| 1 | Taking down/ out carefully copper/aluminium point wiring for light/ fan/ bell/ sockets 5/15 Amps complete without accessories such as switches, Sockets, holders, ceiling roses, light fitting regulators etc. ( to be measured separately) and making good the disturbed surface complete all as specified and directed. |
| 2 | Taking down/ out carefully copper/aluminium sub main wiring for any size and making good the disturbed surface complete all as specified and directed. |
| 3 | M&L for point wiring complete with 1.5 Sqmm (nominal area) FRLS, PVC insulated un-sheathed and stranded copper conductor cable ISI marked drawn through existing concealed conduit including FRLS, PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and provision of modular box covered with modular top cover for mounting switches, sockets or fan regulators etc. for One light point/ fan point/ bell point controlled by one switch complete all as specified and directed. |
| 4 | All as per Srl Item No. 3 here-in-before but One socket outlet 5 Amps controlled by one switch on same board |
| 5 | All as per Srl Item No. 3 here-in-before but One socket outlet 5 amps controlled by one switch on independent board |
| 6 | All as per Srl Item No. 3 here-in-before but one light point controlled by two 2 way switches |
| 7 | All as per Srl Item No. 3 here-in-before but wiring with 2.5sqmm copper wire and 2.5sqmm earth wire for socket out let on independent board. |
| 8 | S&F in repair modular switch flush type, 6 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 9 | S&F in repair modular switch flush type, 6 amps two way, SP, 230 volts AC complete all as specified and directed. |
| 10 | S&F in repair modular switch flush type, 16 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 11 | S&F in repair modular switch bell push flush type, 6 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 12 | S&F in repair modular socket outlet 6 amps 5 pin 2 module complete all as specified and directed. |
| 13 | S&F in repair modular socket outlet 6 & 16 amps 6 pin multipurpose combined 2 module complete all as specified and directed. |
| 14 | S&F in repair modular Step Fan regulator, 120 watts single / double module complete all as specified and directed. |
| 15 | S&F in repair Modular white cover plate with frame 1 module complete all as specified and directed |
| 16 | S&F in repair Modular white cover plate with frame 2 module complete all as specified and directed |
| 17 | S&F in repair Modular white cover plate with frame 3 module complete all as specified and directed |
| 18 | S&F in repair Modular white cover plate with frame 4 module complete all as specified and directed |
| 19 | S&F in repair Modular white cover plate with frame 8 module complete all as specified and directed |
| 20 | S&F in repair Modular Metal Flush Box 1/2 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and directed |
| 21 | S&F in repair Modular Metal Flush Box 3 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and directed |
| 22 | S&F in repair Modular Metal Flush Box 4 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and directed |
| 23 | S&F in repair Modular Metal Flush Box 8 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and directed |
| 24 | S&F in repair switch piano flush type, 6 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 25 | S&F in repair switch piano flush type, 6 amps two way, SP, 230 volts AC complete all as specified and directed. |
| 26 | S&F in repair switch piano flush type, 16 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 27 | S&F in repair switch piano bell push flush type, 6 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 28 | S&F in repair socket outlet 6 amps 5 pin, complete all as specified and directed. |
| 29 | S&F in repair socket outlet 6&16 amps 6 pin complete all as specified and directed. |
| 30 | S&F in repair piano type Step fan regulator, 120 watts single/ double module complete all as specified and directed. |
| 31 | S&F in repair of Ceiling rose, insulated body, 3 terminal, 240 volts complete all as specified and directed, |
| 32 | S&F in repair of electric bell of DINGDONG type, 6 Amps, 240 volts, single pole and making all necessary connections complete all as specified and directed. |
| 33 | S&F in repair of wall light fitting decorative type suitable for LED lamp complete all as specified and directed. |
| 34 | S&F in repair LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 20 Watts, cool/warm white as per site requirement complete all as specified and directed. |
| 35 | S&F in repair of LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 10 Watts, cool/warm white as per site requirement complete all as specified and directed. |
| 36 | S&F in repair of Ventilating fan 200 mm sweep plastic body type including self-closing louver and making all electric connections complete all as specified and directed. |
| 37 | S&F in replacement of energy efficient LED fittings 35W LED suitable for building security light pressure die cast aluminium roadway luminaire with high power LEDs and HF electronic driver complete all as specified and directed. |
| 38 | S&F in replacement of street light fitting bracket, 1.0 mtr long made out of galvanized iron pipe of 25 mm dia size light grade complete with nut, bolts, washer, clamps etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as specified and directed. |
| 39 | S&F of MCB DB confirming to IP 43 - IK 09 with double door, SPN 12 way, double door complete with din rail, Neutral and earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces complete all as specified and directed. |
| 40 | S&F in repair of MCCB incomer Distribution Board ( Vertical Load line DB) double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incomer and MCB as outgoing and making all necessary connections and taking out the old unserviceable DB complete all as specified and directed. Note:- MCCB & MCBs will be measured and paid separately |
| 41 | S&F in repair of TPN DB 04 way double door confirming to IP43 & IK 09 protection complete with din rail, Neutral and earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces complete all as specified and directed. |
| 42 | S&F in repair of MCB B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection complete all as specified and directed. |
| 43 | S&F in repair Isolator SPN 40 A including connections complete all as specified |
| 44 | S&F in repair Isolator SPN 63 A including connections complete all as specified |
| 45 | S&F in repair Isolator TPN 40 A including connections complete all as specified |
| 46 | S&F in repair Isolator TPN 63 A including connections complete all as specified |
| 47 | S&F in repair of MCCB, 415 volts, three pole of cap 100 Amps, 10 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including necessary spreader / thimbles of suitable size and making connections complete all as specified and directed. |
| 48 | M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground not less than 2.25 mtrs below ground level with top edge of plate not less than 1.5 mtr deep below normal ground level connected to galvanised earth wire 4 mm by means of nuts, bolts and check nut to earth plate and to main board or DB including necessary PCC 1:2:4 type B-1 pit, cover frame , GI pipe 15 mm dia light grade for protection and GI pipe 20 mm dia medium grade for watering with funnel, wire mesh, salt and charcoal dust all over the plate complete all as specified and directed. |
| 49 | M&L for wiring for circuit/ submain wiring with 4 single core PVC FRLS insulated copper conductor 6 sqmm and same 6 sqmm for continuous earth wire drawn in to existing conduit complete all as specified and directed. Note: Cost of earth wire including in sub main wiring |
| 50 | M&L for wiring for circuit/ submain wiring with two single core PVC FRLS insulated copper conductor 10 sqmm and same 10 sqmm for continuous earth wire drawn in to existing conduit complete all as specified and directed.Note: Cost of earth wire including in sub main wiring. |
| 51 | M&L for wiring for circuit/ submain wiring with two single core PVC FRLS insulated copper conductor 4 sqmm and same 4 sqmm for continuous earth wire drawn in to existing conduit complete all as specified and directed. Note: Cost of earth wire including in sub main wiring. |
| 52 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20AMP complete all as specified and directed. |
| 53 | Supply and laying rigid non-metallic PVC surface conduit size 25mm all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. with all fitting including making good complete all as specified and directed. |
| 54 | M&L for cutting into brick walls upto reqd depth and height and making good point in CM 1:3 for submain wiring for AC connection and applying 02 coat of existing finishing complete all as specified and directed. |
| 55 | S&F in repair of Bakelite sheet 3mm thick of size 8\\"x5\\" duly wire cut for switches, sockets, regulator etc as per site complete all as specified and directed. |
| 56 | S&F in repair of Bakelite sheet 3mm thick of size 9\\"x11\\"duly wire cut for switches, sockets, regulator etc as per site complete all as specified and directed. |
| 57 | S&F in repair of Bakelite sheet 3mm thick of size 11\\"x13\\" duly wire cut for switches, sockets, regulator etc as per site complete all as specified and directed. |
| 58 | S&F in repair of 'T' cover Bakelite sheet 2 mm thick in round shape complete all as specified and directed. |
| 59 | S&F in repair exhaust fan steel body, AC single Phase 230V, 50 Cycle per second, size 300 mm sweep with blades and frame including self-closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and directed. (Taking down old exhaust fan and deposit it to MES Store Yard). |
| 60 | Re-Fixing only electronic/electric meter single phase complete with accessories any size two core copper flexible wire not less than 0.5 mtr for connecting from incoming to outgoing any size complete all as specified and directed. |
| 61 | S&F ceiling fans BLDC type regulator operated complete with blades, down rods and accessories, 230 V, 1200 mm sweep, five star rated with brushless direct current motor (BLDC) complete all as specified and directed. (Taking down old conventional celling fan & deposit to MES store yard). |
| 62 | Supplying and fixing and commissioning of electric water heater (Geyser) storage type ABS body of capacity 25 litre, BEE approved 5 Star rating, 230 V, single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostat, NRV, connection piece PVC connection for hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable including 15 Amp plug suitable for existing socket and fixing material, Nut bolt grouting in wall for hanging the geyser and making good the disturbed surface complete all as specified and directed. Please Enable Macros to View BoQ information |