| 1 | Taking down/ out carefully copper/aluminium point wiring for light/ fan/ bell/ sockets 5/15 Amps complete without accessories such as switches, Sockets, holders, ceiling roses, light fitting regulators etc. (to be measured separately) and making good the disturbed surface complete all as specified and directed |
| 2 | Taking down/ out carefully copper/aluminium sub main wiring for any size and making good the disturbed surface complete all as specified and directed. |
| 3 | M&L for point wiring complete with 1.5 Sqmm (nominal area) FRLS, PVC insulated un-sheathed and stranded copper conductor cable ISI marked drawn through existing concealed conduit including FRLS, PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and provision of modular box covered with modular top cover for mounting switches, sockets or fan regulators etc. for One light point/ fan point/ bell point controlled by one switch complete all as specified and directed |
| 4 | All as per Srl Item No. 3 here-in-before but One socket outlet 5 Amps controlled by one switch on same board |
| 5 | All as per Srl Item No. 3 here-in-before but One socket outlet 5 amps controlled by one switch on independent board |
| 6 | All as per Srl Item No. 3 here-in-before but one light point controlled by two 2 way switches |
| 7 | All as per Srl Item No. 3 here-in-before but wiring with 2.5 sqmm copper wire and 2.5 sqmm earth wire for socket out let on independent board. |
| 8 | S&F in repair modular switch flush type, 6 amps one way, SP, 230 volts AC complete all as specified and directed |
| 9 | S&F in repair modular switch flush type, 6 amps two way, SP, 230 volts AC complete all as specified and directed. |
| 10 | S&F in repair modular switch flush type, 16 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 11 | S&F in repair modular switch bell push flush type, 6 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 12 | S&F in repair modular socket outlet 6 amps 5 pin 2 module complete all as specified and directed. |
| 13 | S&F in repair modular socket outlet 6 & 16 amps 6 pin multipurpose combined 2 module complete all as specified and directed. |
| 14 | S&F in repair modular Step Fan regulator, 120 watts single / double module complete all as specified and directed. |
| 15 | S&F in repair Modular white cover plate with frame 1 module complete all as specified and directed |
| 16 | S&F in repair Modular white cover plate with frame 2 module complete all as specified and directed |
| 17 | S&F in repair Modular white cover plate with frame 3 module complete all as specified and directed |
| 18 | S&F in repair Modular white cover plate with frame 4 module complete all as specified and directed |
| 19 | S&F in repair Modular white cover plate with frame 8 module complete all as specified and directed |
| 20 | S&F in repair Modular Metal Flush Box 1/2 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and directed |
| 21 | S&F in repair Modular Metal Flush Box 3 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and directed |
| 22 | S&F in repair Modular Metal Flush Box 4 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and directed |
| 23 | S&F in repair Modular Metal Flush Box 8 module duly embedded in wall in cement mortar 1:4 after chase cutting/cutting of wall tile or marble with cutter and matching/making good the existing surface complete all as specified and directed |
| 24 | S&F in repair switch piano flush type, 6 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 25 | S&F in repair switch piano flush type, 6 amps two way, SP, 230 volts AC complete all as specified and directed. |
| 26 | S&F in repair switch piano flush type, 16 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 27 | S&F in repair switch piano bell push flush type, 6 amps one way, SP, 230 volts AC complete all as specified and directed. |
| 28 | S&F in repair socket outlet 6 amps 5 pin, complete all as specified and directed. |
| 29 | S&F in repair socket outlet 6&16 amps 6 pin complete all as specified and directed. |
| 30 | S&F in repair piano type Step fan regulator, 120 watts single/ double module complete all as specified and directed. |
| 31 | S&F in repair of lamp holder PVC/ Polycarbonate type insulated body with back plate suitable for batten fittings complete all as specified and directed. |
| 32 | S&F in repair of Ceiling rose, insulated body, 3 terminal, 240 volts complete all as specified and directed |
| 33 | S&F in repair of electric bell of DING DONG type, 6 Amps, 240 volts, single pole and making all necessary connections complete all as specified and directed. |
| 34 | S&F in repair LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 20 Watts, cool/warm white as per site requirement complete all as specified and directed. |
| 35 | S&F in repair of LED energy efficient integrated battens fittings, PVC extruded heat sink with shatter proof opal shell of polycarbonate compound, 10 Watts, cool/warm white as per site requirement complete all as specified and directed |
| 36 | S&F in repair of Ventilating fan 200 mm sweep plastic body type including self-closing louver and making all electric connections complete all as specified and directed. |
| 37 | S&F in replacement of energy efficient LED fittings 35W LED suitable for building security light pressure die cast aluminium roadway luminaire with high power LEDs and HF electronic driver complete all as specified and directed. |
| 38 | S&F in repair of street light fitting bracket, 1.0 mtr long made out of galvanized iron pipe of 25 mm dia size light grade complete with nut, bolts, washer, clamps etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as specified and directed. |
| 39 | M&L of submain wiring complete with 2 x 4.0 sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 4 sqmm (same specification) as earth wire in existing PVC conduit complete all as specified and directed |
| 40 | M&L of submain wiring complete with 2 x 6.0 sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistranded copper conductor cable ISI marked, and 1 x 6 sqmm (same specification) as earth wire in existing PVC conduit complete all as specified and directed |
| 41 | S&F in repair MCB DB confirming to IP 43 - IK 09 with double door, SPN 12 way, double door complete with din rail, Neutral and earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces complete all as specified and directed. |
| 42 | S&F in repair MCB DB confirming to IP 43 - IK 09 with double door, SPN 08 way, double door complete with din rail, Neutral and earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces complete all as specified and directed. |
| 43 | S&F in repair MCB DB confirming to IP 43 - IK 09 with single door, SPN 04 way, double door complete with din rail, Neutral and earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces complete all as specified and directed. |
| 44 | S&F in repair of MCCB incomer Distribution Board ( Vertical Load line DB) double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incomer and MCB as outgoing and making all necessary connections and taking out the old unserviceable DB complete all as specified and directed.Note:- MCCB & MCBs will be measured and paid separately |
| 45 | S&F in repair of MCCB, 415 volts, three pole of cap 100 Amps, 10 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including necessary spreader / thimbles of suitable size and making connections complete all as specified and directed. Note: Item should be compatible with item No.44 above. |
| 46 | S&F in repair of MCB B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection complete all as specified and directed. |
| 47 | S&F in repair Isolator SPN 40 A including connections complete all as specified and directed |
| 48 | S&F in repair Isolator SPN 63 A including connections complete all as specified and directed |
| 49 | S&F in repair of Modular AC plug & Socket enclosure with 25 Amps SP mini MCB, 230 Volts, 50Hz. In 4 module sheet metal enclosure complete all as specified and directed. |
| 50 | S&F PVC casing & caping ( ISI marked) 20 mm width double lock type inclusive of all fittings such as tees, bends, elbow, etc and all fixing accessories such as couples, PVC rawal Plugs, saddles, etc complete all as specified and directed. |
| 51 | S&F of PVC casing & caping ( ISI marked) 25 mm width double lock type inclusive of all fittings such as tees, bends, elbow, etc and all fixing accessories such as couples, PVC rawal Plugs, saddles, etc complete all as specified and directed. |
| 52 | S&F rigid non metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete all as specified and directed. |
| 53 | S&F rigid non metallic PVC conduit 25 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc complete all as specified and directed. |
| 54 | M&L for cutting chases in brick walls/ PCC for inserting PVC conduit any size and making good with CM 1:3 to finish the surface complete all as specified and directed |
| 55 | S & F in repair plastic body capacitor of capacity 2.5 mfd with wire suitable for single phase motor and making connection complete all as specified and directed |
| 56 | S&F PVC Gang Box suitable for one No 5 Amps Switch and one No 5 Amps Socket complete all as specified and directed. |
| 57 | S&F PVC Gang Box suitable for two No 5 Amps Switch and two No 5 Amps Socket complete all as specified and directed. |
| 58 | S&F PVC Gang Box suitable for one No 15 Amps Switch and one No 15 Amps Socket complete all as specified and directed. Make : Presto plast/Pressfit/Polyplast. |
| 59 | S&F in repair of aluminium cable 1100 Volt grade, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable circular of size 4 Sqmm ISI marked in service connections, including taking down old unserviceable cable complete all as specified and directed. |
| 60 | S&F in repair of aluminium cable 1100 Volt grade, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable circular of size 6 Sqmm ISI marked in service connections, including taking down old unserviceable cable complete all as specified and directed. |
| 61 | S&F in repair of plug and socket 3 pin 10/20 amp earth metal clad suitable for industrial type DB complete all as specified and directed. |
| 62 | S&F in repair of 'T' cover Bakelite sheet 2 mm thick in round shape complete all as specified and directed. |
| 63 | S&F in repair of Bakelite sheet 3mm thick of size 5\\"x5\\" duly wire cut for switches, sockets, regulator etc as per site requirement complete all as specified and directed. |
| 64 | S&F in repair of Bakelite sheet 3mm thick of size 8\\"x5\\" duly wire cut for switches, sockets, regulator etc as per site requirement complete all as specified and directed. |
| 65 | S&F in repair of Bakelite sheet 3mm thick of size 9\\"x11\\"duly wire cut for switches, sockets, regulator etc as per site requirement complete all as specified and directed. |
| 66 | S&F in repair of Bakelite sheet 3mm thick of size 11\\"x13\\" duly wire cut for switches, sockets, regulator etc as per site requirement complete all as specified and directed. |
| 67 | M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground not less than 2.25 mtrs below ground level with top edge of plate not less than 1.5 mtr deep below normal ground level connected to galvanised earth wire 4 mm by means of nuts, bolts and check nut to earth plate and to main board or DB including necessary PCC 1:2:4 type B-1 pit, cover frame , GI pipe 15 mm dia light grade for protection and GI pipe 20 mm dia medium grade for watering with funnel, wire mesh, salt and charcoal dust all over the plate complete all as specified and directed. Please Enable Macros to View BoQ information |