| 1 | Supply, Installation, Testing and Commissioning of 13 passenger lift machine room less. The rates include the cost of mirror civil works and steel items required for installation of lift complete in all respect to the entire satisfaction of the Engineer-in-charge. No of Lifts:1 No |
| 2 | Types & Capacity:13 passenger 884 kgs |
| 3 | Speed :1.0 meter per second (minimum) |
| 4 | Type of Drive:A.C.V.3.F - Microprocessor based Selective Collective Simplex Control |
| 5 | Motor/Machine:Electric traction gearless motor to be hoised on guide rails within the elevator hoist way |
| 6 | Travel:12 meters approximate |
| 7 | Serving:4 stops, 4 openings (All on same side) |
| 8 | Hoist way available:1850 MM (W) X2500 MM (D) (Pit size will be checked by the firm at site and will be accounted for accordingly while quoted the rate |
| 9 | Car size :As per I.S: 17900 (Part-I): 2022 i.e. 2.06 sqmtr to 2.20 sqmtr |
| 10 | Car Enclosure:Constructed out of scratch resistant stainless steel Honeycomb finish /Monrock finish/ Hairline finish panels |
| 11 | Car & Hoist way door:Constructed out of scratch resistant stainless steel Honeycomb finish /Monrock finish/ Hairline finish panels |
| 12 | Car entrance & Hoist way entrance:Center opening doors 900mm wide 2000mm high with provision of emergency key opening at all landings. |
| 13 | Door operation :Automatic D.C. Power/ A.C.V.3.F. Door operation with adustable door opening & closing timings |
| 14 | Control:Simplex, full collective control with or without attendants |
| 15 | Operation:A.C. variable voltage variable frequency |
| 16 | Power supply:415 volts +/- 10%, 3 Phase, 50Hz A.C. |
| 17 | Over head available:4500mm |
| 18 | Flooring:Granite 20mm thick |
| 19 | PIT available:1600mm deep |
| 20 | Leveling Accuracy:(+/-) 5mm Independent of load in the car |
| 21 | Indicator:Digital direction and position indicators in both car and at all landings |
| 22 | Guide Rails:Tongue & Groove Guide Rails |
| 23 | Maintenance:Free Maintenance/ Fortnightly service for one year |
| 24 | Safety & Buffers:As per I.S.I Provisions |
| 25 | Fire Safety:As per I.S: 17900 (Part-I): 2022, One hour for landing door |
| 26 | Ceiling & Lighting:As per I.S: 17900 (Part-I): 2022 |
| 27 | Car door lock:As per I.S: 17900 (Part-I): 2022 I.e. locking & emergency unlocking of landing & cardoor |
| 28 | Signal/ Accessories:(5 way) Press & Speak intercom system among cars & reception. Luminous hall Braille buttons at all landing and inside the car |
| 29 | Steel items |
| 30 | Automatic Rescue Device (As per I.S: 17900 (Part-I): 2022) to automatically bring the elevator to a landing in case of power or controller failure provided with sealed maintenance free batteries of suitable rating for 7 operations of A.R.D in a day with duration of 30 min. The batteries shall be of reputed make (Exide/Amaron) |
| 31 | Load weighing device with over load by pass feature |
| 32 | Voice announcement system with music in the car to announce the position of the elevator as the car stops at a floor served by the elevator |
| 33 | Full height infra red safety curtain |
| 34 | Fireman Drive |
| 35 | Stainles steel panels in false ceiling |
| 36 | LCD/LED/Digital display in car/ Braille button/PWD Friendly |
| 37 | Car operating panel with door open/close button |
| 38 | LED Lighting (As per I.S: 17900 (Part-I): 2022) |
| 39 | Alarm & Emergency light (Concealed) with re-chargeable battery) |
| 40 | Over load drive |
| 41 | Fireman Switch |
| 42 | Air fan at ceiling for air ventilation (As per OEM) |
| 43 | Audio signal in case of emergency stop/any interruption should be provided in the lift car |
| 44 | Correction Drive |
| 45 | Hall lantern and gong at all landings |
| 46 | Phase failure detection |
| 47 | Voltage stabilizer for control system |
| 48 | Additional car gate lock to prevent the car door to be opened hand rail on three side of car from inside the car in case the car is not at floor level |
| 49 | Lift should be provided with safety for uncontrolled upward movement, free fall, excessive speed, unattended car movement & creeping of the car as per As per I.S: 17900 (Part-I): 2022 |
| 50 | Refuge spaces, pit & overhead clearances |
| 51 | Provision for emergency exit in the ceiling of the car |
| 52 | Installation & Commissioning: The job includes installation, testing, commissioning as required to complete the work in all respect including cost of all material, T & P, Carriage & Labour etc |
| 53 | Civil Work: The firm shall provide scaffoling, M.S joint/Channels, Pit ladders and minor civil works etc. as required at no extra payment. The complete lift including testing, commissioning and safety provisions shall conform to various Indian standard and rules with up to date ammendments as mentioned below: |
| 54 | Standard & Rules:As per I.S: 17900 (Part-I): 2022 (latest) |
| 55 | General Technical Specifications:As per CPWD specifications and relevant I.S code |
| 56 | Make:Otis/Kone/Johnson/Schindler/Thyssenkrupp Please Enable Macros to View BoQ information |
| 57 | PART-B |
| 58 | The firm should quote the AMC Cost for Five years after one year warranty period :- |
| 59 | A.M.C For 1st year from the date of handing over of lift - Free AMC |
| 60 | A.M.C for 2nd year |
| 61 | A.M.C for 3rd year |
| 62 | A.M.C for 4th year |
| 63 | A.M.C for 5th year |
| 64 | A.M.C for 6th year |