connections, cleaning with blower/vacuum, replacement of minor consumables, functional testing in local/remote mode and calibration/checking complete all as specified and as directed by Engineer-in-Charge Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail